Agilent Technologies
Filter
Showing 121–150 of 355 results
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Agilent 6890N (Refurbished) |
| Price Range | USD 4,200 – 11,200 |
| Detector | FID (Detection Limit: <5 pg C/s on propane) |
| Oven Temperature Range | Ambient +4 °C to 450 °C |
| Split/Splitless Injector Pressure Range | 0–100 psi (optional 0–150 psi) |
| Total Flow Range (Split/Splitless) | 0–200 mL/min N₂, 0–1000 mL/min H₂ or He |
| Autosampler | Integrated Agilent 7683 Control |
| GC Speed | Up to 10× faster than conventional GC |
| Compliance | Designed for ASTM D3606, D5186, ISO 6416, USP <621>, FDA 21 CFR Part 11-ready configurations available |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Instrument Type | Triple Quadrupole GC-MS |
| Configuration | Standalone Mass Spectrometer (requires compatible Agilent GC, e.g., 7890B/7820A) |
| Detection Principle | Electron Ionization (EI) and Chemical Ionization (CI) |
| Mass Range | 10–1000 m/z |
| Scan Speed | Up to 20,000 Da/sec in MRM mode |
| Sensitivity | <10 fg OFN (octafluoronaphthalene) in EI MRM mode |
| Mass Resolution | Unit mass resolution (0.7 Da at peak apex) |
| Vacuum System | Dual-stage turbomolecular pump (≥260 L/s for MS region) |
| Interface Temperature | Up to 350 °C |
| Data System Compatibility | Agilent MassHunter Workstation (vB.08.00 or later) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | 7000E GC/MS |
| Instrument Type | Triple Quadrupole Mass Spectrometer |
| Chromatography Type | Conventional GC/MS |
| Mass Range | m/z 10–1050 |
| Sensitivity | Inert Plus EI Ion Source – IDL ≤ 4 fg (10 fg OFN injection) |
| Scan Speed | ≤ 20,000 Da/s |
| Detector | Agilent Triple-Axis HED-EM with Extended-Life Electron Multiplier and Dynamically Ramped Iris |
| Brand | Agilent Technologies |
|---|---|
| Origin | Imported |
| Manufacturer Status | Original Equipment Manufacturer (OEM) |
| Instrument Type | Triple Quadrupole Mass Spectrometer |
| GC Configuration | Conventional GC-MS/MS |
| Mass Range | m/z 10–1050 |
| Sensitivity | IDL ≤ 0.3 fg for 1 fg OFN injection |
| Scan Speed | ≤ 20,000 Da/s |
| Detector | Agilent triple-axis high-efficiency dynamic electron multiplier (HED-EM) with extended-life EM and dynamically ramped iris aperture |
| Brand | Agilent Technologies |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Instrument Type | Online Dissolution Tester |
| Vessel Capacity | 8-position |
| Temperature Range | Ambient +5 °C to 55 °C |
| Temperature Accuracy | ±0.1 °C |
| Rotation Speed Range | 10–250 rpm |
| Bath Volume | 18 L |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 7100 |
| Instrument Category | Capillary Electrochromatography (CEC) |
| Sample Analysis Scope | Organic Compounds |
| Brand | Agilent Technologies |
|---|---|
| Origin | Imported |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Quadrupole-Time-of-Flight (Q-TOF) |
| GC Configuration | Conventional GC/MS |
| Mass Range | m/z 20–3000 |
| Resolution | >25,000 FWHM at m/z 271.9867, acquisition-rate independent |
| Sensitivity | IDL <60 fg for 100 fg OFN injection |
| Detector | Microchannel plate/scintillator/PMT with ADC electronics |
| Mass Accuracy | <2 ppm (1 pg OFN, m/z 271.9867) |
| Quadrupole Mass Range | m/z 20–1050 |
| Acquisition Rate | 1–50 spectra/sec, resolution-independent |
| Software Platform | Agilent MassHunter |
| GC Compatibility | Fully compatible with Agilent 8890/8860 GC systems and ZOEX thermal modulator for comprehensive 2D-GC (GC×GC) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | 7650A |
| Instrument Type | Gas Chromatography Autosampler |
| Maximum Sample Capacity | 50 vials |
| Syringe Options | 250 µL and 500 µL |
| Injection Modes | Single and Multi-injection |
| Priority Sample Insertion | Supported |
| Sample Overlap Capability | Yes |
| Needle Alignment | Fully Automated |
| Needle Illumination | Integrated LED lighting for visual verification and method development |
| Injection Technique | Fast, low-discrimination liquid-phase injection optimized for external standard calibration |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | 7693A |
