Vacuum Gauge
Filter
Showing 31–60 of 63 results
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | TPR 270 |
| Measurement Range | 1 × 10⁻⁴ to 1000 hPa |
| Accuracy | ±10 % |
| Operating Temperature | up to 80 °C |
| Maximum Pressure Resistance | 400 kPa |
| Weight | 135 g |
| Flange Options | DN 16 ISO-KF, DN 16 CF-F |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | ActiveLine |
| Pressure Range | 10⁻¹¹ to 55,000 mbar |
| Output Signal | 0–10 V analog with integrated error diagnostics |
| Interface | Integrated measurement interface |
| Mounting Options | DN 16, DN 25/40, G 1/4″ |
| Operating Temperature | +5 °C to +60 °C (varies by sensor type) |
| Sensor Types | APR (Pirani), CMR (Capacitance Manometer), TPR (Combined Pirani/Thermocouple), PKR/IKR (Cold Cathode Ionization), PBR/IMR (Hot Cathode Ionization) |
| Pressure Units | Selectable (mbar, Pa, Torr, psi, etc.) |
| Compliance | CE, RoHS, EMC Directive 2014/30/EU |
| Software Integration | Compatible with Pfeiffer Vacuum Control Suite and third-party SCADA/PLC systems |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | Calibration System Pro |
| Calibration Range | 1013 hPa to 10⁻³ hPa |
| Flange Configuration | PS A30 110 (4×DN 16 ISO-KF, 2×DN 25 ISO-KF, 1×DN 40 ISO-KF, 1×DN 40 CF) / PS A30 111 (5×DN 16 ISO-KF, 2×DN 25 ISO-KF, 2×DN 40 ISO-KF) |
| Nitrogen Pumping Speed | 67 L/s |
| Forevacuum Pump Speed (50 Hz) | 2.5 m³/h |
| Ultimate Pressure | < 1 × 10⁻⁷ hPa |
| Gas Flow Control Range | 5 × 10⁻⁶ to 1 × 10³ hPa·L/s |
| Operating Temperature | +5 °C to +40 °C (cooling-dependent) |
| Weight | 66 kg (standard configuration) |
| Dimensions (L×W×H) | 700 × 639 × 593 mm |
| Compliance | ISO 3567, DAkkS-DKD-R 6-2, EN ISO 12100, EN 60204-1, CE (2006/42/EC & 2014/30/EU) |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | Digiline |
| Sensor Types | CPT200 / PPT200 / RPT200 / HPT200 / MPT200 |
| Measurement Range | 5×10⁻¹⁰ to 2×10³ mbar (model-dependent) |
| Operating Temperature | +5 °C to +50 °C |
| Enclosure Rating | IP54 |
| Electrical Interface | DIN M12 connector, RS-485 serial communication (Pfeiffer protocol), no RS-232 |
| Display | Backlit graphical LCD |
| Output Options | Analog (0–10 V or 4–20 mA), dual relay switch points |
| Compliance | Designed for integration into industrial vacuum systems per DIN/ISO standards |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | IKR 251 |
| Vacuum Interface | DN 25 ISO-KF, DN 40 ISO-KF, DN 40 CF-F |
| Measurement Range | 2 × 10⁻⁹ to 0.01 hPa |
| Operating Temperature | 5–55 °C |
| Bakeout Temperature | 150 °C |
| Accuracy | ±30 % |
| Ultimate Pressure | 10,000 hPa (atmospheric withstand) |
| Weight | 700 g |
| Output Signal | 0–10 V analog |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | IKR 251 |
| Measurement Principle | Cold Cathode Ionization |
| Range | 2×10⁻⁹ – 10⁻² hPa |
| Vacuum Interface | DN 25 ISO-KF / DN 40 ISO-KF / DN 40 CF-F |
| Operating Temperature | 5–55 °C |
| Bakeout Temperature | 150 °C |
| Accuracy | ±30 % |
| Output Signal | 0–10 V analog |
| Weight | 700 g |
| Sealing | FPM (Viton®) elastomer |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | IKR 361 / IKR 362 |
| Measurement Principle | Inverted Magnetron |
| Pressure Range | 1 × 10⁻⁹ hPa |
| Vacuum Flanges | DN 25 ISO-KF, DN 40 ISO-KF, DN 40 CF-F |
| Construction | Metal Seals (No Elastomer), Dual-Chamber Design |
| Optional Variants | Corrosion-Resistant Version, Low-Field / High-Current Configurations |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | ModuLine Gauge |
