| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Thermo Scientific 3300 |
| Instrument Type | Online Analyzer |
| Detection Principle | Photometric Method (Colorimetric) |
| Target Metals | Dual-Parameter / Multi-Parameter (e.g., Cd, Cr, Cu, Ni, Pb, Zn, As, Hg) |
| Accuracy/Precision | ±10% of Full Scale |
| Resolution | 0.001 mg/L (ppb-level configurable per analyte) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | 2240 |
| Instrument Type | Online Analyzer |
| Measurement Principle | Gas-Sensing Electrode (Ammonia-Selective Electrode) |
| Measurement Range | 0–50.0 mg/L as NH₃–N |
| Accuracy | ±5% of reading or ±0.10 mg/L (whichever is greater) |
| Detection Limit | 0.001 mg/L |
| Analysis Time | <10 minutes per sample |
| Batch Throughput | <10 minutes per measurement |
| Display Interface | Bilingual (English & Chinese) |
| Communication Interfaces | Standard RS-232 and 0–20 mA analog output |
| Self-Diagnostics | Integrated system health monitoring |
| Flow Path | Patented corrosion-resistant fluidic architecture |
| Maintenance Automation | Programmable auto-cleaning and auto-calibration cycles |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | 2230XP |
| Type | Online Analyzer |
| Detection Range | 0–5000 ppb (SiO₂) |
| Low-Range Accuracy | Optimized for 0–500 ppb |
| Reagent Consumption | 0.2 mL per reagent per analysis |
| Light Source | 810 nm LED (filter-free, fiber-optic-free) |
| Sample Temperature Control | Integrated heater maintains 25 °C |
| Zero Calibration | Performed before each analysis cycle |
| Pump Maintenance Interval | Every 6 months |
| Power Input | 100–240 VAC, 50–60 Hz |
| Enclosure Rating | NEMA 4 |
| Data Storage | 31 days of calibration and measurement logs |
| Display | Backlit LCD with multi-parameter status view |
| Installation | Panel-mount or wall-mount compatible |
| Compliance | Designed for continuous operation in power generation, semiconductor, and pharmaceutical water monitoring environments |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Thermo Scientific™ TSTIO1000 |
| Instrument Type | Online Analyzer |
| Measurement Principle | Electrochemical Sensing (pH & residual chlorine), 90° Nephelometric Light Scattering (turbidity) |
| Measured Parameters | pH, Residual Chlorine, Turbidity, Temperature |
| Range | 0.01–20 ppm (residual chlorine) |
| Accuracy | ±0.01 ppm or ±2% of full scale (residual chlorine) |
| Repeatability | ≤2% RSD |
| Resolution | 0.01 ppm (residual chlorine) |
| Detection Limit | 0.01 ppm (residual chlorine) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | 2295 |
| Instrument Type | Online Analyzer |
| Detection Range | 0.2–50 ppm PO₄³⁻ (auto-ranging) |
| Reagent Consumption | 0.2 mL per reagent per analysis |
| Sample Temperature Control | Heated to 25 °C for low-temperature samples |
| Light Source | High-stability LED (no filters or optical fibers) |
| Pump Maintenance Interval | Every 6 months |
| Display | Backlit LCD with full status and measurement data |
| Data Storage | 31 days of calibration & analysis logs (timestamped, parameter-rich) |
| Enclosure Rating | NEMA 4 |
| Power Input | 100–240 VAC, 50–60 Hz |
| Installation | Panel-mount or wall-mount compatible |
| Auto-Restart Function | Configurable 30-minute timeout after STOP command |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | Thermo Scientific 2120XP |
| Detection Limit | 25 ppb Ca²⁺ |
| Measurement Principle | Calcium-Selective Electrode (CSE) with pH-Buffered Sample Conditioning |
| Display | Backlit LCD |
| Calibration Method | Dual-Standard Known Addition (DKA) |
| Optional Channels | pH or Conductivity (second channel) |
| Communication | Digital I/O and Modbus RTU/ASCII support |
| Maintenance Design | No moving parts, no reagent pumps, no consumable dosing systems |
| Compliance | Designed for continuous operation in industrial water treatment environments per ASTM D1066 and ISO 5667-3 guidelines |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Model | Orion™ 3106 COD |
| Instrument Type | Online Analyzer |
| Measurement Principle | Potassium Dichromate Digestion with Photometric Detection |
| Wavelength | 450 nm |
| Measurement Ranges | 20–200–800–2000 mg/L COD |
