| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TGIC Analysis Service |
| Pricing | Available Upon Request |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Model | Microstructural Differentiation Analyzer for Polyolefin Films and Fish-Eye Defects |
| Application Domain | Polyolefin Film Quality Control & Defect Root-Cause Analysis |
| Compliance Framework | ASTM D1238, ISO 1133, ISO 1628-1, ISO 15270, USP <1058> Analytical Instrument Qualification |
| Brand | LEMIS / LEMIS Baltic |
|---|---|
| Model | DM-230.2A |
| Density Range | 0.6500–1.1000 g/cm³ |
| Density Accuracy | ±0.0005 g/cm³ (typical, per ISO 12185) |
| Operating Temperature Range | −40 to +85 °C |
| Submersion Depth | Up to 30 m |
| Data Storage Capacity | 998 measurements |
| Wireless Interface | Integrated Bluetooth® 4.2 for PC and portable printer connectivity |
| Calibration Compliance | Traceable to NIST and PTB standards |
| Hazardous Area Certification | ATEX II 2G Ex ib IIB T4 Gb / IECEx Ex ib IIB T4 Gb |
| Regulatory Listing | Registered in the State Register of Measuring Instruments (Eurasian Economic Union) |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Supplier Type | Authorized Distributor |
| Import Status | Imported |
| Model Compatibility | GPC-IR5, IR4, TREF, CRYSTAF, and Related Polyolefin Analyzers |
| Lead Time | Up to 4 weeks (standard stock available for high-turnover items) |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | GPC-IR5 |
| Pricing | Available Upon Request |
| Brand | IRELAND |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 180700 |
| Pricing | Upon Request |
| Material | ASTM A351 CF3M (304L) Body & Bonnet |
| End Connections | Butt-Weld (BW) Standard |
| Seat | Integral Seat with Reusable Soft Seal |
| Leakage Class | ISO 5208 Class A (Bubble-Tight) |
| Packing Box | Cryo-Optimized, Direct-Through Configuration |
| Temperature Range | −220 °C to +200 °C |
| Pressure Rating | PN16 to PN100 |
| Nominal Size Range | DN15 to DN200 |
| Compliance | EN 1515-1, EN 10222-4, PED 2014/68/EU, ISO 15848-1 (Low Emission) |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Model | IVA |
| Dissolution Temperature Range | Up to 200 °C |
| Sample Capacity | 42 positions |
| Capillary System | Dual stainless-steel capillary viscometer |
| Optional Detector | IR4 infrared detector for C–H bond quantification |
| Solvent Handling | Fully automated solvent addition, dissolution, and system cleaning |
| Compliance Framework | Designed for GLP-compliant laboratories |
| Brand | Masterflex Ismatec |
|---|---|
| Model Numbers | 1300-3100, 1300-3140, 1300-3600, 1300-3642, 1302-3600, 1302-3600-0001 |
| Drive Type | Brushless DC Motor with Digital Speed Control |
| Input Voltage | 100–240 VAC, 50/60 Hz |
| Speed Range | 0.1–600 rpm (adjustable in 0.1 rpm increments) |
| Speed Accuracy | ±0.2% of set speed |
| Torque Output | Up to 1.2 N·m (model-dependent) |
| Remote I/O Interface | Open-collector outputs (non-isolated, max 28 VDC, current-limited via external resistor) |
| Relay Output Option | 24 VDC, ≤150 mA total supply from rear-panel interface connector |
| Compliance | CE, RoHS, UL Recognized (Component Recognition per UL 61010-1) |
| Enclosure Rating | IP20 |
| Operating Temperature | 5–40 °C |
| Humidity | 20–80% RH, non-condensing |
| Dimensions (W×H×D) | 220 × 120 × 240 mm (varies slightly by model) |
| Weight | 3.2–3.8 kg |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Model | CEF |
| Type | Polyolefin Characterization Analyzer |
| Automation Level | Fully Automated |
| Analysis Time per Sample | ≤25 min |
| Sample Capacity | 42-position autosampler |
| Detection Options | IR4 or IR5 FTIR concentration detectors |
| Optional Detectors | Viscometer, Multi-Angle Light Scattering (MALS) |
| Temperature Range | –20 °C to 160 °C (with low-temp and high-temp accessories) |
| Compliance | Designed for GLP/GMP environments |
| Software | CEF Control & Analysis Suite (21 CFR Part 11 compliant audit trail optional) |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Model | CRYSTAF-TREF |
| Technique | Dual-Mode (Crystallization Analysis Fractionation & Temperature Rising Elution Fractionation) |
| Sample Capacity | 5 samples per run |
| Analysis Time | ≤6 h/sample (TREF mode), ≤8 h for 5 samples (CRYSTAF mode) |
| Minimum Operating Temperature | −20 °C |
| Detector Options | IR4 Fourier-transform infrared detector, Differential Viscometer, Multi-Angle Light Scattering (MALS) |
| Automation Level | Fully automated solvent handling, fraction collection, and system cleaning |
| Software Compliance | Audit-trail enabled, user access control, 21 CFR Part 11–ready configuration available |
| Regulatory Alignment | Designed to support ASTM D7943, ISO 16152, and ISO 16014–4 workflows |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | EFS |
| Pricing | Available Upon Request |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Model | GPC-IR Advanced |
| Application | Simultaneous Quantification of Xylene Solubles, Ethylene Content, and Intrinsic Viscosity in Impact Polypropylene |
| Brand | IRELAND |
|---|---|
| Origin | France |
| Model | 160700 |
