| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Sievers 900 |
| Price Range | USD 13,500 – 40,500 (FOB) |
| Product Category | TOC Analyzers |
| Operational Age | 3–4 Years |
| Warranty | 12 Months |
| Brand | SofTA |
|---|---|
| Origin | USA |
| Model | Model 100 ELSD9 |
| Detection Principle | Evaporative Light Scattering |
| Light Source | 670 nm laser (<5 mW) |
| Detection Limit | 10 ng |
| Dynamic Range | 4 orders of magnitude |
| RSD | <2% |
| Operating Nebulizer Temperature | 55 °C |
| Gas Requirement | 50 psi inert gas (N₂), ~2.5 SLPM |
| Flow Rate Compatibility | 0–5 mL/min |
| Power | 120/240 VAC, 50/60 Hz, 600 W |
| Dimensions | 24.9 × 45.7 × 29.2 cm (W×D×H) |
| Weight | 10.4 kg (23 lbs) |
| Interface | RS-232 |
| Display | 2×20-character VFD |
| Housing Materials | Stainless steel, electroplated chrome, PTFE |
| Brand | SOTAX |
|---|---|
| Origin | Switzerland |
| Model | AT 7smart |
| Dissolution Vessels | 7 |
| Bath Volume | 17.5 L |
| Temperature Range | 20–60 °C |
| Temperature Accuracy | ±0.1 °C |
| Rotation Speed Range | 25–250 rpm |
| Pump Options | CP Xtend or CP 7-35 |
| Autosampler Compatibility | C 613 / C 615 |
| Operational Age | 3–4 years |
| Warranty | 6 months |
| Compliance | USP <711>, Ph. Eur. 2.9.3, JP 17 |
| Brand | SOTAX |
|---|---|
| Origin | Switzerland |
| Model | AT Xtend |
| Instrument Age | 4 years |
| Warranty | 6 months |
| Regulatory Compliance | 21 CFR Part 11 compliant software control |
| USP Apparatus Compatibility | USP 1 (basket), USP 2 (paddle), USP 5 (flow-through cell), USP 6 (reciprocating cylinder) |
| Automation Capacity | Up to 8 dissolution vessels, unattended operation from medium preparation to data processing |
| Modular Architecture | Fully scalable Xtend platform |
| Operating Mode | Manual or motorized vertical bath closure with quick-lock system |
| Vessel Configuration | 6–8 vessel water bath tank |
| Software | WinSOTAXplus v5.x or later (validated, audit-trail enabled) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | 3100 |
| Price | USD 14,000 (FOB Beijing) |
| Product Category | Purge & Trap Autosampling System |
| Service Life | Refurbished Unit — Verified Operational History |
| Warranty | 6 Months Limited Hardware Warranty |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Phoenix 8000 |
| Warranty | 6 months |
| Operational Age | 4 years |
| Detection Principle | UV-Persulfate Oxidation + NDIR |
| Detection Range | 2 ppb–10,000 ppm (TOC) |
| Accuracy | ±2% RSD or ±1 ppb or ±0.02 µg |
| Sample Volume | Up to 20 mL |
| Analysis Time | ~15 min (triplicate) |
| Detector | Non-Dispersive Infrared (NDIR), Linearized Signal Processing |
| Compliance | ASTM D7573, ISO 8245, USP <643>, EPA Method 415.3 |
| Software Interface | Windows-based Apollo Control Suite (v3.x compatible) |
| Sample Introduction | Automated syringe injection via PC-controlled autosampler |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Tekmar Velocity XPT |
| Price Range | USD $13,500 – $40,500 (FOB) |
| Product Category | Chromatography Systems |
| Operational Age | 1–2 years |
| Warranty | 12 months comprehensive parts & labor |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Tekmar Velocity XPT |
| Warranty | 6 Months |
| Instrument Age | 4–5 Years |
| Power Supply | 220–240 V, 50/60 Hz, 4 A, 920 W |
| Operating Temperature | 10–30 °C |
| Relative Humidity | 10–90 % RH |
| Panel Corrosion Resistance | pH 1–10 |
| Weight | 12.3 kg |
| Dimensions | 21 cm × 44.5 cm × 48 cm |
| Purge Tube Options | 5 mL or 25 mL fritted U-tube, 5 mL or 25 mL needle-type tube |