| Accuracy | ±5 mg/L (for values <50 mg/L) or ±10% (for values >50 mg/L) |
| Repeatability | ≤5% |
| Limit of Detection (LOD) | 4 mg/L |
| Cycle Time | 40 min per sample |
| Sample Throughput | 500 samples per batch |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | Thermo Scientific 2109XP |
| Detection Limit | 10 ppb F⁻ |
| Measurement Principle | Potentiometric using Solid-State Fluoride Ion-Selective Electrode (ISE) |
| Display | Backlit LCD |
| Calibration Method | Dual-Standard Known Addition (DKA) |
| Optional Channels | pH or Conductivity |
| Communication | Digital Modbus RS-485 / 4–20 mA analog output |
| Maintenance | No reagent pumps or moving parts |
| Compliance | Designed for continuous compliance monitoring per EPA Method 300.0 and ISO 10304-1 |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | Thermo Scientific Orion 2210AM |
| Instrument Type | Online Analyzer |
| Measurement Principle | Colorimetric Method (Indophenol Blue) |
| Measurement Ranges | 0.01–2 mg/L, 0.05–10 mg/L, 0.5–50 mg/L, 5–500 mg/L (as N) |
| Accuracy | ±5% or ±0.01 mg/L (whichever is greater) within 0.01–50 mg/L |
| Detection Limit | 0.01 mg/L (as N) |
| Analysis Time | ≤30 minutes per cycle |
| Temperature Control | Integrated thermostatically controlled cuvette with magnetic stirring |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | Chlorine XP |
| Instrument Type | Online Analyzer |
| Measurement Principle | DPD Spectrophotometry |
| Measured Parameters | Free Chlorine, Total Chlorine, Combined Chlorine |
| Range | 0.01–10 ppm |
| Accuracy | ±3% of reading |
| Repeatability | ±5% |
| Resolution | 0.01 ppm |
| Detection Limit | 0.01 ppm |
| Reagent Consumption | 0.03 mL per analysis |
| Reagent Shelf Life | 24 months (unopened) |
| Environmental Rating | IP65 (NEMA 4) |
| Communication Interface | RS-485 |
| Certifications | EPA Compliant, CSA Certified, ISO 9001 Certified |
| Operating Temperature Range | Supports sample temperatures down to 4 °C |
| Origin | Imported |
|---|---|
| Manufacturer Type | Distributor |
| Model | Thermo Scientific Water Quality Analyzer |
| Instrument Type | Laboratory Water Quality Analyzer |
| Price Range | USD 70,000 – 98,000 (based on configuration and regional import duties) |
| Key Compliance | ASTM D1293, ISO 7888, ISO 5667-3, USP <643>, EPA Methods 4500-OC, 4500-BOD, 4500-P, 4500-Cl⁻ |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | Thermo Scientific AQ4700 |
| Instrument Type | Online |
| Biological Indicator | Bioluminescent Bacteria |
| Detection Time | 5 min |
| Compliance | ISO 11348 |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Thermo Scientific 3131 |
| Pricing | Available Upon Request |
| Measurement Principle | Potassium Permanganate Oxidation with ORP Endpoint Detection |
| Range | 0–20 / 0–100 / 0–200 mg/L KMnO₄ (customizable extended ranges available) |
| Repeatability | ≤ ±3% RSD |
| Accuracy | ±3% of reading |
| Limit of Detection (LOD) | ≤ 0.2 mg/L |
| Resolution | 0.001 mg/L |
| Analysis Time per Sample | < 60 minutes |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | Thermo Scientific 2117XP |
| Detection Limit | 0.1 ppm Cl⁻ |
| Measurement Principle | Potentiometric with Chloride-Selective Electrode (CSE) |
| Display | Backlit LCD |
| Calibration Method | DKA (Two-Point Known Addition) |
| Optional Channels | pH or Conductivity |
| Communication | Digital Module Support (RS-485/Modbus RTU) |
| Compliance | Designed for continuous online water quality monitoring in industrial process and utility applications |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (China-manufactured) |
| Model | Orion 8006cX Online COD Analyzer |
| Instrument Type | Online Analyzer |
| Measurement Range | 0–1000 mg/L and 1000–5000 mg/L |
| LOD | 10 mg/L |
| Chloride Interference Tolerance | up to 5000 mg/L |
| Compliance | HJ/T 399–2007, HJ 377–2019, HJ 35X–2019 |
| Certification | CCEP (China Environmental Protection Product Certification) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | 2117HL |
| Measurement Range | 75–1000 ppm Cl⁻ |
| Principle | Potentiometric measurement using solid-state chloride-selective electrode |
| Reagent-Free Operation | Yes |
| Display | Backlit LCD with graphical interface |
| Calibration Method | DKA (Dual-Point Known Addition) |