| Interface Options | PROFIBUS |
| Sensor Types | Capacitance Manometer (TPR series), Cold Cathode Ionization Gauge (IKR series) |
| Operating Temperature Range | –40 °C to +80 °C |
| Weight | 0.14–0.65 kg |
| Vacuum Range | 10⁻¹¹ mbar to 10³ mbar (depending on sensor module) |
| Sealing | Metal-sealed variants available |
| Radiation & EMI Resistance | Yes |
| Application Domain | Particle accelerator beamlines, UHV/XHV research systems, industrial vacuum process monitoring |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | OmniControl |
| Measurement Principle | Vacuum Pressure Monitoring and Pump Control via RS-485 and Analog Interfaces |
| Enclosure Rating | IP20 |
| Operating Temperature | 0°C to +50°C |
| Power Supply Options | 100–240 V AC ±10%, 47–63 Hz |
| Power Consumption | 300 W (OmniControl 200) / 411 W (OmniControl 300) / 522 W (OmniControl 400) |
| Output Voltages | 24 V DC (200/300) or 48 V DC (400) |
| Max Output Current | 11.4 A (200) / 15 A (300) / 8.33 A (400) |
| Display | 3.5-inch capacitive touchscreen |
| Mounting Options | Rack-mountable, desktop, or portable configurations |
| Compliance | Designed for integration with Pfeiffer Vacuum RS-485–enabled pumps (HiPace, HiScroll, HiLobe, MVP) and digital vacuum gauges |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | PCR 280 |
| Measurement Principle | Capacitance manometry with integrated Pirani sensor |
| Range | 5 × 10⁻⁵ to 1500 hPa |
| Vacuum Port Options | DN 16 ISO-KF, DN 16 CF-F, or custom flange |
| Operating Voltage | 15–30 V DC |
| Output Signal | 1.2–8.68 V analog |
| Bakeout Temperature | 80 °C |
| Accuracy | ±50% (5 × 10⁻⁴–1 × 10⁻³ hPa), ±15% (1 × 10⁻³–100 hPa), ±5% (100–950 hPa), ±2.5% (950–1100 hPa) |
| Ultimate Pressure | 5000 hPa (overpressure limit) |
| Weight | 120 g |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | PKR 251 |
| Measurement Principle | Pirani + Cold Cathode |
| Range | 5×10⁻⁹ to 1000 hPa |
| Vacuum Interfaces | KF 25, CF 40, KF 40 |
| Accuracy | ±30% (1×10⁻⁸ to 100 hPa) |
| Repeatability | ±5% |
| Operating Temperature | 5–55 °C |
| Bakeout Temperature | up to 150 °C |
| Power Supply | 15.0–30.0 V DC |
| Max. Power Consumption | ~2 W |
| Output Signal | 0–10.5 V analog voltage |
| Weight | ~700 g |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | PKR 361 |
| Measurement Principle | Pirani + Cold Cathode |
| Range | 5×10⁻⁹ to 1000 hPa (calibrated for air or N₂) |
| Vacuum Port Options | KF 25, CF 40, KF 40 |
| Repeatability | ±1% of reading (1×10⁻⁸ to 100 hPa) |
| Bakeout Temperature | ≤150 °C |
| Anode Material | Molybdenum |
| Flange Material | 1.4435 stainless steel |
| Compliance | CE, RoHS, EN 61326-1 |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | PKR251 |
| Measurement Principle | Integrated Pirani and Cold Cathode Gauge |
| Range | 5×10⁻⁹ to 1000 hPa (air/N₂) |
| Vacuum Port | DN25 ISO-KF, DN40 ISO-KF, DN40 CF-F |
| Max. Absolute Pressure | 10,000 hPa (inert gases, <55 °C) |
| Accuracy | ±30% (1×10⁻⁸–100 hPa) |
| Repeatability | ±5% (1×10⁻⁸–100 hPa) |
| Output Signal | 0–10.5 V analog |
| Supply Voltage | 15.0–30.0 V DC |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | TPG 201 |
| Measurement Principle | Pirani (thermal conductivity) |
| Pressure Range | 1000 to 5 × 10⁻⁴ hPa |
| Vacuum Interface | KF 16 |
| Operating Temperature | 5 to 40 °C |
| Accuracy | ±30 % at 10–100 hPa |
| Display | Integrated LCD |
