Agilent Technologies
Filter
Showing 301–330 of 567 results
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | Agilent 7890B + 5977B |
| Configuration | Gas Chromatography–Mass Spectrometry (GC-MS) System |
| Vacuum System | High-Performance Turbomolecular Pump |
| Ion Source | Dual-Filament EI Source, Inert (Non-Coated, Non-Stainless Steel) |
| Mass Analyzer | Gold-Plated Quartz Quadrupole with Turner-Kruge Lenses |
| Mass Range | 1.6–1050 u (0.1 u increments) |
| Resolution | Unit Mass Resolution |
| Mass Stability | ≤0.10 u / 48 h |
| Full-Scan Sensitivity (EI) | ≥400:1 S/N for 1 pg OFN (m/z 272, 50–300 u scan) |
| SIM Sensitivity (EI) | ≥10:1 S/N for 20 fg OFN |
| Max Scan Rate | 12,500 u/s (1 ms dwell in SIM) |
| Dynamic Range | 10⁶ |
| SIM Capacity | 100 groups, up to 60 ions/group |
| GC Oven Temp Range | 4 °C above ambient to 450 °C |
| Max Ramp Rate | 120 °C/min |
| Temperature Stability | <0.01 °C per 1 °C ambient change |
| Programmable Temperature Zones | ≥6 heated zones (including inlet, detector, transfer line), all independently controlled up to 400 °C |
| EPC Pressure Control Accuracy | ±0.001 psi |
| Split/Splitless Inlet | Up to 7500:1 split ratio, 0–1250 mL/min H₂/He flow range |
| Auto-sampler | 16-position (standard), optional 150-position tray |
| Detectors Included | FID (detection limit <1.8 pg C/s), micro-ECD (<6 fg/mL lindane), NPD (<0.4 pg N/s, <0.2 pg P/s) |
| Compliance | Fully compatible with EPA Methods (e.g., 502.2, 524.4, 8260, 8270), USP <621>, ASTM D5845, and GLP/GMP data integrity requirements per FDA 21 CFR Part 11 |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | Agilent 7890B + 5977A |
| Configuration | Gas Chromatography–Mass Spectrometry (GC-MS) System |
| Ion Source | High Efficiency Source (HES) with Electron Ionization (EI) |
| Detection Limit (IDL) | 1.5 fg (as reported for chlorobenzene, per Agilent specification) |
| Sensitivity Gain | Up to 10× vs. prior-generation single quadrupole MSDs |
| Pump Option | IDP-3 Dry Scroll Vacuum Pump (optional, low-noise, oil-free operation) |
| Software Platform | Agilent MassHunter Workstation (v10.x or later, license transferable per Agilent policy) |
| Compliance | Designed to support GLP/GMP workflows |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 7890B |
| Instrument Type | Laboratory Gas Chromatograph |
| Temperature Control Range | Ambient +4 °C to 450 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Cool-down Time | ~6 min (450 °C to 50 °C) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setpoint Range | 0–970 kPa |
| Injector Total Flow Setpoint Range | 0–1200 mL/min |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 7890B |
| Carrier Gas Options | Helium, Hydrogen, Nitrogen |
| Column Oven Temperature Range | 0–450 °C |
| Maximum Ramp Rate | 120 °C/min |
| Detector Compatibility | FID, TCD, ECD, NPD, FPD, MSD (with appropriate interface) |
| Software Platform | OpenLab CDS (ChemStation-compatible mode available) |
| Compliance | ASTM D3606, D5186, ISO 10301, USP <621>, FDA 21 CFR Part 11 (when configured with audit trail & electronic signature) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 7890B GC / 5977A MSD |
| Configuration | G4513A + G4514A (7693A) Autosamplers (150-position tray), Edwards Turbo Pump, MassHunter Software Suite |
| Warranty | 90-day comprehensive hardware warranty |
| Condition | Refurbished & fully validated by SpectraLab Scientific |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 7890B-5977B |
| Instrument Type | Ion Trap Mass Spectrometer |
| Chromatography Type | Conventional Gas Chromatography-Mass Spectrometry |
| Mass Range | 1–1000 m/z |
| Resolution | 1000–2000 (full width at half maximum, FWHM) |
| Sensitivity | >300:1 signal-to-noise ratio (S/N) for methyl stearate or chlorobenzene (typical electron ionization, EI) |
| Scan Speed | 15,000 u/s |
