Beijing Xilinzi Technology Development Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSIELINS
OriginBeijing, China
ModelXLZ-1090GXH
Instrument TypeOnline Fixed-Mount Gas Analyzer
Target GasCH₄ (also configurable for CO, CO₂, SO₂, NH₃)
Response Time (T₉₀)≤15 s
Measurement AccuracyBulk range: ≤0.01% v/v
Trace range1 ppm
Measurement Range0–50 ppm (min) to 0–100% v/v (max)
Repeatability≤1% FS
Zero Drift≤±1% FS / 48 h
Span Drift≤±1% FS / 48 h
Linearity Error≤±1% FS
Sample Flow Rate0.5–3 L/min
Operating Temperature0–40 °C
Relative Humidity≤90% RH
Power Supply220 V ±10%, 50 ±0.5 Hz, 150 W
Analog Outputs0–20 mA, 4–20 mA, 0–10 mV, 1–5 V (load ≤600 Ω)
DisplayDigital LCD
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSIELINS
OriginBeijing, China
ModelXLZ-1090
Instrument TypeOnline Gas Analyzer
Detection GasesCO₂ (0–50% vol), CH₄ (0–100% vol), O₂ (0–20% vol), H₂S (0–1000 ppm)
Response Time≤10 s
Accuracy±1% FS
ResolutionCH₄/O₂/CO₂: 0.1% vol
H₂S1 ppm
Warm-up Time45 min
OutputRS232 digital interface, 4–20 mA analog output
Power SupplyAC 220 V or DC 12 V
ComplianceDesigned for continuous emission monitoring and industrial process control per ISO 14644-1 ambient air quality reference practices and ASTM D6785 for biogas composition analysis
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSIELINS
ModelXLZ-1090GXH
Detection PrincipleNon-Dispersive Infrared (NDIR) Absorption
Gas MeasuredNH₃ (ammonia), with multi-gas capability (CO, CO₂, SO₂, CH₄)
Measurement Range0–50 ppm (standard)
Accuracy≤ 0.01% v/v (for high-concentration mode), 1 ppm (for trace-level NH₃)
Response TimeT₉₀ ≤ 15 s
Repeatability≤ 1% FS
Zero Drift≤ ±1% FS / 48 h
Span Drift≤ ±1% FS / 48 h
Linearity Error≤ ±1% FS
Sample Flow Rate0.5–3 L/min
Operating Temperature0–40 °C
Relative Humidity≤ 90% RH (non-condensing)
Power Supply220 V ±10%, 50 ±0.5 Hz, 150 W
Output Signals4–20 mA, 0–20 mA, 0–10 mV, 1–5 V (isolated, load ≤ 600 Ω)
DisplayDigital LCD with real-time concentration readout
Enclosure TypeWall-mounted online analyzer
ComplianceDesigned for continuous ambient and stack emission monitoring per ISO 12039, ASTM D6348, and EN 15267-3 requirements
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSIELINS
ModelXLZ-1090GXH
Detection PrincipleNon-Dispersive Infrared (NDIR) Absorption
Target GasSO₂
Measurement Range0–5000 ppm
Resolution1 ppm
Accuracy±1 ppm
Response Time (T₉₀)≤15 s
Zero Drift≤±1% FS / 48 h
Span Drift≤±1% FS / 48 h
Linearity Error≤±1% FS
Repeatability≤1%
Sample Flow Rate0.5–3 L/min
Operating Temperature0–40 °C
Relative Humidity≤90% RH
Power Supply220 V ±10%, 50 ±0.5 Hz, 150 W
Analog Outputs4–20 mA (600 Ω max load), 0–20 mA, 0–10 mV, 1–5 V
DisplayDigital LCD