BrandSIELINS
ModelXLZ-902
OriginBeijing, China
Instrument TypeFlue Gas CEMS
Measurement ParametersSO₂, NOₓ (as HOx), CO, CO₂
Accuracy≤ ±5% FS
Repeatability≤ 2% RSD
Response Time≤ 200 s
Drift (24 h)≤ ±2% FS
ComplianceDesigned for EPA Method 6C, 7E, 10, and ISO 15848-1 / EN 15267-3 referenced performance criteria
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSIELINS
ModelXLZ-903
OriginBeijing, China
Instrument TypeOnline CEMS
Measured GasesSO₂, NOₓ, CO, CO₂, CH₄, NH₃, O₂ (configurable multi-component)
Measurement Range (min)0–50 ppm
Repeatability±1% FS
Resolution0.1 ppm
Response Time≤25 s
Zero Drift±5% FS / 24 h
Span Drift±1% FS / 24 h
Linearity Error±2% FS
ComplianceDesigned for EN 15267-3, EN 14181, and GB/T 16157–2018 referenced operation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSIELINS
OriginBeijing, China
ModelXLZ-1090GXH
TypeOnline Fixed-Mount Gas Analyzer
Detection PrincipleNon-Dispersive Infrared (NDIR)
Target GasCO (single-component)
Measurement Range0–50 ppm (minimum span)
Repeatability≤1% of full scale
Resolution1 ppm (trace level), ≤0.01% v/v (high-concentration mode)
Response TimeT90 ≤15 s
Zero Drift≤±1% FS / 48 h
Span Drift≤±1% FS / 48 h
Linearity Error≤±1% FS
Sample Flow Rate0.5–3 L/min
Operating Temperature0–40 °C
Relative Humidity≤90% RH (non-condensing)
Power Supply220 V ±10%, 50 ±0.5 Hz, 150 W
Analog Outputs4–20 mA, 0–20 mA, 0–10 mV, 1–5 V (configurable, load-independent up to 600 Ω)
DisplayDigital LCD with real-time concentration readout
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSIELINS
ModelXLZ-800
ApplicationCement Kiln Electrostatic Precipitator & Coal Mill Safety Monitoring
Detection PrincipleNon-Dispersive Infrared (NDIR)
Measurement Range0–1000 ppm CO (configurable)
Accuracy±2% FS
Response Time (T90)<30 s
Output Signals4–20 mA, Relay Alarms (SPDT), Digital Modbus RTU
Environmental Operating Range−10 to +50 °C, ≤90% RH (non-condensing)
Enclosure RatingIP65
ComplianceGB/T 18204.2–2014, ISO 12039, IEC 61508 SIL 2 capable
Power Supply220 VAC ±10%, 50/60 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSIELINS
ModelXLZ-1090A
Detection PrincipleNon-Dispersive Infrared (NDIR)
Gas ChannelsUp to 3 simultaneous analytes (e.g., CO, CO₂, CH₄, SO₂, NO + optional O₂)
Measurement Range (typ.)CO: 0–2000 ppm
CO₂0–1000 ppm
O₂0–1% vol
DisplayColor TFT LCD with capacitive touch interface
Output4–20 mA analog (isolated), 8 relay outputs (SPDT), RS232 (field-upgradable to RS485)
Response Time (T90)≤15 s (IR channels)
Stability±1% FS / 7 days
Repeatability±0.5% FS
Linearity Error±1% FS
Temp. Drift±1% FS (5–45 °C)
Pressure CompensationYes
Enclosure19″ (483 mm) rack-mount chassis
CertificationsNon-explosive (non-ATEX/IECEx)
Operating Ambient5–45 °C
Interference Rejection±1% FS under cross-gas interference
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSIELINS
OriginBeijing, China
ModelXLZ-3091GXH
Instrument TypePortable
Detection PrincipleNon-Dispersive Infrared (NDIR)
Measuring Range0–50.0 ppm or 0–200.0 ppm CO
Resolution0.1 ppm
Repeatability≤0.5%
Linearity Error≤±1% F.S.
Zero Drift≤±1% F.S.
Span Drift≤±1% F.S.
