Agilent Technologies
Filter
Showing 271–300 of 567 results
| Brand | Agilent Technologies |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 7890A GC, G3935A 240 Ion Trap MS |
| Product Category | Mass Spectrometer |
| Operational Age | 3–4 Years |
| Warranty | 1 Year |
| Software Included | MassHunter Workstation (GC/MS Acquisition & Qualitative Analysis) |
| Compliance | Fully Refurbished & Performance-Verified per Agilent-recommended protocols |
| Brand | Agilent Technologies |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 7890A, DiscovIR-GC |
| Price Range | USD $38,000–$64,000 (FOB) |
| Product Category | Spectroscopy |
| Operational Age | 3–4 years |
| Warranty | 6 months |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | Agilent 7890A |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Environmental Monitoring |
| Temperature Control Range | Ambient to 450 °C (oven) |
| Ramp Rate | Up to 120 °C/min |
| Cool-down Rate | From 450 °C to 50 °C in <3.5 min |
| Carrier Gas Flow Range | 0–1200 mL/min (He, H₂, N₂) |
| Carrier Gas Pressure Control | 0–100 psi (EPC resolution: 0.001 psi) |
| Inlet Pressure Setting Range | 0–100 psi (split/splitless), 0–150 psi (high-pressure option) |
| Total Inlet Flow Setting Range | 0–1200 mL/min |
| Inlet Operating Temperature | Up to 450 °C |
| Brand | Agilent Technologies |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | 7890A GC / 5975C MSD |
| Product Category | Chromatography System |
| Operational Age | 5–7 Years |
| Warranty | 6 Months |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 7890A, 7693 (G4513A) |
| Sample Capacity | 150-position tray |
| Inlet Type | Split/Splitless (SSL) |
| EPC Precision | ±0.001 psi |
| Column Oven Cooling Rate | Up to 120 °C/min |
| Operating Age | 4 years |
| Warranty | 6 months |
| Compliance | ASTM D3606, ISO 10301, USP <621>, FDA 21 CFR Part 11 ready (with optional software configuration) |
| Software Platform | OpenLab CDS (ChemStation-compatible mode available) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Configuration | Gas Chromatography–Triple Quadrupole Mass Spectrometry (GC-QQQ) |
| Model | 7890A GC System + 7000B MS/MS |
| Condition | Certified Pre-Owned, Fully Refurbished and Performance-Verified |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 7890A + 5975C |
| Ion Source Temp Range | 100–300 °C (independently controlled) |
| Electron Energy | 10–200 eV |
| Sensitivity (EI) | ≥185:1 S/N for 1 pg OFN (m/z 272, full scan) |
| Sensitivity (NCI) | ≥300:1 S/N for 10 fg OFN (m/z 272, SIM) |
| Mass Range | 1.5–1050 amu |
| Resolution | Unit mass |
| Scan Speed | ≥10,000 amu/sec |
| Mass Axis Stability | ≤0.1 amu/48 h |
| Detector | Off-axis electron multiplier |
| Quadrupole | All-metal molybdenum, pre-filtered, permanently contamination-resistant |
| Carrier Gas Options | Helium, Hydrogen, Nitrogen |
| Software | MSD ChemStation with Deconvolution Reporting Software (DRS), Retention Time Locking (RTL), Capillary Flow Technology support |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 7890A + 7000A/B |
| Configuration | Gas Chromatography–Triple Quadrupole Mass Spectrometry (GC–MS/MS) |
| Ion Source | Electron Ionization (EI) |
| Collision Gas | Nitrogen/He Mix |
| Detector Type | Triple Quadrupole (QqQ) |
| Regulatory Compliance Support | ASTM D5845, EPA Method 8270/1613/1631, USP <621>, FDA 21 CFR Part 11 (Software-Enabled) |
| Data System | MassHunter Workstation (vB.08.x or later) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 7890A |
| Configuration | Dual Inlet / Triple Detector (incl. TCD) |
| EPC Channels | Up to 16 |
| Temperature Range | –80 °C to 450 °C (with LN₂ cooling) |
| Retention Time Reproducibility | < 0.008% RSD |
| Peak Area Reproducibility | < 1% RSD |
| Column Oven Dimensions | 28 × 31 × 16 cm |
| Max Ramp Rate | 120 °C/min |
| Cooling from 450 °C to 50 °C | 4.0 min (standard), 3.5 min (with insert) |
| Pressure Control Precision | ±0.001 psi (0–99.999 psi range) |
| Data Acquisition Rate | Up to 500 Hz (FID) |
| Supported Detectors | FID, TCD, Micro-ECD, NPD, FPD, SCD, NCD, MSD (via interface) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | GC 7890A |
| Condition | Refurbished & Certified Pre-Owned |
| Compliance | Fully Tested to Original Agilent Specifications |
| Software | Compatible with OpenLab CDS (Legacy ChemStation Support Available) |
