Automatic Potentiometric Titrator
Filter
Showing 91–120 of 211 results
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | MT-V6 |
| Instrument Type | General-Purpose Potentiometric Titrator |
| Application Scope | Universal |
| pH Measurement Range | 0.000–14.000, Resolution: 0.001 pH |
| Meter Accuracy | ±0.1 mV |
| Meter Resolution | 0.1 mV |
| Burette Precision | 20 mL standard burette / 1 µL |
| Potential Input Range | ±2000 mV, Resolution: 0.1 mV |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | MT-V6 Acid-Base Titrator |
| Instrument Type | General-Purpose Potentiometric Titrator |
| Application Scope | Universal |
| pH Measurement Range | 0.000–14.000 |
| pH Resolution | 0.001 |
| Meter Accuracy | ±0.1 mV |
| Meter Resolution | 0.1 mV |
| Burette Precision | ±1 µL (20 mL standard burette) / ±0.5 µL (10 mL optional burette) |
| Potential Range | ±2000 mV |
| Potential Resolution | 0.1 mV |
| Potential Accuracy | ±0.2 mV |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | General-Purpose Potentiometric Titrator |
| Application Scope | Universal |
| pH Measurement Range | 0.000–14.000 (Resolution: 0.001 pH) |
| mV Measurement Range | ±2000.0 mV (Resolution: 0.1 mV |
| Accuracy | ±0.1 mV) |
| Temperature Range | −5 to 125 °C (Resolution: 0.1 °C) |
| Burette Precision | 1 µL (20 mL standard burette) |
| Burette Resolution | 0.5 µL (10 mL optional burette) |
| Endpoint Detection Modes | EQP (Equivalence Point), EP (Endpoint) |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | TCl-1 |
| Instrument Type | General-Purpose Potentiometric Titrator |
| Application Scope | Cement-Specific |
| Potential Range | ±2000 mV |
| pH Range | 0–14 pH |
| Potential Resolution | 0.01 mV |
| pH Resolution | 0.01 |
| Temperature Range | 0–100 °C |
| Temperature Resolution | 0.1 °C |
| Titration Volume | 20 mL |
| Minimum Dispensing Increment | 0.001 mL per step |
| Titration Repeatability | RSD ≤ 1% |
| Titration Accuracy | ±1 µL |
| Potential Measurement Accuracy | ±0.3 mV ±1 digit over 3 h |
| Electrode System | Chloride Ion-Selective Electrode + Double-Junction Saturated Calomel Reference Electrode (Outer Junction: KNO₃ |
| Inner Junction | KCl) |
| Data Export | PDF via USB or WLAN |
| GLP Compliance | Electrode calibration logs, titrant standardization records, user operation audit trail, non-overwritable data history |
| Environmental Operating Conditions | 5–35 °C, ≤80% RH |
| Power Supply | 100–220 V AC, 50–60 Hz |
| Dimensions (W×D×H) | 250 × 360 × 330 mm |
| Weight | 10 kg |
| Brand | Kyoto Electronics Manufacturing (KEM) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | AT-710 + CHA-700 |
| Instrument Type | General-purpose Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Range | pH: −20.000 to +20.000 |
| mV | −2000.0 to +2000.0 |
| Temperature | 0 to 100 °C |
| Meter Accuracy | ±0.2% of full scale |
| Meter Resolution | pH: 0.001 pH |
| mV | 0.1 mV |
| Temperature | 0.1 °C |
| Titration Endpoint Precision | ±0.3 mV |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | AT-710B |
| Instrument Type | General-purpose Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Range | pH: −20.000 to +20.000 |
| mV | −2000.0 to +2000.0 mV |
| Temperature | 0 to 100 °C |
| Burette Accuracy (20 mL) | ±0.02 mL |
| Burette Resolution (20 mL) | 0.001 mL |
| Burette Precision (20 mL) | ±0.01 mL |
| Burette Resolution Ratio | 1/20,000 |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | AT-710M |
| Instrument Type | General-Purpose Potentiometric Titrator |
| Application Scope | Universal Analytical Titration |
