| Brand | Teleopto |
|---|---|
| Origin | Japan |
| Model | LEDA-X |
| Configuration Options | LEDA4-X (4-zone), LEDA6 (6-zone), Dual-Color Variant |
| Driver Compatibility | LAD-4 (4-channel, BNC-triggered) or LAD-6 (6-channel, USB-controlled) |
| IP Rating | IP67 (fully waterproof) |
| Plate Compatibility | Standard 6-, 12-, 24-, 48-, and 96-well microplates |
| LED Positioning | Precisely aligned beneath each well center for uniform irradiance |
| Control Modes | Continuous or TTL-triggered pulsed illumination |
| Software Interface | LAD6 GUI (Windows-based, timestamped logging, protocol scheduling) |
| Brand | Teleopto |
|---|---|
| Origin | Japan |
| Model | TeleoptoELG |
| Weight (lightest variant) | 2 g |
| Battery Life | 12 h (2 g unit, no stimulation) / 25 h (3 g unit, no stimulation) |
| Channels | 2-channel differential bio-potential recording (EEG/EMG/LFP) |
| Data Storage | microSD card |
| Stimulation Control | Remote-triggered, dual-mode (pulsed & continuous) receiver |
| Optical Output | mW-level at fiber tip, wavelength-selectable via interchangeable LED cannula assemblies |
| LED Wavelength Flexibility | Dual-color (e.g., 470 nm / 590 nm) compatible with bi-stable opsins |
| Stimulation Configuration | Unilateral, bilateral, or sequential hemispheric stimulation via 1-channel or 2-channel receivers |
| Data Export Formats | TXT, EDF |
| Included Software | Dedicated viewer and export utilities |
| Brand | Panlab |
|---|---|
| Origin | Spain |
| Model | Thermal Place Preference |
| Temperature Range | -3°C to 65°C (ambient: 20–25°C) |
| Temperature Control Accuracy | ±0.5°C |
| Brand | RWD |
|---|---|
| Model | 69020 |
| Display | 4.3-inch color LCD touchscreen |
| Temperature setting range | 20–45 °C (±0.1 °C resolution) |
| Unit toggle | °C / °F |
| Power supply | 100–240 V AC, 50/60 Hz |
| Control unit dimensions | 205 × 148 × 80 mm |
| Control unit weight | 1.3 kg |
| Safety architecture | Separate circuit control for heating pad and rectal probe |
| Operating states displayed | IDLE, WARNING, STANDBY, WORKING |
| Included in base system | One 69023 heating pad (12.0 × 20.5 cm), one 69022 rectal probe (1.5 mm Ø, 30 mm insertion length, 150 cm cable) |
| Brand | Top Cloud-agri |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | TP-KCXW |
| Pricing | Upon Request |
| Brand | TOW-INT |
|---|---|
| Model | HOP-4 |
| Origin | Shanghai, China |
| Manufacturer | TOW-INT Technologies |
| Configuration | 4-channel, universal chamber set for mice and rats |
| Compliance | Designed for GLP-compliant respiratory phenotyping studies |
| Brand | TOW-INT |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Ox-100 |
| Instrument Type | Hypoxia Control System |
| Measured Parameters | Temperature, Relative Humidity, O₂ Concentration, CO₂ Concentration |
| O₂ Sensor | Electrochemical, 0–25% vol, resolution 0.01%, with temperature compensation |
| CO₂ Sensor | NDIR, 0–5000 ppm, accuracy ±30 ppm |
| Temperature Sensor | Platinum RTD (Pt100), high-precision digital |
| Humidity Control | Integrated humidity sensing + active dehumidification module |
| O₂ Control Accuracy | ±0.1% vol (steady-state) |
| Gas Mixing | Onboard proportional mixing with feedback-closed-loop regulation |
| Chamber Material | Optical-grade PMMA (acrylic), gas-tight, static-dissipative |
| Interface | 7-inch capacitive touchscreen HMI with intuitive workflow navigation |
| Chamber Configurations | Standard (1 rat cage / 2 mouse cages), Ox-100-D (2 rat / 4 mouse cages), Ox-100-F (4 rat / 8 mouse cages), Ox-100-MC-* (multi-channel independent control) |
