Water Toxicity Analyzer
Filter
Showing 31–51 of 51 results
| Brand | microLAN |
|---|---|
| Origin | Netherlands |
| Model | TOX mini |
| Instrument Type | Portable |
| Biological Indicator | Aliivibrio fischeri (formerly Vibrio fischeri) |
| Operating Temperature | 15–30 °C |
| Reagent Storage & Use Temperature | 15–30 °C |
| Detection Principle | Bioluminescence Inhibition Assay |
| Compliance | EN ISO 11348-3 |
| Detector | Ultrafast Single-Photon Counting Photomultiplier Tube (PMT) |
| Wavelength Range | 380–630 nm |
| Data Storage Capacity | 2000 measurements |
| Power Supply | Rechargeable 3×Ni-Cd battery or external AC adapter (230 V/50 Hz or 115 V/60 Hz) |
| Dimensions (H×W×D) | 170×150×280 mm |
| Weight | 2.0 kg (with battery) |
| Sample Vessel | Standard 15 mm diameter × 47–75 mm height test tubes |
| Humidity Range | 10–90 % RH (non-condensing) |
| Onboard Templates | 6 preconfigured toxicity test protocols |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TOXmini |
| Instrument Type | Portable |
| Biological Indicator | Aliivibrio fischeri (formerly Vibrio fischeri) |
| Operating Temperature Range | +15 °C to +30 °C |
| Reagent Storage & Handling Temperature | +2 °C to +8 °C |
| Repeatability | ≤15% RSD (Relative Standard Deviation) at 50% inhibition level |
| Batch Capacity | 1–12 samples per run |
| Typical Measurement Time | 15–30 min per sample (ISO 11348-3 compliant) |
| Brand | Microwise |
|---|---|
| Origin | Denmark |
| Model | BallastWISE |
| Portability | Portable |
| Biological Target | Algal and zooplanktonic organisms |
| Operating Temperature | 0–40 °C |
| Reagent Storage Temperature | 0–40 °C |
| Repeatability | ±1% |
| Sample Throughput | Per batch |
| Analysis Time | 5 s |
| Detection Principle | Dual-mode fluorescence imaging + motility-based viability assessment |
| Size Classes Quantified | 10–50 µm and >50 µm |
| Brand | MN |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BioFix Lumi-10 |
| Instrument Type | Portable |
| Biological Agent | Bioluminescent Bacteria (Aliivibrio fischeri) |
| Operating Temperature Range | 0°C to 40°C |
| Reagent Storage & Usage Temperature | 0°C to 40°C |
| Coefficient of Variation (CV) | <10% |
| Photon Detection Rate | 5,000 photons per 0.1 second |
| Default Measurement Duration | 10 seconds (adjustable from 0.5 to 20 seconds) |
| Detector | Fast Single-Photon-Counting Photomultiplier Tube (PMT) |
| Spectral Sensitivity Range | 380–630 nm |
| Display | LED monochrome, 128 × 64 pixels |
| Data Storage Capacity | 2,000 measurement records |
| Relative Humidity Tolerance | 10–90% RH (non-condensing) |
| Recommended Operational Ambient Temperature | 15–30°C |
| Power Supply | 3× rechargeable Ni-Cd batteries or AC adapter (230 V/50 Hz or 115 V/60 Hz) |
| Dimensions (H×W×D) | 170 × 150 × 280 mm |
| Weight | 2.0 kg (including batteries) |
| Compliance | EU Low-Voltage Directive 73/23/EEC, EMC Directive 89/336/EEC (as amended by 92/31/EEC) |
| Brand | Modern Water |
|---|---|
| Origin | United Kingdom |
| Model | Microtox® CTM |
| Instrument Type | Online Continuous Monitoring System |
| Biological Sensor | Aliivibrio fischeri (formerly Vibrio fischeri) |
| Operating Temperature | 5–30 °C |
| Photonic Detection Range | 1–120,000,000 photon counts per assay |
| Assay Duration | 5 minutes |
| Sample Flow Rate | 100–200 mL/min |
| Power Supply | 100–240 V AC, 50–60 Hz, 480 W |
| Display | 180 mm color touchscreen |
| Data Interfaces | Ethernet, USB, 4–20 mA output, relay alarm, optional GPRS/Wi-Fi |