Response Time (T90)≤60 s
Power SupplyAC 220 V / Internal Rechargeable Battery
Weight≤3 kg
Dimensions245 × 190 × 85 mm
Data InterfaceRS232
CalibrationField-calibratable with certified CO standard gas
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSIELINS
OriginBeijing, China
ModelXLZ-1090GXH
Analysis PrincipleNon-Dispersive Infrared (NDIR) Spectroscopy
Gas MeasuredNO (Nitric Oxide), with cross-sensitivity to NO₂ in multi-component gas streams
Measurement Range0–50 ppm (min) to 0–100% v/v (max, configurable)
Detection Limit0.01 ppm for O₂/N₂ (as background reference), 1 ppm for NO (trace mode)
Accuracy≤ 0.01% v/v (major component), ≤ 1 ppm (trace)
Repeatability≤ 1% FS
Zero Drift≤ ±1% FS / 48 h
Span Drift≤ ±1% FS / 48 h
Linearity Error≤ ±1% FS
Response Time (T₉₀)≤ 15 s
Sample Flow Rate0.5–3 L/min
Operating Temperature0–40 °C
Relative Humidity≤ 90% RH (non-condensing)
Power Supply220 V ±10%, 50 ±0.5 Hz, 150 W
Analog Outputs4–20 mA (isolated, ≤400 Ω load) and 1–5 V (isolated, ≥250 Ω load), configurable
Digital InterfaceRS232 (standard), protocol-compatible with SCADA/DCS systems
ComplianceDesigned per IEC 61000-6-2 (EMC immunity) and IEC 61000-6-3 (EMC emission)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSIELINS
OriginBeijing, China
ModelXLZ-1090GXH
PrincipleNon-Dispersive Infrared (NDIR) Absorption
TypeOnline Fixed-Mount Gas Analyzer
Response Time (T90)≤15 s
Repeatability≤1% FS
Zero Drift≤±1% FS / 48 h
Span Drift≤±1% FS / 48 h
Linearity Error≤±1% FS
Detection Range0–50 ppm to 0–100% v/v (configurable)
Resolution1 ppm (trace), 0.01% v/v (major)
Sample Flow Rate0.5–3 L/min
Operating Temperature0–40 °C
Relative Humidity≤90% RH
Power Supply220 V ±10%, 50 ±0.5 Hz, 150 W
Output Signals4–20 mA, 0–20 mA, 0–10 mV, 1–5 V (load ≤600 Ω)
DisplayDigital LCD with real-time concentration readout
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSIELINS
OriginBeijing, China
ModelXLZ-1090GXH
Instrument TypeOnline Fixed-Mount Gas Analyzer
Target GasesCO, CO₂, SO₂, CH₄, NH₃ (selectable single-component measurement)
Measurement Range0–50 ppm (minimum span), up to 0–100% v/v (configurable)
Repeatability≤1% of FS
Resolution≤0.01% v/v (for %-level concentrations)
Response Time (T₉₀)≤15 s
Zero Drift≤±1% FS / 7 days
Span Drift≤±1% FS / 7 days
Linearity Error≤±1% FS
Sample Flow Rate0.5–3 L/min
Operating Temperature0–40 °C
Relative Humidity≤90% RH (non-condensing)
Power Supply220 V ±10%, 50 Hz ±0.5 Hz, 150 W
Output SignalsIsolated 4–20 mA (default, load ≤400 Ω) and 1–5 V (default, load ≥250 Ω)
Digital InterfaceRS232 standard
Enclosure19-inch rack-mount (483 × 177 × 350 mm, 3U)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSIELINS
OriginBeijing, China
ModelXLZ-3091GXH
Instrument TypePortable
Detection PrincipleNon-Dispersive Infrared (NDIR)
Measuring Range0–0.5% or 0–1% CO₂ (selectable)
Resolution0.001 ppm
Repeatability≤0.5%
Zero Drift≤±1% F.S.
Span Drift≤±1% F.S.
Linearity Error±2% F.S.