| Power Supply | Rechargeable battery or external stabilized DC supply |
| Weight | 0.195 kg |
| Housing Material | Corrosion-resistant stainless steel |
| Heating Option | Available for low-outgassing and UHV-compatible operation |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | TPR 280 |
| Measurement Principle | Pirani |
| Range | 5 × 10⁻⁴ to 1000 hPa |
| Vacuum Interface | KF 16 (DN 16 ISO-KF) |
| Output Signal | 2.2–8.5 V DC |
| Supply Voltage | 14–30 V DC |
| Filament Material | Tungsten |
| Housing Material | Stainless Steel |
| Electrical Feedthrough | Glass |
| Operating Temperature | 5–60 °C |
| Bakeout Temperature | 80 °C (250 °C optional) |
| Accuracy | ±15% of reading (10⁻³–100 hPa) |
| Repeatability | ±2% of reading (10⁻³–100 hPa) |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | TPR 280 / TPR 281 |
| Measurement Range | 1.0 × 10³ hPa to 5.0 × 10⁻⁴ hPa |
| Operating Temperature | 80 °C (standard) / 250 °C (high-temp version) |
| Accuracy | ±15 % of reading |
| Burst Pressure | 1000 kPa |
| Weight | 80 g (TPR 280, standard) / 130 g (TPR 280, high-temp) / 80 g (TPR 281, corrosion-resistant) |
| Flange Options | DN 16 ISO-KF, DN 16 CF, 1/8" NPT, 8 VCR |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | TPR280 |
| Measurement Principle | Pirani thermal conductivity gauge |
| Range | 5 × 10⁻⁴ – 1000 hPa |
| Vacuum Port Options | DN16 ISO-KF, DN16 CF-R, 1/8" NPT, 8 VCR |
| Operating Temperature | 80 °C or 250 °C (depending on version) |
| Accuracy | ±15 % of reading |
| Maximum Pressure Resistance | 1000 kPa |
| Output Signal | 0–10 V analog |
| Weight | 80 g (80 °C version, DN16 ISO-KF) / 130 g (250 °C version, DN16 ISO-KF) |
| Brand | PH-Instruments |
|---|---|
| Origin | Germany |
| Model | DosiTorr SRG |
| Measurement Principle | Gas molecule adsorption/desorption-induced rotor deceleration, quantified via rotational decay rate |
| Pressure Range | 10 mbar to 5×10⁻⁷ mbar |
| Vacuum Interface | Designed for direct replacement of ionization gauges with plug-and-play electrical compatibility |
| Brand | ph-instruments |
|---|---|
| Origin | Germany |
| Model | ION Check |
| Measurement Principle | Spinning Rotor Gauge (SRG) |
| Range | 5 × 10⁻⁷ mbar to 1 × 10⁻² mbar (up to 1 mbar max) |
| Vacuum Interface | KF25 (adapters available for other standards) |
| Accuracy | ±1% of reading from 0.1 mbar to 1 × 10⁻⁶ mbar |
| Long-term Stability | <1% per year |
| Calibration Channels | Dual parallel |
| Pumping System | Oil-free turbomolecular pump + diaphragm backing pump |
| Data Interfaces | USB-C, LAN, RS-485, optional Bluetooth |
| Control Interface | 10-inch touchscreen, Windows 10, dedicated ION Check software |
| Power Supply | 230 VAC, 50 Hz, <2 A |
| Operating Temperature | 10–40 °C |
| Dimensions | 610 × 610 × 1200 mm |
| Weight | 90.8 kg |
| Brand | ph-instruments |
|---|---|
| Origin | Germany |
| Model | VIM-2 Portable Spinning Rotor Gauge |
| Measurement Principle | Momentum exchange due to gas molecule adsorption/desorption |
| Range | 10 mbar to 5×10⁻⁷ mbar |
| Vacuum Interface | USB Type-C / Bluetooth / High-density 15-pin D-sub |
| Accuracy | ±10% (10 mbar – 0.1 mbar), ±1% (0.1 mbar – 1×10⁻⁶ mbar) |
| Long-term Drift | <1% per year |
| Sensor Material | Stainless steel 1.4404 / 1.4034 |
| Operating Temperature (Electronics) | 10–40 °C |
| Sensor Max Temp (Metal Seal) | 450 °C |
| Power Supply | 18–28 VDC, Li-ion battery (>2 h operation) |
| Data Storage | 1023 internal records |
| Output | 0–10 VDC (configurable) |
