- All
- Favorite
- Popular
- Most rated
| Brand | Dantec Dynamics |
|---|---|
| Origin | Germany |
| Model | RTSS Q-410 |
| Measurement Principle | Digital Image Correlation (DIC)-based Real-Time Strain Sensing |
| Sampling Rate | Up to 4,000 Hz |
| Output Interface | Analog (±10 V) and Digital (Ethernet, TTL Sync) |
| Compliance | CE, RoHS |
| Supplier Status | Authorized Distributor |
| Origin Category | Imported Instrument |
| Brand | Dantec Dynamics |
|---|---|
| Origin | Denmark |
| Model | MiniPIV |
| Measurement Plane | 2D/3D |
| Frame Rate | >100 Hz |
| Velocity Range | 0–5 m/s |
| Accuracy | ±1% of reading |
| Measurement Area | 150 mm × 120 mm |
| Camera | FlowSense USB 2M-165 (1920 × 1200 px, 165 fps) |
| Laser Source | RayPower (2/5/10 W, air-cooled, TEM₀₀ mode) |
| Software Platform | DynamicStudio |
| Brand | Dantec Dynamics |
|---|---|
| Origin | Germany |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | Q-400μDIC |
| Pricing | Available Upon Request |
| Measurement Dimensions | 2D & 3D |
| Measurement Area | 0.1 mm × 0.1 mm to 17 mm × 17 mm |
| Displacement Resolution | 1 µm |
| Strain Resolution | 0.005% |
| Application Focus | Microelectronics, Biomaterials, Thermal Expansion Analysis, Warpage Characterization |
| Brand | Dantec |
|---|---|
| Origin | Denmark |
| Model | FiberFlow |
| Flow Measurement Principle | Laser Doppler Anemometry (LDA) |
| Velocity Range | 0–1500 m/s |
| Velocity Uncertainty | < 0.1% |
| Measurement Dimensionality | 1D, 2D, and 3D vector velocity |
| Optical Stability | High (thermally compensated interferometric design) |
| Particle Requirement | Seeded flow (with reflective/scattering particles) |
| Installation Type | Benchtop or integrated rig-mount |
| Compliance | ISO 9001-manufactured, compatible with GLP/GMP data integrity workflows (audit trail, user access levels, electronic signatures via optional software modules) |
| Brand | Dantec Dynamics |
|---|---|
| Origin | Germany |
| Model | Q-480 |
| Distribution Status | Authorized Distributor |
| Origin Category | Imported |
| Pricing | Upon Request |
| Brand | Dantec Dynamics |
|---|---|
| Origin | Germany |
| Model | Q-400TCT |
| Measurement Dimensions | 2D & 3D |
| Measurement Area | 20 mm × 20 mm to 250 mm × 250 mm |
| Displacement Resolution | 1 µm |
| Strain Range | 0.005% – 100% |
| Temperature Control Stage | −40 °C to +300 °C |
| Heating/Cooling Rate | up to 50 °C/min |
| Brand | Dantec Dynamics |
|---|---|
| Origin | Denmark |
| Manufacturer Status | Authorized Distributor |
| Import Category | Imported |
| Model | Low-Frequency PIV |
| Measurement Capability | Planar (2D/3D) |
| Measurement Frequency | Low-Frequency |
| Velocity Range | 0–1000 m/s |
| Accuracy | ±1% |
| Measurement Area | 200 mm × 200 mm to 1000 mm × 1000 mm |
| Brand | Dantec Dynamics |
|---|---|
| Origin | Germany |
| Model | Q-400 |
| Measurement Dimensions | 2D & 3D |
| Measurable Area | 10 mm × 10 mm to 5 m × 5 m |
| Displacement Resolution | 1 µm |
| Strain Resolution | 0.005% |
| Compliance | ISO/IEC 17025-aligned calibration traceable to PTB (Physikalisch-Technische Bundesanstalt) |
| Brand | Dantec |
|---|---|
| Origin | Denmark |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | StreamLine Pro |
| Product Type | Electromagnetic |
| Price Range | USD 13,500 – 40,500 (based on configuration and probe options) |
| Brand | Dantec Dynamics |
|---|---|
| Origin | Denmark |
| Model | MicroPIV |