| Instrument Type | Gas Chromatography Autosampler |
| Pricing | Upon Request |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | 7696A |
| Pricing | Upon Request |
| Instrument Type | Gas Chromatography (GC) Autosampler-Integrated Offline Sample Preparation System |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | 7697A |
| Instrument Type | Gas Chromatography Headspace Sampler |
| Maximum Sample Capacity | 12 vials (standard configuration) |
| Sample Vial Sizes Supported | 10 mL, 20 mL, 22 mL |
| Temperature Control Range (Transfer Line) | 35–250 °C (off to 250 °C) |
| Temperature Control Range (Valve & Loop) | 35–210 °C (off to 210 °C) |
| Temperature Control Range (Oven/Chamber) | 35–210 °C (off to 210 °C) |
| Pressure Control | Electronic Pressure Control (EPC) for valve and loop |
| Leak Detection | Automated vial leak check during pressurization |
| Operating Modes | Single Extraction, Multiple Headspace Extraction (MHE), Multiple Headspace Concentration (MHC) |
| MHE/MHC Cycles | Up to 100 cycles per vial |
| Method Development Support | Cross-platform method conversion and rapid re-optimization |
| Software Compatibility | Agilent OpenLab CDS, Agilent MassHunter, Waters Empower™ 2/3 |
| Barcode Reader | Integrated for sample tracking |
| Carrier Gas Options | Helium, Nitrogen, Hydrogen (H₂-safe design) |
| Peak Area Reproducibility | <1.5% RSD (standard mode) |
| Interfacing | Direct GC inlet coupling via transfer line interface |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Agilent 7697A |
| Sample Vial Capacity (Standard) | 111 positions, including 3 priority vial slots |
| Sample Vial Capacity (Optional) | 12-position configuration for academic or low-throughput labs |
| Vial Sizes Supported | 10 mL, 20 mL, and 22 mL vials without adapters |
| Injection Valve Loop Volume | Not specified in source data |
| Carrier Gas Compatibility | Hydrogen (H₂), Helium (He), Nitrogen (N₂) |
| Leak Detection | Automated, real-time vial pressure integrity check prior to analysis |
| Pressure Control | Independent headspace vial pressure and column head pressure regulation |
| Barcoding | Integrated sample vial barcode reader with LIMS-compatible data transmission |
| Method Transfer | Cross-platform method conversion and rapid re-optimization via Agilent Method Translation Software |
| Multi-HeadSpace Modes | Multiple Headspace Extraction (MHE) up to 100 cycles per vial |
| Vial Depressurization | Automatic post-analysis vial depressurization before return to tray |
| Interface | GC inlet-compatible transfer line kit for co-location with Agilent 7693A ALS on same GC inlet |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 7697A |
| Sample Capacity | Up to 111 vials (auto-sampler mode) |
| Vial Sizes Supported | 10 mL, 20 mL, 22 mL |
| Oven Temperature Range | Ambient to 200 °C |
| Transfer Line & Valve Temperature Range | Ambient to 200 °C |
| Injection Mode | Six-port valve with fixed-volume loop |
| Carrier Gas Control | Electronic Pressure Control (EPC) for He, N₂, H₂ |
| Software Compatibility | Agilent OpenLAB CDS and ChemStation |
| Compliance | Designed for GLP/GMP environments |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | 7820A |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Scope | General-purpose Analytical Chemistry |
| Detector Options | FID, TCD, FPD Plus, NPD, µECD |
| Injector Types | Split/Splitless, Packed Column, Purge-and-Trap, Headspace |
| Valve Configuration | Up to 3 Valves |
| Control Architecture | Full Electronic Pressure Control (EPC) from Injector to Detector |
| Software Interface | Compatible with OpenLab CDS and Third-party Data Systems |
| Regulatory Alignment | Designed for GLP/GMP environments |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | 7820A VL |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-purpose analysis |
| Control System | Electronic Pressure Control (EPC) at inlet |
| Detector Regulation | Electronic Pressure Regulation (EPR) for FID |
| Included Configuration Options | SSL/EPC inlet + FID/EPR detector |