| Brand | TOW-INT |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | ProOx-810 |
| Instrument Type | Hypobaric Hypoxia Chamber |
| Max Simulated Altitude | 12,000 m |
| Brand | TOW-INT |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | ProOx-810L |
| Pricing | Upon Request |
| Brand | TOW-INT |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | ProOx-811 |
| Instrument Type | Hypobaric-Hypoxic Exposure System |
| Oxygen Control Mode | Constant O₂ Concentration Control |
| O₂ Range | 0.1–99.9% vol |
| O₂ Control Accuracy | ±0.01% |
| Measured Parameters | Temperature, Relative Humidity, O₂ Concentration, CO₂ Concentration |
| Temperature Control Range | 20–45°C (standard) |
| Max Simulated Altitude | 12,000 m |
| Chamber Material | Thick Optical-Grade Acrylic |
| Display Interface | 10-inch Industrial Touchscreen |
| Data Export | CSV via USB drive |
| Safety Features | Dual-sensor + mechanical gauge monitoring, multi-parameter upper/lower limit alarms, pressure-gradient-reducing gas diffuser, multi-stage HEPA/activated carbon filtration, ergonomic cam-action door |
| Brand | TOW-INT |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | ProOx-820V |
| Instrument Category | Veterinary Rehabilitation Therapy System |
| Operating Pressure Range | 1.5–2.0 ATA |
| Internal Dimensions | 1000 mm (L) × Φ610 mm (D) |
| External Dimensions | 1500 × 1100 × 810 mm (L×H×W) |
| Net Weight | 250 kg |
| Oxygen Concentration Control Range | 21–95% (reaches ≥60% within 10 min) |
| Oxygen Sensor | High-Precision Zirconia-Based O₂ Sensor |
| CO₂ Monitoring Range | 0–5% |
| Temperature Display Range | 0–50 °C |
| Humidity Display Range | 0–100% RH |
| Oxygen Flow Rate | 20 L/min (compatible with medical-grade oxygen generators) |
| Touchscreen Interface | 10-inch HD capacitive touchscreen |
| Power Supply | 220 V / 50 Hz |
| Total Power Consumption | 1500 W |
| Acoustic Noise Level | ≤50 dB(A) |
| Safety Features | Dual-redundant pressure relief valves, manual emergency depressurization, mechanical door locking with torque-limited screw actuation, integrated hair/fiber filtration on gas inlets and exhaust ports |
| Compliance | Designed per ISO 13485 principles for veterinary medical device manufacturing |
| Brand | TOW-INT |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Yes |
| Country of Origin | China |
| Model | WBP |
| Pricing | Upon Request |
| Brand | TOW-INT |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Yes |
| Domestic Product | Yes |
| Model | WBP-4MR |
| Pricing | Upon Request |
| Brand | TOW-INT |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Yes |
| Country of Origin | China |
| Model | WBP-8MR |
| Pricing | Upon Request |
| Brand | TOW-INT |
|---|---|
| Model | WBP-P |
| Animal Application | Cynomolgus and Rhesus Macaques |
| Measurement Principle | Unrestrained Whole-Body Plethysmography (WBP) |
| Aerosol Delivery | Integrated Nebulization Module |
| Calibration | Automated In-Situ Pressure & Flow Calibration |
| Data Output | Exportable to .csv and .txt |
| Optional Integrations | ECG, Blood Pressure, Core Temperature, Heart Rate, Telemetry Compatibility |
| Compliance | Designed for GLP-compliant respiratory pharmacology and toxicology studies |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | TPR Monitor |
| Pricing | Upon Request |
| Brand | RWD |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | 68076 |
| Pricing | Available Upon Request |
| Brand | COULBOURN |
|---|---|
| Origin | USA |
| Model | Tru Scan |
