| Brand | Astera |
|---|---|
| Origin | Guangdong, China |
| Model | XG5120 / XG5130 |
| X-ray Tube Voltage | 90 kV |
| X-ray Tube Current (Software-Limited) | 89 µA |
| Focal Spot Size | 5 µm |
| Cooling Method | Forced Air Cooling |
| Field of View | 2″ / 4″ |
| Spatial Resolution | 75 / 110 lp/cm |
| X-CCD Resolution | 1024 × 1024 pixels |
| Geometric Magnification | 12×–48× |
| Repeatability Accuracy | ±40 µm |
| Radiation Dose Rate | ≤1 µSv/hr (at any accessible surface) |
| System Dimensions | 2800 × 1550 × 1850 mm |
| Weight | ~2000 kg |
| Power Supply | AC 220 V, 10 A |
| Operating Environment | 22 ± 3 °C, 50 ± 10% RH |
| Computing Platform | 22″ widescreen LCD, Intel Core i3, 2 GB RAM, 500 GB HDD |
| Brand | Astroda |
|---|---|
| Origin | Guangdong, China |
| Model | XG5 |
| Price Range | USD 70,000 – 140,000 |
| Category | X-ray Radiographic Inspection System for Electronics Assembly |
| Detection Principle | Transmission X-ray Imaging (2.5D) |
| Motion Control | CNC-programmable XYZ-axis movement of X-ray source and image intensifier |
| Image Acquisition | Real-time digital radiography with software-based measurement and pass/fail classification |
| Compliance | Designed to support IPC-A-610, IPC-J-STD-001, and ISO 9001 quality audit workflows |
| Software | Proprietary automated inspection suite with measurement tools (linear distance, circle diameter, concentricity, point-to-center), navigation mapping, and DICOM-compatible image export |
| Brand | Astroda |
|---|---|
| Model | XG5100 |
| Application | In-line/Off-line Automated Radiographic Inspection of Polymer Pouch-Type Li-ion Cells and Sealed Battery Packs |
| X-ray Tube Voltage | Up to 110 kV |
| X-ray Tube Current | Up to 450 µA |
| Focal Spot Size | 5 µm |
| Detector Type | Line-Scan CCD/CMOS Array |
| Sensitive Area | 235 mm × 13 mm |
| Repeatability Accuracy | ±60 µm |
| Throughput | ≥25 parts per minute (ppm) |
| False Positive Rate | ≤2% |
| Miss Detection Rate | 0.0% |
| Overall Yield Compliance Rate | ≥99.5% |
| Radiation Leakage | ≤1 µSv/hr at any accessible surface |
| Cooling Method | Forced-Air Cooled X-ray Source |
| Safety Certification | Compliant with IEC 61000-6-4, IEC 61000-6-2, and GBZ 126–2011 (China National Standard for Radiation Protection in Industrial X-ray Equipment) |
| Brand | Astroda |
|---|---|
| Model | XG5200D |
| X-ray Tube Voltage | Up to 110 kV |
| X-ray Tube Current | Up to 450 µA |
| Focal Spot Size | 5 µm |
| Cooling Method | Forced Air Cooling |
| Image Intensifier Field of View | 4″ / 6″ |
| Spatial Resolution | 80 lp/cm |
| Camera Resolution | 752 × 480 pixels |
| Repeatability Accuracy | ±60 µm |
| Throughput | ≥6 parts per minute (at non-tab corner regions) |
| False Positive Rate | ≤2% |
| False Negative Rate | 0.0% |
| Pass Rate Consistency | ≥99.5% |
| Radiation Leakage | ≤1 µSv/hr (compliant with international radiation safety standards) |
| Brand | Astroda |
|---|---|
| Model | XG5300/XG5310 |
| X-ray Tube Voltage | 90 kV |
| X-ray Tube Current | 200 µA (software-limited to 89 µA) |
| Focal Spot Size | 5 µm |
| Cooling Method | Forced Air Cooling |
| Field of View | 2″ / 4″ |
| Spatial Resolution | 75 / 110 lp/cm |
| X-CCD Resolution | 1024 × 1024 pixels |
| Repeatability Accuracy | ±40 µm |
| Throughput | ≥60 PPM |
| False Positive Rate | ≤2% |
