Empowering Scientific Discovery

Yizun Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMetravib
OriginFrance
ModelDMA25/50
Instrument TypeDynamic Mechanical Analyzer (DMA/DMTA)
Temperature Range−150 °C to 500 °C (upgradable to 600 °C)
Temperature Accuracy±0.1 °C
Temperature Ramp Rate±0.1 to ±10 °C/min
Dynamic Force Range±25/±50 N (peak-to-peak: 50/100 N)
Displacement Range±3/±6 mm
Frequency Range1×10⁻⁵ to 200 Hz
Modulus Range10⁵ to 10¹¹ Pa
ComplianceASTM D4065, ISO 6721, ISO 11357-2, USP <1031>, FDA 21 CFR Part 11 (software-enabled)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMetravib
OriginFrance
ModelDMA+1000 / DMA+2000 + Xpander
Instrument TypeDynamic Mechanical Analyzer (DMA/DMTA)
Automation LevelFully Automated Robotic System
ComplianceDesigned for ISO 6721, ASTM D4065, ASTM D7028, ISO 11359-2, and USP <1031> compliant testing environments
Operating ModesTension, Compression, Dual Cantilever, Single Cantilever, Shear
Sample CapacityUp to 120 specimens per rack (configurable)
Footprint< 1.2 m²
Control InterfaceTouchscreen HMI + Ethernet-connected PC workstation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMetravib
OriginFrance
ModelDMA+2000
Instrument TypeDynamic Mechanical Analyzer (DMA/DMTA)
Temperature Range−150 °C to 500 °C
Temperature Accuracy±0.1 °C
Force Range−1000 N to +1000 N (peak-to-peak: 2000 N)
Displacement Range±6 mm (peak-to-peak: 12 mm)
Frequency Range1×10⁻⁵ Hz to 200 Hz (optional up to 1000 Hz)
Minimum Detectable Force0.01 N
Minimum Detectable Displacement0.1 µm
Modulus Measurement Range500 Pa to 3×10¹² Pa (6 decades)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMetravib
OriginFrance
ModelDMA+1000
Instrument TypeDynamic Mechanical Analyzer (DMA/DMTA)
Temperature Range−150 °C to 500 °C
Temperature Accuracy±0.1 °C
Force Range−500 N to +500 N (peak-to-peak: 1000 N)
Displacement Range±6 mm (peak-to-peak: 12 mm)
Frequency Range1×10⁻⁵ Hz to 200 Hz (optional up to 1000 Hz)
Minimum Detectable Force0.01 N
Minimum Detectable Displacement0.1 µm
Maximum Measurable Modulus3×10¹² Pa
Dynamic Modulus Range6 decades
Environmental Control OptionsO₂ concentration control (10 ppm–20% O₂), forced-air cooling (−70 °C), liquid nitrogen cooling (−150 °C)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMetravib
OriginFrance
ModelDMA+NG
Instrument TypeDynamic Mechanical Analyzer (DMA/DMTA) with Integrated Crack Growth Module
Temperature Range−150 °C to 500 °C
Temperature Accuracy±0.1 °C
Force Range0.1–500 N
Displacement Range0.1–6000 µm
Frequency Range10⁻⁵–200 Hz
Crack Measurement Channels2 or 4 simultaneous crack tip tracking positions
In-situ Initial Crack GenerationYes, inside climate-controlled chamber
Chamber Oxygen Control10 ppm–20% O₂ adjustable
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMetravib
OriginFrance
ModelDMA+ 300
Instrument TypeDynamic Mechanical Analyzer (DMA/DMTA)
Temperature Range–150 °C to +500 °C
Temperature Accuracy±0.1 °C
Force Range±150 N (peak-to-peak: 300 N)
Displacement Range±6 mm (peak-to-peak: 12 mm)
Frequency Range1×10⁻⁵ Hz to 200 Hz (up to 1000 Hz with optional high-frequency module)
Minimum Detectable Force0.01 N
Minimum Detectable Displacement0.05 µm
Stiffness Measurement Span>7 decades (250 Pa to 3×10¹² Pa)
Environmental Control OptionsO₂ concentration control (10 ppm–20% vol), cryogenic cooling (LN₂ or air-cooled to –150 °C)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMetravib
OriginFrance
ModelVHF104
Instrument TypeDynamic Mechanical Analyzer (DMA/DMTA)
Temperature Range−50 to 110 °C
Temperature Accuracy±0.5 °C
Temperature Stability±0.1 °C
Heating/Cooling Rate0.1–10 °C/min
Frequency Range100–10,000 Hz
Force Range±150 N
Displacement Range±10,000 µm
Strain Range10⁻⁶–30%
Deformation ModesTension, Compression, Annular Shear
Standard Masses5, 10, 20, 40, 80, 200 g
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0