| Weight | Host 1650 g, Measuring Head 750 g, Adapter 510 g |
| Brand | ROCKER |
|---|---|
| Origin | Taiwan |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (China) |
| Model | Pilot100 |
| Price Range | USD 1,400–2,800 |
| Measurement Principle | Digital Vacuum Gauge (Capacitance Manometer-Based) |
| Pressure Range | 0–1100 mbar (absolute) |
| Vacuum Port | ID 8 mm |
| Input Power | DC 24 V, 1 A |
| Resolution | 1 digit |
| Pressure Units | mbar, hPa, torr |
| Display | 7" capacitive touch screen |
| Accuracy | ±2 mbar (at stabilized ambient temperature, post-calibration) |
| Adjustable Setpoint Range | 0–1013 mbar (abs) / 0–760 mmHg |
| Housing Material | Flame-retardant engineering plastic (UL94 V-0) |
| Bleed Valve | Integrated solenoid-controlled air inlet valve |
| Self-Cleaning Function | Yes (automated vent/bleed cycle to prevent condensate accumulation) |
| Power Consumption | 15 W |
| Compatible Tubing ID | 8–10 mm |
| Safety Features | Overpressure protection, real-time error logging, audible/visual fault alerts |
| Dimensions (L×W×H) | 210 × 196 × 184 mm |
| Weight | 2.2 kg |
| Certifications | CE, RoHS, IP40 |
| Boiling Point Detection | Yes (dynamic vapor pressure tracking via pressure slope analysis) |
| Brand | SCChengyi |
|---|---|
| Origin | Sichuan, China |
| Model | ZDZ-4JA |
| Measurement Principle | Thermal Conductivity (Pirani) |
| Pressure Range | 1.0 × 10⁵ Pa to 1.0 × 10⁻¹ Pa |
| Vacuum Port | KF16 |
| Display | 4.3-inch TFT Touchscreen |
| Sensor Channels | 4 independent Pirani sensor inputs |
| Sensor Type | CY-1Z resistive gauge (included, 4 pcs) |
| Cable Length | 3 m (standard) |
| Dimensions (H×W×D) | 110 × 103 × 230 mm |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Weight | ~3 kg |
| Accuracy | ±20% of reading (typical, within specified range) |
| Brand | VACUUBRAND® |
|---|---|
| Origin | Germany |
| Model | CVC 3000 detect |
| Configuration | Desktop or Wall-Mountable |
| Sensor Type | Integrated Ceramic Capacitance Manometer |
| Control Principle | Two-Point Pressure Regulation with Vapor Pressure Detection (detect™) |
| Valve Type | Chemically Resistant Solenoid Vacuum Valve with Built-in Check Valve |
| Interface | Standard Laboratory Hose Fittings (e.g., DN 10, ISO-KF 10) |
| Functionality | Programmable Setpoint Control, Auto-Detection of Solvent Boiling Point via Dynamic Pressure Profile Analysis |
| Compliance | Designed for GLP/GMP-Compliant Laboratories |
| Software Integration | Optional PC Connectivity via RS232/USB (CVC Control Software v4.x) |
| Brand | VACUUBRAND® |
|---|---|
| Origin | Germany |
| Model | CVC 3000 Rough Vacuum Kit |
| Control Range | 1080–1 mbar |
| Control Method | Two-Point (On/Off) |
| Includes | CVC 3000 Controller, VV-B 6C Solenoid Valve, Plastic T-Fitting |
| Ordering Code | 683169 |
| Brand | VACUUBRAND® |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CVC 3000 |
| Pricing | Upon Request |
| Vacuum Sensor | Integrated ceramic capacitive sensor |
| Control Range | 1080 mbar to 0.1 mbar |
| Measurement Uncertainty | ±1 mbar (hPa/torr) under calibrated, isothermal conditions |
| Vacuum Interface | 10/8 mm PTFE fitting, DN 6/10 mm hose nozzle (KF DN 16 flange optional) |
| Vent Valve Interface | Integrated, DN 4–5 hose nozzle |
| Dimensions (L×W×H) | 144 × 124 × 115 mm |
| Weight | 0.44 kg |
| Ordering Code | 683160 |
| Brand | VACUUBRAND® |
|---|---|
| Origin | Germany |
| Model | DCP 3000 + VSK 3000 |
| Measurement Range | 0.1 mbar to 1080 mbar |
