Animal Experiment Instruments
Filter
Showing 121–150 of 890 results
| Brand | RWD |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | R33003-01 |
| Price | Upon Request |
| Brand | RWD |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Classification | Domestic (China) |
| Model | R33003-02 |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DigiGait™ |
| Pricing | Upon Request |
| Brand | DITECT |
|---|---|
| Origin | Japan |
| Model | DIPP-Motion V |
| Video Input Formats | AVI, WMV, MP4 (via conversion), MPEG-2, MOV |
| Image Formats | PNG, TIFF, GIF, JPEG, BMP (sequence) |
| Bit Depth | 8-bit monochrome / 24-bit color |
| Calibration Methods | 2-point, projection, grid (2D) |
| Tracking Algorithms | Normalized Cross-Correlation (NCC), grayscale binarization, HLS-color binarization, checkerboard marker detection, manual digitization, auto-marker extraction (grayscale, checkerboard, correlation grid, particle tracking) |
| Spatial Resolution | Sub-pixel (2D) |
| Maximum Trackable Points | Unlimited (software-limited) |
| Maximum Frame Count | Unlimited (storage-limited) |
| Output Formats | CSV, binary project (.dm5), WMV video overlay |
| Data Export | X/Y (2D), X/Y/Z (3D), velocity, acceleration, angular displacement, joint angles, roll/pitch/yaw (3D), ROI area, inter-marker distances |
| Preprocessing | Geometric transformation, arithmetic/frame operations, color space conversion, smoothing, noise reduction, filtering, channel separation, region-of-interest tiling, frame/pixel shifting |
| Postprocessing | Translation, interpolation, smoothing, virtual point generation |
| System Requirements | Windows 7/8/10, Intel Core i5 (multi-core), ≥4 GB RAM, ≥10 GB HDD free space, OpenGL 2.0-compatible GPU |
| Brand | DS |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DXL-10 |
| Instrument Type | Research-grade rat metabolic housing system |
| Sample Capacity | 10 independent cages |
| Temperature Range | Ambient (room temperature operation) |
| Functional Configuration | Urine-feces separation |
| Material | AISI 304 stainless steel |
| Overall Dimensions | 1350 × 350 × 1500 mm |
| Individual Cage Dimensions | 250 × 200 × 200 mm |
| Cage Layout | 2 rows × 5 columns = 10 positions |
| Standard Accessories per Cage | 1 stainless steel drinking bottle, 1 feed hopper, 1 cage body, 1 collection tray |
| Additional Components | 1 modular stainless steel support frame with 4 locking casters |
| Brand | DS |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Rat Metabolic Cage |
| Model | DXL-D |
| Dimensions (L×W×H) | 300 × 300 × 650 mm |
| Material | Medical-grade Polycarbonate (PC) |
| Urine/Feces Separation | Dual-channel conical funnel system with anti-evaporation urine collector and non-adhesive fecal collection tube |
| Assembly | 15 modular components, tool-free disassembly |
| Compliance | Designed for GLP-compliant preclinical studies in pharmacology, endocrinology, and nutrition research |
| Brand | DS |
|---|---|
| Origin | Beijing, China |
| Model | DXL-X |
| Animal Type | Laboratory mouse (Mus musculus) |
| Capacity | 1–5 mice per cage |
| Temperature Range | Ambient (optional 4 °C refrigerated urine/feces collection module available) |
| Material | Polycarbonate (PC) or Polyphenylsulfone (PSU) |
| Cage Dimensions | Ø170 mm × 220 mm (cage body) |
| Overall | 210 mm × 210 mm × 400 mm |
| Urine Collection Vessel | 15 mL |
| Water Bottle Capacity | 880 mL |
| Filtration Mesh Aperture | 0.1 mm |
| Urine/Fecal Separation | Dual-compartment gravity-driven separation system |
| Compliance | Designed for GLP-aligned preclinical metabolic studies |
| Brand | Panlab |
|---|---|
| Country of Origin | Spain |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | VivaMARS |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | Dust Generator |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | ECG Monitor |
| Pricing | Available Upon Request |
| Brand | EcoTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | HT-Respiro 24/96/240 Series |
| Pricing | Available Upon Request |
| Oxygen Measurement Range | 0–50% O₂ or 0–22.5 mg/L |
| Detection Limit | 0.15% O₂ (15 ppb DO) |
| Accuracy | ±1% at 20.9% O₂ |
| Resolution | ±0.4% at 20.9% O₂ or ±5 µmol at 283.1 µmol |
| Response Time | <30 s |
| Drift | <1% air saturation per week (10-min sampling interval) |
| Channel Capacity | Up to 240 parallel channels (10 × 24-channel readers) |
