Empowering Scientific Discovery

Thermo Fisher Heracell VIOS 250i CO₂ Incubator

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Thermo Fisher
Origin Germany
Manufacturer Thermo Fisher Scientific
Type Imported
Model 250i
Temperature Range & Accuracy 3 °C to 55 °C
Temperature Uniformity ±0.1 °C
Humidity Control (at 37 °C) >93% RH
Chamber Capacity 255 L
O₂ Control Range 1–21% (hypoxic) and 5–90% (hyperoxic)
Sterilization Cycle 180 °C dry-heat, 6-log bioburden reduction
Air Filtration ISO 5 certified HEPA, full-chamber air exchange every 60 s
Recovery Time (after door opening) ≤10 min for all parameters
Humidity Recovery Rate 5× faster than conventional water pan systems

Overview

The Thermo Fisher Heracell VIOS 250i CO₂ Incubator is an ISO 5-certified, high-performance cell culture incubator engineered for reproducible, contamination-controlled environments in demanding academic, clinical, and pharmaceutical laboratories. Designed with a solid copper inner chamber and direct-heating architecture, it eliminates cold spots and thermal lag associated with conventional jacketed systems. Its core environmental control relies on three independent, continuously monitored subsystems: precision thermoregulation via dual platinum resistance temperature detectors (Pt100), electrochemical or infrared-based CO₂ sensing with optional RH compensation, and active humidity management via a sealed, accessible water reservoir. The system operates under strict adherence to ISO 13485 design controls and supports GLP/GMP workflows through audit-trail-capable data logging and user-access-level configuration.

Key Features

  • Direct-Heating Copper Chamber: 255 L monolithic copper interior provides superior thermal conductivity, corrosion resistance, and inherent antimicrobial properties—critical for long-term sterility assurance and minimal surface biofilm formation.
  • THRIVE Active Airflow Technology: A low-turbulence, brushless DC fan circulates pre-humidified, HEPA-filtered air at controlled velocity, ensuring uniform distribution of temperature, CO₂, O₂, and humidity without shear stress on sensitive adherent or suspension cultures.
  • ISO 5 HEPA Filtration System: Integrated Class 5 (ISO 14644-1) HEPA filter recirculates and purifies the entire chamber volume every 60 seconds, achieving airborne particle counts ≤3,520/m³ (≥0.5 µm) within 5 minutes of startup—compliant with cleanroom-grade requirements for primary cell isolation and stem cell expansion.
  • Rapid Environmental Recovery: All critical parameters (temperature, CO₂, O₂, humidity) stabilize within ≤10 minutes following a standard 15-second door opening event—validated per ASTM E1246-22 test protocols for incubator performance verification.
  • High-Efficiency Humidity Management: Sealed, top-accessible humidification reservoir with anti-splash housing and condensation-free chamber walls enables stable >93% RH at 37 °C; humidity recovery rate is fivefold faster than passive water pan systems, minimizing desiccation risk during routine handling.
  • 180 °C Dry-Heat Decontamination Cycle: Fully automated, validated sterilization protocol delivers uniform 6-log reduction of bacterial endospores (e.g., Geobacillus stearothermophilus) across all internal surfaces—including sensors, shelves, and corners—without disassembly or autoclaving of components.

Sample Compatibility & Compliance

The Heracell VIOS 250i accommodates standard SBS-format multiwell plates (6–384-well), T-flasks (T-25 to T-225), Petri dishes, roller bottles, and custom bioreactor vessels up to 255 L total volume. Its O₂ control range (1–21% and 5–90%) supports physioxia modeling, tumor spheroid culture, and iPSC differentiation protocols requiring precise hypoxic or hyperoxic atmospheres. The system complies with IEC 61010-1 (safety), IEC 61326-1 (EMC), and meets essential requirements of the EU In Vitro Diagnostic Regulation (IVDR) Annex I for devices used in diagnostic sample conditioning. Optional FDA 21 CFR Part 11-compliant software packages enable electronic signatures, role-based access control, and immutable audit trails for regulated QC/QA environments.

Software & Data Management

Control and monitoring are executed via the iCAN™ interactive touchscreen interface, supporting seven languages (English, Spanish, German, French, Italian, Japanese, Mandarin) with context-sensitive help and real-time graphical performance curves. All sensor outputs—including dual Pt100 temperature readings, CO₂ concentration (TC or IR), O₂ partial pressure, and relative humidity—are logged at user-defined intervals (1–60 min) to internal flash memory (≥1 year of continuous data at 5-min resolution). Export options include CSV and PDF reports compatible with LIMS integration. Optional Thermo Fisher Connect™ cloud service enables remote status monitoring, predictive maintenance alerts, and centralized fleet management across multi-site facilities.

Applications

  • Mammalian cell line maintenance (HEK293, CHO, HeLa) under standardized 5% CO₂ / 37 °C conditions
  • Stem cell expansion and directed differentiation under dynamic O₂ modulation (e.g., 5% O₂ for mesenchymal stem cells)
  • Primary neuron and organoid culture requiring ultra-stable humidity and minimal airborne particulate exposure
  • Microbiological work with fastidious pathogens requiring CO₂-enriched, low-O₂ environments (e.g., Helicobacter pylori, Campylobacter jejuni)
  • Regulated bioprocess development where environmental traceability, calibration history, and change control documentation are mandated by USP , , or ISO/IEC 17025 standards

FAQ

What validation documentation is provided with the Heracell VIOS 250i?
Factory-installed IQ/OQ documentation compliant with ISO/IEC 17025 is included; PQ protocols and templates for site-specific qualification (e.g., mapping studies per ISO 14644-3) are available upon request.
Can the incubator be integrated into a building management system (BMS)?
Yes—via optional Modbus TCP or BACnet/IP communication modules for real-time parameter streaming and alarm forwarding to central facility monitoring platforms.
Is the copper chamber susceptible to oxidation or tarnishing over time?
No—the inner chamber features a passivated copper surface treated with a proprietary oxide-inhibiting coating, maintaining antimicrobial efficacy and visual integrity throughout its service life.
How often must the HEPA filter be replaced?
Under typical laboratory use (8 hrs/day, 5 days/week), the ISO 5 HEPA filter is rated for 12–18 months; replacement is tracked automatically via the iCAN™ interface and triggers a maintenance alert.
Does the 180 °C decontamination cycle affect sensor calibration?
No—all critical sensors (temperature, CO₂, O₂, RH) are designed to withstand repeated 180 °C exposures; factory calibration remains valid post-cycle, and no recalibration is required unless physical damage occurs.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0