| Body Material | 304L Stainless Steel (standard), optional 316L |
| Connection | Butt-Weld (standard), optional Flanged |
| Design Temperature Range | −220 °C to +200 °C |
| Size Range | DN8–DN50 |
| Pressure Rating | PN10–PN100 |
| Bonnet Type | Extended Bolted Bonnet |
| Seat Integration | Integral Seat with Reusable Soft Seal Disc |
| Fire-Safe Design | Compliant with ISO 10497 |
| External Surface | Copper-Free Construction |
| Stem & Bonnet Extension | Cryogenic-Optimized Stainless Steel |
| Packing | Enhanced Graphite-Based Packing with Reinforced Gland Assembly |
| Actuation Options | Pneumatic or Electric Actuator (FO/FC), Manual Handwheel with Locking Device |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | CFC Instrument for Polymerization Process Optimization Analysis |
| Pricing | Available Upon Request |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | CRYSTEX |
| Pricing | Available Upon Request |
| Brand | IRELAND |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 160100 |
| Pricing | Available Upon Request |
| Material | CuSn Bronze Body |
| Operating Temperature | −200 °C to +120 °C |
| Size Range | DN8–DN50 |
| Pressure Rating | PN10–PN40 |
| End Connections | Threaded (Standard), Socket Weld / Flanged / Butt Weld (Optional) |
| Seal Type | Reusable Soft Seat with Bubble-Tight Shutoff Verified per ISO 5208 |
| Cryogenic Stem Extension | Stainless Steel Extended Bonnet & Stem |
| Compliance | Designed for ASME B16.34, EN 1515-1, ISO 5208, and PED 2014/68/EU |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Model | CRYSTAF |
| Sample Capacity | 5 samples per run |
| Cycle Time | ~6 hours |
| Minimum Operating Temperature | −20 °C |
| Detection | IR4 Infrared Detector |
| Configuration | Benchtop, Fully Automated |
| Solvent Handling | Closed-loop, Minimal Consumption |
| Software Interface | Intuitive GUI with Remote Monitoring & Diagnostics |
| Upgrade Path | Compatible with CRYSTAF-TREF dual-technique configuration |
| Compliance | Designed to support GLP/GMP workflows and ASTM D7283 (Standard Test Method for Determination of Comonomer Content in Polyolefins by Crystallization Analysis) |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Model | C20 |
| Fractionation Capacity | 10–20 g per run |
| Operating Modes | TREF (Temperature Rising Elution Fractionation) and Molar Mass Fractionation |
| Cycle Time | ≤48 h including dissolution |
| Fraction Collection | Up to 9 fractions per run |
| Detection | Integrated IR detector for real-time fraction monitoring |
| Control | Remote operation and interactive diagnostics enabled |
| Compliance | Designed for GLP-compliant laboratories |
| Software | Fully automated method sequencing with audit trail capability |
| Brand | IRELAND |
|---|---|
| Origin | France |
| Model | 190700 |
| Body Material | 304L Stainless Steel |
| End Connection | Butt-Weld (BW) |
| Seat Design | Integral Seat with Reusable Soft Seal Disc |
| Temperature Range | –220 °C to +200 °C |
| Pressure Rating | PN16 to PN100 |
| Nominal Size | DN15 to DN200 |
| Cryogenic Extension | Extended Bonnet with Bolted Construction |
| Vacuum Jacket Compatibility | Disc-Integrated Welding Pad on Upper Stem |
| Compliance | Designed for ASME B16.34, EN 1515-1, ISO 15848-1 (fugitive emissions), and applicable cryogenic service standards |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Model | PREP C20 |
| Application | Automated Temperature Rising Elution Fractionation (TREF) and Crystallization Analysis Fractionation (CRYSTAF) of Polyolefins |
| Throughput | 10–20 g per run |
| Fraction Number | Up to 9 discrete fractions |
| Cycle Time | ~60 hours per full fractionation sequence |
| Compliance | Designed for ASTM D6964 (TREF), ASTM D7282 (CRYSTAF), ISO 16152, ISO 16014-3 |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CFC Microstructural Differentiation Analyzer |
| Pricing | Available Upon Request |
| Brand | IRELAND |
|---|---|
| Origin | France |
| Model | 170300 |
| Material | ASTM B209 Grade 5083 Aluminum Alloy |
| Connection Type | Butt-Weld (Body), External Thread + Yoke (Bonnet) |
| Operating Temperature Range | −220 °C to +200 °C |
| Pressure Rating | PN10 to PN50 |
| Nominal Diameter | DN10 to DN400 |
| Seal Type | Reusable Metal Seat + Soft Seal Disc |
| Bonnet Extension | Bolted, Extended Design |
| Packing Box | Cryogenically Optimized, Straight-Through Configuration |
| Compliance | Suitable for ASME B16.34, ISO 2852, and EN 1515-2 (Low-Temperature Service) |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Model | HT-GPC System for Molecular Weight, Long-Chain Branching (LCB), and Short-Chain Branching (SCB) Distribution Analysis |
| Detection Modes | Infrared (IR5), Differential Viscometry, Composition-Sensitive Detection |
| Temperature Range | Up to 160 °C |
| Solvent Compatibility | 1,2,4-Trichlorobenzene (TCB), ODCB |
| Calibration Standards | Narrow-MWD PE/PP Reference Standards |
| Data Output | Mw, Mn, Mz, Đ, LCB frequency (λ), SCB density (branches/1000C), Branch Length Distribution, Compositional Heterogeneity Index (CHI) |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SFD |
| Pricing | Available Upon Request |