| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Packwin 2.0 |
| Price Range | USD 1,400 – 7,000 |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | PHD ULTRA Nanomite |
| Flow Rate Range | 3.66 pL/min to 3.818 mL/min |
| Accuracy | ±0.5% (stability), ±0.05% (repeatability) |
| Syringe Capacity | 0.5 µL – 1 mL |
| Linear Force | 5 kg (adjustable) |
| Display | 4.3" WQVGA TFT color touchscreen |
| Interfaces | USB, RS-485, TTL digital I/O, footswitch (9-pin D-Sub), optional RS-232 (RJ-11) |
| Compliance | CE, EU RoHS |
| Power | 100–240 VAC, 50/60 Hz, 75 W |
| Dimensions (Controller) | 30.5 × 21.6 × 11.1 cm |
| Weight (Controller) | 2.06 kg |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Post-Operative Recovery System |
| Pricing | Upon Request |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Not Specified |
| Pricing | Upon Request |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | PSMB5 / PSMT5 |
| Total Optical Magnification | 1.8×–40× |
| Eyepiece | 12.5× |
| Interpupillary Distance Adjustment | 50–70 mm |
| Diopter Adjustment | ±6 D |
| Working Distance (Focus Range) | 94–344 mm |
| Objective Focal Length | 200 mm (PSMB5), 350 mm (PSMT5, recommended for 103 cm mounting height) |
| Field of View | 58–10 mm (5-step zoom) |
| Fine Focus Travel | 30 mm |
| Articulated Arm Reach | Max. 870 mm radius |
| Vertical Travel Range | 700–1100 mm |
| Mounting Height Options | 89 cm or 103 cm (user-specified at order) |
| Dual Halogen Illumination | 12 V, 100 W cold mirror lamps with fiber-optic light guides |
| Camera Interface | C-mount optical port compatible with 1/2″ CCD sensors (e.g., WPI COLCAM, DC2000M) |
| Power Input | 110 V or 220 V, 50–60 Hz |
| Net Weight | 43 kg (94 lb) |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | PUMP 11 ELITE Nanomite 704507 |
| Precision | ±0.5% (accuracy), ±0.05% (repeatability) |
| Flow Range | 3.66 pL/min to 3.818 mL/min |
| Syringe Capacity | 0.5 µL–1 mL |
| Display | 4.3" WQVGA TFT color touchscreen |
| Motor Resolution | 0.198 µm/step |
| Linear Force | 5 kg |
| Power Input | 12–30 VDC / 100–240 VAC, 50/60 Hz |
| Certifications | CE, ETL (UL/CSA), WEEE, RoHS, CB Scheme |
| Interface | RS-232, USB, TTL footswitch, RS-485, IEEE-1394, 15-pin D-Sub, mini phono jack |
| Dimensions (Controller) | 22.6 × 17.78 × 15 cm |
| Weight | 1.96 kg |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | RGBP Research-Grade Invasive Blood Pressure Measurement System |
| Pricing | Available Upon Request |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | SAV 2500 |
| Pricing | Available Upon Request |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | SC100 |
| Certification | CE |
| Channel Configuration | Single-channel (upgradable to dual-channel with additional specimen platform) |
| Measurement Method | Oscillometric + Korotkoff-based non-invasive tail-cuff sphygmomanometry |
| Output Interfaces | BNC (BP, HR, ECG waveform), 9-pin serial (data logging & PC connectivity), Centronics printer port |
| Compatibility | Mice and rats (four standard tail-cuff balloon sizes included) |
| Data Acquisition | Digital signal processing, real-time pulse detection, configurable respiratory artifact filtering |
| Compliance | Designed for GLP-compliant preclinical research environments |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Size 5 |
| Pricing | Upon Request |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Small Animal Physiological Monitoring System |
| Instrument Type | Multi-Parameter Physiological Monitor |
| Measurement Parameters | Rectal Temperature, ECG, Respiration Rate, SpO₂, Non-Invasive Blood Pressure (NIBP), End-Tidal CO₂ (EtCO₂) |
| Heating Platform | Adjustable Thermostatic Surface (25–42 °C, ±0.1 °C stability) |
| Data Interface | Bluetooth 5.0 to Android Tablet (pre-installed monitoring software) |
| Data Export | CSV via USB or cloud-synced export to Windows/macOS workstations |
| Compliance | CE Marked, RoHS Compliant, Designed for GLP-Compliant Preclinical Research |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Size1 |
| Pricing | Upon Request |
| Brand | Harvard Apparatus |
|---|---|
| Country of Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Custom-Configurable Instrument Sets |
| Pricing | Available Upon Request |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Surgical Lights |
