Empowering Scientific Discovery

Thermo Scientific Forma 3110 Water-Jacketed CO₂ Incubator

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Origin USA
Manufacturer Type Authorized Distributor
Origin Category Imported
Model 3110 Water-Jacketed Series
Quotation Upon Request
Temperature Range Ambient +5°C to 55°C
Temp. Control Accuracy ±0.1°C
Temp. Uniformity ±0.2°C @ 37°C
CO₂/O₂ Control Accuracy Better than ±0.1%
CO₂ Range 0–20%
O₂ Range 1–20%
Resolution (CO₂/O₂) 0.1%
RH Range Ambient to 95% @ 37°C
RH Display Increment 1%
Water Jacket Volume 43.5 L
Internal Volume 184.1 L
Interior Material Perforated 304 Stainless Steel
Sterilization Temperature 140°C

Overview

The Thermo Scientific Forma 3110 Water-Jacketed CO₂ Incubator is an ISO 13485–certified, FDA-cleared platform engineered for stringent cell culture applications—including IVF, stem cell expansion, and primary tissue culture—where thermal stability, gas fidelity, and contamination control are non-negotiable. Its water-jacketed architecture provides passive thermal inertia, minimizing temperature fluctuations (<±0.2°C uniformity at 37°C) during ambient shifts or brief power interruptions. Unlike forced-air (air-jacketed) systems, the 3110’s 43.5 L water reservoir buffers thermal load changes, sustaining stable incubation conditions for up to 12 hours post-power-loss—a critical advantage in GMP-compliant labs and clinical embryology suites. Gas control employs dual-sensor architecture: a long-life infrared (IR) CO₂ sensor (2-year warranty) and optional electrochemical O₂ sensor, both calibrated traceably to NIST standards. The ENVIRO-SCAN microprocessor continuously monitors temperature, CO₂, O₂, and relative humidity (RH), executing real-time self-diagnostics and logging operational parameters for audit-ready GLP/GMP compliance.

Key Features

  • Water-jacketed construction with seamless, 100% radius-rounded interior corners (laser arc-welded 304 stainless steel) eliminates microbial harborage zones and supports validated cleaning protocols.
  • HEPA-filtered air supply (99.99% @ 0.3 µm) integrated into all intake and sampling ports; achieves Class 100 (ISO 5) air quality within 5 minutes of door closure.
  • Heated, double-paned inner glass doors (optional 8-door configuration) prevent condensation and accelerate thermal recovery (<60 sec to restore 37°C after opening).
  • Detachable, autoclavable inner door gaskets and perforated stainless steel shelving enable rapid decontamination without disassembly.
  • Modular fan assembly designed for tool-free removal—facilitating routine HEPA filter inspection, cleaning, or replacement per ISO 14644-3 cleanroom maintenance guidelines.
  • FDA 510(k)-cleared for IVF use (K993220); UL/CSA certified and CE-marked per IEC 61010-1 and IEC 61000-6-3 EMC standards.

Sample Compatibility & Compliance

The 3110 accommodates standard T-flasks (up to 175 cm²), multiwell plates (6–96-well), roller bottles, and Petri dishes across its 184.1 L internal chamber. Its RH control system (ambient–95% @ 37°C) maintains optimal moisture levels for sensitive suspension cultures and organoid models. All wetted surfaces comply with USP for extractables/leachables in biopharmaceutical manufacturing. The incubator meets ASTM E1917-22 for CO₂ incubator performance verification and supports 21 CFR Part 11–compliant data integrity when paired with Thermo Fisher’s ChronoLog™ software (audit trail, electronic signatures, role-based access).

Software & Data Management

ENVIRO-SCAN firmware supports configurable alarm thresholds (e.g., CO₂ deviation >±0.3%, temp drift >±0.5°C), email/SNMP notifications, and export of CSV-formatted logs via USB or Ethernet. Optional ChronoLog™ software enables automated report generation aligned with ISO/IEC 17025 accreditation requirements. All sensor calibrations are stored with timestamps and operator IDs; firmware updates retain full calibration history for regulatory review.

Applications

  • In vitro fertilization (IVF) and embryo culture under strict FDA-mandated environmental controls
  • Long-term mammalian cell line maintenance (e.g., CHO, HEK293) requiring low-oxygen (1–5% O₂) hypoxia modeling
  • Stem cell differentiation assays where RH stability prevents media evaporation-induced osmolarity shifts
  • Regulatory bioprocessing (USP , Ph. Eur. 2.6.27) requiring documented thermal/gas validation per IQ/OQ/PQ protocols
  • Academic core facilities supporting high-throughput screening with multi-user access logging

FAQ

What certifications does the Forma 3110 hold for clinical use?

It carries FDA 510(k) clearance (K993220) for IVF applications, UL/CSA safety certification, CE marking per EU MDR 2017/745, and ISO 13485:2016 quality system registration.
How is temperature uniformity validated across the chamber?

Per ASTM E1917-22, 9-point mapping (3×3 grid at mid-height) confirms ≤±0.2°C deviation at 37°C using NIST-traceable thermistors; certificate provided with each unit.
Can the incubator be integrated into a laboratory automation workflow?

Yes—Steri-Cult R variant offers RS-232/485 and Modbus TCP interfaces for robotic arm synchronization; the 3110 supports basic SCPI commands via serial port for external monitoring.
What is the service life expectancy of the IR CO₂ sensor?

Rated for 5 years under continuous operation; Thermo Scientific provides a 2-year limited warranty on IR sensors and 5-year coverage on CO₂ C/T (thermal conductivity) alternatives.
Is humidification performance affected by altitude or ambient humidity?

The RH control algorithm compensates for barometric pressure changes up to 3000 m elevation; ambient RH input is factored into vapor delivery rate to maintain setpoint accuracy within ±3% across 20–80% ambient RH.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0