| Inlet Pressure Range | 0–100 psi (optional 0–150 psi) |
| Carrier Gas Flow Control | Electronic Pressure Control (EPC) |
| Oven Temperature Range | 4 °C above ambient to 450 °C |
| Detection Limit (FID) | <5 pg C/s (propane) |
| Autosampler | Agilent 7683 with 100-position tray |
| Injection Volume | 0.1–100 µL |
| Total Flow Range | 0–200 mL/min (N₂), 0–1000 mL/min (H₂ or He) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | Agilent 7890B-5977B |
| Instrument Type | Single Quadrupole Gas Chromatography-Mass Spectrometry (GC/MS) System |
| Typical Service Life | 6–8 years |
| Warranty | 12 months post-installation |
| Compliance | ASTM D5845, EPA Methods 524/8260/8270, ISO 17025-compatible operation |
| Software Platform | MassHunter Workstation (v10.2 or later) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 7890B GC, G7010A MS |
| Product Category | Mass Spectrometer |
| Usage Duration | 3–4 years |
| Warranty Period | 6 months |
| Instrument Model | 7890B, G7010A |
| Instrument Age | 4 years |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 7900 |
| Instrument Type | Quadrupole Mass Spectrometer |
| Application Environment | Laboratory |
| Detection Principle | Inductively Coupled Plasma Ionization with Quadrupole Mass Filtering |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 8000 |
| Usage Duration | 2–3 years (as verified) |
| Warranty | 6 months |
| Instrument Age | 4 years |
| Configuration | Includes Agilent 810 peristaltic pump |
| Certification Status | Functionally tested and validated by SpectraLab Scientific |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic Instrument |
| Model | 8255 NCD |
| Pricing | Available Upon Request |
| Compatible Instrument | Gas Chromatograph (GC) |
| Detector Type | Selective Nitrogen-Specific Detector |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | 8355 SCD |
| Pricing | Available Upon Request |
| Compatible Instrument | Gas Chromatograph (GC) |
| Detector Type | Elemental-Specific Chromatographic Detector |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 8453 |
| Wavelength Range | 190–1100 nm |
| Detector | 1024-element Diode Array |
| Wavelength Accuracy | < ±0.2 nm (at 486.0 nm & 656.1 nm) |
| Wavelength Repeatability | < ±0.02 nm |
| Spectral Bandwidth | 1 nm |
| Stray Light | < 0.03% T (at 340 nm, NaNO₂ solution, ASTM method) |
| Photometric Accuracy | ±0.005 A (at 440 nm & 590 nm, 1.0 A NDL) |
| Baseline Flatness | ±0.001 A |
| Stability | ±0.001 A/h |
| Light Source | Pre-aligned Deuterium & Tungsten Lamps |
| Interface | GPIB & LAN |
| Compliance | USP <857>, EP 2.2.25, FDA 21 CFR Part 11 (with optional security software) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 8453 |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | < ±0.2 nm |
| Spectral Bandwidth | 1 nm |
| Stray Light | ≤ 0.03% T |
| Automation Level | Automatic Wavelength Scanning |
| Instrument Classification | Imported High-Performance UV-Vis Spectrophotometer |
| Brand | Agilent Technologies |
|---|---|
| Origin | Imported |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Online Sampling System |
| Model | 850-DS |
| Compliance | Compatible with USP <711>, <724>, and ASTM D8239-22 |
| Pump Architecture | Integrated Rotary Piston Pump |
| Filtration | Optional 8-channel Whatman/Cytiva filter plate module |
| Sample Interface | Direct-to-HPLC vial tray (Agilent 1260/1290-compatible format) |
| Method Support | USP Apparatus 1 (Basket), 2 (Paddle), 3 (Reciprocating Cylinder), 5 (Paddle-over-Disk), 6 (Rotating Cylinder), and 7 (Reciprocating Holder) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | 8697 |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Valve Temperature Control Range | Ambient + 5 °C to 300 °C |
| Sample Vial Capacity | 48 positions |
| Compatible Vial Sizes | 10 mL, 20 mL, 22 mL |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | 8697 |
