Empowering Scientific Discovery

Thermo Fisher Scientific (China) Co., Ltd. Group Booth

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher Scientific
OriginUSA
ModelThermo Scientific 2120XP
Detection Limit25 ppb Ca²⁺
Measurement PrincipleCalcium-Selective Electrode (CSE) with pH-Buffered Sample Conditioning
DisplayBacklit LCD
Calibration MethodDual-Standard Known Addition (DKA)
Optional ChannelspH or Conductivity (second channel)
CommunicationDigital I/O and Modbus RTU/ASCII support
Maintenance DesignNo moving parts, no reagent pumps, no consumable dosing systems
ComplianceDesigned for continuous operation in industrial water treatment environments per ASTM D1066 and ISO 5667-3 guidelines
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
ModelThermo Scientific 2109XP
Detection Limit10 ppb F⁻
Measurement PrinciplePotentiometric using Solid-State Fluoride Ion-Selective Electrode (ISE)
DisplayBacklit LCD
Calibration MethodDual-Standard Known Addition (DKA)
Optional ChannelspH or Conductivity
CommunicationDigital Modbus RS-485 / 4–20 mA analog output
MaintenanceNo reagent pumps or moving parts
ComplianceDesigned for continuous compliance monitoring per EPA Method 300.0 and ISO 10304-1
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
ModelThermo Scientific 2117XP
Detection Limit0.1 ppm Cl⁻
Measurement PrinciplePotentiometric with Chloride-Selective Electrode (CSE)
DisplayBacklit LCD
Calibration MethodDKA (Two-Point Known Addition)
Optional ChannelspH or Conductivity
CommunicationDigital Module Support (RS-485/Modbus RTU)
ComplianceDesigned for continuous online water quality monitoring in industrial process and utility applications
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher Scientific
OriginUSA
Model2117HL
Measurement Range75–1000 ppm Cl⁻
PrinciplePotentiometric measurement using solid-state chloride-selective electrode
Reagent-Free OperationYes
DisplayBacklit LCD with graphical interface
Calibration MethodDKA (Dual-Point Known Addition)
Response Time (t₉₀)< 2 minutes
Maintenance RequirementsNo pumps, no reagents, no moving parts
ComplianceDesigned for continuous industrial process monitoring in accordance with ASTM D4192, ISO 9297, and EPA Method 325B (adapted for on-line chloride detection)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher Scientific
OriginUSA
Manufacturer TypeAuthorized Distributor
Product CategoryImported Instrument
ModelThermo Scientific 6800
PricingAvailable Upon Request
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0