Response Time≤60 s
Power SupplyAC 220 V / Internal Rechargeable Battery
Weight≤3 kg
Dimensions245 × 190 × 85 mm
InterfaceRS232
CalibrationField-calibratable with certified standard gas
FilterIntegrated particulate filter with 6-port valve sampling system
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSIELINS
OriginBeijing, China
ModelXLZ-900
Output4–20 mA analog signal per gas component
Alarm OutputDry contact (NO/NC) for concentration threshold violation
Communication InterfaceRS-485 (Modbus RTU)
Application DomainMicrobial fermentation off-gas monitoring (O₂, CO₂, exhaust airflow)
Compliance ContextDesigned for integration into GMP-compliant biomanufacturing environments with audit-ready data logging capability
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSIELINS
OriginBeijing, China
ModelXLZ-1090GXH
Instrument TypeOnline Fixed-Mount Gas Analyzer
Target GasCH₄ (also configurable for CO, CO₂, SO₂, NH₃)
Response Time (T₉₀)≤15 s
Measurement AccuracyBulk range: ≤0.01% v/v
Trace range1 ppm
Measurement Range0–50 ppm (min) to 0–100% v/v (max)
Repeatability≤1% FS
Zero Drift≤±1% FS / 48 h
Span Drift≤±1% FS / 48 h
Linearity Error≤±1% FS
Sample Flow Rate0.5–3 L/min
Operating Temperature0–40 °C
Relative Humidity≤90% RH
Power Supply220 V ±10%, 50 ±0.5 Hz, 150 W
Analog Outputs0–20 mA, 4–20 mA, 0–10 mV, 1–5 V (load ≤600 Ω)
DisplayDigital LCD
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSIELINS
ModelXLZ-1090GXH
TypeOnline NDIR Gas Analyzer
Detection PrincipleNon-Dispersive Infrared (NDIR) Absorption
Measurement TargetSingle-component CO
Range0–50 ppm (standard), up to 0–200 ppm (configurable)
Repeatability≤1% FS
Resolution0.1 ppm
Response Time (T90)≤20 s
Zero Drift≤±1% FS / 48 h (high-concentration mode)
Span Drift≤±1% FS / 48 h (high-concentration mode)
Linearity Error≤±2% FS
Output SignalsIsolated 4–20 mA (default), 0–20 mA, 0–5 V, 1–5 V (selectable)
load≤400 Ω (current), ≥250 Ω (voltage)
CommunicationRS232 standard interface
Enclosure19" rack-mount chassis (483 × 267 × 177 mm, 3U)
DisplayBacklit LCD with on-screen menu navigation and real-time status prompts
CalibrationManual/auto zero & span calibration
ComplianceDesigned for continuous emission monitoring (CEM), compatible with EPA Method 10, EN 15267, and ISO 12039 requirements for CO quantification in industrial and environmental applications
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSIELINS
ModelXLZ-1090GXH
OriginBeijing, China
Instrument PrincipleNon-Dispersive Infrared (NDIR) Absorption Spectroscopy
ConfigurationOnline Fixed-Mount Analyzer
Response Time≤20 s
Repeatability≤0.5% FS
Zero Drift±1% FS
Span Drift±1% FS
Linearity Error±1% FS
Measurement RangesCO (0–30 ppm), CO₂ (0–30 ppm), CH₄ (0–300 ppm), SO₂, NH₃ (configurable per gas)
Output SignalsIsolated 4–20 mA (default, load ≤400 Ω) and 1–5 V (default, load ≥250 Ω)
Power Supply(220 ± 22) VAC, (50 ± 0.5) Hz
Power Consumption<100 W
Operating Temperature5–40 °C
Relative Humidity≤80% RH
Enclosure19″ rack-mount chassis (standard depth), IP20-rated
Weight~15 kg
ComplianceDesigned for continuous emission monitoring (CEM), process safety integrity level (SIL)-aware deployment, and GLP/GMP-aligned data handling
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSIELINS
ModelXLZ-1090
TypeOnline NDIR Gas Analyzer
Detection PrincipleNon-Dispersive Infrared (NDIR)
Target GasesCO, CO₂, SO₂, CH₄, NH₃ (single-gas measurement per configuration)
Measurement Range0–50 ppm (min) to 0–100% vol (max, configurable)
Repeatability≤1% of full scale
Resolution0.1 ppm (trace mode) / 0.01% v/v (percent mode)
Response Time (T₉₀)≤15 s
Zero Drift≤±1% FS / 48 h
Span Drift≤±1% FS / 48 h
Linearity Error≤±1% FS
Sample Flow Rate0.5–3 L/min
Operating Temperature0–40 °C
Relative Humidity≤90% RH (non-condensing)
Power Supply220 V ±10%, 50 ±0.5 Hz, 150 W
Analog Outputs0–20 mA, 4–20 mA, 0–10 mV, 1–5 V (load ≤600 Ω, isolated)
DisplayDigital LCD with real-time concentration readout
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSIELINS
OriginBeijing, China
ModelXLZ-3091GXH
Instrument TypePortable
Target GasesCO₂, CO, SO₂, CH₄
Measurement Range (CO₂)0–1000 ppm (extendable to 0–100%)
Repeatability≤ ±1% FS
Resolution0.1 ppm
Response Time15 min
Zero Drift≤ ±2% FS / 4 h
Span Drift≤ ±2% FS / 4 h
Linearity Error≤ ±2% FS
Warm-up Time15 min
Weight1.5 kg
Power SupplyDual-battery with dual charging & low-voltage alarm
DisplayLCD with direct concentration readout
Gas Flow ControlAdjustable
Sampling Pathway6-port valve for zero/measurement switching
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSIELINS
OriginBeijing, China
ModelXLZ-1090GXH
Instrument TypeOnline
Detection PrincipleNon-Dispersive Infrared (NDIR)
Measurement Range0–50 ppm (minimum selectable range)
Repeatability≤1% of full scale
Resolution0.1 ppm
Response Time (T90)≤60 s
Zero Drift≤±1% F.S./48 h (for constant-range mode)
Span Drift≤±1% F.S./48 h (for constant-range mode)
Linearity Error≤±2% F.S.
Output SignalsIsolated 4–20 mA (default), 0–5 V (default)
load impedance≤400 Ω for current, ≥250 Ω for voltage
Communication InterfaceRS232
DisplayBacklit LCD with Chinese menu interface
Enclosure19″ rack-mountable chassis
CalibrationManual and automatic zero/span calibration
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSIELINS
OriginBeijing, China
ModelXLZ-1090
Instrument TypeOnline Gas Analyzer
Detection GasesCO₂ (0–50% vol), CH₄ (0–100% vol), O₂ (0–20% vol), H₂S (0–1000 ppm)
Response Time≤10 s
Accuracy±1% FS
ResolutionCH₄/O₂/CO₂: 0.1% vol
H₂S1 ppm
Warm-up Time45 min
OutputRS232 digital interface, 4–20 mA analog output
Power SupplyAC 220 V or DC 12 V
ComplianceDesigned for continuous emission monitoring and industrial process control per ISO 14644-1 ambient air quality reference practices and ASTM D6785 for biogas composition analysis
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSIELINS
ModelBA4000P
Measurement PrincipleParamagnetic Dumbbell Sensor
Range0–10 / 0–25 / 0–100 vol.% O₂
Accuracy±0.1% O₂
Repeatability±0.05% O₂
Response Time (T₉₀)<10 s
Zero Drift±0.1 vol.% O₂/week
Span Drift±0.1% of full scale/week
Sample Temperature+5 to +45 °C
Sample Pressure10 mbar to 1.5 bar (–5 mbar with internal pump)
Flow Rate~120 mL/min (passive, 10 mbar ΔP) or ~30 L/h (with internal pump)
Dew Point≥5 °C below ambient
Particle Filtration8 µm disposable filter
Zero GasN₂
Span GasAmbient air or certified O₂ standard
Operating Temp.+10 to +45 °C
Storage Temp.–25 to +65 °C
Relative Humidity<75% avg.
