Thermal Analysis Instruments
Filter
Showing 631–660 of 922 results
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | TAURUS GHP 900 |
| Measurement Principle | Guarded Hot Plate (GHP) |
| Standard Compliance | ISO 8302, ASTM C177, EN 12664, EN 12667, EN 12939, EN 1946-2 |
| Thermal Conductivity Range | 0.005 – 2.0 W/(m·K) |
| Accuracy | ±1.0% |
| Repeatability | ±0.5% |
| Sample Thickness (Single-Sided) | 15 – 280 mm |
| Sample Thickness (Double-Sided) | 2 × 15 – 140 mm |
| Sample Area | 200 × 200 mm to 500 × 500 mm (optional up to 900 × 900 mm) |
| Cold Plate Temperature Range | −10 to +60 °C |
| Hot Plate Temperature Range | 0 to +70 °C |
| Chamber Dimensions (H × W × D) | 233 × 146 × 126 cm |
| Guarded Enclosure | Full adiabatic shielding with active temperature control |
| Automation | Motorized upper plate lift, adjustable heating area, multi-directional sample access |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | TAURUS GHP 900 S |
| Measurement Principle | Guarded Hot Plate Method |
| Test Range | 0.005–2.0 W/(m·K) |
| Accuracy | ±1.0% |
| Repeatability | ±0.5% |
| Sample Thickness (Single-Sided) | 15–380 mm |
| Sample Thickness (Double-Sided) | 2×15–180 mm |
| Sample Area | 200×200–500×500 mm (optional: 900×900 mm or 800×800 mm for insulating glass) |
| Cold Plate Temp Range | −10 to 60 °C |
| Hot Plate Temp Range | 0 to 70 °C |
| Dimensions (H×W×D) | 235×130×120 cm |
| Standards Compliance | ISO 8302, ASTM C177, EN 1946-2, EN 12664, EN 12667, EN 12939, EN 674 |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | TCA 300 |
| Measurement Principle | Heat Flow Meter (HFM) Method |
| Dimensions (L×W×H) | 44 × 40 × 62 cm |
| Accuracy | ±1.0% |
| Thermal Conductivity Range | 0.002 – 1.0 W/(m·K) |
| Repeatability | ±0.5% |
| Sample Size (L×W) | 100 × 100 mm to 300 × 300 mm |
| Sample Thickness (H) | 5 – 100 mm |
| Cold Plate Temperature Range | −20 °C to +60 °C |
| Hot Plate Temperature Range | −10 °C to +70 °C |
| Compliance | ISO 8301, ASTM C518, DIN EN 1946-3, EN 12664, EN 12667, EN 12939 |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | TCA 500 |
| Measurement Principle | Heat Flow Meter Method (HFM) |
| Dimensions (H×W×D) | 179 × 80 × 90 cm |
| Thermal Conductivity Range | 0.005 – 1.0 W/(m·K) |
| Accuracy | ±1.0% |
| Repeatability | ±0.5% |
| Sample Size (L×W) | 250 × 250 mm to 500 × 500 mm |
| Sample Thickness (H) | 10 – 120 mm |
| Cold Plate Temperature Range | −20 °C to +60 °C |
| Hot Plate Temperature Range | −10 °C to +70 °C |
| Standards Compliance | ISO 8301, ASTM C518, DIN EN 1946-3, EN 12664, EN 12667, EN 12939 |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | TDW 4040 |
| Measurement Principle | Guarded Hot Box (Steady-State Heat Flow Method) |
| Instrument Type | Thermal Transmittance (U-value) and Thermal Resistance (R-value) Analyzer |
| External Dimensions (H×W×D) | 300 × 500 × 360 cm |
| Weight | 3890 kg |
| Temperature Range (Hot Side) | 10–40 °C |
| Temperature Range (Cold Side) | −10–40 °C |
| Sample Area Options | 1500 × 1500 mm or 2000 × 2000 mm |
| Maximum Sample Thickness | 360 mm (Standard), 560 mm (Extended) |
| Thermal Resistance Range (R) | 0.10–8.00 m²·K/W |
| Accuracy | ±3.0% (per DIN EN 12937 & ISO 8990) |
| Repeatability | ±1.0% |
| Cooling System | Water-Cooled Circulating Chiller |
| Compliance | DIN EN 12937, DIN EN 1934, ISO 8990, ASTM C1363, EN ISO 10211 |
| Software | HotBox v5.x (Single-User License) |
| Test Frame | Insulated, Forklift-Compatible Roller Base with Adjustable Aperture |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | TDW 4140 |
| Measurement Principle | Guarded Hot Box (Steady-State Heat Flow Method) |
| Compliance Standards | DIN EN ISO 8990, DIN EN 1946-4, DIN EN ISO 12567, DIN EN 12412-2, ASTM C1363 |
