BrandSIELINS
ModelXLZ-902
OriginBeijing, China
Instrument TypeFlue Gas CEMS
Measurement ParametersSO₂, NOₓ (as HOx), CO, CO₂
Accuracy≤ ±5% FS
Repeatability≤ 2% RSD
Response Time≤ 200 s
Drift (24 h)≤ ±2% FS
ComplianceDesigned for EPA Method 6C, 7E, 10, and ISO 15848-1 / EN 15267-3 referenced performance criteria
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSIELINS
ModelXLZ-903
OriginBeijing, China
Instrument TypeOnline CEMS
Measured GasesSO₂, NOₓ, CO, CO₂, CH₄, NH₃, O₂ (configurable multi-component)
Measurement Range (min)0–50 ppm
Repeatability±1% FS
Resolution0.1 ppm
Response Time≤25 s
Zero Drift±5% FS / 24 h
Span Drift±1% FS / 24 h
Linearity Error±2% FS
ComplianceDesigned for EN 15267-3, EN 14181, and GB/T 16157–2018 referenced operation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSIELINS
OriginBeijing, China
ModelXLZ-1090GXH
TypeOnline Fixed-Mount Gas Analyzer
Detection PrincipleNon-Dispersive Infrared (NDIR)
Target GasCO (single-component)
Measurement Range0–50 ppm (minimum span)
Repeatability≤1% of full scale
Resolution1 ppm (trace level), ≤0.01% v/v (high-concentration mode)
Response TimeT90 ≤15 s
Zero Drift≤±1% FS / 48 h
Span Drift≤±1% FS / 48 h
Linearity Error≤±1% FS
Sample Flow Rate0.5–3 L/min
Operating Temperature0–40 °C
Relative Humidity≤90% RH (non-condensing)
Power Supply220 V ±10%, 50 ±0.5 Hz, 150 W
Analog Outputs4–20 mA, 0–20 mA, 0–10 mV, 1–5 V (configurable, load-independent up to 600 Ω)
DisplayDigital LCD with real-time concentration readout
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSIELINS
OriginBeijing, China
ModelXLZ-3091GXH
Instrument TypePortable
Detection PrincipleNon-Dispersive Infrared (NDIR)
Measuring Range0–50.0 ppm or 0–200.0 ppm CO
Resolution0.1 ppm
Repeatability≤0.5%
Linearity Error≤±1% F.S.
Zero Drift≤±1% F.S.
Span Drift≤±1% F.S.
Response Time (T90)≤60 s
Power SupplyAC 220 V / Internal Rechargeable Battery
Weight≤3 kg
Dimensions245 × 190 × 85 mm
Data InterfaceRS232
CalibrationField-calibratable with certified CO standard gas
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSIELINS
OriginBeijing, China
ModelXLZ-1090GXH
PrincipleNon-Dispersive Infrared (NDIR) Absorption
TypeOnline Fixed-Mount Gas Analyzer
Response Time (T90)≤15 s
Repeatability≤1% FS
Zero Drift≤±1% FS / 48 h
Span Drift≤±1% FS / 48 h
Linearity Error≤±1% FS
Detection Range0–50 ppm to 0–100% v/v (configurable)
Resolution1 ppm (trace), 0.01% v/v (major)
Sample Flow Rate0.5–3 L/min
Operating Temperature0–40 °C
Relative Humidity≤90% RH
Power Supply220 V ±10%, 50 ±0.5 Hz, 150 W
Output Signals4–20 mA, 0–20 mA, 0–10 mV, 1–5 V (load ≤600 Ω)
DisplayDigital LCD with real-time concentration readout
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSIELINS
OriginBeijing, China
ModelXLZ-1090GXH
Instrument TypeOnline Fixed-Mount Gas Analyzer
Target GasesCO, CO₂, SO₂, CH₄, NH₃ (selectable single-component measurement)
Measurement Range0–50 ppm (minimum span), up to 0–100% v/v (configurable)
Repeatability≤1% of FS
Resolution≤0.01% v/v (for %-level concentrations)
Response Time (T₉₀)≤15 s
Zero Drift≤±1% FS / 7 days
Span Drift≤±1% FS / 7 days
Linearity Error≤±1% FS
Sample Flow Rate0.5–3 L/min
Operating Temperature0–40 °C
Relative Humidity≤90% RH (non-condensing)
Power Supply220 V ±10%, 50 Hz ±0.5 Hz, 150 W
Output SignalsIsolated 4–20 mA (default, load ≤400 Ω) and 1–5 V (default, load ≥250 Ω)
Digital InterfaceRS232 standard
Enclosure19-inch rack-mount (483 × 177 × 350 mm, 3U)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSIELINS
OriginBeijing, China
ModelXLZ-3091GXH
Instrument TypePortable
Detection PrincipleNon-Dispersive Infrared (NDIR)
Measuring Range0–0.5% or 0–1% CO₂ (selectable)
Resolution0.001 ppm
Repeatability≤0.5%
Zero Drift≤±1% F.S.