| Certifications | CE, RoHS, WEEE |
| Enclosure Material | Anodized aluminum |
| Dimensions (Main Unit) | 1250 × 750 × 365 mm (H×W×D) |
| Weight | ~70 kg |
| Maintenance Interval | Monthly (~2 hours) |
| Reagent Format | Lyophilized, vacuum-sealed vials |
| Brand | Modern Water |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Microtox® FX Plus |
| Instrument Type | Portable |
| Biological Agent | *Vibrio fischeri* (NRRL B-11177) |
| Operating Temperature | 0°C – 40°C |
| Reagent Storage/Use Temperature | 10°C – 28°C |
| Repeatability | <20% CV |
| Photon Counting Range | 1 – 120 million counts |
| Assay Duration | 1 – 30 minutes (user-definable) |
| Compliance | ISO 11348-3, CE, ISO 13485 |
| Brand | Modern Water |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Microtox® FX |
| Instrument Type | Portable |
| Biological Agent | Aliivibrio fischeri (bioluminescent bacteria) |
| Operating Temperature | 0°C – 40°C |
| Reagent Storage/Use Temperature | 10°C – 28°C |
| Repeatability | CV < 20% in Q-Tox and B-Tox modes |
| Photon Counting Range | 1 – ~60,000,000 counts |
| Assay Duration | 1–60 minutes |
| Brand | Modern Water |
|---|---|
| Origin | United Kingdom |
| Model | Microtox® LX |
| Instrument Type | Laboratory-Based |
| Test Organism | Aliivibrio fischeri (bioluminescent marine bacteria) |
| Operating Temperature | 15 °C – 30 °C |
| Reagent Storage & Handling Temperature | 10 °C – 28 °C |
| Temperature Control Precision | ±0.5 °C (sample & read chambers), ±1.0 °C (reagent chamber) |
| Detection Time | 5 min (acute assay) |
| Reproducibility (CV) | ≤15% |
| Dimensions | 45.7 cm × 25.4 cm × 43.2 cm |
| Weight | 9 kg |
| Display | 7" capacitive touchscreen |
| OS | Microsoft Windows 10 (pre-installed Microtox LX software) |
| Connectivity | USB 2.0 ×3, Wi-Fi 802.11ac, Bluetooth 4.2 |
| Certifications | CE, IEC 61010-1:2010, IEC 61010-2-010:2014, IEC 61326-1:2013, FCC Part 15 Subpart B |
| Power Input | 100–240 V AC, 50/60 Hz, 200 W |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | PTB-1500 |
| Instrument Type | Portable |
| Biological Indicator | *Aliivibrio fischeri* (lyophilized bioluminescent bacteria) |
| Dynamic Range | ≥10⁶ |
| Sample Tube Dimensions | Ø12 mm × 47–75 mm |
| Communication Interface | RS-232C |
| Measurement Duration | 0–99 s (1 s increments) |
| Data Storage Capacity | ≥2,000 test records |
| Operating Temperature | 15–40 °C |
| Display | Backlit LCD |
| Power Supply | AC 220 V ±10%, 50 Hz, 35 W |
| Rechargeable Battery | 3.7 V, 5000 mAh Li-ion |
| Operating Humidity | 10–90% RH (non-condensing) |
| Dimensions (L×W×H) | 320 × 170 × 180 mm |
| Weight | 2.0 kg (including battery) |
| Reagent Shelf Life | Up to 7 days post-reconstitution at 4 °C |
| Brand | Safe |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | AT-DX100 |
| Instrument Type | Portable |
| Biological Agent | *Aliivibrio fischeri* (formerly *Vibrio fischeri*) bioluminescent bacteria |
| Operating Temperature Range | 0–70 °C |
| Reagent Storage & Usage Temperature | 0–55 °C |
| Coefficient of Variation (CV) | ≤5% |
| Batch Capacity | 1–10 samples per run |
| Detection Time | ≤5 minutes |
| Brand | SDL |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | MODEL 9880 |
| Instrument Type | Online Analyzer |
| Biological Sensing Element | Electroactive Bacteria (Exoelectrogens) |
| Repeatability | ±30% |
| Detection Principle | Microbial Fuel Cell (MFC)-Based Current Response to Toxic/Nutrient Perturbations |