| Test Chamber Dimensions (Closed) | 400 × 400 × 405 cm (H×W×D) |
| Test Chamber Dimensions (Open) | 400 × 610 × 405 cm (H×W×D) |
| Sample Capacity (Windows) | up to 2180 × 1480 mm (H×W) |
| Sample Capacity (Doors) | up to 2180 × 2000 mm (H×W) |
| Maximum Sample Thickness | 340 mm |
| Thermal Resistance Range (R-value) | 0.10 – 8.00 m²·K/W |
| Thermal Transmittance Range (U-value) | 0.12 – 3.70 W/m²·K |
| Temperature Control Range (Hot Side) | 10 – 40 °C |
| Temperature Control Range (Cold Side) | −10 – 40 °C |
| Accuracy | ±3.0% |
| Repeatability | ±1.0% |
| Cooling System | Water-cooled recirculating chiller |
| Software | HotBox v5.x (Single License) |
| Weight | 4260 kg |
| Sample Handling | Motorized roller base with fork-lift access ports |
| Insulation Configuration | Fully guarded hot box with calibrated heat flux sensors and precision temperature mapping |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | TDW 4240 |
| Measurement Principle | Guarded Hot Box (Steady-State Heat Flow Method) |
| Compliance Standards | DIN EN ISO 8990, DIN EN 1946-4, DIN EN ISO 12567, DIN EN 12412-2, ASTM C1363 |
| Thermal Resistance Range (R-value) | 0.10 – 8.00 m²·K/W |
| Thermal Transmittance Range (U-value) | 0.12 – 3.70 W/m²·K |
| Sample Height (Windows) | up to 2180 mm |
| Sample Width (Windows) | up to 1480 mm |
| Sample Height (Doors) | up to 2180 mm |
| Sample Width (Doors) | up to 2000 mm |
| Maximum Sample Thickness | 560 mm |
| Cold Chamber Temperature Range | −15 °C to +40 °C |
| Hot Chamber Temperature Range | +10 °C to +60 °C |
| Enclosure Dimensions (Closed) | 400 × 400 × 405 cm (H × W × D) |
| Enclosure Dimensions (Open) | 400 × 610 × 405 cm (H × W × D) |
| System Weight | 4680 kg |
| Accuracy | ±3.0% |
| Repeatability | ±1.0% |
| Cooling System | Water-cooled recirculating chiller |
| Sensor Configuration | Two guarded heat flux meters with protective plates |
| Test Frame | Insulated test frame with roller base and opening for forklift-assisted sample loading |
| Software | HotBox™ v5.x (single-user license) |
| Power Supply | 400 V, 3-phase, 50/60 Hz |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | TG 309 Libra Classic |
| Temperature Range | 10 °C to 1025 °C |
| Temperature Accuracy | ±0.15 K |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | TG 309 Libra Select |
| Temperature Range | 10 °C to 1025/1100 °C |
| Temperature Accuracy | ±0.15 K |
| Heating/Cooling Rate | 0–200 K/min |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | TG 309 Libra Supreme |
| Temperature Range | 10 °C to 1100 °C |
| Temperature Accuracy | ±0.15 K |
| Heating/Cooling Rate | 0–200 K/min |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | TG209F1 Libra |
| Temperature Range | 10 °C to 1100 °C |
| Temperature Accuracy | ±0.2 K |
| Balance Sensitivity | 0.1 µg |
| Heating/Cooling Rate | 0–200 K/min |
| Cooling Time | <15 min (1100 °C → RT) |
| Vacuum Level | 10⁻² mbar |
| Maximum Sample Mass | 2 g |
| Furnace Material | Corrosion-Resistant Ceramic |
| Baseline Correction | BeFlat® Intelligent Baseline Compensation |
| Differential Thermal Signal | c-DTA® Function |
| Optional Automation | ASC Auto-Sampler (192 positions) |
| Optional Module | Temperature-Modulated TGA (TM-TG) |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | TLR 1000 |
| Measurement Principle | Guarded Hot Pipe Method |
| Standards Compliance | DIN EN ISO 8497, DIN EN 1946-5, DIN 52613, ASTM C 534, ASTM C 335 |
| Thermal Conductivity Range | 0.001–0.25 W/(m·K) |
| Accuracy | ±1.0% |
| Repeatability | ±0.5% |
| Sample ID | 18–89 mm |
| Sample OD | 30–220 mm |
| Test Chamber Temperature Range | −15 to +140 °C |