| Trap Temperature Range | Up to 350 °C (heating), ≥127 °C/min cooling rate |
| Desorption Rate | 800 °C/min |
| Transfer Line Temp | Up to 300 °C (PEEK & stainless steel) |
| Valve Temp | Up to 300 °C (24 V solenoid valves) |
| DryFlow Moisture Trap | Ambient to 350 °C, removes ~90 % water without compromising polar analytes |
| Flow Control | Electronic Mass Flow Controller (MFC), 5–500 mL/min across purge/dry-purge/bake modes |
| Leak Detection | Integrated electronic pressure sensor with automated leak test & diagnostic mode |
| Foam Monitoring | Optional foam sensor and defoaming module |
| Cooling Time Reduction | 25 % faster post-bake trap cooldown |
| Cycle Time | ≤15 min per run (with 11-min purge) |
| Sample Throughput | Up to 100 % increase vs. prior-generation systems |
| Software | Tekmar TO-15 / EPA Method 502.2 / 524.2 / 8260-compliant control suite with audit trail, method validation logging, and GLP/GMP-ready data integrity features |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Tekmar XPT |
| Price | ¥80,000 CNY |
| Product Category | Other |
| Service Life | 3–4 Years |
| Warranty | 6 Months |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | TEKMAR72 |
| Warranty | 6 months |
| Condition | Refurbished & Fully Tested |
| Compliance | ASTM D5024, EPA Method 502.2 / 524.2 / 624 / 8260D |
| Software | Atomx Connect v3.x (FDA 21 CFR Part 11 compliant audit trail enabled) |
| Sample Throughput | Up to 48 samples unattended |
| Detection Limit | Sub-ppt (ng/L) for volatile organic compounds (VOCs) in aqueous matrices |
| Brand | Teledyne Tekmar |
|---|---|
| Origin | USA |
| Model | SolaTEK 72 |
| Instrument Type | Purge and Trap Autosampler for Gas Chromatography |
| Age | 4 years |
| Warranty | 6 months |
| Compliance | Designed to meet EPA Methods 502.2, 524.2, 524.4, 8260D, and ASTM D7137 |
| Software Compatibility | Compatible with standard GC control platforms (e.g., Thermo Chromeleon, Agilent OpenLab, Waters Empower) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Accela, FL Plus |
| Product Category | Chromatography |
| Operational Age | 3–4 years |
| Warranty | 6 months |
| Instrument Model | Accela, FL Plus |
| Instrument Age | 3 years |
| Brand | Thermo Fisher |
|---|---|
| Origin | Canada |
| Model | AS100 |
| Product Category | Chromatography |
| Usage Duration | 5–7 years |
| Warranty | 6 months |
| Condition | Refurbished & Fully Tested |
| Sample Capacity | 120 vials (3 programmable movable trays) |
| Precision Injection | <0.5% RSD |
| Needle Height Adjustment | Programmable in 0.1 mm increments |
| Carryover | Typically <400 nL |
| Wash Volume | Adjustable, residual contamination <0.01% |
| Certification | Factory-tested and verified per SpectraLab Scientific QC protocol |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AS-AP |
| Price Range | USD 6,800–13,600 |
| Product Category | Chromatography |
| Operational Age | 3–4 years |
| Warranty | 6 months |
| Brand | Thermo Fisher |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AS-DV |
| Price Range | USD 1,400–7,000 (FOB) |
| Product Category | Chromatography |
| Operational Age | 3–4 years |
| Warranty | 6 months |
| Brand | Thermo Fisher |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AS-HV |
| Price Range | USD $13,500 – $40,500 (est. FOB) |
| Product Category | Chromatography |
| Operational Age | 4–5 years |
| Warranty | 6 months |
| Brand | Thermo Fisher |
|---|---|
| Origin | Canada |
| Model | ASE 350 |
| Sample Capacity | 1–100 g |
| Operating Temperature | up to 200 °C |
