| Brand | Thermo Scientific |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | 6000 VOC |
| Detection Principle | Flame Ionization Detection (FID) |
| Instrument Type | Online Gas Analyzer |
| Typical Configuration | Multi-Component VOC CEMS |
| Measurement Range | 0–5000 ppm (as methane or NMHC) |
| Accuracy | ±1% Full Scale or ±0.1 ppm |
| Response Time | ≤60 s (for NMHC, T90) |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | Thermo |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Thermo Scientific 55i |
| Detection Principle | Gas Chromatography (GC) with Flame Ionization Detection (FID) |
| Instrument Type | Online Continuous Emission Monitor |
| Configuration | Dual-Channel GC-FID for Simultaneous CH₄ and NMHC Quantification |
| Detection Range | 0–5/50/500 ppm |
| Resolution | 0.050 ppm CH₄ |
| Accuracy | ±2% of reading or ±50 ppb (whichever is greater) |
| Response Time (t₉₀) | 70 s |
| Zero Noise | 0.025 ppm RMS (300-s averaging) |
| Span Drift (24 h) | <2% of full scale |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Shanghai, China |
| Model | Thermo Scientific 5900 VOCs |
| Detection Principle | Gas Chromatography with Flame Ionization Detection (GC-FID) |
| Instrument Type | Online Continuous Analyzer |
| Detection Range | NMHC 0–5 ppm |
| Accuracy | ≤ ±10% |
| Response Time | ≤ 15 min |
| Compliance | Designed for EN 13526, EPA Method 25A, ISO 11890-2, and US EPA Compendium Method TO-17 (with preconcentration) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TVC-55 |
| Detection Principle | Gas Chromatography with Flame Ionization Detection (GC-FID) |
| Instrument Type | Online Analytical System |
| Typical Configuration | Integrated CH₄/NMHC Dual-Channel Analyzer |
| Measurement Range | 0–5/50/500 ppm, 0–10/100/1000 ppm, 0–20/200/2000 ppm, or 0–50/500/5000 ppm (user-selectable full-scale ranges) |
| Resolution | 0.025 ppm RMS (300-second averaging time) |
| Accuracy | ±2.0% of reading or ±50 ppb (whichever is greater) |
| Response Time (T₉₀) | ~70 seconds |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | TVA2020C |
| Detector Types | Flame Ionization Detector (FID) & Photoionization Detector (PID) |
| Instrument Type | Intrinsically Safe Portable Analyzer |
| Detection Range | FID 1.0–30,000 ppm methane |
| Resolution | FID 0.5 ppm methane |
| Accuracy | FID ±10% of reading or ±0.1 ppm (whichever is greater) over 1.0–10,000 ppm |
| Response Time | <3.5 s |
| Compliance | ATEX Zone 2, ANSI/CSA Class I & II Division 2 |
| Connectivity | Bluetooth 4.0 LE |
| Data Logging | Internal non-volatile memory with user-configurable sampling intervals and path-based tagging |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Sentinel Pro |
| Detection Principle | Gas Chromatography-Mass Spectrometry (GC-MS) Coupled Online Sampling |
| Instrument Type | Continuous Online Analyzer |
| Typical Configuration | Multi-Channel VOC Monitoring System |
| Detection Range | 0.01–1 ppm (v/v) |
| Resolution | Dual Slit Selection — 60 (1 mm slit), 20 (4 mm slit) |
| Accuracy | <0.1% relative error |
| Response Time | ≤15 min for up to 100 sampling points |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | 6000 VOC |
| Detection Principle | Flame Ionization Detection (FID) |
| Instrument Type | Online Analyzer |
| Typical Configuration | Multi-Component VOC CEMS |
| Measurement Range | 0–5000 ppm (as methane or NMHC) |
| Accuracy | ±1% F.S. or ±0.1 ppm |
| Response Time | ≤60 s (for NMHC) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Taiwan |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (China-sourced) |
| Model | TVC-5800 |
| Detection Principle | Gas Chromatography (GC) with Flame Ionization Detection (FID) |
| Instrument Type | Online Continuous Analyzer |
| Typical Configuration | Multi-component Speciated VOC Analyzer |
| Measurement Range | 0–50 ppm / 500 ppm / 5,000 ppm / 5% / 50% (as CH₄) |
| Resolution | 0.05 ppm |
| Accuracy | ±1% of Full Scale or ±0.1 ppm (whichever is tighter) |
| Response Time | ≤60 seconds (T₉₀) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Imported |
| Model | Thermo Scientific 5800 |
| Detection Principle | Gas Chromatography–Flame Ionization Detection (GC-FID) |
| Instrument Type | Online Analyzer |
| Typical Configuration | Multi-component VOC Analyzer |
| Detection Range | 0–50 ppm / 500 ppm / 5,000 ppm / 50,000 ppm / 500,000 ppm (as methane) |
| Resolution | 50 ppb |
| Accuracy | ±1% of full scale or ±0.1 ppm (whichever is greater) |
| Response Time | <1 minute for NMHC analysis |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China-manufactured) |
| Model | 5900-D |
| Pricing | Upon Request |
| Detection Principle | Gas Chromatography coupled with Pre-concentration and Dual Detectors (FID + FPD) |
| Instrument Type | Online Continuous Analyzer |
| Typical Configuration | Multi-Component VOC Analyzer |
| Detection Range | Direct Sampling: 0–500 / 1,000 / 2,000 / 3,000 ppm (as benzene) |
| Pre-concentrated Sampling | 0–50 / 100 / 200 / 300 / 500 ppm (as benzene) |
| Resolution | Direct Sampling (benzene-equivalent): 25 ppb (v/v) |
| Pre-concentrated Sampling (benzene-equivalent) | 30 ppt (v/v) |
| Accuracy | ≤2% (benzene) |