| Heating Pipe Temperature Range | 20 to +200 °C |
| Dimensions (H×W×D) | 45×185×50 cm |
| Sample Throughput | Multi-sample sequential operation |
| Operating Environment | Ambient laboratory conditions |
| Brand | NETZSCH |
|---|---|
| Origin | Germany |
| Model | TMA 4000 SE |
| Temperature Range | –150 to 1700 °C |
| Temperature Accuracy | ±0.1 °C |
| Force Range | 0–4.9 N |
| Displacement Range | ±2.5 mm |
| Dynamic Frequency Range | 0.01–0.5 Hz |
| Measurement Modes | Expansion, Compression, Tension, Penetration, Bending, Dynamic Oscillation, Curing |
| Load Profiles | Constant Force, Sinusoidal (0.01–0.5 Hz), Triangular (0.01–0.2 Hz), Rectangular (0.01–0.1 Hz), Ramp Force (0–0.49 N/min) |
| Deformation Modes | Constant Strain, Strain Ramp (0–50 mm/min), Combined Modes |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | TMA 402 F1 Hyperion |
| Temperature Range | −150 °C to 1550 °C (with interchangeable furnaces) |
| Temperature Accuracy | ±0.1 °C |
| Force Range | ±3 N |
| Displacement Range | ±2.5 mm |
| Displacement Resolution | 1.25 nm |
| Force Resolution | 0.01 mN |
| Heating Rate | 0–50 °C/min |
| Vacuum Level | 10⁻⁴ mbar |
| Measurement Atmospheres | Oxidizing, Reducing, Inert, Vacuum |
| Dual-Furnace Capability | Yes |
| Compatible with DSC/STA Furnaces | Yes |
| Dynamic Force Mode | Optional |
| Rate-Controlled Sintering (RCS) | Optional |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | TMA 402 F3 Hyperion |
| Temperature Range | -150°C to 1550°C |
| Temperature Accuracy | ±0.1°C |
| Force Range | ±3 N |
| Displacement Range | ±2.5 mm |
| Displacement Resolution | 0.125 nm |
| Force Resolution | 0.01 mN |
| Heating Rate | 0–50°C/min |
| Measurement Atmosphere | Oxidizing, Reducing, Inert, Vacuum (down to 10⁻⁴ mbar) |
| Dual-Furnace Capability | Yes |
| Compatible Furnaces | Interchangeable with DSC and STA systems |
| Optional Modes | Dynamic Force, Rate-Controlled Sintering (RCS), Compression/Indentation/Bending/Tension |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | VTMR-niumag |
| Pricing | Available Upon Request |
| Magnet Type | Permanent Magnet |
| Magnetic Field Strength | 0.5 ± 0.05 T |
| Standard Temperature Range | Room Temperature to 130 °C |
| Optional Cryo/High-Temp Module | −100 °C to 200 °C |
| Imaging Capability | Optional |
| Measurement Modes | T₁ & T₂ Relaxometry, NMR Imaging (MRI), Quantitative Analysis |
| Typical Acquisition Time | ≤2 min per sample |
| Sample Forms | Solutions, Gels, Solids, Powders, Particulates |
| Core Technology | FLAT (Fast Low-Amplitude Transient) Pulse Sequence for Short-T₂/Weak-Signal Detection |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Magnet Type | Permanent Magnet |
| Magnetic Field Strength | 0.5 ± 0.05 T |
| Standard Temperature Range | Room Temperature to 130 °C |
| Optional Cryo/High-Temp Module | –100 °C to 200 °C |
| Relaxometry Capabilities | T₁ & T₂ Measurement |
| Advanced Acquisition Technology | FLAT (Fast Low-Amplitude Transient) for Short-T₁/Weak-Signal Samples |
| Sample States Supported | Solutions, Gels, Solids, Powders, Particulates |
| Compliance Framework | Designed for GLP/GMP-aligned workflows |
| Brand | Stanford |
|---|---|
| Origin | USA |
| Model | MPA100 |
| Temperature Range | +10 °C to 400 °C |
| Heating Rate | 0.1–20 °C/min |
| Temperature Repeatability | ±0.1 °C |
| Temperature Accuracy | ±0.3 °C (@ ~100 °C), ±0.5 °C (@ ~250 °C), ±0.8 °C (@ ~400 °C) |
| Capillary Outer Diameter | 1.4–2.0 mm |
| Temperature Resolution | 0.1 °C |
| Power Supply | AC 90–264 V |
| Weight | 4.1 kg |
| Operating Ambient | 0–40 °C |
| Interface | USB, RS-232 |
| Software | MeltView (Windows-compatible) |
| Brand | Orton |
|---|---|
| Origin | USA |
| Model | DIL 2000 Series |