| Pricing | Available upon request |
| Temperature Control Precision | Optional cooling plate enables sample stabilization at 4 °C |
| Vial Sizes Supported | 10 mL, 20 mL, 22 mL |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 8860 |
| Configuration | Dual Inlet, Triple Detector Capable (including Single Quadrupole MS-ready), Full Electronic Pressure Control (EPC), Touchscreen Interface, OpenLab CDS Compatible |
| Compliance | Designed to support GLP/GMP workflows, 21 CFR Part 11–ready with audit trail enabled in OpenLab CDS |
| Software | Agilent OpenLab CDS (v2.4+), DA Express (optional), RTL-enabled methods |
| Environmental Compensation | Yes (temperature & barometric pressure) |
| Diagnostic Capability | Built-in GC Health Check, Baseline Anomaly Detection, Detector Performance Assessment, Method Transfer Validation Support |
| Rental Options | Short-term lease (≥1 month), Lease-to-own, Capital lease with title transfer |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Regional Classification | Domestic (China) |
| Model | 8860 GC |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Temperature Control Range | +8 °C above ambient to 425 °C |
| Maximum Ramp Rate | 75 °C/min |
| Cooling Rate | 300 °C to 50 °C in 5.7 min (at 25 °C ambient) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | Agilent 8860 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Domain | Ultra-High-Purity (UHP) Electronic Specialty Gas Analysis |
| Oven Temperature Range | 8 °C above ambient to 425 °C |
| Maximum Ramp Rate | 75 °C/min |
| Cooling Rate | 300 °C → 50 °C in ≤5.7 min (at 25 °C ambient) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Zhejiang, China |
| Model | Agilent 8860 |
| Detector Type | Pulsed Discharge Helium Ionization Detector (PDHID) |
| Column Oven Temp Range | 8 °C above ambient to 425 °C |
| Max Ramp Rate | 75 °C/min |
| Cooling Rate | 300 °C → 50 °C in ≤5.7 min (at 25 °C ambient) |
| Temperature Resolution | 0.1 °C |
| Max Run Time | 999.99 min |
| PDHID Detection Limit | ≤10 ppb (as CH₄) |
| Linear Dynamic Range | 10⁵ |
| Measurable Impurities | H₂, O₂/Ar, N₂, CH₄, CO, CO₂, C₂H₆ |
| Compliance | GB/T 28726–2012, JJG 700–2016, GB/T 8979–2008, GB/T 4842–2006, GB/T 4844.3–2005, GB/T 3634.2–2011, GB/T 6052–2011 |
| Brand | Agilent Technologies |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | Agilent 8860 |
| Instrument Type | Laboratory Gas Chromatograph |
| Detection Principle | Pulsed Discharge Helium Ionization Detection (PDHID) |
| Column Oven Dimensions | 28.0 × 30.5 × 16.5 cm |
| Operating Temperature Range | 8 °C above ambient to 425 °C |
| Temperature Setpoint Resolution | 0.1 °C |
| Max Heating Rate | 75 °C/min |
| Cooling Rate | 300 °C → 50 °C in ≤5.7 min (at 25 °C ambient) |
| Max Run Time | 999.99 min |
| Temperature Programming | Up to 20 ramps (including negative ramps) |
| Ambient Temperature Rejection | <0.01 °C per 1 °C ambient change |
| Analog Outputs | Two channels (1 V and 10 V standard) |
| Remote Control | Start/Stop via digital I/O |
| Connectivity | Ethernet (LAN) |
| Flow Selection Valve | BCD-encoded input |
| Operating Environment | 15–35 °C, 5–90% RH (non-condensing) |
| Storage Range | −40 to 70 °C |
| Max Operating Altitude | 4600 m |
| PDHID Detection Limit | ≤10 ppb (as CH₄) |
| Linear Dynamic Range | 10⁵ |
| Measurable Impurities in HBr | H₂, O₂, N₂, CH₄, CO, CO₂, C₂H₆, H₂O, HCl |
| Compliance Standards | GB/T 28726–2012, JJG 700–2016 |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 8860-5977B |
| Price Range | USD 68,000 – 136,000 |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | 8890 GC |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-purpose |
| Oven Temperature Range | +4 °C above ambient to 450 °C |
| Maximum Ramp Rate | 120 °C/min (75 °C/min with 120 V power supply) |
| Oven Cool-down | 4.0 min from 450 °C to 50 °C (ambient 22 °C) |