Span Drift≤±1% F.S.
Linearity Error±2% F.S.
Response Time≤60 s
Power SupplyAC 220 V / Internal Rechargeable Battery
Weight≤3 kg
Dimensions245 × 190 × 85 mm
InterfaceRS232
CalibrationField-calibratable with certified standard gas
FilterIntegrated particulate filter with 6-port valve sampling system
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSIELINS
OriginBeijing, China
ModelXLZ-1090GXH
Instrument TypeOnline Fixed-Mount Gas Analyzer
Target GasCH₄ (also configurable for CO, CO₂, SO₂, NH₃)
Response Time (T₉₀)≤15 s
Measurement AccuracyBulk range: ≤0.01% v/v
Trace range1 ppm
Measurement Range0–50 ppm (min) to 0–100% v/v (max)
Repeatability≤1% FS
Zero Drift≤±1% FS / 48 h
Span Drift≤±1% FS / 48 h
Linearity Error≤±1% FS
Sample Flow Rate0.5–3 L/min
Operating Temperature0–40 °C
Relative Humidity≤90% RH
Power Supply220 V ±10%, 50 ±0.5 Hz, 150 W
Analog Outputs0–20 mA, 4–20 mA, 0–10 mV, 1–5 V (load ≤600 Ω)
DisplayDigital LCD
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSIELINS
ModelXLZ-1090GXH
TypeOnline NDIR Gas Analyzer
Detection PrincipleNon-Dispersive Infrared (NDIR) Absorption
Measurement TargetSingle-component CO
Range0–50 ppm (standard), up to 0–200 ppm (configurable)
Repeatability≤1% FS
Resolution0.1 ppm
Response Time (T90)≤20 s
Zero Drift≤±1% FS / 48 h (high-concentration mode)
Span Drift≤±1% FS / 48 h (high-concentration mode)
Linearity Error≤±2% FS
Output SignalsIsolated 4–20 mA (default), 0–20 mA, 0–5 V, 1–5 V (selectable)
load≤400 Ω (current), ≥250 Ω (voltage)
CommunicationRS232 standard interface
Enclosure19" rack-mount chassis (483 × 267 × 177 mm, 3U)
DisplayBacklit LCD with on-screen menu navigation and real-time status prompts
CalibrationManual/auto zero & span calibration
ComplianceDesigned for continuous emission monitoring (CEM), compatible with EPA Method 10, EN 15267, and ISO 12039 requirements for CO quantification in industrial and environmental applications
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSIELINS
ModelXLZ-1090GXH
OriginBeijing, China
Instrument PrincipleNon-Dispersive Infrared (NDIR) Absorption Spectroscopy
ConfigurationOnline Fixed-Mount Analyzer
Response Time≤20 s
Repeatability≤0.5% FS
Zero Drift±1% FS
Span Drift±1% FS
Linearity Error±1% FS
Measurement RangesCO (0–30 ppm), CO₂ (0–30 ppm), CH₄ (0–300 ppm), SO₂, NH₃ (configurable per gas)
Output SignalsIsolated 4–20 mA (default, load ≤400 Ω) and 1–5 V (default, load ≥250 Ω)
Power Supply(220 ± 22) VAC, (50 ± 0.5) Hz
Power Consumption<100 W
Operating Temperature5–40 °C
Relative Humidity≤80% RH
Enclosure19″ rack-mount chassis (standard depth), IP20-rated
Weight~15 kg
ComplianceDesigned for continuous emission monitoring (CEM), process safety integrity level (SIL)-aware deployment, and GLP/GMP-aligned data handling
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSIELINS
ModelXLZ-1090
TypeOnline NDIR Gas Analyzer
Detection PrincipleNon-Dispersive Infrared (NDIR)
Target GasesCO, CO₂, SO₂, CH₄, NH₃ (single-gas measurement per configuration)