| Max Operating Temperature | 1000 °C (DIL 2010), 1200 °C (DIL 2020), 1600 °C (DIL 2030) |
| Low-Temp Capability | Down to –196 °C (with LN₂ cooling option, DIL 2010C) |
| Sample Dimensions | Up to 50 mm length × 20 mm diameter |
| Repeatability | ±0.004 PLC |
| Heating Rate | 1–30 °C/min |
| Temperature Resolution | 0.1 °C |
| Atmosphere Control | Optional inert/vacuum/oxidizing gas environments |
| Calibration Standards | Included (fused quartz, α-alumina, NIST-traceable reference materials) |
| Brand | Orton |
|---|---|
| Origin | USA |
| Model | DIL2010C |
| Temperature Range | –170 °C to 500 °C (or RT to 1000 °C with standard configuration) |
| Max Sample Size | 50 mm length × 10 mm diameter |
| Furnace Type | Split-tube (clamshell) quartz tube furnace |
| Sample Holder & Pushrod | Fused silica |
| Thermocouple | Type N (sample & control) |
| Heating Rate | 1–30 °C/min |
| LVDT Linear Range | ±2.54 mm |
| LVDT Resolution | 0.02 µm |
| Contact Force | Adjustable |
| Cryogenic Assembly | Stainless-steel cold stage with vertical transfer tube, Dewar reservoir mounted above furnace |
| Ambient Protection | Acrylic enclosure with dry inert gas purge |
| Compliance | ASTM E228, ISO 11359-1/-2, USP <631>, GLP-ready data logging |
| Brand | Orton |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SP-3A |
| Pricing | Upon Request |
| Max Temperature | 1000 °C |
| Temperature Accuracy | ±1 °C |
| Heating Rate | 25 °C/min |
| Probe Travel Range | 0–3 mm |
| Probe Resolution | 0.0025 mm |
| Brand | Orton |
|---|---|
| Origin | USA |
| Model | SP900D / SP1000D |
| Temperature Range | Up to 900°C or 1000°C |
| Heating Rate Control | Programmable PID, 5°C/min standard per ASTM C338 |
| Sample Geometry | Glass fiber, Ø0.65 mm × 235 mm |
| Softening Detection Method | Laser-based axial elongation tracking at 1 mm/min under self-weight |
| Compliance | ASTM C338 (Littleton softening point) |
| Data Acquisition | Real-time PC software with automated calculation, statistical reporting, and audit-ready output |
| Accuracy | ±1°C (repeatability on identical fibers) |
| Software Features | Mode selection, heating profile customization, GLP-compliant data logging, export to CSV/PDF |
| Brand | NANJING DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Model | DSC 100A |
| Sample Capacity | Single-sample |
| Temperature Range | Ambient to 600 °C |
| Heating/Cooling Rate | 0.1–100 K/min |
| Temperature Accuracy | ±0.01 °C |
| DSC Signal Range | 0–±600 mW |
| Temperature Stability | ±0.01 °C |
| Temperature Resolution | 0.01 °C |
| DSC Noise Level | 0.01 μW |
| DSC Sensitivity | 0.001 mW |
| DSC Resolution | 0.01 μW |
| Temperature Repeatability | ±0.1 °C |
| Gas Flow Control | Digital Mass Flow Controller |
| Interface | USB 2.0 Bidirectional Communication |
| Display | 7-inch 24-bit Color TFT Touchscreen |
| Sensor Material | Corrosion-Resistant Alloy |
| Calibration | Onboard Standard Reference Materials with One-Touch Thermal & Enthalpy Calibration |
| Brand | Panco |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | TEGeta |
| Measurement Principle | Steady-State Heat Flow Method (Thermal Gradient + Simultaneous Electrical & Thermal Response) |
| Typical Sample Area | 50 mm × 50 mm |
| Customizable Sample Area | up to 80 mm × 80 mm |
| Temperature Range | Up to 900 °C |
| Voltage Range | 0–60 V (±1% accuracy) |
| Current Range | 0–30 A (±2% accuracy) |
| Heating Power | Up to 800 W (±10% tolerance) |
| Measured Parameters | Thermal Flux, Average Seebeck Coefficient (µV/K), Average Thermal Conductivity (W/m·K), Average Electrical Resistivity (µΩ·m), Maximum Output Power (mW/cm²), Conversion Efficiency (%) |
| Repeatability | High |