| False Negative Rate | 0.0% |
| Overall Yield Rate | ≥99.5% |
| Radiation Dose Rate | ≤1 µSv/hr (at any accessible surface) |
| Host Dimensions | 2500 × 1500 × 1700 mm |
| Power Supply | AC 380 V, 50 Hz |
| Operating Environment | 23 ±5 °C, ≤80% RH |
| Display | 22″ widescreen LCD |
| CPU | Intel Core i3 |
| RAM | 2 GB |
| Storage | 500 GB HDD |
| Brand | Astroda |
|---|---|
| Model | XG5600 |
| Origin | Guangdong, China |
| Detector Type | Flat-Panel Digital Radiography System |
| Max. Tube Voltage | 110 kV |
| Max. Tube Current | 450 µA |
| Focal Spot Size | 5 µm |
| Cooling Method | Forced Air |
| Detector Active Area | 54 mm × 48 mm |
| Spatial Resolution | 20.8 lp/mm |
| Pixel Matrix | 2000 × 2249 / 1000 × 1124 |
| Repeatability Accuracy | ±60 µm |
| Throughput | ≥50 ppm |
| False Positive Rate | ≤2% |
| False Negative Rate | 0.0% |
| Pass Rate Consistency | ≥99.5% |
| Radiation Leakage | ≤1 µSv/hr (measured at 5 cm from enclosure surface) |
| Compliance | IEC 61000-6-3, IEC 61000-6-4, GBZ 126-2011, ANSI N43.3 |
| Origin | Guangdong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | XG5010 |
| Price Range | USD 28,000 – 70,000 |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model Series | ChiRad |
| Price Range | USD 140,000 – 280,000 (FOB) |
| Focal Spot Size | 5.5 mm |
| Radiation Beam Angle | 40° |
| Maximum Penetration | 30 mm Fe (Iron Equivalent) |
| Brand | Nordson Dage |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Quadra 7 |
| Price | USD 1000 (Base Configuration Reference Only) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | S005-1 |
| Pricing | Available Upon Request |
| Max. Tube Voltage | 10–100 kV |
| Max. Tube Current | 10–100 µA |
| Max. Output Power | 10 W |
| Focal Spot Size | 0.05 mm |
| X-ray Window Material | Beryllium or Glass |
| Radiation Beam Angle | 20°, 28°, or 30° |
| Operation Mode | Continuous Duty |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | XIS1000 |
| Configuration | Mobile (Fixed-Base) |
| Max. Tube Voltage | 160 kV |
| Max. Tube Current | 1.25 mA |
| Effective Field of View | 450 × 400 × 560 mm (Sample Cavity) |
| External Dose Rate (30 cm) | ≤0.306 µSv/h |
| Compliance | GBZ 117–2022, GBZ/T 250–2014 |
| Brand | Tongda |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Models | XXG-1605, XXG-2005, XXG-2505, XXG-3005, XXG-3505 |
| Price Range | USD 1,400 – 7,000 (FOB) |
| X-ray Tube Type | Corrugated Ceramic Insulated Tube |
| Max. Output Voltage | 80–350 kV |
| Input Power | 1.5–3.5 kW |
| Focal Spot Size | 1.2×1.2 to 2.5×2.5 mm |
| Radiation Beam Angle | 40° ±5° |
| Steel Penetration (A3) | 19–60 mm |
| Generator Weight | 14.5–38 kg |
| Generator Dimensions (L×W×H) | 225×225×550 to 345×345×670 mm |
| Brand | Tongda |
|---|---|
| Model Series | XXGH-2005, XXGH-2505, XXGH-3005, XXGH-3205, XXGH-3505 |
| Max. Output Voltage | 100–350 kV |
| Input Power | 2.0–3.4 kW |
| Focal Spot Size | 1.0 × 2.0 mm to 1.0 × 2.5 mm |
| Radiation Coverage | 360° × 25° (conical & flat anode configurations) |
| Penetration in A3 Steel | 24–52 mm |
| Generator Weight | 27–55 kg |
| Generator Dimensions | 285×285×665 mm to 345×345×830 mm |
| Brand | Tongda |
|---|---|
| Model Series | XXH-1005, XXH-1605, XXH-2005, XXH-2505, XXH-3005, XXH-3205, XXH-3505 |
| Output Voltage Range | 50–350 kV |
| Input Power | 1.2–3.4 kW |