| Detector Options | FID, TCD, ECD, NPD, PID (Configurable per Unit) |
| Column Compatibility | Standard 1/4" and 0.53 mm ID Capillary Columns |
| Carrier Gas | Helium, Hydrogen, or Nitrogen (with Electronic Pressure Control) |
| Temperature Range | Oven: -10 °C to 450 °C (with LN2 cooling option available) |
| Injector | Up to 450 °C |
| Detector | Up to 450 °C |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 7890A |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | Ambient + 4 °C to 450 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cool-Down Rate | 450 °C to 50 °C (typical) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setpoint Range | 0–970 kPa |
| Injector Total Flow Setpoint Range | 0–1200 mL/min |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | Agilent 7890A |
| Operational Age | 4–5 years |
| Configuration | Standard GC system with integrated 7683 autosampler control |
| Regulatory Readiness | Built-in 21 CFR Part 11 compliance features (audit trail, electronic signature support, user access levels) |
| Detection Options | FID, TCD, µECD, NPD, MSD, ICP-MS, and optional PFPD, SCD, AED via Agilent partner ecosystem |
| Injection Modes | Split/splitless (0–100 psi & 0–150 psi), packed column, on-column, PTV, and volatile analysis interface |
| Data Systems | Compatible with Agilent ChemStation Plus (ChemStore C/S, ChemAccess), PetroQA/QC Cerity NDS |
| Speed Capability | Fast GC mode (up to 10× faster than conventional GC) |
| Sample Introduction | Supports headspace, purge-and-trap, valve injection, and large-volume injection (LVI) without pre-concentration |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | Agilent 7890A |
| Instrument Age | 4–5 years |
| Configuration | Includes integrated Agilent 7683 autosampler control |
| Detector Options | FID, TCD, µECD, NPD, MSD, ICP-MS, FPD (upgraded), plus optional SCD, PFPD, AED via Agilent Partners |
| Inlet Types | Split/splitless (0–100 psi & 0–150 psi), packed column, on-column, PTV, VOA |
| Software Compatibility | Agilent ChemStation Plus (ChemStore C/S, ChemAccess), Cerity QA/QC for Petrochemicals |
| Regulatory Compliance | Supports 21 CFR Part 11 audit trails, GLP/GMP data integrity requirements |
| GC Speed | Capable of fast GC operation (up to 10× faster than conventional GC) |
| Sample Introduction | Large-volume injection (LVI) enabled, headspace, purge-and-trap, valve-based injection modules available |
| Brand | Agilent Technologies |
|---|---|
| Origin | Canada |
| Model | 7890A-5975C (G3172A) |
| Instrument Type | Gas Chromatography–Mass Spectrometry (GC-MS) |
| Mass Analyzer | Quadrupole |
| Detector | Triple-Axis Electron Multiplier |
| Mass Range | 1.6–1050 u |
| Scan Speed | Up to 12,000 u/sec |
| Sensitivity | 1 pg OFN (octafluoronaphthalene), S/N ≥ 400:1 (m/z 272) |
| Operating Age | 3–4 years |
| Compliance | Fully Functional per Agilent G3172A Specification |
| Warranty | Not Included |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 7890A-5975C |
| Mass Range | 1–1050 u |
| Scan Rate | 12,500 u/s |
| Sensitivity | 20 pg/μL octafluoronaphthalene (OFN), S/N ≥ 10:1 at m/z 272 |
| Ion Source Temperature | Up to 300 °C |
| Quadrupole | Heated dual-curved rod assembly |
| Carrier Gas Compatibility | Helium, Hydrogen, Nitrogen |
| Software | MSD ChemStation with Deconvolution Reporting Software (DRS), Retention Time Locking (RTL), Capillary Flow Technology support |
| Warranty | 90-day parts and labor |
| Brand | Agilent Technologies |
|---|---|
| Origin | Canada |
| Model | 7890A (G3440A)-5975C |
| Instrument Type | Quadrupole GC-MS |
| Operating Age | 3–4 years |
| Power Supply | 230 V, 50/60 Hz |
| Shipping Dimensions | 1300 × 650 × 900 mm |
| Shipping Weight | 100 kg |
| Certification Status | CE-compliant post-refurbishment |
| Warranty | Not included |
| Brand | Agilent Technologies |
|---|---|
| Origin | Canada |
| Model | 7890A-5975C (G3171A) |
| Instrument Type | Gas Chromatography–Mass Spectrometry (GC-MS) |
| Mass Analyzer | Quadrupole |
| Ion Source | Inert Triple-Axis Detector |
| Age | 3–4 years |
| Warranty | None |
| Configuration | Refurbished with CTC GC PAL Autosampler |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 7890A GC / 5975C MSD |
| Instrument Type | Ion Trap Mass Spectrometer |
| Chromatography Type | Conventional Gas Chromatography-Mass Spectrometry |