| Maximum Pressure | 1500 psi |
| Pump Flow Rate | 70 mL/min |
| Solvent Channels | 3 |
| Extraction Vessel Sizes | 1, 5, 10, 22, 34, 66, and 100 mL |
| Throughput | Up to 24 unattended extractions |
| Solvent Consumption Reduction | 50–90% vs. Soxhlet |
| Warranty | 1 year |
| Instrument Age | 4 years |
| Compliance | Designed for ASTM D7689, EPA Method 3545A, USP <2021>, ISO 14507 |
| Brand | Thermo Fisher |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Ultimate 3000 |
| Price Range | USD 13,500 – 40,500 (FOB) |
| Product Category | Chromatography |
| Operational Age | 4–5 years |
| Warranty | 6 months |
| Configuration | HPG-3200A Quaternary Pump, WPS-3000SL Analytical Autosampler, TCC-3000 Column Compartment, UVD-340U UV-Vis Detector, SRD-3200 Solvent Rack |
| Refurbishment Standard | ISO/IEC 17025-aligned functional validation and performance qualification |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | DSQ II |
| Mass Spectrometer Type | Single Quadrupole |
| Usage Duration | 3–4 years (Total Service Life: ~7 years) |
| Warranty | 6 months |
| Vacuum System | Dual-stage (Mechanical Pump + High-Performance Turbomolecular Pump) |
| Ion Source | Electron Ionization (EI), DuraBrite™ Design, Max Temp 300 °C |
| Mass Range | 1–1050 amu |
| Scan Speed | Up to 11,000 amu/sec |
| Sensitivity (EI, Full Scan) | ≥200:1 S/N for 1 pg Octafluoronaphthalene (OFN) |
| Resolution | Unit Mass |
| Detector | DynaMax™ EPT Electron Multiplier (Dynamic Linear Range: 10⁸) |
| GC Interface Max Temp | ≥300 °C |
| Software | Xcaliber™ + QuanLab™ Quantitation Suite |
| Compliance | Fully Compatible with ASTM D5845, EPA Methods 8270/8330, USP <621>, and GLP/GMP Data Integrity Requirements (21 CFR Part 11-ready audit trail) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Finnigan Surveyor |
| Product Category | Chromatography |
| Operational Age | 3–4 years |
| Warranty | 6 months |
| Instrument Model | Finnigan Surveyor |
| Instrument Usage Duration | 3 years |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | Finnigan Surveyor Plus |
| Category | Liquid Chromatograph |
| Usage Duration | 3–4 years |
| Warranty | 6 months |
| Compliance | FDA 21 CFR Part 11 (via ChromQuest CDS) |
| Detector Configuration | UV/Vis, Refractive Index, PDA with LightPipe™ technology |
| Pump Type | Quaternary LC pump |
| Integrated Column Oven | Yes |
| Software | ChromQuest Chromatography Data System |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Focus GC |
| Product Category | Chromatography |
| Usage Duration | 4–5 years |
| Warranty Period | 6 months |
| Instrument Model | Focus GC |
| Instrument Age | 4 years |
| Brand | Thermo Fisher |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Focus |
| Product Category | Chromatography |
| Operational Age | 5–7 Years |
| Warranty | 6 Months |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | iCAP 6000 |
| Wavelength Range | 166–847 nm |
| Spectral Resolution | 7 pm at 200 nm |
| Detector | High-performance solid-state CID detector (CID86 chip) |
| RF Generator | 27.12 MHz solid-state |
| Optical System | Echelle spectrometer with 52.91 lines/mm ruled grating, 383 mm focal length, UV-grade fused silica cross-disperser prism (9.5°) |
| Nebulization | Concentric glass nebulizer + cyclonic spray chamber + EMT torch assembly (1.5 mm radial / 2.0 mm dual-view quartz center tube) |
| Peristaltic Pump | 4-channel micro-peristaltic pump, 0–125 rpm |
| Dimensions (W×D×H) | 840 × 750 × 590 mm |
| Operational Age | 6–8 years |
| Warranty | 6 months |