Output Signals4–20 mA or 0–1 V selectable
Display3½-digit LCD
Power Supply115/230 VAC, 50/60 Hz
Internal Battery12 V, 2.7 Ah (≥14 h operation)
Enclosure MaterialAnodized aluminum
IP RatingIP20 standard, optional IP54
Weight~4.5 kg
Gas InletPush-fit connection (ID 4 mm / OD 6 mm)
Wetted MaterialsPolyvinylidene fluoride (PVDF), borosilicate glass, 1.4571 stainless steel, gold, Viton®, platinum–iridium alloy, epoxy resin
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSIELINS
ModelXLZ-1090
PrincipleNon-Dispersive Infrared (NDIR) Absorption
ConfigurationOnline Fixed-Mount Analyzer
Response TimeT90 ≤ 15 s
Repeatability≤ 1% FS
StabilityDrift ≤ ±1% FS / 15 days
Linearity Error≤ ±1% FS
Gas Flow Rate0.5–3 L/min
Operating Temperature0–40 °C
Relative Humidity≤ 90% RH
Power Supply220 V ±10%, 50 Hz ±0.5 Hz, 150 W
Simultaneous Measurement ChannelsUp to 4 gases
Measured GasesCO, CO₂, SO₂, CH₄, NH₃ (configurable per application)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSIELINS
ModelXLZ-1090GXH
TypeOnline Gas Analyzer
Detection PrincipleNon-Dispersive Infrared (NDIR)
Measurement TargetSingle-component CH₄
Range0–50 ppm (standard minimum), up to 0–100% vol (configurable)
Repeatability≤1% of full scale
Resolution0.1 ppm
Response Time (T₉₀)≤20 s
Zero Drift≤±1% FS/48 h (high-concentration mode)
Span Drift≤±1% FS/48 h (high-concentration mode)
Linearity Error≤±2% FS
DisplayBacklit LCD with Chinese menu interface
Output SignalsIsolated 4–20 mA (default), 0–20 mA, 0–5 V, 1–5 V (selectable)
load≤400 Ω for current, ≥250 Ω for voltage
CommunicationRS232 standard
Housing19" rack-mount chassis (483 mm W × 177 mm H × 300 mm D)
ComplianceDesigned for continuous emission monitoring (CEM), industrial process control, and ambient air quality applications per ISO 12039, ASTM D6522, and EN 15267-3 guidelines
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSIELINS
OriginBeijing, China
ModelXLZ-940
Price RangeUSD 7,000–14,000 (FOB)
Instrument TypePortable Multi-Gas Flue Gas Analyzer
Accuracy≤ ±5% FS (SO₂, CO, NO, NO₂, CO₂)
Repeatability≤ 1% RSD
Response Time< 3 s (T₉₀)
StabilityLong-term baseline drift < 2% FS/week
Measured GasesO₂, SO₂, CO, NO, NO₂, CO₂ (calculated), flue gas temperature, ambient temperature, differential pressure
Sensor ConfigurationInterchangeable electrochemical sensors (1–3 toxic gases selectable)
Operating Temperature0–50 °C
Battery LifeUp to 8 h continuous operation (rechargeable Li-ion)
Data Storage150 measurement sets with timestamp, location tag (optional), and calculated parameters
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSIELINS
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelXLZ-801
PricingAvailable Upon Request
Measured Components & Detection RangesO₂: 0–1% vol
CO0–100 ppm
CO₂0–100 ppm
H₂configurable ranges — 35–37%, 40–80%, 0–1%, or 90–100% vol
CH₄0–500 ppm
NH₃0–500 ppm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSIELINS
ModelXLZ-1090GXH
TypeOnline NDIR Gas Analyzer
Detection PrincipleNon-Dispersive Infrared Absorption
Measurement TargetSO₂ (Single-Component)
Range0–50 ppm (standard), up to 0–100% vol (configurable)
Repeatability≤1% FS
Resolution0.1 ppm
Response Time (T₉₀)≤20 s
Zero Drift≤±1% FS / 48 h (high-concentration mode)
Span Drift≤±1% FS / 48 h (high-concentration mode)
Linearity Error≤±2% FS
Output SignalsIsolated 4–20 mA (default), 0–5 V (default), RS232 digital interface
Enclosure19″ rack-mount chassis (483 × 290 × 177 mm)
ComplianceDesigned for continuous emission monitoring (CEMS) and industrial process control per ISO 12039, ASTM D6216, and EPA Method 6C requirements
Show next