| Sensor Technology | Fluorescence-based optical oxygen sensing (REDFLASH for 96-well format) |
| Sample Chamber Material | Borosilicate glass (24-well) or sterile polystyrene (96-well) |
| Chamber Volume | 80–1700 µL (24-well) |
| Dimensions (per 24-channel reader) | 163 × 89 × 22 mm |
| Weight (per reader) | 380 g |
| Brand | EcoTech |
|---|---|
| Origin | Beijing, China |
| Model | Insect High-Throughput |
| Detection Technology | Fluorescence-based Optical Oxygen Sensing |
| Channel Capacity | 96 simultaneous channels |
| Measurement Principle | Non-invasive, real-time O₂ consumption via phase-modulation fluorometry |
| Sample Types | Drosophila melanogaster, insect eggs/pupae, nematodes, soil microarthropods, and other small invertebrates |
| Operating Environment | Compatible with incubators (0–50 °C) and orbital shakers |
| Oxygen Measurement Range | 0–100% O₂ (gas phase) or 0–20 mg/L (aqueous phase) |
| Accuracy | ±0.1% O₂ @ 1% O₂ or ±0.05 mg/L @ 0.44 mg/L |
| Resolution | 0.01% O₂ or 0.005 mg/L |
| Response Time (t₉₀) | <30 s |
| Sampling Frequency | Up to 20 Hz per active channel |
| Integrated Sensors | Temperature (0–50 °C, ±0.5 °C, 0.012 °C resolution), Pressure (300–1100 mbar, ±6 mbar, 0.11 mbar resolution) |
| Power Supply | 5 V DC via USB |
| Dimensions (O₂ Host Unit) | 162 × 102 × 32 mm |
| Weight | 670 g |
| Chamber Material | Sterilizable transparent polystyrene |
| Software Compliance | Audit-trail enabled, timestamped raw data export (CSV, HDF5), supports GLP-aligned experimental metadata tagging |
| Brand | EcoTech |
|---|---|
| Origin | Denmark |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LoliTrack |
| Pricing | Upon Request |
| Brand | EcoTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | EcoTech Multi-Channel |
| Pricing | Upon Request |
| Brand | EcoTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Assembly | China |
| Model | SSI-ET Modular |
| Instrument Type | Research-grade rodent (mouse/rat) metabolic phenotyping system |
| Channel Configurations | 4-, 8-, 16-, or scalable multi-channel (up to 24+) |
| Gas Analytes | CO₂ (0–5% / 0–15%, dual-range NDIR), O₂ (0–100%, paramagnetic), H₂O (RH 0.2–100%, dew point −40 to +40°C) |
| Flow Control | Precision mass flow controllers (5–2000 mL/min), thermal-mass flow meters (±2% accuracy) |
| Data Acquisition | 12-channel DAQ (8 × 16-bit analog, 4 × dedicated thermistor inputs, 100 Hz sampling) |
| Software | EcoMetab v5.x with real-time RQ, VO₂, VCO₂, EE calculation |
| Compliance | Designed for ISO/IEC 17025-aligned lab environments |
| Optional Modules | Implantable telemetry (E-mitter compatible), infrared thermography integration, activity monitoring (beam-break/PIR), environmental control (T/RH/O₂/CO₂ regulation), cage-integrated load cells & fat temperature sensors |
| Brand | EcoTech |
|---|---|
| Origin | Beijing, China |
| Model | Zebrafish High-Throughput |
| Detection Technology | Fluorescent Fiber-Optic Oxygen Sensing |
| Channel Capacity | 96 simultaneous channels |
| Oxygen Measurement Accuracy | ±0.1% O₂ @ 1% O₂ or ±0.05 mg/L @ 0.44 mg/L |
| Oxygen Resolution | 0.01% O₂ @ 1% O₂ or 0.005 mg/L @ 0.44 mg/L |
| Response Time | <30 s |
| Temperature Sensor Range | 0–50°C, Resolution: 0.012°C, Accuracy: ±0.5°C |
| Pressure Sensor Range | 300–1100 mbar, Resolution: 0.11 mbar, Accuracy: ±6 mbar |
| Max Sampling Frequency | 10–20 Hz per active channel |
| Power Supply | 5 VDC via USB |
| Dimensions (O₂ Host) | 162 × 102 × 32 mm |
| Weight (O₂ Host) | 670 g |
| Chamber Material | Sterilizable transparent polystyrene |
| In Situ Compatibility | Yes — designed for incubators and orbital shakers |
| Non-Invasive & Non-Destructive Operation | Yes |
| Origin | Shenzhen, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | EFC-82 |
| Pricing | Upon Request |
| Temperature Options | Ambient or Refrigerated (with optional EFR-82 module) |
| Sample Vessels | 96-well PCR plates or 0.5 mL microcentrifuge tubes |
| Flow Rate Range | 0.1–10 µL/min (collection interval: 5 s – 99 min) |
| Channel Capacity | 1, 2, or 4 independent microdialysis channels |
| Control Interface | Integrated front-panel programmable controller (standalone operation, no PC required) |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | EVF3 |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | Elevated Plus Maze |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | ETCO₂-ANIMAL |