| Pricing | Contact for Quotation |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | Table Top |
| Gas Delivery System | Non-rebreathing, single-circuit |
| Vaporizer Type | TECH3 Isoflurane/Sevoflurane |
| Flow Range | 0–1000 mL/min (O₂) |
| Vapor Output Range | 0.5–5% |
| Weight | ~10 kg (unit + vaporizer) |
| Safety Features | Vaporizer lockout, visual drug level window, activated carbon scavenging system |
| Compliance | ASTM F2749-22 (Anesthetic Equipment), ISO 80601-2-13:2021 (Medical Electrical Equipment – Particular Requirements for Anesthetic Workstations) |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | Tabletop |
| Flowmeter Options | 0.2–4 L/min O₂, 0–1000 mL/min O₂, Dual O₂ (0.2–4 L/min + 0–1000 mL/min), or O₂ + N₂O with Fail-Safe Valve |
| Dimensions (W×D×H) | 30" × 20" × 32.5" (762 × 508 × 825.5 mm) |
| Weight | 25 lb (11.34 kg) |
| Animal Capacity | Single subject up to 4.5 kg |
| Circuit Type | Non-rebreathing |
| Compatible Vaporizers | Tech3, Tech4, Ohio, and 100-series |
| CO₂ Absorber | Optional standalone unit (Part #723010) |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | TC-3000 |
| Input Channels | Single or Triple Thermocouple |
| Temperature Range (Single-Channel) | 25.0–45.0 °C (0.1 °C resolution, Celsius only) |
| Temperature Range (Triple-Channel) | −10.0 to +60.0 °C (14.0 to 140.0 °F), 0.1 °C resolution |
| Sampling Rate | 3 Hz per channel |
| Power Supply | 4 × C-cell batteries (included) |
| Output | Analog voltage output (0–5 V DC, proportional to temperature) |
| Display | Front-panel LCD with manual channel selection |
| Compliance | CE-marked, RoHS-compliant, designed for laboratory use under GLP conditions |
| Brand | Harvard Apparatus |
|---|---|
| Model | Tech3, 100 Series |
| Origin | USA |
| Fill Type | Funnel-Fill |
| Anesthetic Agents | Isoflurane, Halothane, Sevoflurane |
| Dial Settings | 0.5% and 1.0% increments |
| Inlet/Outlet Taper | 22–23 mm |
| Sump Capacity | 135 mL (35 mL absorbed by wick) |
| Dimensions (L × W × H) | 5.75 in × 5.25 in × 7.25 in |
| Weight | 1.5 lbs |
| Flow & Temperature Compensation | Yes |
| Sight Glass | Single |
| Manifold Design | Tapered, no check valve |
| Labeling | Color-coated agent-specific identification |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TFA |
| Pricing | Upon Request |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TOPO |
| Pricing | Upon Request |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | Vaporstick Anesthesia Machine |
| Flow Rate Range | 0.2–4 L/min (O₂) |
| Optional N₂O Flowmeter | Yes |
| Fail-Safe Valve | Included (Model 723009) |
| Mounting | Z-Bracket Universal Vaporizer Holder |
| Circuit Type | Non-rebreathing (Jackson-Rees, Mapleson D) |
| Upgradeable to Rebreathing | Yes (with external CO₂ absorber) |
| Frame | 5-Point Castor Base with MRI-Compatible Option |
| Construction | FDA-Approved Polymer Housing |
| Surface Finish | Electrostatic Powder Coating |
| Dimensions (H×W) | 134 cm × 152.4 mm |
| Weight Capacity | Up to 4.5 kg Animals |
| Exhaust Management | Active Scavenging-Compatible Pop-up Exhaust Valve |
| Fresh Gas Outlet | Dedicated Non-rebreathing Port |
| Absorber Design | Sealed Canister with Optimized Soda Lime Exposure Geometry |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | VentElite |
| Price Range | USD 1,400 – 7,000 |
| Weight Range | 10 g – 1 kg |
| Species Compatibility | Mice to Guinea Pigs |
| Airway Connection | Inlet 3.6–3.8 mm (0.14–0.15 in), Outlet 4.0 mm (0.16 in) |
| Ventilation Modes | Volume-Controlled and Pressure-Controlled |
| Tidal Volume Range | 50 µL – 5 mL |
| Tidal Volume Resolution | 1 µL |
| Tidal Volume Accuracy | ±0.1 µL |
| Peak Inspiratory Pressure (PIP) Range | 0–125 cmH₂O |
| PIP Accuracy | ±1.75 cmH₂O |
| PIP Resolution | 2.5 cmH₂O |
| Respiratory Rate | 10–300 bpm |
| I | E Ratio: 20%–80% |
| Sigh Frequency | 1 per 10–999 breaths (adjustable) |
| Sigh Volume/Pressure | 0–20% of set tidal volume (VC mode) or PIP (PC mode) |
| Gas Supply | Medical air or non-flammable gas mixtures |
| Alarms | High/low pressure, system fault |
| Input/Output Signals | TTL-compatible (0–5 VDC, 5 mA) |
| Communication Interface | RS-485 |
| Display | 7-inch resistive touchscreen LCD |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Dimensions (W × D × H) | 31.8 × 20.3 × 11.3 cm (12.5 × 8.0 × 4.45 in) |