Measurement Range0–50 ppm (min) to 0–100% vol (max, configurable)
Repeatability≤1% of full scale
Resolution0.1 ppm (trace mode) / 0.01% v/v (percent mode)
Response Time (T₉₀)≤15 s
Zero Drift≤±1% FS / 48 h
Span Drift≤±1% FS / 48 h
Linearity Error≤±1% FS
Sample Flow Rate0.5–3 L/min
Operating Temperature0–40 °C
Relative Humidity≤90% RH (non-condensing)
Power Supply220 V ±10%, 50 ±0.5 Hz, 150 W
Analog Outputs0–20 mA, 4–20 mA, 0–10 mV, 1–5 V (load ≤600 Ω, isolated)
DisplayDigital LCD with real-time concentration readout
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSIELINS
OriginBeijing, China
ModelXLZ-3091GXH
Instrument TypePortable
Target GasesCO₂, CO, SO₂, CH₄
Measurement Range (CO₂)0–1000 ppm (extendable to 0–100%)
Repeatability≤ ±1% FS
Resolution0.1 ppm
Response Time15 min
Zero Drift≤ ±2% FS / 4 h
Span Drift≤ ±2% FS / 4 h
Linearity Error≤ ±2% FS
Warm-up Time15 min
Weight1.5 kg
Power SupplyDual-battery with dual charging & low-voltage alarm
DisplayLCD with direct concentration readout
Gas Flow ControlAdjustable
Sampling Pathway6-port valve for zero/measurement switching
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSIELINS
OriginBeijing, China
ModelXLZ-1090GXH
Instrument TypeOnline
Detection PrincipleNon-Dispersive Infrared (NDIR)
Measurement Range0–50 ppm (minimum selectable range)
Repeatability≤1% of full scale
Resolution0.1 ppm
Response Time (T90)≤60 s
Zero Drift≤±1% F.S./48 h (for constant-range mode)
Span Drift≤±1% F.S./48 h (for constant-range mode)
Linearity Error≤±2% F.S.
Output SignalsIsolated 4–20 mA (default), 0–5 V (default)
load impedance≤400 Ω for current, ≥250 Ω for voltage
Communication InterfaceRS232
DisplayBacklit LCD with Chinese menu interface
Enclosure19″ rack-mountable chassis
CalibrationManual and automatic zero/span calibration
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSIELINS
OriginBeijing, China
ModelXLZ-1090
Instrument TypeOnline Gas Analyzer
Detection GasesCO₂ (0–50% vol), CH₄ (0–100% vol), O₂ (0–20% vol), H₂S (0–1000 ppm)
Response Time≤10 s
Accuracy±1% FS
ResolutionCH₄/O₂/CO₂: 0.1% vol
H₂S1 ppm
Warm-up Time45 min
OutputRS232 digital interface, 4–20 mA analog output
Power SupplyAC 220 V or DC 12 V
ComplianceDesigned for continuous emission monitoring and industrial process control per ISO 14644-1 ambient air quality reference practices and ASTM D6785 for biogas composition analysis
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSIELINS
ModelBA4000P
Measurement PrincipleParamagnetic Dumbbell Sensor
Range0–10 / 0–25 / 0–100 vol.% O₂
Accuracy±0.1% O₂
Repeatability±0.05% O₂
Response Time (T₉₀)<10 s
Zero Drift±0.1 vol.% O₂/week
Span Drift±0.1% of full scale/week
Sample Temperature+5 to +45 °C
Sample Pressure10 mbar to 1.5 bar (–5 mbar with internal pump)
Flow Rate~120 mL/min (passive, 10 mbar ΔP) or ~30 L/h (with internal pump)
Dew Point≥5 °C below ambient
Particle Filtration8 µm disposable filter
Zero GasN₂
Span GasAmbient air or certified O₂ standard
Operating Temp.+10 to +45 °C
Storage Temp.–25 to +65 °C
Relative Humidity<75% avg.