| Measurement Domain | 15 µm × 15 µm to 3 mm × 3 mm |
| Velocity Range | 0–2 m/s |
| Accuracy | ±1% of measured velocity |
| Spatial Resolution | Down to ~1 µm (dependent on optics & particle seeding) |
| Temporal Resolution | Low-frequency operation (typically < 100 Hz, configurable via laser pulse separation and camera frame rate) |
| Optical Configuration | Inverted fluorescence microscope optimized for PIV |
| Camera Option | HiSense MkII sCMOS sensor with peak quantum efficiency of 72% |
| Upgrade Paths | Unstructured grid PIV, MicroLIF (Micro Laser-Induced Fluorescence) |
| Brand | Dantec |
|---|---|
| Origin | Denmark |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | FlowExplorer |
| Price Range | USD 13,500 – 40,500 (est. based on ¥100,000–300,000 @ 7.4 CNY/USD) |
| Type | Volumetric Flow Measurement System |
| Laser Source | DPSS |
| Output Power Options | 70 mW / 150 mW / 500 mW |
| Measurement Distance Options | 150 mm / 300 mm / 500 mm / 750 mm |
| Signal Processor Models | BSA F600 / BSA F800 |
| Max Processing Frequency | 120 MHz / 200 MHz |
| Max Measurable Velocity (lens-dependent) | 432 m/s / 798 m/s |
| Data Acquisition Rate | >100,000 bursts/sec |
| ADC Resolution | 16-bit |
| Calibration | NIST-traceable certificate included |
| Connectivity | Wi-Fi enabled |
| Integrated Oscilloscope Functionality | Yes |
| Brand | Dantec Dynamics |
|---|---|
| Origin | Denmark |
| Model | Q-300 |
| Measurement Dimensions | 1D/2D/3D |
| Maximum Field of View | 200 mm × 300 mm |
| Displacement Resolution | 0.03–0.1 µm (adjustable) |
| Strain Range | 0.005%–100% |
| Contactless Operation | Yes |
| Application Domain | Full-field deformation, displacement, strain, and defect detection |
| Brand | Dantec Dynamics |
|---|---|
| Origin | Denmark |
| Model | IDS |
| Measurement Principle | Shadowgraphy (Optical Silhouette Imaging) |
| Particle Size Range | 1–90 µm (volume-equivalent spherical diameter, 0.0005–381 pL) |
| Size Resolution | < 0.1 µm |
| Velocity Range | 0–60 m/s |
| Velocity Components Measured | 2D (in-plane) |
| Max Sampling Frequency | 150 kHz |
| Droplet Sphericity Assessment | Yes |
| Particle Capture Efficiency | ~100% (at optimal setup) |
| Drift Sensitivity | Low (robust to axial spray drift) |
| Real-time Control Output Interface | Yes (analog/digital, compatible with PLC/DCS) |
| Compliance | Designed for industrial GLP/GMP-adjacent environments |
| Brand | Dantec Dynamics |
|---|---|
| Origin | Germany |
| Model | Q-800 |
| Excitation Compatibility | Thermal, Vacuum, Vibration |
| Measurement Principle | Laser Speckle Shearing Interferometry |
| Field of View | Configurable from 10 × 10 cm to 2 m² |
| Acquisition Time | ≤30 s per 2 m² area |
| Compliance | NAS410 / EN4179 certified methodology |
| Target Materials | CFRP, aluminum alloys, honeycomb composites, bonded structures |
| Defect Sensitivity | Delaminations, disbonds, wrinkles, impact damage, core crush, foreign object inclusions, voids, moisture ingress, repair anomalies |
| Brand | Dantec Dynamics |
|---|---|
| Origin | Germany |
| Model | Q-810 |
| Type | Full-Field, Non-Contact Optical Shearography NDT System |
| Compliance | Designed for ASTM E2657, ISO 12718, and EN 13715-compliant shearographic inspection workflows |
| Application Scope | In-situ, large-area structural integrity assessment of composite and metallic components |
| Brand | Dantec Dynamics |
|---|---|
| Origin | Denmark |
| Model | FiberPDA |
| Type | Phase Doppler Anemometer (PDA) |