| Software | OpenLab CDS VL |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 7850 |
| Instrument Type | Quadrupole Mass Spectrometer |
| Application Environment | Laboratory |
| Mass Range (amu) | 2–260 |
| Resolution (Unit Mass Resolution, amu) | 0.2–1 (adjustable) |
| Detection Limit (ng·L⁻¹) | ≤5×10⁻⁷ for low-mass elements, ≤1×10⁻⁷ for high-mass elements |
| Sensitivity (Mcps / mg·L⁻¹) | Li ≥ 80, Y ≥ 240, U ≥ 300 |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 7850 |
| Instrument Type | Quadrupole ICP-MS |
| Application Environment | Laboratory |
| Mass Range (amu) | 5–260 |
| Unit Mass Resolution (amu) | 0.5 |
| Detection Limit (ng·L⁻¹) | 10 |
| Sensitivity (Mcps / mg·L⁻¹) | 10 |
| Short-Term Stability (RSD %) | 3 |
| Long-Term Stability (RSD %) | 5 |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | Agilent 7890A |
| Operational Age | 4–5 years |
| Configuration | Standard GC system with integrated 7683 autosampler control |
| Regulatory Readiness | Built-in 21 CFR Part 11 compliance features (audit trail, electronic signature support, user access levels) |
| Detection Options | FID, TCD, µECD, NPD, MSD, ICP-MS, and optional PFPD, SCD, AED via Agilent partner ecosystem |
| Injection Modes | Split/splitless (0–100 psi & 0–150 psi), packed column, on-column, PTV, and volatile analysis interface |
| Data Systems | Compatible with Agilent ChemStation Plus (ChemStore C/S, ChemAccess), PetroQA/QC Cerity NDS |
| Speed Capability | Fast GC mode (up to 10× faster than conventional GC) |
| Sample Introduction | Supports headspace, purge-and-trap, valve injection, and large-volume injection (LVI) without pre-concentration |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | Agilent 7890A |
| Instrument Age | 4–5 years |
| Configuration | Includes integrated Agilent 7683 autosampler control |
| Detector Options | FID, TCD, µECD, NPD, MSD, ICP-MS, FPD (upgraded), plus optional SCD, PFPD, AED via Agilent Partners |
| Inlet Types | Split/splitless (0–100 psi & 0–150 psi), packed column, on-column, PTV, VOA |
| Software Compatibility | Agilent ChemStation Plus (ChemStore C/S, ChemAccess), Cerity QA/QC for Petrochemicals |
| Regulatory Compliance | Supports 21 CFR Part 11 audit trails, GLP/GMP data integrity requirements |
| GC Speed | Capable of fast GC operation (up to 10× faster than conventional GC) |
| Sample Introduction | Large-volume injection (LVI) enabled, headspace, purge-and-trap, valve-based injection modules available |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | 7890B |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Petrochemical Industry |
| Heating/Cooling Rate | Enabled by Low Thermal Mass (LTM) modules for direct, rapid column heating and cooling |
| Compliance | Designed to support GLP/GMP workflows with audit-trail-capable data systems (when paired with OpenLab CDS or ChemStation software) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | Agilent 7890B + 5977B |
| Configuration | Gas Chromatography–Mass Spectrometry (GC-MS) System |
| Vacuum System | High-Performance Turbomolecular Pump |
| Ion Source | Dual-Filament EI Source, Inert (Non-Coated, Non-Stainless Steel) |
| Mass Analyzer | Gold-Plated Quartz Quadrupole with Turner-Kruge Lenses |
| Mass Range | 1.6–1050 u (0.1 u increments) |
| Resolution | Unit Mass Resolution |
| Mass Stability | ≤0.10 u / 48 h |
| Full-Scan Sensitivity (EI) | ≥400:1 S/N for 1 pg OFN (m/z 272, 50–300 u scan) |
| SIM Sensitivity (EI) | ≥10:1 S/N for 20 fg OFN |
| Max Scan Rate | 12,500 u/s (1 ms dwell in SIM) |
| Dynamic Range | 10⁶ |
| SIM Capacity | 100 groups, up to 60 ions/group |
| GC Oven Temp Range | 4 °C above ambient to 450 °C |
| Max Ramp Rate | 120 °C/min |
| Temperature Stability | <0.01 °C per 1 °C ambient change |
| Programmable Temperature Zones | ≥6 heated zones (including inlet, detector, transfer line), all independently controlled up to 400 °C |
| EPC Pressure Control Accuracy | ±0.001 psi |
| Split/Splitless Inlet | Up to 7500:1 split ratio, 0–1250 mL/min H₂/He flow range |
| Auto-sampler | 16-position (standard), optional 150-position tray |