| Measurement Range | pH: −20.000 to +20.000 |
| mV | −2000.0 to +2000.0 |
| Temperature | 0 to 100 °C |
| Burette Accuracy (20 mL) | ±0.02 mL |
| Burette Resolution (20 mL) | 0.001 mL |
| Dispensing Precision (20 mL) | ±0.01 mL |
| Burette Resolution Ratio | 1/20,000 |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | AT-710S |
| Instrument Type | General-purpose Potentiometric Titrator |
| Application Scope | Universal Analytical Titration |
| Measurement Range | pH: −20.000 to +20.000 |
| mV | −2000.0 to +2000.0 |
| Temperature | 0–100 °C |
| Burette Accuracy (20 mL) | ±0.02 mL |
| Burette Resolution (20 mL) | 0.001 mL |
| Electrode Reading Precision | ±0.01 mL |
| Burette Resolution Ratio | 1/20,000 |
| Brand | Kyoto Electronics Manufacturing (KEM) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | AT-Win |
| Instrument Type | Universal Potentiometric Titrator |
| Application Scope | General-purpose quantitative chemical analysis |
| Measurement Range | pH: –20.000 to +20.000 |
| mV | –2000.0 to +2000.0 |
| Temperature | 0 to 100 °C |
| Burette Accuracy (20 mL) | ±0.02 mL |
| Burette Resolution (20 mL) | 0.001 mL |
| Electrode Readout Accuracy | ±0.01 mL (20 mL burette) |
| Digital Resolution | 1/20000 |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported Instrument |
| Model | CHA-600 |
| Instrument Category | General-Purpose Automatic Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Ranges | pH: −20 to +20 |
| mV | −2000 to +2000 |
| Temperature | 0–100 °C |
| Burette Accuracy (20 mL) | ±0.01 mL |
| Burette Resolution (20 mL) | 0.001 mL |
| Titration Precision (20 mL) | ±0.02 mL |
| Sample Capacity | CHA-600-12: 12 × 200 mL (PP) or 300 mL tall-form beakers |
| CHA-600-18 | 18 × 100 mL (PP) or 50 mL beakers |
| Washing Method | Standard rinse (optional dual-solvent wash) |
| Washing Reservoir | Dedicated independent wash station |
| Wash Liquids | Deionized water, ethanol, acetic acid, or other compatible solvents |
| Stirring | Magnetic stir bar (optional propeller stirrer) |
| Ambient Operating Conditions | 5–35 °C, ≤85% RH |
| Power Supply | 100–120 V / 200–240 V AC, 50/60 Hz, ~50 W |
| Dimensions (W×D×H) | 520 × 426 × 369 mm |
| Weight | ~18 kg |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Kyoto Electronics Manufacturing Co., Ltd. |
| Type | Imported Instrument |
| Model | CHA-740 / CHA-760 |
| Instrument Category | General-purpose Potentiometric Titrator |
| Application Scope | Universal |
| Potential Range | −2000.0 mV to +2000.0 mV |
| pH Range | −20.000 to +20.000 pH |
| Burette Accuracy | ±0.01 mL (20 mL burette) |
| Burette Resolution | 0.001 mL (20 mL burette) |
| Titration Precision | ±0.02 mL (20 mL burette) |
| Sample Capacity | 24 (CHA-740) / 47 (CHA-760) positions |
| Washing Modes | Rinse & Immersion, up to 3 wash solutions |
| Wash Liquids | Deionized water, ethanol, acetic acid, etc. |
| Operating Environment | 5–35 °C, ≤85 % RH |
| Power Supply | DC 24 V / 5 A (changer unit), AC 100–240 V / ~120 W |
| Dimensions (W×D×H) | 805×660×540 mm (CHA-740), 1005×760×540 mm (CHA-760) |
| Standard Sample Vessels | 200 mL plastic beakers, 200/250/300 mL glass beakers, tall-form beakers, Erlenmeyer flasks |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model Designation | Electrode Series for DV-100 / AT-710 / AT-710M Titrators |
| Measurement Range | ±20 pH, ±2000 mV |
| Meter Accuracy | ±0.2% of full scale |
| Meter Resolution | 0.001 pH, 0.1 mV |
| Titration Potential Stability | ±0.3 mV |