Output Signals4–20 mA or 0–1 V selectable
Display3½-digit LCD
Power Supply115/230 VAC, 50/60 Hz
Internal Battery12 V, 2.7 Ah (≥14 h operation)
Enclosure MaterialAnodized aluminum
IP RatingIP20 standard, optional IP54
Weight~4.5 kg
Gas InletPush-fit connection (ID 4 mm / OD 6 mm)
Wetted MaterialsPolyvinylidene fluoride (PVDF), borosilicate glass, 1.4571 stainless steel, gold, Viton®, platinum–iridium alloy, epoxy resin
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSIELINS
ModelXLZ-1090
PrincipleNon-Dispersive Infrared (NDIR) Absorption
ConfigurationOnline Fixed-Mount Analyzer
Response TimeT90 ≤ 15 s
Repeatability≤ 1% FS
StabilityDrift ≤ ±1% FS / 15 days
Linearity Error≤ ±1% FS
Gas Flow Rate0.5–3 L/min
Operating Temperature0–40 °C
Relative Humidity≤ 90% RH
Power Supply220 V ±10%, 50 Hz ±0.5 Hz, 150 W
Simultaneous Measurement ChannelsUp to 4 gases
Measured GasesCO, CO₂, SO₂, CH₄, NH₃ (configurable per application)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSIELINS
ModelXLZ-1090GXH
TypeOnline Gas Analyzer
Detection PrincipleNon-Dispersive Infrared (NDIR)
Measurement TargetSingle-component CH₄
Range0–50 ppm (standard minimum), up to 0–100% vol (configurable)
Repeatability≤1% of full scale
Resolution0.1 ppm
Response Time (T₉₀)≤20 s
Zero Drift≤±1% FS/48 h (high-concentration mode)
Span Drift≤±1% FS/48 h (high-concentration mode)
Linearity Error≤±2% FS
DisplayBacklit LCD with Chinese menu interface
Output SignalsIsolated 4–20 mA (default), 0–20 mA, 0–5 V, 1–5 V (selectable)
load≤400 Ω for current, ≥250 Ω for voltage
CommunicationRS232 standard
Housing19" rack-mount chassis (483 mm W × 177 mm H × 300 mm D)
ComplianceDesigned for continuous emission monitoring (CEM), industrial process control, and ambient air quality applications per ISO 12039, ASTM D6522, and EN 15267-3 guidelines
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSIELINS
OriginBeijing, China
ModelXLZ-940
Price RangeUSD 7,000–14,000 (FOB)
Instrument TypePortable Multi-Gas Flue Gas Analyzer
Accuracy≤ ±5% FS (SO₂, CO, NO, NO₂, CO₂)
Repeatability≤ 1% RSD
Response Time< 3 s (T₉₀)
StabilityLong-term baseline drift < 2% FS/week
Measured GasesO₂, SO₂, CO, NO, NO₂, CO₂ (calculated), flue gas temperature, ambient temperature, differential pressure
Sensor ConfigurationInterchangeable electrochemical sensors (1–3 toxic gases selectable)
Operating Temperature0–50 °C
Battery LifeUp to 8 h continuous operation (rechargeable Li-ion)
Data Storage150 measurement sets with timestamp, location tag (optional), and calculated parameters
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSIELINS
ModelXLZ-1090GXH
TypeOnline NDIR Gas Analyzer
Detection PrincipleNon-Dispersive Infrared Absorption
Measurement TargetSO₂ (Single-Component)
Range0–50 ppm (standard), up to 0–100% vol (configurable)
Repeatability≤1% FS
Resolution0.1 ppm
Response Time (T₉₀)≤20 s
Zero Drift≤±1% FS / 48 h (high-concentration mode)
Span Drift≤±1% FS / 48 h (high-concentration mode)
Linearity Error≤±2% FS
Output SignalsIsolated 4–20 mA (default), 0–5 V (default), RS232 digital interface
Enclosure19″ rack-mount chassis (483 × 290 × 177 mm)
ComplianceDesigned for continuous emission monitoring (CEMS) and industrial process control per ISO 12039, ASTM D6216, and EPA Method 6C requirements
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSIELINS
ModelXLZ-1090GXH
Detection PrincipleNon-Dispersive Infrared (NDIR) Absorption
Gas MeasuredNH₃ (ammonia), with multi-gas capability (CO, CO₂, SO₂, CH₄)
