| Brand | Ugo Basile |
|---|---|
| Origin | Italy |
| Model | 38500 |
| Force Resolution | 0.1 g |
| Maximum Applied Force | 1500 gf |
| Species-Specific Sensors | Rat & Mouse |
| Optional Accessory | Paw Pressure Sensor Module |
| Compliance | Designed for ASTM F2796-21–aligned behavioral nociception protocols |
| Software Interface | USB-connected digital readout with real-time force curve export (CSV/TXT) |
| Brand | Ugo Basile |
|---|---|
| Origin | Italy |
| Model | 47302 (Rat) / 47303 (Mouse) |
| Speed Range | 3–100 m/min (1 m/min increments) |
| Incline Range | −25° to +25° (5° steps) |
| Electric Stimulus | 0–2 mA (0.1 mA resolution) |
| Channel Configuration | 3 lanes (rat, 45 × 11 cm each) / 6 lanes (mouse, 45 × 5.5 cm each) |
| Frame Height | 15 cm (rat) / 7 cm (mouse) |
| Belt Material | Food-grade polymer with optimized traction |
| Data Output | USB export (TXT, Excel, PDF) |
| Control Interface | 4.3" capacitive touchscreen |
| Software | Integrated acquisition & analysis suite with audit-ready metadata tagging, hierarchical result tree, customizable layout, and GLP-compliant session annotation |
| Brand | Ugo Basile |
|---|---|
| Origin | Italy |
| Model | BIO-T2CT |
| Temperature Range | –3 °C to 65 °C |
| Temperature Accuracy | ±0.5 °C |
| Chamber Dimensions (L×W×H) | 33 cm × 16.5 cm × 30 cm |
| Overall Unit Dimensions (L×W×H) | 32 cm × 57 cm × 45.5 cm |
| Species Compatibility | 1 rat or 2 mice |
| Brand | Ugo Basile |
|---|---|
| Origin | Italy |
| Model | 31300 |
| Thermal Stimulation Range | Ambient Temperature to 70 °C |
| Mechanical Stimulus Levels | 5 Adjustable Force Steps |
| Data Acquisition Channels | Up to 16 Independent Cages |
| Behavioral Metrics | Feeding Duration (Min/Max/Mean), Feeding Attempts Count |
| Software Included | Yes |
| Brand | Ugo Basile |
|---|---|
| Origin | Italy |
| Model | 33 or 33T |
| Light Source Intensity Range | 0–250 (arbitrary units, ±1% accuracy) |
| Focal Spot Size | 4 × 6 mm |
| Reaction Time Resolution | 0.01 s |
| Preheating Temperature Range | 0–75 °C |
| Automatic Cut-off Timer | User-configurable |
| Data Output | RS-232 serial interface + thermal printer support |
| Compliance | Designed for GLP-compliant preclinical analgesia studies |
| Brand | Ugo Basile |
|---|---|
| Origin | Italy |
| Model | 35100 |
| Temperature Range | 2–66 °C |
| Temperature Resolution | 0.1 °C |
| Response Time | 0.1 s |
| Data Output | USB interface, included software & USB flash drive |
| Optional Accessories | Dual-plate module, thermal escape chamber kit (with custom glass enclosure) |
| Brand | Ugo Basile |
|---|---|
| Origin | Italy |
| Model | 37215 |
| Maximum Force | 750 g |
| Force Ramp Rate | 16 g/s (base), scalable to 32 g/s or 48 g/s with added weights |
| Scale Resolution | 5 g (base), scalable to 10 g or 15 g |
| Power Supply | 115/230 V, 50/60 Hz, ≤15 W |
| Dual-Tip Probe | Blunt and Conical |
| Motor Type | Low-Voltage Synchronous DC Motor |
| Brand | Ugo Basile |
|---|---|
| Origin | Italy |
| Model | 37360 |
| Infrared Intensity Range | 10–99 (arbitrary units) |
| Reaction Time Resolution | 0.1 s |
| Cut-off Time Range | 15–60 s |
| Power Supply | 85–264 VAC, 50–60 Hz |
| Operating Temperature | 15–30 °C |
| Acoustic Noise Level | < 70 dB |
| Interface | 9-pin DELTA connector + USB |
| Display | LCD screen |
| Data Export | USB flash drive or USB cable |
| Optional Accessories | Thermal printer (sold separately), infrared radiometer for calibration (sold separately) |
| Brand | Ugo Basile |
|---|---|
| Origin | Italy |
| Model | 37570 |
| Touchscreen Interface | 4.3" capacitive display |
| IR Intensity Range | 1–99 (unitless digital setting) |