| Analog-to-Digital Resolution | 1/20000 (16-bit ADC) |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Kyoto Electronics Manufacturing Co., Ltd. |
| Type | Imported Instrument |
| Model | PCD-500 |
| Instrument Category | General-Purpose Automatic Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Principle | Streaming Potential Detection |
| Electrode Output Range | ±2 V DC |
| Power Supply | AC 100–240 V ±10%, 50/60 Hz |
| Power Consumption | ~10 W |
| Dimensions (W×D×H) | 250 × 210 × 400 mm |
| Weight | ~4.5 kg |
| Sample Handling | Stirred beaker-based immersion configuration |
| Piston Actuation | Continuously variable vertical reciprocation |
| Minimum Detectable Charge Concentration | ≥1 × 10⁻⁵ mol/L (dilution required for high-concentration samples) |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | FJA-2 |
| Instrument Type | Universal Potentiometric Titrator |
| Voltage Measurement Range | −1999.9 to +1999.9 mV |
| Resolution | 0.1 mV |
| Voltage Accuracy | ±0.025% of reading ±2 digits |
| Input Impedance | >10¹² Ω |
| Titration Precision | 0.01 mL |
| Minimum Dispensed Volume | 0.001 mL |
| Titration Error | ≤0.2% (using 0.1 mol/L HCl vs. 0.1 mol/L NaOH) |
| Compliance | GB/T 1792–1988 (mercaptan sulfur in petroleum products) |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | JXD-2 |
| Instrument Type | Alkaline Nitrogen & Mercaptan Sulfur Analyzer |
| Measurement Range | ≥3 µg/g |
| Potential Range | 0 to ±1999.9 mV, Resolution: 0.1 mV |
| Potential Accuracy | ±0.025% of reading + 2 digits |
| Input Impedance | ≥1 × 10¹² Ω |
| Burette Capacity | 10 mL, Minimum Dispense Volume: 0.01 mL |
| Relative Error | ≤5% |
| Repeatability | Compliant with SH/T 0162 |
| Dimensions | 240 × 120 × 210 mm |
| Weight | 5 kg |
| Power Consumption | ≤10 W |
| Brand | Keyuan Instruments |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | KY-210B |
| Instrument Type | Universal Potentiometric Titrator |
| Application Scope | General-purpose |
| Bias Voltage Range | 0–500 mV (adjustable) |
| Chloride Ion Measurement Range | 0.1 ppm to full percentage content |
| Accuracy | < ±2% |
| Repeatability | ≤ ±0.1 mg NaCl/L (for samples ≤2 mg NaCl/L) |
| Detection Sensitivity | Cl⁻: 0.1 mg/L |
| Titration Cell Volume | 145 mL |
| Sample Mass | 0.02–0.05 g |
| Dimensions (W×D×H) | 465 × 280 × 195 mm |
| Power Consumption | 40 W |
| Operating Environment | 10–40 °C, RH ≤80%, low electromagnetic interference |
| Brand | Keyuan Instruments |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Universal Potentiometric Titrator |
| Model | KY-4Br |
| Measurement Principle | Coulometric Titration (Microcoulometry) |
| Measurement Range | Bromine Number: 0–300 g Br/100g oil |
| Bromine Index | 1–1000 mg Br/100g oil |
| Detection Limit | 1 mg Br |
| Accuracy | ±3% ±0.2 g Br (bromine number) |
| Resolution | 0.01 mg Br |
| Bias Voltage Range | 0–500 mV |
| Sample Volume | <10 µL (bromine number) |
| Reagent Consumption | <1 mL per sample |
| Power Consumption | 20 W |
| Compliance Standards | SH/T 0630–1996, SH/T 1551–2018, GB/T 11136–1989(2004), SH/T 1767–2008(2015), GB/T 1815–1997, ASTM D1492 |
| Brand | Keyuan Instruments |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | KY-4D |
| Instrument Type | Alkaline Nitrogen & Mercaptan Sulfur Analyzer |
| Application Scope | General-purpose petroleum product analysis |
| Measurement Range | ≥3 µg/g |
| Burette Resolution | 0.01 mL |
| Potentiometric Accuracy | ±0.1% F.S. |
| Potential Measurement Range | (0 to ±1999.5) mV |
| Brand | Keyuan Instruments |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Region of Origin | Domestic (China) |