| Configuration | Modular workstation-based system |
| Sensor Type | Planar capacitive sensor array |
| Stimulus Integration | Audio, visual, and electrical stimulation modules supported |
| Maximum Workstations | 10 |
| Software Platform | Tru Scan v5.x (Windows-based) |
| Data Compliance | Audit-trail enabled, exportable to CSV/Excel, compatible with GLP/GMP-aligned lab workflows |
| Regulatory Context | Designed for preclinical behavioral phenotyping in accordance with NIH, AAALAC, and OECD guidelines |
| Brand | Coulbourn |
|---|---|
| Origin | USA |
| Model | TSPAS |
| Regulatory Classification | Imported Instrument |
| Distribution Channel | Authorized Distributor |
| Pricing | Available Upon Request |
| Brand | TSE Systems |
|---|---|
| Origin | Germany |
| Model | Metabolic PhenoCages |
| Application | Automated Metabolic Phenotyping in Mice and Rats |
| Urine/Feces Separation | Dual-compartment funnel with cryo-compatible collection vessels |
| Quantification Method | High-precision load cells (±0.01 g resolution) under chilled collection containers |
| Integration | Fully compatible with PhenoMaster® and LabMaster® modular monitoring platforms |
| Optional Modules | CaloCage™ for indirect calorimetry, food/water intake sensors, XYZ photobeam activity frame |
| Cage Design | Modular, autoclavable components with rapid disassembly for decontamination |
| Sample Preservation | On-board cryogenic separation — urine and feces collected into individually chilled, sealed compartments |
| Brand | TSE Systems |
|---|---|
| Origin | Germany |
| Model | TSE MotoRater System |
| Application Scope | Quantitative kinematic gait analysis, locomotor behavior phenotyping, neuromuscular function assessment in rats and mice |
| Imaging Configuration | Multi-angle synchronized high-speed video capture (ventral + bilateral views) |
| Tracking Method | Color-based markerless or marker-assisted anatomical point tracking |
| Output Metrics | Joint angle kinetics, stride parameters, inter-limb coordination, trunk/tail kinematics, swim stroke dynamics |
| Compliance | Designed to support GLP-compliant preclinical studies |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Multi-Function Video Tracking & Behavioral Analysis Software |
| Pricing | Available Upon Request |
| Brand | TSE Systems |
|---|---|
| Origin | Germany |
| Model | PhenoMaster |
| Application | Modular, automated, long-term metabolic and behavioral phenotyping of rodents (mice and rats) |
| Cage Capacity | Up to 64 animals |
| Measurement Principle | Indirect calorimetry (O₂ consumption, CO₂ production, RER, energy expenditure) integrated with multi-sensor behavioral monitoring |
| Compliance | Designed for GLP-compliant studies |
| Software Platform | PhenoMaster Suite (v5.x or later), including experimental protocol scheduling, real-time visualization, raw data export (CSV, HDF5, MATLAB-compatible), and metadata-enriched database archiving |
| Brand | TSE Systems |
|---|---|
| Origin | Germany |
| Model | PhenoMaster_H |
| Configuration | Modular, Multi-Channel (up to 256 channels) |
| Gas Sensing | Zirconia O₂ sensor & NDIR CO₂ sensor |
| Flow Control | Independent high-flow controller per cage |
| Measurement Modes | Standard sequential mode & Real-time continuous mode (1 Hz per cage) |
| Data Output | Binary raw data with user-defined sampling frequency |
| Cage Airflow | Configurable PULL/PUSH mode with laminar wall-guided circulation |
| Activity Monitoring | XYZ optical 3D frame |
| Urine/Feces Collection | TSE-engineered hydrophobic umbrella-shaped internal lining |