| Measurement Principle | Phase Doppler Interferometry |
| Velocity Range | –300 to +1000 m/s |
| Particle Diameter Range | 0.5 µm to 10,000 µm |
| Velocity Uncertainty | ±0.1% of reading |
| Size Accuracy | <1% |
| Dynamic Range | 1:50 |
| Optical Configuration | Fiber-coupled dual-beam interferometric setup |
| Signal Processing | Real-time digital pulse processing with adaptive thresholding and burst-mode analysis |
| Brand | Dantec |
|---|---|
| Origin | Denmark |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | ComfortSense |
| Pricing | Upon Request |
| Brand | Dantec Dynamics |
|---|---|
| Origin | Denmark |
| Model | VV |
| Measurement Capability | 3D3C (Three-Dimensional, Three-Component) |
| Velocity Range | 0–300 m/s |
| Measurement Volume | 200 mm × 200 mm × 40 mm |
| Accuracy | ±1% of measured velocity |
| Temporal Resolution | Low-frequency acquisition (configurable via camera framing rate and laser repetition rate) |
| Particle Seeding Density | 0.05–0.07 particles per pixel (PPP) |
| Camera Configuration | 2–4 synchronized high-speed CMOS cameras |
| Illumination | Volumetric light sheet or tomographic LED/laser array |
| Software Platform | DynamicStudio with GPU-accelerated volumetric reconstruction (up to 240 CUDA cores) |
| Brand | Dantec |
|---|---|
| Origin | Germany |
| Model | Q-300 TCT |
| Measurement Dimensions | 1D/2D/3D |
| Measurable Area | 0.7 mm × 1 mm to 40 mm × 50 mm |
| Displacement Resolution | 0.01–0.1 µm (adjustable) |
| Strain Range | 0.005%–100% |
| Heating Capability | Up to 300 °C, 200 W power, ramp rate 30 °C/min |
| Brand | Dantec |
|---|---|
| Origin | Denmark |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | FlowMap |
| Pricing | Upon Request |
| OH Excitation Laser Energy | 22–25 mJ per Pulse |
| ICCD Gating Width | 3 ns |
| Photocathode Quantum Efficiency | ~30% |
| CCD Quantum Efficiency | ~70% |
| Synchronizer Timing Resolution | 250 ps |
| Brand | Dantec Dynamics |
|---|---|
| Origin | Germany |
| Model | Q-450 |
| Measurement Dimensions | 2D & 3D |
| Frame Rate | Up to 20 kHz |
| Measurable Area | 70 mm × 50 mm to 1000 mm × 1000 mm (scalable from mm² to m²) |
| Displacement Accuracy | ±1 µm |
| Strain Accuracy | ±0.005% |
| Contactless Operation | Yes |
| Application Focus | High-frequency vibration, transient deformation, dynamic strain mapping |
| Brand | Dantec Dynamics |
|---|---|
| Origin | Denmark |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | 81X30 |
| Measurement Capability | Planar (2D/3D) |
| Frame Rate | >100 Hz |
| Velocity Range | 0–0.5 m/s |
| Accuracy | ±1% of full scale |
| Measurement Area | 190 mm × 120 mm |
| Illumination Source | High-power pulsed LED array with fiber-coupled lens system |
| Camera | FlowSense USB 2M-165 (2 MP, global shutter, 165 fps @ full resolution) |
| Synchronization | Software-controlled via DynamicStudio v7.x |
| Data Acquisition & Analysis | DynamicStudio PIV software suite |
| Brand | Dantec Dynamics |
|---|---|
| Model | FlawScout |
| Technology | Laser Shearography (Speckle Pattern Shearing Interferometry) |
| Origin | Germany |
| Detection Area per Frame | Up to 0.1 m² |
| Typical Inspection Time | <30 s per measurement |
| Excitation Options | Thermal, Vacuum, or Mechanical Vibration |
| Compliance | Designed for ISO 27958, ASTM E2614, and EN 13794-compliant NDT workflows |
| Software | FlawScout Control & Reporting Suite with Audit Trail and Export Capabilities |