| Model | KY-6 |
| Instrument Category | Automatic Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Range | ≥0.001 mg KOH/g |
| Potentiometric Measurement Range | −2000.0 to +2000.0 mV |
| Electronic Unit Basic Error | ±0.1% F·S ± 0.1 mV |
| Input Impedance | ≥1 × 10¹² Ω |
| Burette Capacity | 10 mL |
| Minimum Dispensing Volume | 0.001 mL |
| Burette Accuracy | ±0.1% F·S |
| Titration Accuracy | ±0.1% F·S |
| Endpoint Detection | Adaptive endpoint recognition via smoothed titration curve analysis |
| Compliance Standards | GB/T 7304–2000, GB/T 18609–2010 |
| Brand | Kyoyuan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic |
| Model | KY-4 |
| Instrument Type | Basic Nitrogen & Mercaptan Sulfur Analyzer |
| Application Scope | Dedicated Analyzer |
| Sample Form | Liquid |
| Measurement Range | ≥3 µg/g |
| Titration Method | Potentiometric Titration |
| Minimum Titration Volume | 0.01 mL |
| Potential Measurement Range | 0 to ±1999.5 mV |
| Burette Accuracy | ±0.1% F·S |
| Electronic Unit Basic Error | ±0.1% of full scale + 0.5 mV |
| Accuracy | Relative error ≤5% |
| Compliance Standard | SH/T 0162 |
| Brand | Kyoyuan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Universal Potentiometric Titrator |
| Application Scope | Dedicated for Hydrocarbon Analysis |
| Bromine Number Range | 0–300 g Br/100 g oil |
| Bromine Index Range | 1–1000 mg Br/100 g oil |
| Potential Measurement Accuracy | 0.1 mV ± 0.03% |
| Potential Resolution | 0.1 mV |
| Titration Volume Precision | 0.001 mL |
| Bromine Mass Resolution | 0.01 mg Br |
| Detection Limit | 0.1 mg Br |
| Accuracy | ±5% (bromine index ≥ 1 mg Br/100 g oil) |
| Bias Voltage Range | 0–500 mV |
| Cell Volume | 150 mL |
| Stirring Method | Magnetic Stirring |
| Power Supply | 220 V, 50 Hz |
| Power Consumption | 20 W |
| Weight | ~1.6 kg |
| Brand | Lasertec |
|---|---|
| Origin | Japan |
| Model | GT-200 |
| Instrument Type | General-purpose Potentiometric Titrator |
| Application Scope | Specialized (e.g., Acid Number Determination in Gasoline) |
| Display | 5.7-inch Color LCD |
| Connectivity | USB, RS-232 (COM), GLP-compliant Data Logging |
| Software | Titration Viewer TV-200 |
| Automation Capacity | Up to 12 burettes + 24-position autosampler |
| Endpoint Detection | Smart End Point Detection (S.E.D.) Algorithm |
| Compliance | GLP Support (Calibration Traceability, User Access Levels, Audit Trail) |
| Brand | Leichi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | ZDCL-1 |
| Instrument Category | General-Purpose Potentiometric Titrator |
| Application Scope | Dedicated for Chloride Ion Analysis |
| Measurement Range | (−1800.0 to +1800.0) mV |
| Meter Accuracy | ±0.20% of full scale |
| Meter Resolution | 0.1 mV |
| Titration Accuracy | (±0.3 mV ±1 digit) over 3 h |
| Titration Resolution | 1/10000 |
| Titration Repeatability | 0.20% |
| Burette Error | ±0.025 mL (10 mL burette), ±0.035 mL (20 mL burette) |
| Electronic Unit Basic Error | ±0.05% FS |
| Stability | ±0.3 mV / 3 h |
| Operating Environment | 0–40 °C, ≤85% RH |
| Dimensions & Weight | 340 × 400 × 400 mm, ~10 kg |
| Power Supply | AC (220 ± 22) V, (50 ± 1) Hz |
| Brand | Leichi |
|---|---|
| Origin | Shanghai, China |
| Model | ZDCL-2 |
| Measurement Range | (−1800.0 to +1800.0) mV |
| Potential Resolution | 0.1 mV |
| Potential Accuracy | ±0.2 mV |
| Stability | (±0.3 mV ±1 digit)/3 h |
| Titration Resolution | 1/10000 (for 10 mL burette) |
| Titration Precision | ≤0.20% RSD |
| Burette Error | ±0.025 mL (10 mL), ±0.035 mL (20 mL) |