| Weight | 3.4 kg (7.6 lbs) |
| Warranty | 2 years |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | VentElite |
| Breathing Rate Range | 10–300 bpm |
| Tidal Volume Range | 0.05–5 mL |
| Inspiratory | Expiratory Ratio (I:E): 20–80% |
| Operating Voltage | 15 V DC, 25 W |
| Tidal Volume Resolution | 0.1 µL |
| Dimensions | 31.8 × 20.3 × 17.8 cm |
| Weight Range Supported | 10 g – 1 kg |
| Brand | TSE Systems |
|---|---|
| Origin | Germany |
| Model | Head Nose Only Units |
| Construction | Modular stainless steel or aluminum frame |
| Animal Compatibility | Mice to guinea pigs (customizable for other species) |
| Exposure Configuration | Head-only restraint with nasal inhalation pathway |
| Aerosol Delivery | Integrated aerosol inlet ports with optional conditioning unit |
| Environmental Monitoring | Sensor ports for real-time temperature, humidity, and aerosol concentration monitoring |
| Mobility Option | Castor-mounted mobile base with locking brakes |
| Compliance | Designed per OECD TG 412, ASTM E1709, and ISO 10993-12 guidelines |
| Regulatory Support | Compatible with GLP-compliant data acquisition and audit-trail-enabled software integration |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | Heated Rodent Table |
| Heating Surface Area | 20 × 26 cm (8 × 10 in) |
| Accessories | Four stainless steel rods (6.5 mm / 0.25 in diameter), four tying cleats |
| Brand | RWD |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | F31037-14 |
| Price | Upon Request |
| Brand | Hengmei |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HM-KC |
| CO₂ Analysis Principle | Dual-Wavelength NDIR |
| CO₂ Range | 0–5% |
| CO₂ Resolution | ≤0.1 ppm |
| CO₂ Accuracy | ±1% FS |
| O₂ Range | 0–100% |
| O₂ Resolution | 0.0001% |
| O₂ Accuracy | ±0.1% FS |
| Flow Control Range | 5–1000 mL/min |
| Flow Resolution | 1 mL/min |
| Flow Accuracy | ±2% |
| Response Time (CO₂) | <1 s |
| 24-h Drift (CO₂) | <0.02% FS |
| Sample Compatibility | Drosophila, Aphids, Nematodes, Spiders, Lepidopteran Larvae/Pupae, Bees, Grasshoppers, Soil Invertebrates |
| Brand | Histrong |
|---|---|
| Model | HC-800 |
| Measurement Range | 0–190 mg/L and 0–12,000 mg/L |
| Sample Types | Urine, Serum, Saliva, Aqueous Solutions |
| Resolution | 0.01 mg/L |
| Analysis Time | <3 min per sample |
| Display | Dual-output (LCD + Thermal Printer) |
| Communication Interfaces | RS232, USB 2.0 |
| Power Supply | AC 220 V ±10%, 50 Hz, <60 W |
| Dimensions | 38.5 × 23.5 × 34.5 cm |
| Operating Environment | 10–35 °C, RH <85%, Low Magnetic Interference |
| Compliance | Designed for GLP-compliant laboratory workflows |
| Software Option | Optional LIMS-integrated data management module |
| Brand | Hope-Med |
|---|---|
| Origin | Tianjin, China |
| Model | 8052DS |
| Chamber Operating Pressure Range | −20 Pa to 0 Pa (gauge, negative pressure mode) |
| Animal Capacity | Up to 25 kg (e.g., Beagle dogs) |
| Number of Exposure Ports | ≥4 |
| Aerosol Concentration Capability | ≥10,000 mg/m³ (liquid/solid aerosols) |
| Inter-port Uniformity | ±10% for gas & liquid aerosols |
| Construction | Stainless steel main frame with chemically resistant soft-contact interior surfaces |
| Fault Monitoring | Real-time alerts for condensate accumulation, electrical faults, pressure, temperature, relative humidity, O₂, and CO₂ deviations |
| Compliance | Designed to support OECD 412, ASTM E171, ISO 10993-12, and GLP-aligned inhalation toxicology workflows |
| Brand | Eicom (Japan) |
|---|---|
| Manufacturer | RWD (Shenzhen, China) |
| Configuration | Modular HPLC with Dual-Electrode ECD-700 Detector, Pulse-Free EP-700 Pump, and ATC-700 Column Oven |
| Compliance | Designed for GLP/GMP-aligned neurochemical analysis workflows |
| Software Interface | Eicom PowerChrom v5.x (FDA 21 CFR Part 11–ready audit trail optional) |
| Detection Principle | Amperometric electrochemical detection in flow cell configuration |
| Electrode Configurability | Dual working electrode support (e.g., glassy carbon + platinum), independent potential control per channel |
| Sensitivity | ≤30 fg dopamine (S/N = 3, 10 µL injection, 3 mm electrode) |
| Flow Compatibility | 0.01–2.0 mL/min, compatible with analytical (2.1–4.6 mm ID) and microbore columns |