| Compliance | ASTM D1976, ISO 11885, USP <232>/<233>, EPA Methods 200.7, 200.8, 6010D |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | iCAP 6000 |
| Instrument Type | Inductively Coupled Plasma Optical Emission Spectrometer (ICP-OES) |
| Age | 6–8 years |
| Warranty | 1 year |
| Category | Used Analytical Instrument |
| Regulatory Compliance | Designed to meet ASTM D5193, ISO 11885, USP <232>/<233>, and EPA Methods 200.7, 200.8, and 6010D requirements |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | iCAP 7000 |
| Product Category | Optical Emission Spectrometer (ICP-OES) |
| Instrument Age | 6–8 years |
| Warranty | 6 months |
| Compliance | ASTM D5185, ISO 11885, USP <232>/<233>, EPA Methods 200.7 & 6010D |
| Detection Limit | Sub-ppb (typical for most elements) |
| Plasma Observation | Radial and Axial |
| Detector | Charge Injection Device (CID) |
| RF Generator | Solid-State, 27.12 MHz |
| Optical System | High-Resolution Simultaneous Monochromator with Precision Temperature Control |
| Sample Introduction | Modular, Auto-Connecting Gas Lines, Interchangeable Nebulizers & Spray Chambers |
| Software Platform | Thermo Scientific Qtegra Intelligent Scientific Data Solution (ISDS) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | iCAP 7400 DUO |
| Instrument Age | 9 years |
| Warranty | 1 year |
| Detection Principle | Inductively Coupled Plasma Optical Emission Spectrometry |
| Regulatory Compliance | Designed to support ASTM D5185, ISO 11885, USP <232>/<233>, and EPA Methods 200.7, 200.8, and 6010D |
| Software Platform | Thermo Scientific Qtegra Intelligent Scientific Data Solution (ISDS) |
| Dual-View Configuration | Radial and Axial Simultaneous Viewing |
| RF Generator | Solid-State, 27.12 MHz, 1.5 kW |
| Nebulizer | Glass concentric or SeaSpray™ high-salt nebulizer (configurable) |
| Detector | Advanced solid-state CCD array with thermoelectric cooling |
| Resolution | ≤0.007 nm at 200 nm |
| Detection Limits | Sub-ppt to low-ppt range for most elements (e.g., 0.04 ng/mL for Mg II 280.270 nm, axial view) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | IRIS Intrepid II XDL |
| Instrument Type | Inductively Coupled Plasma Optical Emission Spectrometer (ICP-OES) |
| Age | 4–5 years |
| Warranty | 6 months |
| Configuration | Fully Tested & Refurbished |
| Compliance | ASTM D1976, ISO 11885, USP <232>/<233>, EPA Methods 200.7 & 6010D |
| Software | TEVA™ v4.x (FDA 21 CFR Part 11–ready audit trail enabled) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | IRIS Intrepid II XSP |
| Focal Length | 381 mm |
| Wavelength Range | 165–1050 nm |
| Spectral Resolution | 0.005 nm at 200 nm |
| Stray Light | < 0.3 ppm (measured at As 193.696 nm with 10,000 ppm Ca) |
| RF Generator Frequency | 27.12 MHz |
| Frequency Stability | ±0.004% |
| RF Power Output | 750–1500 W (continuously adjustable) |
| Power Stability | ±0.01% |
| Plasma Observation Mode | Axial (vertical torch) |
| Operating Age | 3–4 years |
| Warranty | 6 months |
| Compliance | Fully refurbished and performance-verified per ISO/IEC 17025-aligned protocols |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Instrument Type | GC-MS |
| Model | ISQ QD |
| Mass Range | 1.2–1100 u |
| Ionization Modes | EI, PCI, NCI, PPINICI |
| Acquisition Speed | High-speed full-scan & SIM alternation |
| Source Design | ExtractaBrite™ with Full Source Removal™ |
| Vacuum Interlock | Yes |
| Software | QuanLab Forms, EnviroLab Forms, ToxLab Forms |
| Warranty | 6 months |
| Operational Age | 3–4 years |
| Configuration | Includes TRACE 1300 GC, workstation PC, vacuum pump |