| Response Time (t₉₀) | < 2 minutes |
| Maintenance Requirements | No pumps, no reagents, no moving parts |
| Compliance | Designed for continuous industrial process monitoring in accordance with ASTM D4192, ISO 9297, and EPA Method 325B (adapted for on-line chloride detection) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Model | 3110TP |
| Application | Online Water Quality Monitoring |
| Measured Parameter | Total Phosphorus (TP) |
| Measurement Range | 0–1 / 0–2 / 0–10 / 0–50 mg/L |
| Accuracy | <5% for standard solutions |
| Detection Limit | 0.01 mg/L |
| Resolution | < ±5% of Full Scale |
| Instrument Type | Online Automated Analyzer |
| Compliance Context | Designed for continuous operation in compliance with ISO 15681-1 (Water quality — Determination of phosphorus — Part 1: Spectrophotometric determination after digestion) and supports GLP/GMP data integrity requirements via audit-trail-capable software |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | Thermo Scientific 2118XP |
| Type | Online Analyzer |
| Detection Range | 0–200 ppb |
| Sensor Principle | Iodide-Selective Electrode (ISE) |
| Display | Backlit LCD |
| Compliance | Designed for ASTM D4356, ISO 10523, and USP <645> water quality monitoring environments |
| Communication Options | Optional digital communication module (Modbus RTU/ASCII, 4–20 mA analog output) |
| Expandability | Optional second channel for pH or conductivity measurement |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | 2117LL |
| Detection Limit | 1.5 ppb Cl⁻ |
| Measurement Principle | Potentiometric Chloride-Selective Electrode (CSE) |
| Calibration | Dynamic 1–3-point calibration with integrated pH adjustment |
| Compliance | Designed for continuous online monitoring in high-purity water systems |
| Application Environment | Semiconductor-grade UPW, boiler feedwater, RO permeate, condensate, seawater-cooled condenser leak detection |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | Thermo Scientific 3100 VA |
| Instrument Type | Online Water Quality Analyzer |
| Electrode Material | Mercury-Free Working Electrode |
| Measurement Principle | Chronopotentiometric Anodic Stripping Voltammetry (ASV) |
| Compliance | Designed for EPA Method 300.1 / ISO 10566 / ASTM D7282-18 compatibility |
| Software | Embedded OS with bilingual (English/Chinese) interface |
| Maintenance | Low-consumption flow-injection system with self-diagnostic and auto-recovery functions |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Model | Orion 8010cX |
| Instrument Type | Online Analyzer |
| Measurement Principle | Salicylate Spectrophotometry |
| Measurement Ranges | (0.02–2) mg/L |
| Accuracy | ±3% of reading ±0.04 mg/L (0.02–2 mg/L) |
| Detection Limit | 0.02 mg/L |
| Analysis Time | ≤30 min |
| Resolution | 0.001 mg/L (<100 mg/L) |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤95% RH (non-condensing) |
| Sample Flow Rate | 50–1000 mL/min |
| Sample Pressure | 1–5 bar |
| Sample Temperature | 5–50 °C |
| Sample pH | 4–9 |
| Max. Turbidity (NTU) | <30 |
| Max. Color (Pt-Co) | <180 |
| Enclosure Rating | IP65 |
| Dimensions (W×H×D) | 450 × 737 × 322 mm |
| Weight | 40 kg |
| Power Supply | 100–240 VAC, 100 W, 50/60 Hz |
| Analog Outputs | Two 4–20 mA (max. 900 Ω load) |
| Digital Interface | RS485 |
| Relay Outputs | Two dry contacts (2 A @ 250 VAC) |
| Regulatory Compliance | cTUVus, CB, CE-LVD, RCM, FCC, CE-EMC, CE-RoHS, REACH, China RoHS |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Thermo Scientific 6800 |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Dual Star |
| Instrument Type | Laboratory Water Quality Analyzer |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | Orion 3150 |
| Instrument Type | Online Analyzer |
| Measurement Principle | Spectrophotometry (UV-Vis) |
| Measuring Parameters | Total Phosphorus (TP) and Total Nitrogen (TN) |
| Range | 0–2 / 0–10 / 0–50 mg/L (user-selectable ranges per parameter) |
| Accuracy | ±5% of reading |
| Detection Limit | 0.005 mg/L |
| Resolution | 0.01 mg/L |
| Light Source (TN module) | Xenon flash lamp (rated for >10⁸ flashes) |
| Sample Handling | Integrated digestion-colorimetric cell with automated reagent dosing and thermal digestion |