| Sensor Type | Alumina ceramic diaphragm, capacitive absolute pressure |
| Accuracy | ±1 mbar (hPa/torr) at constant temperature |
| Interface | KF DN 16 flange, PTFE 10/8 mm, soft hose nozzles DN 6/10 mm |
| Dimensions | 144 × 124 × 114 mm |
| Weight | 0.44 kg |
| Max Cable Length | 2 m (sensor), up to 30 m (via VACUU·BUS®) |
| Data Logging Capacity | 32,000 values |
| Bus Protocol | VACUU·BUS® digital bus |
| Sensor Compatibility | up to 4 × VSK 3000 (0.1–1080 mbar) + 4 × VSP 3000 (10⁻³–1080 mbar) |
| Relative Pressure Option | Yes (with VSK 3000 as reference) |
| Brand | VACUUBRAND® |
|---|---|
| Origin | Germany |
| Model | DCP 3000 + VSP 3000 |
| Measurement Principle | Thermal Conductivity (Pirani) |
| Measurement Range | 1×10³ mbar to 1×10⁻³ mbar |
| Accuracy | ±15% of reading (0.01–10 mbar) |
| Interface | KF DN 16 flange & DN 6/10 mm hose nipple |
| Dimensions (L×W×H) | 144 × 124 × 114 mm |
| Weight | 0.44 kg |
| Sensor Cable Length | 2 m |
| Bus Protocol | VACUU·BUS® digital bus |
| Max Connected Sensors | 8 (4×VSK 3000 + 4×VSP 3000) |
| Data Logging Capacity | 32,000 values |
| Housing Material | Chemically resistant PBT/PUR plastics & alumina ceramic |
| IP Rating | Splash-resistant (IEC 60529 IPX4 equivalent) |
| Brand | VACUUBRAND® |
|---|---|
| Origin | Germany |
| Model | DVR 2pro |
| Measurement Principle | Capacitive sensing via alumina ceramic diaphragm deflection under pressure differential |
| Range | 1–1060 mbar |
| Vacuum Interface | KF DN 16 flange and DN 6/10 mm hose nipple |
| Power Supply | 9 V Lithium battery (Ultralife U9VL, 1.2 Ah) |
| Display | Dual analog bar graph + digital numeric readout |
| Pressure Units | Selectable (mbar, hPa, Torr) |
| Accuracy | ±1 mbar / hPa / Torr (calibrated, isothermal conditions) |
| Sensor Material | Al₂O₃ ceramic membrane |
| EMC Performance | High immunity to electromagnetic interference (IEC 61326-1 compliant) |
| Dimensions (L×W×H) | ≈115 × 115 × 66 mm |
| Weight | ≈0.375 kg |
| Order No. | 20682906 |
| Brand | VACUUBRAND® |
|---|---|
| Origin | Germany |
| Model | DVR 3pro |
| Measurement Principle | Alumina ceramic diaphragm, capacitive, gas-independent |
| Range | 1 – 1060 mbar |
| Vacuum Port Options | KF DN 16, PTFE 10/8 mm, or Bayonet DN 6/10 mm |
| ATEX Certification | II 2G Ex ib IIC T4 Gb |
| Power Supply | 9 V alkaline battery (non-rechargeable) |
| Typical Battery Life | 4,000 h (operational), 30,000 h (standby) |
| Housing Material | Chemically resistant rigid plastic |
| IP Rating | IP40 |
| Operating Temperature | 10–40 °C |
| Storage Temperature | −10–60 °C |
| Auto-Off | User-selectable (1–600 min or continuous) |
| Measurement Cycle | Auto, 3 s, 1 s, or 0.33 s |
| Accuracy | ±1 mbar/hPa/torr (calibrated, isothermal) |
| Temperature Coefficient | < 0.15 mbar/hPa/K |
| Max. Steam Temp. | 40 °C (continuous), 80 °C (short-term) |
| Brand | VACUUBRAND® |
|---|---|
| Origin | Germany |
| Model | VACUU·VIEW® extended |
| Measurement Range | 1000 mbar to 1 × 10⁻³ mbar |
| Sensor Technology | Integrated ceramic diaphragm (capacitance manometer) + ceramic-encapsulated Pirani sensor |
| Chemical Resistance | Full compatibility with aggressive vapors and corrosive process gases |
| Display | Backlit LCD, menu-driven interface |
| Output | Analog (0–10 V) and digital (RS485/Modbus RTU) |
| Enclosure Rating | IP65 |
| Operating Temperature | 0–50 °C |
| Accuracy | ±2% of reading (full scale) in specified range |
| Long-term Stability | <0.5% drift/year |