Empowering Scientific Discovery

Beijing Xilinzi Technology Development Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSIELINS
ModelXLZ-800
ApplicationCement Kiln Electrostatic Precipitator & Coal Mill Safety Monitoring
Detection PrincipleNon-Dispersive Infrared (NDIR)
Measurement Range0–1000 ppm CO (configurable)
Accuracy±2% FS
Response Time (T90)<30 s
Output Signals4–20 mA, Relay Alarms (SPDT), Digital Modbus RTU
Environmental Operating Range−10 to +50 °C, ≤90% RH (non-condensing)
Enclosure RatingIP65
ComplianceGB/T 18204.2–2014, ISO 12039, IEC 61508 SIL 2 capable
Power Supply220 VAC ±10%, 50/60 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSIELINS
ModelXLZ-1090A
Detection PrincipleNon-Dispersive Infrared (NDIR)
Gas ChannelsUp to 3 simultaneous analytes (e.g., CO, CO₂, CH₄, SO₂, NO + optional O₂)
Measurement Range (typ.)CO: 0–2000 ppm
CO₂0–1000 ppm
O₂0–1% vol
DisplayColor TFT LCD with capacitive touch interface
Output4–20 mA analog (isolated), 8 relay outputs (SPDT), RS232 (field-upgradable to RS485)
Response Time (T90)≤15 s (IR channels)
Stability±1% FS / 7 days
Repeatability±0.5% FS
Linearity Error±1% FS
Temp. Drift±1% FS (5–45 °C)
Pressure CompensationYes
Enclosure19″ (483 mm) rack-mount chassis
CertificationsNon-explosive (non-ATEX/IECEx)
Operating Ambient5–45 °C
Interference Rejection±1% FS under cross-gas interference
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSIELINS
OriginBeijing, China
ModelXLZ-900
Output4–20 mA analog signal per gas component
Alarm OutputDry contact (NO/NC) for concentration threshold violation
Communication InterfaceRS-485 (Modbus RTU)
Application DomainMicrobial fermentation off-gas monitoring (O₂, CO₂, exhaust airflow)
Compliance ContextDesigned for integration into GMP-compliant biomanufacturing environments with audit-ready data logging capability
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSIELINS
OriginBeijing, China
ModelSIELINS-904
Power SupplyAC 220 V ±10%, 50 Hz ±1%
Total Power Consumption2000 VA
Probe Power800 VA
�热管线供电: 1500 VA
Compressed Air Requirement0.6 MPa, oil-free & dry
Ambient Temperature Range−10–50 °C
Relative Humidity<80% RH
Output SignalIsolated 4–20 mA DC
Alarm OutputDry contact (NO/NC configurable)
Sample GasWet, dusty process gas containing CO
Primary AnalyteCarbon Monoxide (CO)
ComplianceDesigned for industrial process monitoring per IEC 61511 functional safety principles (non-SIL certified), compatible with DCS/PLC integration under ISO 50001 energy management contexts
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0