| Price | Upon Request |
| Origin | Guangdong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | 68902 |
| Pricing | Upon Request |
| Origin | Shenzhen, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (PRC) |
| Model | BP-2010A |
| Pricing | Available Upon Request |
| Display | 4.3-inch color LCD |
| Measurement Principle | Infrared photoplethysmography (PPG) |
| Method | Tail-cuff occlusion with automated inflation/deflation |
| Temperature Control Range | 30–40 °C (adjustable via host or software) |
| Blood Pressure Range | 0–350 mmHg |
| Pulse Rate Range | 0–1000 BPM |
| Measured Parameters | Systolic BP, Mean Arterial Pressure (MAP), Diastolic BP, Heart Rate |
| Data Storage | SD card and/or PC via USB 2.0 |
| Software Features | Automated measurement initiation, post-acquisition editing, averaging (6–7 cycles), scheduled measurements, report generation (PDF/CSV), GLP-compliant audit trail export |
| Throughput | Up to 3 rodents per session (sequential) |
| Measurement Duration | ≤15 min (rats), ≤5 min (mice) |
| Compliance | Designed for ISO 13485-aligned manufacturing environments |
| Brand | RWD |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | SP0007-C |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Supplier Type | Authorized Distributor |
| Import Status | Imported |
| Model | Multi-Channel Animal Respirometry System |
| Price Range | USD 14,000 – 42,000 |
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | GA56 (56-cage configuration) |
| Price | USD 6,300 (approx.) |
| Air Changes per Hour | 10–20 (adjustable) |
| Airflow Velocity | ≤0.18 m/s |
| Static Pressure Gradient | 20–50 Pa (adjustable) |
| Cleanroom Class | < ISO Class 5 (≤100 particles ≥0.5 µm/ft³) |
| Settling Plate Microbial Count | <1 CFU/plate/4 h |
| Noise Level | <55 dB(A) |
| Cage Material | Medical-grade PSU (polyphenylsulfone), autoclavable at 150°C, 15 psi for 30 min |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | GA56 Cage |
| Pricing | Upon Request |
| Air Changes per Hour | 10–50 (adjustable) |
| Air Velocity | ≤0.18 m/s |
| Pressure Gradient | 20–50 Pa (adjustable) |
| Air Cleanliness Class | < ISO Class 5 (≤100 particles ≥0.5 µm/m³) |
| Settle Plate Microbial Count | <1 CFU/4 h |
| Noise Level | <55 dB(A) |
| Dimensions (W×D×H) | 1890 × 530 × 1750 mm |
| Rack Configuration | 7 tiers × 8 cages per tier |
| Cage Material | Medical-Grade PSU (Polyphenylsulfone), Autoclavable at 150°C, 15 psi for 30 min |
| Brand | EZ Scientific |
|---|---|
| Origin | Beijing, China |
| Model | 88110 |
| Animal Compatibility | Mouse, Rat, Rabbit, Cat |
| X/Y/Z Travel Range | 0–80 mm |
| Adjustment Resolution | 10 µm |
| X-Axis Rotation | −90° to +90° |
| Z-Axis Rotation | −45° to +45° |
| Display | 5-inch HD LED touchscreen |
| Power Options | AA batteries (low-noise operation) or optional rechargeable Li-ion battery |
| Sensor Interface | Imported industrial-grade connectors |
| Compliance | Designed for GLP-compliant neuroscientific research environments |
| Brand | EZ Vet |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ES9000 |
| Price Range | USD 700 – 1,400 |
| Brand | EZ Vet |
|---|---|
| Model | F500 |
| Animal Weight Capacity | ≤ 7.0 kg |
| Anesthetic Agents | Isoflurane and Sevoflurane compatible |
| Vaporizer Type | Precision calibrated, interchangeable dual-agent vaporizer |
| Safety Features | Agent lockout mechanism, large-view sapphire-reinforced glass gauge, coaxial scavenging-integrated breathing circuit |
| Form Factor | Benchtop (upgradable to mobile cart configuration) |
| Compliance | Designed per ISO 8536-4 (gas anesthesia equipment), meets GLP-aligned operational safety requirements for preclinical research environments |
| Price Range | USD 700 – 1,400 (FOB Beijing) |
| Brand | EZ Vet |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Region of Origin | Domestic (China) |
| Model | F670 |
| Price Range | USD 140 – 700 |
| Flow Rate | 8–60 L/min |
| Filter Initial Mass | 1200 g |
| Replacement Threshold | ≥1400 g |
| Noise Level | <20 dB(A) |
| Compatible Anesthetics | Isoflurane, Sevoflurane, Halothane |
| Not Compatible | Nitrous Oxide (N₂O) |
| Display | Color Touchscreen with Real-Time Flow, Pressure & Mass Readout |
| Safety Alerts | Low-Pressure Alarm, Overweight Filter Alarm, One-Touch Mute Function |
| Regulatory Compliance | Designed for GLP-aligned laboratory environments |