| Temperature Compensation Range | (−5.0 to 105.0) °C, Resolution: 0.1 °C, Accuracy: ±0.3 °C |
| Interface | RS232 |
| Data Storage | 200 titration results + 1 full dataset |
| Compliance | GB/T 176–2017, GB/T 8077–2012, GB 50344–2004, JGJ/T 322–2013 |
| Brand | Leichi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | ZDJ-4D |
| Instrument Category | General-Purpose Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Range | mV: −2000.0 to +2000.0 mV |
| pH | −5.000 to 20.000 |
| Potentiometric Resolution | 0.01 mV |
| Titration Volume Resolution | 1/20000 |
| Brand | Leichi |
|---|---|
| Origin | Shanghai, China |
| Model | ZDJ-5 |
| Instrument Type | General-purpose Potentiometric Titrator |
| Application Scope | Universal |
| pH Range | 0.00–14.00 pH |
| mV Range | 0–±1999.0 mV |
| Temperature Range | −5.0–105.0 °C |
| pH Resolution | 0.01 pH |
| mV Resolution | 0.1 mV |
| Temperature Resolution | 0.1 °C |
| pH Accuracy | ±0.01 pH ± 1 digit |
| mV Accuracy | ±0.03% FS |
| Temperature Accuracy | ±0.3 °C ± 1 digit |
| Conductivity Range | 0.000–199.9 µS/cm |
| Conductivity Resolution | 0.001 µS/cm |
| Conductivity Accuracy | ±0.5% FS |
| Polarographic Current Ranges | 0–199.9 µA, 0–19.99 µA, 0–1.999 µA, 0–0.199 µA |
| Polarization Voltage Options | 3, 50, 100 mV |
| Titration Precision | ±0.03% FS |
| Titration Resolution | 1/1,500,000 |
| Endpoint Detection Sensitivity (Potentiometric) | ±2 mV |
| Endpoint Detection Sensitivity (Amperometric) | ±5% FS |
| Repeatability of Titration Analysis | 0.2% |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | SR-1 Robotic Autosampler + ZDJ-6 Titration Unit |
| Application Scope | General-purpose potentiometric titration |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Model | ZDCL-1 |
| Instrument Type | General-purpose Potentiometric Titrator |
| Application Scope | Dedicated for Chloride Ion Determination |
| Measurement Range | (−1800.0 to +1800.0) mV |
| Potentiometer Accuracy | ±0.20% of full scale |
| Potentiometer Resolution | 0.1 mV |
| Titration Accuracy | (±0.3 mV ±1 digit) over 3 h |
| Titration Resolution | 1/10000 |
| Burette Capacity | 10 mL |
| Burette Error | ±0.025 mL |
| Burette Delivery Time | (55 ± 10) s (at full scale) |
| Temperature Compensation Range | (−5.0 to 105.0) °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.3 °C |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | ZDCL-2 |
| Instrument Category | General-Purpose Potentiometric Titrator |
| Application Specificity | Dedicated for Chloride Ion Analysis |
| Measurement Range | (−1800.0 to +1800.0) mV |
| Meter Accuracy | ±0.20% of full scale |
| Meter Resolution | 0.1 mV |
| Titration Accuracy | (±0.3 mV ±1 digit) over 3 hours |
| Titration Resolution | 1/10,000 |
| Titration Repeatability | ≤0.20% |
| Burette Error | ±0.025 mL (10 mL burette), ±0.035 mL (20 mL burette) |
| Stability | ±0.3 mV / 3 h |
| Operating Environment | 0–40 °C, ≤85% RH |
| Dimensions & Weight | 340 × 400 × 400 mm, ~10 kg |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | ZDJ-3A |
| Instrument Type | General-Purpose Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Range | (−1999 to +1999) mV, (0.00 to 14.00) pH |
| Meter Accuracy | ±0.3% of full scale |
| Meter Resolution | 1 mV, 0.01 pH |
| Titration Stability | ±1 mV / 3 h |
| Burette Resolution | 10 mL burette: 1/20000 |
| 20 mL burette | 1/10000 |
| Burette Accuracy | 10 mL: ±0.05 mL |
| 20 mL | ±0.07 mL |
| Titration Repeatability | 0.3% |
| Power Supply | AC (220 ± 22) V, (50 ± 1) Hz |
| Dimensions (W×D×H) | 340 × 400 × 400 mm |
| Weight | 10 kg |