| Communication Interfaces | RS485, Modbus TCP, 4–20 mA Output, Optional 3G/4G LTE |
| Display Interface | Chinese-Language Touchscreen HMI |
| Compliance Framework | Designed for ISO 11348-3 and ASTM D5664 alignment in operational context |
| Brand | Senbe |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BM-6000 |
| Instrument Type | Online Analyzer |
| Biological Agent | *Aliivibrio fischeri* (formerly *Vibrio fischeri*) bioluminescent bacteria |
| Operating Temperature Range | 0–40 °C |
| Reagent Storage Temperature | 0–40 °C |
| Temperature Control Accuracy | ≤ ±1 °C |
| Batch Capacity | 10 samples per cycle |
| Measurement Time | 5 min (default assay duration) |
| Measurement Principle | Dual-optical-path bioluminescence inhibition assay |
| Compliance Standard | ISO 11348-3:2007 & GB/T 15441–1995 |
| Photometric Range | 0–200% relative light units (RLU) |
| Reproducibility (CV) | ≤10% |
| Pure Water Light Loss | ±3% |
| Sample Injection Precision | ≤2% (syringe-based volumetric delivery) |
| Data Storage | ≥2 years at 1-hour measurement interval |
| Communication Interface | RS-232 / RS-485 (Modbus RTU protocol) |
| Analog Output | 4–20 mA DC (≤300 Ω load) |
| Display | 12.1″ capacitive touchscreen LCD |
| Dimensions (W×D×H) | 560 × 430 × 1600 mm |
| Weight | ~20 kg |
| Brand | Shenchanghong |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TO3-260 |
| Instrument Type | Benchtop Laboratory Analyzer |
| Operating Temperature | 5–40 °C |
| Reagent Storage/Use Temperature | 5–40 °C |
| Repeatability | ≤3% |
| Sample Throughput | 1 sample per batch |
| Analysis Time | 20 min |
| Measurement Range | 0.01–2.5 mg/L O₃ |
| Accuracy (Abs. Error) | ≤±5% |
| Optical Drift | <0.002 A over 20 min |
| Dimensions (W×D×H) | 266 × 200 × 130 mm |
| Weight | 1 kg |
| Power Supply | AC 220 ± 22 V, 50 ± 0.5 Hz |
| Relative Humidity Limit | ≤85% RH (non-condensing) |
| Brand | Shengaohua |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | SH-9005 |
| Instrument Type | Portable |
| Biological Sensor | Bioluminescent Bacteria (Vibrio qinghaiensis, Photobacterium phosphoreum, or Vibrio fischeri) |
| Operating Temperature | 5–40 °C |
| Reagent Storage Temperature | –18 °C (1-year stability) |
| Repeatability | ≤10% RSD (at 2 mg/L ZnSO₄·7H₂O) |
| Detection Time | 5 minutes |
| Spectral Range | 300–1100 nm |
| Relative Light Units (RLU) Range | 0–65,535 |
| Inhibition Rate Range | –100% to +100% |
| Water Sample RSD | ≤±15% |
| Blank Inhibition Variability | ≤15% |
| Data Storage | 4 GB internal (expandable), >100,000 records |
| Communication Interfaces | USB, Bluetooth, Wi-Fi, 4G |
| Display | Capacitive touchscreen |
| IP Rating | IP65 |
| Battery Life | >24 hours continuous operation |
| Compliance | GB/T 15441–1995, ISO 11348-3 |
| ATP Mode Supported | Yes |
| Built-in Thermal Printer | Yes |
| Geotagging & Pollution Mapping | Yes |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | BIO3000 |
| Price Range | USD 14,000–42,500 |
| Instrument Type | Portable |
| Test Organism | Bioluminescent Bacteria |
| Operating Temperature | 0–40 °C |
| Reagent Storage Temperature | Room Temperature |
| Coefficient of Variation (Repeatability) | <5% |
| Sample Throughput | 1 sample per run |
| Assay Time | <25 min |
| Detection Range | 0–65,535 RLU |
| Inhibition Range | 0–100% (linear response 10–90%) |
| Spectral Sensitivity | 320–1100 nm |
| Power Supply | 220 V ±10%, 50 Hz |
| Weight | 450 g |
| Dimensions | 90 × 220 × 40 mm |
| IP Rating | IP65 |