| Detectors Included | FID (detection limit <1.8 pg C/s), micro-ECD (<6 fg/mL lindane), NPD (<0.4 pg N/s, <0.2 pg P/s) |
| Compliance | Fully compatible with EPA Methods (e.g., 502.2, 524.4, 8260, 8270), USP <621>, ASTM D5845, and GLP/GMP data integrity requirements per FDA 21 CFR Part 11 |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 7900 |
| Instrument Type | Quadrupole Mass Spectrometer |
| Application Environment | Laboratory |
| Detection Principle | Inductively Coupled Plasma Ionization with Quadrupole Mass Filtering |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic Instrument |
| Model | 8255 NCD |
| Pricing | Available Upon Request |
| Compatible Instrument | Gas Chromatograph (GC) |
| Detector Type | Selective Nitrogen-Specific Detector |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | 8355 SCD |
| Pricing | Available Upon Request |
| Compatible Instrument | Gas Chromatograph (GC) |
| Detector Type | Elemental-Specific Chromatographic Detector |
| Brand | Agilent Technologies |
|---|---|
| Origin | Imported |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Online Sampling System |
| Model | 850-DS |
| Compliance | Compatible with USP <711>, <724>, and ASTM D8239-22 |
| Pump Architecture | Integrated Rotary Piston Pump |
| Filtration | Optional 8-channel Whatman/Cytiva filter plate module |
| Sample Interface | Direct-to-HPLC vial tray (Agilent 1260/1290-compatible format) |
| Method Support | USP Apparatus 1 (Basket), 2 (Paddle), 3 (Reciprocating Cylinder), 5 (Paddle-over-Disk), 6 (Rotating Cylinder), and 7 (Reciprocating Holder) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | 8697 |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Valve Temperature Control Range | Ambient + 5 °C to 300 °C |
| Sample Vial Capacity | 48 positions |
| Compatible Vial Sizes | 10 mL, 20 mL, 22 mL |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | 8697 |
| Pricing | Available upon request |
| Temperature Control Precision | Optional cooling plate enables sample stabilization at 4 °C |
| Vial Sizes Supported | 10 mL, 20 mL, 22 mL |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 8860 |
| Configuration | Dual Inlet, Triple Detector Capable (including Single Quadrupole MS-ready), Full Electronic Pressure Control (EPC), Touchscreen Interface, OpenLab CDS Compatible |
| Compliance | Designed to support GLP/GMP workflows, 21 CFR Part 11–ready with audit trail enabled in OpenLab CDS |
| Software | Agilent OpenLab CDS (v2.4+), DA Express (optional), RTL-enabled methods |
| Environmental Compensation | Yes (temperature & barometric pressure) |
| Diagnostic Capability | Built-in GC Health Check, Baseline Anomaly Detection, Detector Performance Assessment, Method Transfer Validation Support |
| Rental Options | Short-term lease (≥1 month), Lease-to-own, Capital lease with title transfer |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Regional Classification | Domestic (China) |
| Model | 8860 GC |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Temperature Control Range | +8 °C above ambient to 425 °C |
| Maximum Ramp Rate | 75 °C/min |
| Cooling Rate | 300 °C to 50 °C in 5.7 min (at 25 °C ambient) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | 8890 GC |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-purpose |
| Oven Temperature Range | +4 °C above ambient to 450 °C |
| Maximum Ramp Rate | 120 °C/min (75 °C/min with 120 V power supply) |
| Oven Cool-down | 4.0 min from 450 °C to 50 °C (ambient 22 °C) |
| Detector Options | FID, TCD, SCD, NCD, compatible with single-quadrupole, triple-quadrupole, and Q-TOF GC/MS platforms |
| Retention Time Reproducibility | <0.008% RSD |
| Peak Area Reproducibility | <0.5% RSD |
| Pressure Control Resolution | 0.001 psi |
| Dual-Tower Simultaneous Injection | Yes |
| Dimensions (W × D × H) | 58 cm × 51 cm × 49 cm |
| Microfluidic Flow Control Technology (CFT) | Fully integrated |
| Cryogenic Cooling Options | –80 °C (LN₂), –40 °C (CO₂) |
| Inlet Configurations | Up to 2 inlets + 10 valves |
| Environmental Certification | My Green Lab ACT Label (Accountability, Consistency, Transparency) |