| Accuracy Class | High-Precision Laboratory Grade |
| Compliance Context | Designed for ASTM E1530, ISO 22007-2, and GB/T 33792–2017 compliant workflows |
| Brand | Parr |
|---|---|
| Origin | USA |
| Model | 6200 |
| Measurement Mode | Isoperibol |
| Temperature Range | 0–40 °C |
| Temperature Resolution | 0.0001 °C |
| Precision | ±0.1% RSD |
| Single-Sample Test Time | 6–7 min |
| Heat Capacity | 33,000 J |
| Outer Water Jacket Volume | 2 L |
| Inner Water Bucket Volume | 342 mL |
| Oxygen Bomb Pressure Rating | 200 atm |
| Bomb Volume | 342 mL |
| Data Storage Capacity | 1000 tests |
| Interface Options | RS-232, USB, Ethernet, Balance Integration, Printer Port |
| Operating System | Linux-based embedded controller |
| Calibration & Reporting | Automatic correction for fuse wire, nitric acid formation, sulfur oxidation, and hydrogen combustion enthalpy |
| Brand | Parr |
|---|---|
| Origin | USA |
| Model | 6400 |
| Temperature Range | 0–40 °C |
| Temperature Resolution | 0.0001 °C |
| Precision | ±0.1% RSD |
| Single-Sample Test Time | 6–7 min |
| Heat Capacity | 33,000 J/K |
| Outer Water Jacket Volume | 2 L |
| Inner Water Bucket Volume | 342 mL |
| Oxygen Filling | Fully Automated |
| Jacket Water Filling | Fully Automated |
| Pressure Release | Automated |
| Bomb Rinsing | Automated |
| Data Storage Capacity | 1,000 tests |
| Connectivity | Ethernet |
| Display | Touchscreen LCD |
| Measurement Principle | Isoperibol (Constant-Temperature Jacket) |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | PCY-III-X |
| Price Range | USD 1,400–7,200 (FOB) |
| Temperature Range (°C) | -30 to 1700 (selectable configurations) |
| Heating Rate (°C/min) | 0.1–20 (standard setpoint: 5) |
| Temperature Accuracy (°C) | ±1 |
| Sample Diameter (mm) | 5–10 |
| Sample Length (mm) | ≤50 |
| Measurement Range | 5 mm |
| Resolution | 1 µm (optional 0.1 µm digitization) |
| Atmosphere Options | Air, Vacuum (down to 10⁻¹ mbar), Static/Dynamic Inert (N₂, Ar), Reactive Gas (customizable) |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | PCY-SP |
| Pricing | Available Upon Request |
| Max Operating Temperature | 1000 °C (1200 °C Furnace Limit) |
| Temperature Control | Dual K-Type Thermocouples (Control + Sample Sensing) |
| Control System | Intelligent PID with Programmable Ramp Rates & Segmented Profiles |
| Temperature Accuracy | ±1 °C |
| Heating Element | Ni–Cr (2080) Resistance Wire (Theoretical Max: 1350 °C) |
| Displacement Detection | Optical Grating-Based Linear Encoder |
| Displacement Accuracy | ±0.5% FS |
| Data Acquisition | Real-Time PC-Based System |
| Software Platform | Windows 7/XP Compatible (Bilingual UI), ASTM C338–Compliant Workflow & Reporting Engine |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer | PerkinElmer, Inc. |
| Model | DMA 8000 |
| Instrument Type | Dynamic Mechanical Analyzer (DMA/DMTA) |
| Temperature Range | –196 °C to 600 °C (with LN₂ cryogenic cooling) |
| Frequency Range | 0.01–300 Hz |
| Cooling Rate | ≤15 min from ambient to –190 °C |
| Liquid Nitrogen Consumption | ~1 L per typical low-temperature DMA run |
| Sample Modes | Dual/Triple Cantilever, 3-Point Bending, Tension, Compression, Shear, and TMA Mode |
| Humidity Control Range | 10–90 % RH (optional humidity generator) |
| Optical Access | Quartz furnace viewport for in-situ visual monitoring and UV-curable sample testing |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | DSC 4000 / DSC 6000 |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | –100 °C to 600 °C (with optional cryogenic and high-temp accessories) |
| Temperature Accuracy | ±0.1 °C (traceable to NIST standards) |
| Heating/Cooling Rate | 0.1–100 K/min (programmable in 0.1 K/min increments) |