| Focal Spot Size | 0.8×0.8 mm to 1.0×5.0 mm |
| Radiation Coverage | 360° × 35° (conical target) / 360° × 25° (flat target) |
| Penetration in A3 Steel | 4–52 mm |
| Generator Weight | 11.1–55 kg |
| Generator Dimensions (L×W×H) | 190×190×520 mm to 345×345×830 mm |
| Brand | Tongda |
|---|---|
| Model Series | XXQ-1005, XXQ-1605, XXQ-2005, XXQ-2505, XXQ-3005, XXQ-3205, XXQ-3505 |
| X-ray Tube Voltage Range | 50–350 kV |
| Power Input | 1.2–3.4 kW |
| Focal Spot Size | 0.8×0.8 to 3.5×3.5 mm |
| Radiation Beam Angle | 40° or 40°+5° |
| Max Penetration in A3 Steel | 8–60 mm |
| Generator Weight | 11.1–47 kg |
| Generator Dimensions (L×W×H) | 190×190×520 to 345×345×830 mm |
| Origin | Liaoning, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | TSY Series |
| Pricing | Available Upon Request |
| X-ray Tube Voltage Range | 20–225 kV |
| Tube Current Range | 1–50 mA |
| High-Voltage Generator Weight | 210 kg |
| Cooling System | TZL-30 (integrated) or TZL-30F (split-type), temperature control range: 0–50 °C, accuracy: ±0.5 °C |
| Water Flow Rate | 1.6–3.0 L/min |
| Output Pressure | 2.5–4 kg/cm² |
| Control Interface | Color TFT touchscreen, Chinese-language UI |
| Safety Interlocks | Overcurrent, overvoltage, undervoltage, undercurrent, water flow loss, overheating, door interlock |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | XDLM-PCB210 |
| Pricing | Available Upon Request |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | X-RAY NDT |
| Price Range | USD 28,000 – 70,000 |
| Brand | Aisida |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | X-RAY Series |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | XRSIM (v3) |
| Pricing | Available Upon Request |
| Brand | Zhengye |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Classification | Domestic (China) |
| Model | Aisida XG5000 Series |
| Price Range | USD 28,000 – 70,000 |
| Brand | Zhengye |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | JuanraodianchiXRAY |
| Pricing | Available Upon Request |
| Brand | Zhengye |
|---|---|
| Model | XG5600 |
| X-ray Tube Voltage | Up to 130 kV |
| X-ray Tube Current | Up to 309 µA |
| Focal Spot Size | 5–7 µm |
| Imaging Method | Time-Delay Integration (TDI) Line-Scan Detector |
| Repeatability Accuracy | ±60 µm |
| Throughput | ≥120 ppm |
| False Positive Rate | ≤3% |
| Miss Detection Rate | 0.0% |
| Overall Yield Rate | ≥99.5% |
| Radiation Leakage | ≤1 µSv/hr (compliant with IEC 61000-6-4 & IEC 62471) |
| Power Supply | AC 220 V / 50 Hz |
| Operating Environment | 23 °C ±5 °C, Relative Humidity ≤10% RH |
| Brand | Zhengye |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | Automatic Loading & Unloading System for X-ray Target Drilling |
| Price Range | USD $68,000 – $136,000 (FOB Guangdong) |
| Configuration | Mobile or Fixed Mounting Options |
| Radiation Geometry | Circumferential (360°) |
| Radiation Beam Angle | 180° |
| Penetration Capability | High-Energy X-ray Compatible (Designed for ≥160 kV Industrial X-ray Sources) |
| Focus Size | Custom-Optimized (Configurable per X-ray Tube Integration) |
| Origin | Guangdong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | XG600 |
| Pricing | Available Upon Request |
| Brand | Zhengye |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | XK32A |
| Price Range | USD 70,000 – 140,000 |