| Battery Life | >12 h continuous operation |
| Data Storage | 4 GB internal (expandable), >100,000 records |
| Connectivity | USB, Bluetooth, Wi-Fi |
| Software Platform | Android-based embedded OS with guided workflow |
| Compatible Strains | *Vibrio qinghaiensis* sp.-Q67, *Photobacterium phosphoreum*, or *Vibrio fischeri* (ISO 11348-3 compliant) |
| Bacterial Lyophilized Stock Stability | 12 months at –18 °C |
| Environmental Operating Conditions | 5–40 °C, 10–90% RH (at 25 °C) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | AQ4BW1 |
| Instrument Type | Laboratory-Based |
| Biological Indicator | Bioluminescent Bacteria |
| Detection Principle | Bioluminescence Inhibition Assay |
| Compliance | ISO 11348-3:2022 |
| Measurement Range | 0–65535 RLU |
| Spectral Response | 320–1000 nm |
| Detection Time | As low as 5 min |
| Operating Temperature | 5–40 °C |
| Relative Humidity | 10–90% RH (at 25 °C) |
| Battery Life | ≥8 h continuous operation |
| Weight | ~258 g (including batteries) |
| Dimensions | 202 × 78 × 30 mm |
| Power Supply | 3 V DC (AA batteries) |
| Data Interface | USB |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | Thermo Scientific AQ4700 |
| Instrument Type | Online |
| Biological Indicator | Bioluminescent Bacteria |
| Detection Time | 5 min |
| Compliance | ISO 11348 |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Thermo Scientific AQ4700 |
| Instrument Category | Online |
| Biological Indicator | Bioluminescent Bacteria |
| Detection Time | 5 min |
| Brand | BBE / bbe Moldaenke |
|---|---|
| Origin | Germany |
| Manufacturer Type | Direct Manufacturer |
| Import Status | Imported |
| Model | Tox protectII |
| Instrument Type | Online Monitoring System |
| Test Organism | Live Fish (e.g., Danio rerio or Oncorhynchus mykiss) |
| Operating Temperature Range | 5–28 °C |
| Measurement Chamber Volume | 9 L (customizable) |
| Detection Principle | Real-time optical grating-based behavioral activity monitoring |
| Communication Interfaces | RS-485, Ethernet, Modbus TCP, optional GSM/SMS and analog alarm outputs |
| Alarm Modes | Local visual (tricolor LED), audible, remote SMS/fax/email via integrated gateway |
| Compliance | Designed for GLP-aligned operation |
| Brand | UXS |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | CDS100 |
| Instrument Type | Portable |
| Target Organisms | Pathogenic Microorganisms (including viruses, bacteria, protozoa) |
| Filtration Cut-off | <10 nm (0.01 µm) |
| Virus Retention Efficiency | >99.99% with Certified Cationic or Ultrafiltration Membranes |
| Flow Rate Range | 0.5–10 L/min (adjustable, volume-dependent) |
| Sample Volume Range | 3 mL – 2000 L (adaptive to turbidity and particulate load) |
| Fouling Resistance | High (engineered for high-sediment, high-organic-load natural waters) |
| Compliance | Designed for EPA Method 1615/1623.1 alignment |
| Brand | Water Doctor (DoctorWater) |
|---|---|
| Origin | Hunan, China |
| Model | Dr-W900 |
| Instrument Type | Portable |
| Biological Indicator | Bioluminescent Bacteria (Aliivibrio fischeri, Photobacterium phosphoreum, Vibrio qinghaiensis) |
| Operating Ambient Temperature | 10–40 °C |
| Reagent Storage Temperature | 2–8 °C (adjustable, ±1 °C accuracy) |
| Detection Temperature Control | 15–25 °C (adjustable, ±1 °C accuracy) |
| Incubation Capacity | 10 sample positions with independent temperature control |
| Detection Time | ≤15 minutes post-sample preparation |
| Compliance | GB/T 15441–1995, ISO 11348-3 |