Measurement Range0–50 ppm (standard)
Accuracy≤ 0.01% v/v (for high-concentration mode), 1 ppm (for trace-level NH₃)
Response TimeT₉₀ ≤ 15 s
Repeatability≤ 1% FS
Zero Drift≤ ±1% FS / 48 h
Span Drift≤ ±1% FS / 48 h
Linearity Error≤ ±1% FS
Sample Flow Rate0.5–3 L/min
Operating Temperature0–40 °C
Relative Humidity≤ 90% RH (non-condensing)
Power Supply220 V ±10%, 50 ±0.5 Hz, 150 W
Output Signals4–20 mA, 0–20 mA, 0–10 mV, 1–5 V (isolated, load ≤ 600 Ω)
DisplayDigital LCD with real-time concentration readout
Enclosure TypeWall-mounted online analyzer
ComplianceDesigned for continuous ambient and stack emission monitoring per ISO 12039, ASTM D6348, and EN 15267-3 requirements
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSIELINS
ModelXLZ-1090GXH
TypeOnline Fixed-Mount Gas Analyzer
Measurement PrincipleNDIR (Non-Dispersive Infrared)
Target GasesCH₄, CO₂, O₂, CO, H₂S, SO₂, NH₃
Detection RangeCH₄: 0–100% vol
CO₂0–50% vol
O₂0–20% vol
H₂S0–1000 ppm
Minimum Detectable Range0–50 ppm
ResolutionCH₄/O₂/CO₂: 0.1% vol
H₂S1 ppm
Repeatability≤1% FS
Linearity Error≤±1% FS
Zero Drift≤±1% FS / 48 h
Span Drift≤±1% FS / 48 h
Response Time (T₉₀)≤10 s
Warm-up Time15 min
Output SignalsIsolated 4–20 mA (default), 0–5 V DC, RS232 serial interface
Power SupplyAC 220 V ±10% / 50 Hz or DC 12 V
Enclosure19″ rack-mount (standard industrial chassis)
ComplianceDesigned for continuous emission monitoring (CEMS) and process gas analysis per ISO 14644-1 cleanroom air guidance, ASTM D1945 & D1946 for gas composition, and compatible with GLP/GMP data integrity requirements via optional audit-trail-enabled software
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSIELINS
ModelXLZ-1090GXH
Detection PrincipleNon-Dispersive Infrared (NDIR) Absorption
Target GasSO₂
Measurement Range0–5000 ppm
Resolution1 ppm
Accuracy±1 ppm
Response Time (T₉₀)≤15 s
Zero Drift≤±1% FS / 48 h
Span Drift≤±1% FS / 48 h
Linearity Error≤±1% FS
Repeatability≤1%
Sample Flow Rate0.5–3 L/min
Operating Temperature0–40 °C
Relative Humidity≤90% RH
Power Supply220 V ±10%, 50 ±0.5 Hz, 150 W
Analog Outputs4–20 mA (600 Ω max load), 0–20 mA, 0–10 mV, 1–5 V
DisplayDigital LCD
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSIELINS
OriginBeijing, China
ModelXLZ-802
Instrument TypeContinuous Emission Monitoring System (CEMS)
Measurement Accuracy±2% FS
Repeatability≤2% FS
Response Time≤90 s
Long-term Stability≤2% FS/7 days
Measured GasesCO, CO₂, H₂, O₂
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSIELINS
ModelXLZ-3090GXH
Detection PrincipleNDIR (Non-Dispersive Infrared)
Gas ChannelsCO and CO₂ (simultaneous dual-component measurement)
Measurement Range (CO)0–50.0 ppm or 0–200.0 ppm (user-selectable)
Resolution0.1 ppm
Accuracy (Linearity)≤ ±1% F.S.
Repeatability≤ 0.5% F.S.
Zero Drift≤ ±1% F.S./h
Span Drift≤ ±1% F.S./3 h
Response Time (T₉₀)≤ 30 s
Sampling Flow Rate1.5 L/min
Interference Tolerance≤ ±2% F.S. under 500 mg/m³ CO₂ or saturated water vapor at ambient temperature
Output InterfaceRS232 serial port with PC-compatible software
Data Storage CapacityUp to 5,000 records
Display Unitsppm and mg/m³ (real-time conversion)
Power SupplyAC 220 V ±10% / internal rechargeable battery
Weight≤ 3 kg
Dimensions245 mm × 190 mm × 85 mm
Operating Environment0–40 °C, 20–90% RH (non-condensing)
ComplianceDesigned for field-deployable environmental monitoring per ISO 12039 (CO), ISO 4223 (CO₂), and applicable national ambient air quality standards