| Compliance | Designed for GLP-compliant phenotyping studies |
| Software | PhenoMaster Control & Analysis Suite (FDA 21 CFR Part 11–ready audit trail, experimental protocol scheduling, time-synchronized multi-parameter export) |
| Brand | TSE Systems |
|---|---|
| Origin | Germany |
| Model | PhenoMaster_M |
| Application | Long-term, non-invasive metabolic phenotyping of small rodents (mice and rats) |
| Measurement Principle | Indirect calorimetry (O₂ consumption & CO₂ production via zirconia O₂ sensor and NDIR CO₂ sensor) combined with integrated behavioral and physiological monitoring |
| Channel Capacity | Up to 256 independently configurable cages |
| Gas Flow Control | Individual high-flow mass flow controllers per cage (PULL/PUSH selectable) |
| Data Acquisition | Raw binary time-series data (user-configurable sampling interval), full audit trail support |
| Compliance | Designed for GLP-compliant studies |
| Brand | TSE Systems |
|---|---|
| Origin | Germany |
| Model | PhenoMaster-R/M |
| Cage Capacity | Up to 64 rodents (rats or mice) |
| Measurement Principle | Indirect Calorimetry + Behavioral Sensor Fusion |
| Compliance | Designed for GLP-compliant metabolic phenotyping studies |
| Software Platform | PhenoMaster/LabMaster v5.x (FDA 21 CFR Part 11–ready audit trail, role-based access control, raw data export in CSV, HDF5, and MATLAB-compatible formats) |
| Brand | TSE Systems |
|---|---|
| Origin | Germany |
| Model | 5-Hole-Box System |
| Application | Operant Behavioral Testing in Mice and Rats |
| Stimulus Modality | Visual (LED), Auditory (White Noise, Sine Tones) |
| Reward Delivery | Pellet (14/20/45 mg) or Liquid via Solenoid-Actuated Dispensers |
| Detection Method | Infrared Beam Break |
| Programmability | Built-in Protocol Editor (Customizable Trial Logic, Stimulus Timing, Reinforcement Schedules) |
| Compliance | Designed for GLP-aligned behavioral phenotyping workflows |
| Brand | TSE Systems |
|---|---|
| Origin | Germany |
| Model | Active Avoidance / Passive Avoidance |
| Application Scope | Rodent (rat/mouse) behavioral conditioning |
| Stimulus Modalities | Electrical foot shock, pneumatic air puff, auditory tones (up to 20 kHz), visual light cues |
| Detection Method | Adjustable infrared beam break array |
| Software Platform | Windows-based TSE Behavioral Suite with real-time parameter logging and GLP-compliant audit trail |
| Compliance | Designed for ISO/IEC 17025-aligned laboratory environments |
| Max Concurrent Test Chambers | 4 |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AVGS-Series |
| Pricing | Available Upon Request |
| Brand | TSE Systems |
|---|---|
| Origin | Germany |
| Model | Aerosol Conditioning |
| Type | Aerosol Conditioning Unit for Inhalation Toxicology Studies |
| Construction Materials | Borosilicate Glass, Stainless Steel (316L), Chemically Resistant Polymers (e.g., PTFE, PFA) |
| Flow Rate Control | Precision Mass Flow Controllers (MFCs), Adjustable Air-to-Aerosol Ratio |
| Humidity Control | Saturated Steam or Bubble-Type Humidifier, ±2% RH accuracy |
| Temperature Control | Jacketed Glass Sections with Circulating Water Bath or Heated Stainless Steel Tubing (Range: 15–40 °C) |
| Electrostatic Neutralization | Polonium-210 or Soft X-ray Discharger (Compliant with ISO 15012-1) |
| Particle Pre-Separation | Impactor Stages & Cyclonic Separators (D50 adjustable from 0.5 µm to 10 µm) |
| Software Integration | DACO Inhalation Exposure Software (v5.2+), Supports ASTM E1777, OECD 412, and EPA OPPTS 870.3465 protocols |