| Brand | Dantec Dynamics |
|---|---|
| Origin | Denmark |
| Model | MiniPIV |
| Measurement Plane | 2D/3D |
| Frame Rate | >100 Hz |
| Velocity Range | 0–5 m/s |
| Accuracy | ±1% of reading |
| Measurement Area | 150 mm × 120 mm |
| Camera | FlowSense USB 2M-165 (1920 × 1200 px, 165 fps) |
| Laser Source | RayPower (2/5/10 W, air-cooled, TEM₀₀ mode) |
| Software Platform | DynamicStudio |
| Brand | Dantec |
|---|---|
| Origin | Denmark |
| Model | FiberFlow |
| Flow Measurement Principle | Laser Doppler Anemometry (LDA) |
| Velocity Range | 0–1500 m/s |
| Velocity Uncertainty | < 0.1% |
| Measurement Dimensionality | 1D, 2D, and 3D vector velocity |
| Optical Stability | High (thermally compensated interferometric design) |
| Particle Requirement | Seeded flow (with reflective/scattering particles) |
| Installation Type | Benchtop or integrated rig-mount |
| Compliance | ISO 9001-manufactured, compatible with GLP/GMP data integrity workflows (audit trail, user access levels, electronic signatures via optional software modules) |
| Brand | Dantec Dynamics |
|---|---|
| Origin | Denmark |
| Manufacturer Status | Authorized Distributor |
| Import Category | Imported |
| Model | Low-Frequency PIV |
| Measurement Capability | Planar (2D/3D) |
| Measurement Frequency | Low-Frequency |
| Velocity Range | 0–1000 m/s |
| Accuracy | ±1% |
| Measurement Area | 200 mm × 200 mm to 1000 mm × 1000 mm |
| Brand | Dantec |
|---|---|
| Origin | Denmark |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | StreamLine Pro |
| Product Type | Electromagnetic |
| Price Range | USD 13,500 – 40,500 (based on configuration and probe options) |
| Brand | Dantec Dynamics |
|---|---|
| Origin | Denmark |
| Model | MicroPIV |
| Measurement Domain | 15 µm × 15 µm to 3 mm × 3 mm |
| Velocity Range | 0–2 m/s |
| Accuracy | ±1% of measured velocity |
| Spatial Resolution | Down to ~1 µm (dependent on optics & particle seeding) |
| Temporal Resolution | Low-frequency operation (typically < 100 Hz, configurable via laser pulse separation and camera frame rate) |
| Optical Configuration | Inverted fluorescence microscope optimized for PIV |
| Camera Option | HiSense MkII sCMOS sensor with peak quantum efficiency of 72% |
| Upgrade Paths | Unstructured grid PIV, MicroLIF (Micro Laser-Induced Fluorescence) |
| Brand | Dantec |
|---|---|
| Origin | Denmark |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | FlowExplorer |
| Price Range | USD 13,500 – 40,500 (est. based on ¥100,000–300,000 @ 7.4 CNY/USD) |
| Type | Volumetric Flow Measurement System |
| Laser Source | DPSS |
| Output Power Options | 70 mW / 150 mW / 500 mW |
| Measurement Distance Options | 150 mm / 300 mm / 500 mm / 750 mm |
| Signal Processor Models | BSA F600 / BSA F800 |
| Max Processing Frequency | 120 MHz / 200 MHz |
| Max Measurable Velocity (lens-dependent) | 432 m/s / 798 m/s |
| Data Acquisition Rate | >100,000 bursts/sec |
| ADC Resolution | 16-bit |
| Calibration | NIST-traceable certificate included |
| Connectivity | Wi-Fi enabled |
| Integrated Oscilloscope Functionality | Yes |
| Brand | Dantec Dynamics |
|---|---|
| Origin | Denmark |
| Model | FiberPDA |
| Type | Phase Doppler Anemometer (PDA) |
| Measurement Principle | Phase Doppler Interferometry |
| Velocity Range | –300 to +1000 m/s |
| Particle Diameter Range | 0.5 µm to 10,000 µm |
| Velocity Uncertainty | ±0.1% of reading |
| Size Accuracy | <1% |
| Dynamic Range | 1:50 |
| Optical Configuration | Fiber-coupled dual-beam interferometric setup |
| Signal Processing | Real-time digital pulse processing with adaptive thresholding and burst-mode analysis |
| Brand | Dantec Dynamics |
|---|---|
| Origin | Denmark |
| Model | VV |
| Measurement Capability | 3D3C (Three-Dimensional, Three-Component) |
| Velocity Range | 0–300 m/s |
| Measurement Volume | 200 mm × 200 mm × 40 mm |
| Accuracy | ±1% of measured velocity |
| Temporal Resolution | Low-frequency acquisition (configurable via camera framing rate and laser repetition rate) |
| Particle Seeding Density | 0.05–0.07 particles per pixel (PPP) |
| Camera Configuration | 2–4 synchronized high-speed CMOS cameras |
| Illumination | Volumetric light sheet or tomographic LED/laser array |
| Software Platform | DynamicStudio with GPU-accelerated volumetric reconstruction (up to 240 CUDA cores) |
| Brand | Dantec |
|---|---|
| Origin | Denmark |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | FlowMap |
| Pricing | Upon Request |
| OH Excitation Laser Energy | 22–25 mJ per Pulse |
| ICCD Gating Width | 3 ns |
| Photocathode Quantum Efficiency | ~30% |
| CCD Quantum Efficiency | ~70% |
| Synchronizer Timing Resolution | 250 ps |
| Brand | Dantec Dynamics |
|---|---|
| Origin | Denmark |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | 81X30 |
| Measurement Capability | Planar (2D/3D) |
| Frame Rate | >100 Hz |
| Velocity Range | 0–0.5 m/s |
| Accuracy | ±1% of full scale |
| Measurement Area | 190 mm × 120 mm |
| Illumination Source | High-power pulsed LED array with fiber-coupled lens system |
| Camera | FlowSense USB 2M-165 (2 MP, global shutter, 165 fps @ full resolution) |
| Synchronization | Software-controlled via DynamicStudio v7.x |
| Data Acquisition & Analysis | DynamicStudio PIV software suite |