| Latency Resolution | 0.1 s |
| Stimulus Duration Range | 5–30 s |
| Operating Temperature | 10–40 °C |
| Acoustic Noise Level | <54 dB(A) |
| Animal Compatibility | Mice and rats |
| Data Export | USB flash drive |
| Calibration | Optional traceable infrared radiometer |
| Safety Filter | Integrated visible-light blocking filter |
| Detection Method | Automated infrared-based paw withdrawal detection |
| Enclosure Capacity | Up to 6 rats or 12 mice |
| Trigger Options | Touch icon, front-panel button, or TTL input (5 V logic) |
| Origin | Italy |
|---|---|
| Supplier Type | Authorized Distributor |
| Import Status | Imported Instrument |
| Model | 37570 |
| Price Range | USD 6,800 – 13,600 |
| Stimulus Type | Adjustable Infrared Thermal Beam |
| Response Detection | Automated Foot Withdrawal Timing |
| Temporal Resolution | 0.1 s |
| Intensity Range | 10–99 (arbitrary units) |
| Chamber Configuration | Triple Independent Testing Chambers |
| Data Output | LED Display + Optional PC Interface + Printer Support |
| Calibration Option | Compatible with Ugo Basile Radiometer Model 37300 |
| Brand | Ugo Basile |
|---|---|
| Country of Origin | Italy |
| Model | 390/390G |
| Heating Range | 0–250 °C (±1% accuracy) |
| Focused Beam Size | 4 × 6 mm |
| Paw Withdrawal Latency Resolution | 0.01 s (manual stop) |
| Input Interface | Numeric keypad, push-button, and footswitch |
| Dimensions | 45.7 × 45.7 cm (18″ × 18″) |
| Data Output | Printer + RS-232 to PC |
| Brand | Ugo Basile |
|---|---|
| Origin | Italy |
| Model | 520 |
| Animal Compatibility | Mouse (520M), Rat (520R), Dual-Species (520MR) |
| Volume Resolution | 0.001 mL (mouse), 0.01 mL (rat) |
| Display | LCD with real-time volumetric readout |
| Actuation | Footswitch-triggered measurement |
| Power Options | 9 V alkaline battery or external DC adapter |
| Wetting Solution Required | No |
| Calibration | Zero-reset function between consecutive measurements |
| Intended Use | Preclinical inflammatory edema quantification in rodent hind paws |
| Brand | Ugo Basile |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | 53500 |
| Quotation | Upon Request |
| Output | Constant DC Current |
| Current Range | 10–99 mA |
| Timing Range | 1–99 s |
| Operating Temperature | 0–30 °C |
| Acoustic Noise Level | <45 dB(A) |
| Max. Load Impedance | 20 MΩ @ 10 µA / 2 kΩ @ 100 mA |
| Short-Circuit Protection | Active Electronic Monitoring |
| Visual Indicators | Yellow LED (Error), Red LED (Power Status) |
| Power Supply | 115 V or 230 V AC, 50/60 Hz, 20 W |
| Dimensions (W×D×H) | 25 × 15 × 11 cm |
| Net Weight | 1.5 kg |
| Gross Weight | ~2.8 kg |
| Packaging Dimensions | 49 × 29 × 24 cm |
| Brand | Ugo Basile |
|---|---|
| Country of Origin | Italy |
| Model | 37450/277 |
| Force Range | 0.008 g – 300 g (0.08 mN – 2.94 N) |
| Filament Count | 20 |
| Compliance | ASTM F2475-21, ISO 13485 (manufacturer), GLP-ready application protocol |
| Brand | Unisense |
|---|---|
| Origin | Denmark |
| Model | microrespiration |
| Detection Principle | Amperometric Microsensor-Based Closed-Circuit Respirometry |
| Measurement Range (O₂) | 0–500 µM |
| Current Resolution | 10⁻¹² A |
| Detection Limits | O₂: 0.3 µM |
| NO | 20–30 nM |
| Sample Volume Capacity | 0.5–8 mL (dual-port microrespiration vials) |
| Electrode Compatibility | O₂, H₂, H₂S, NO, N₂O, pH, Redox, Temperature, Flow, Diffusivity, NO₂⁻, NO₃⁻ |
| Signal Processing | Low-Noise Analog Amplification + 24-bit ADC Conversion |
| Compliance | GLP-Compatible Data Acquisition Architecture |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | V3395 |
| Pricing | Upon Request |
| Brand | RWD |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | S11001-08 |