| Mass Range | 1–1000 m/z |
| Resolution | 1000–2000 (full width at half maximum, FWHM) |
| Sensitivity | >300:1 signal-to-noise ratio (S/N) for methyl stearate at 1 pg on-column injection |
| Scan Speed | 15,000 u/s |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | WX-7890A-5975C |
| Service Fee | USD 700–1,400 (excl. parts) |
| Technician Experience | 10 years |
| Instrument Type | Analytical Instrument |
| Response Time | ≤12 hours |
| Service Scope | GC-MS Maintenance, Calibration, Fault Diagnosis & Component-Level Repair |
| Location | Beijing, China |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | 7890A-5975C |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| GC Configuration | Conventional GC-MS |
| Mass Range | m/z 1–1000 |
| Resolution | 1000–2000 (at 10% valley, peak width at half height) |
| Sensitivity | >300:1 (Signal-to-Noise Ratio, SIM mode, using octafluoronaphthalene) |
| Scan Speed | 15,000 u/s |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Agilent 7890A GC / 7000A Triple Quadrupole MS |
| Product Category | Mass Spectrometer |
| Operational Age | 6–8 years |
| Warranty | 12 months |
| Instrument Configuration | Gas Chromatograph coupled with Triple Quadrupole Mass Spectrometer |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 7890A-7000B |
| Instrument Type | Triple Quadrupole Mass Spectrometer |
| Chromatography Type | Conventional GC-MS |
| Mass Range | 1.2–1050 amu (0.1 amu increment) |
| Resolution | Unit Mass Resolution |
| Sensitivity | Auto-tune Mode |
| Scan Speed | 150,000 u/s |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 7890A-7000B |
| Product Category | Mass Spectrometer |
| Operational Age | 4 years |
| Warranty | None |
| Price Range | USD $38,000–$64,000 (FOB) |
| Software Platform | MassHunter Workstation v10.x or later |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | Agilent 7890A-7000B |
| Instrument Type | Triple Quadrupole Gas Chromatography–Mass Spectrometry (GC-MS/MS) System |
| Operational Age | 6–8 years |
| Warranty | 6 months |
| Category | Second-hand Analytical Instrument |
| Compliance | Designed to meet ASTM D5845, EPA Method 8270/1613/1631, and ISO/IEC 17025-aligned laboratory practices |
| Software Platform | MassHunter Workstation (vB.08.x or later, validated for GLP environments) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 7890A–7000A |
| Product Category | Mass Spectrometer |
| Operational Age | 4–5 years |
| Warranty Period | 6 months |
| Instrument Model | 7890A–7000A |
| Usage Duration | 4 years |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | 7890B |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Petrochemical Industry |
| Heating/Cooling Rate | Enabled by Low Thermal Mass (LTM) modules for direct, rapid column heating and cooling |
| Compliance | Designed to support GLP/GMP workflows with audit-trail-capable data systems (when paired with OpenLab CDS or ChemStation software) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 7890B |
| Configuration | GC Mainframe with S/SL Inlet, FID Detector, 80-PAL Autosampler |
| Warranty | 90-day comprehensive hardware warranty |
| Certification | Fully tested and validated per Agilent-recommended performance verification protocols |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | Agilent 7890B |
| Instrument Type | Gas Chromatograph |
| Age Range | 6–8 years |
| Warranty | 12 months |
| Compliance | Fully refurbished to meet original Agilent performance specifications |
| Software | Compatible with OpenLab CDS (ChemStation legacy support available) |
| Detector Options | FID, TCD, ECD, NPD, PID (configuration-dependent) |
| Column Compatibility | Standard 1/4" and 0.53 mm ID capillary columns |
| Carrier Gas Control | Electronic Pressure Control (EPC) across all inlets and detectors |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Instrument Origin | Imported |
| Model | 7890B + 7010B |
| Price | USD 95,000 (FOB) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 7890B + 7000C/D |
| Configuration | GC with ALS G7693A, Heated EI Extractor Ion Source, Gold-Plated Quadrupole Mass Filters, HED-EM Detector, Dual Turbo Molecular Pumping System, MassHunter Software Suite |
| Compliance | ASTM D5845, EPA Methods 8270/1613/1631, USP <621>, ISO/IEC 17025 |
| Service History | Fully Refurbished & Performance-Verified per Agilent OEM Standards |