| Detector Options | FID, TCD, SCD, NCD, compatible with single-quadrupole, triple-quadrupole, and Q-TOF GC/MS platforms |
| Retention Time Reproducibility | <0.008% RSD |
| Peak Area Reproducibility | <0.5% RSD |
| Pressure Control Resolution | 0.001 psi |
| Dual-Tower Simultaneous Injection | Yes |
| Dimensions (W × D × H) | 58 cm × 51 cm × 49 cm |
| Microfluidic Flow Control Technology (CFT) | Fully integrated |
| Cryogenic Cooling Options | –80 °C (LN₂), –40 °C (CO₂) |
| Inlet Configurations | Up to 2 inlets + 10 valves |
| Environmental Certification | My Green Lab ACT Label (Accountability, Consistency, Transparency) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (China) |
| Model | Agilent 8890 PDD |
| Pricing | Available Upon Request |
| Detection Principle | Pulsed Discharge Helium Ionization Detection (PDHID) |
| Column Oven Range | 40 °C above ambient to 450 °C |
| Temperature Stability | < 0.01 °C per 1 °C ambient fluctuation |
| Max Ramp Rate | 120 °C/min |
| Cooling Time | ≤6 min (450 °C → 50 °C at 22 °C ambient) |
| LOD | 5–25 ppb (gas-dependent) |
| Compliance | GB/T 28726-2012, JJG 700-2016, GB/T 8979-2008, GB/T 4842-2006, GB/T 4844.3-2005, GB/T 3634.2-2011, GB/T 6052-2011 |
| Brand | Agilent Technologies |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | Agilent 8890 |
| Quotation | Upon Request |
| Detector | Dual-Pulse Helium Ionization Detector (PDHID) |
| Column Oven Temp Range | 40 °C above ambient to 450 °C |
| Temp Setpoint Resolution | 1 °C |
| Ramp Rate | 0.1–120 °C/min |
| Temp Stability | <0.01 °C per 1 °C ambient fluctuation |
| Programmable Temperature Steps | 20 ramps / 21 platforms |
| Max Run Time | 999.99 min |
| Cool-down | ≤6 min (450 °C → 50 °C at 22 °C ambient) |
| Detection Limits | 5–10 ppb for H₂, O₂/Ar, N₂, CH₄, CO, CO₂, C₂–C₄ hydrocarbons, SiH₃Cl, Si₂H₆, and other silicon-containing impurities in electronic-grade silane (≥99.9995% purity) |
| Compliance | GB/T 28726–2012, JJG 700–2016, GB/T 15909–2017 |
| Brand | Agilent Technologies |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Agilent 8890 |
| Pricing | Upon Request |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 8900 |
| Instrument Type | Quadrupole-based Triple Quadrupole Mass Spectrometer |
| Application Environment | Laboratory |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | 990 GC |
| Detection Limit | 0.5 ppm (on WCOT capillary column) |
| Repeatability | RSD < 0.5% for 1 mol% propane on WCOT column under isothermal and isobaric conditions |
| Carrier Gases | Helium, Hydrogen, Nitrogen, Argon |
| Column Oven Max Temperature | 180 °C |
| Injector Max Temperature | 110 °C |
| TCD Linear Dynamic Range | 10⁵ (0.5 ppm to 5%) |
| TCD Concentration Range | 0.5 ppm to 100% |
| Inlet Pressure Rating | 100 kPa (14.5 psi) |
| Sample Loop | Micro-machined, fixed-volume, non-split |
| Detector Type | Micromachined Dual-Channel Thermal Conductivity Detector (TCD) |
| Maximum Independent Channels | 4 |
| Column Types Supported | WCOT, PLOT, Micro-packed (Hayesep D, Carboxen) |
| Peak Area Reproducibility | < 0.5% RSD |
| Environmental Certification | My Green Lab ACT Label (Accountability, Consistency, Transparency) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | AA 280Z |
| Instrument Type | Atomic Absorption Spectrometer |
| Detection Principle | Zeeman-effect background-corrected graphite furnace AAS |
| Lamp Positions | 8 fixed hollow cathode lamp positions |
| Atomizer | Agilent GTA 120 Zeeman graphite furnace atomizer |
| Autosampler | Agilent PSD 120 programmable sample dispenser |
| Software Platform | Agilent Windows-based worksheet software with SRM Wizard and Tube-Cam functionality |
| Operational Age | 4 years |
| Warranty | 6 months limited hardware warranty |
| Compliance | Designed to support GLP/GMP workflows |
| Sample Introduction | Electrothermal (graphite tube) |