| Price | USD 79 (approx.) |
| Brand | RWD |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model Numbers | S11014-12 (Straight/Tapered Tip), S11015-12 (Curved/Tapered Tip) |
| Length | 12.5 cm (S11014-12), 12 cm (S11015-12) |
| Blade Tip Geometry | Tapered/Tapered |
| Handle Type | Spring-Loaded Ergonomic Stainless Steel |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | VCU FPI / VCU eCCI / VCU CIC II |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | VCU |
| Pricing | Available Upon Request |
| Brand | Mindray |
|---|---|
| Model | Vetal 3 |
| Origin | Shanghai, China |
| Instrument Type | ECG-based Multi-parameter Monitor |
| Sample Compatibility | Small to medium companion animals (canine, feline, rabbits, ferrets) |
| Regulatory Status | CE-marked for veterinary use |
| Display | 7-inch high-brightness, anti-glare TFT LCD with touch-responsive interface |
| Power | Rechargeable Li-ion battery (≥4 hrs continuous operation) |
| Connectivity | USB port for data export |
| Alarm System | Three-tier visual/audible alarm hierarchy (High/Medium/Low), species- and weight-adjustable thresholds |
| Environmental Rating | IP21 (dust-protected, drip-resistant) |
| Design | Fanless architecture, pet-hair-resistant air intake, ergonomic handheld form factor |
| Brand | Mindray |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Vetgenies 8 |
| Instrument Type | Veterinary Real-Time qPCR Platform |
| Nucleic Acid Extraction | Optional On-Device Lysis (Extraction-Free Workflow Supported) |
| Detection Chemistry | Dual-Channel SYBR Green I and Probe-Based (FAM/HEX) Fluorescence Detection |
| Thermal Cycling Accuracy | ±0.25 °C |
| Ramp Rate | Up to 5.0 °C/s |
| Reaction Volume | 10–50 µL |
| Throughput | 8 Samples per Run |
| Optical System | Integrated LED Excitation & Photodiode Detection |
| Data Output | Ct Values, Amplification Curves, Melting Curves, Qualitative/Quantitative Reports |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | V3402 |
| Pricing | Available Upon Request |
| Brand | TSE Systems |
|---|---|
| Origin | Germany |
| Model | VideoMot2 |
| Camera Input | Single high-resolution monochrome or color camera (configurable) |
| ROI Support | Unlimited user-defined regions of interest (ROIs) |
| Animal Detection | Contrast-based segmentation with adaptive thresholding |
| Tracking Method | Three-point centroid tracking (nose, center, tail base) |
| 3D Capability | Compatible with optional beam-break frame for vertical posture detection (rearing analysis) |
| Behavioral Event Logging | External programmable event keyboard (10 customizable keys) |
| Data Output | ASCII text files (tab-delimited), bitmap trajectory exports, raw coordinate time-series (.csv) |
| Software Architecture | Windows-based client application with audit trail logging |
| Compliance | Designed to support GLP-compliant workflows |
| Remote Operation | Wired or wireless remote start/stop via dedicated control interface |
| Brand | TSE Systems |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | VisioTrainer by NewBehavior |
| Pricing | Upon Request |
| Origin | Czech Republic |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | VISIR |
| Price Range | USD 14,000 – 70,000 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Vogel Test |
| Pricing | Available Upon Request |
| Brand | TSE Systems |
|---|---|
| Origin | Germany |
| Model | Volume Meter |
| Measurement Range | Up to 9.99 mL |
| Sample Type | Rodent paw (rat & mouse), solid specimens |
| Output Interface | Direct Excel export via PC connection |
| Sensor Principle | High-precision liquid column displacement transduction |