Anton Paar
Filter
Showing 181–199 of 199 results
| Brand | Anton Paar |
|---|---|
| Origin | Switzerland |
| Manufacturer | Anton Paar GmbH |
| Type | High-Temperature Tribological Tester |
| Model | THT |
| Maximum Friction Force | 20 N |
| Friction Force Resolution | 0.03 mN |
| Maximum Operating Temperature | 1000 °C |
| Rotational Speed Range | 0.3–500 rpm (optional up to 1500 rpm) |
| Maximum Torque | 450 N·mm |
| Compliance Standards | DIN 50324, ASTM G99, ASTM G133 |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | TPO 5000 |
| Instrument Type | Beer-Specific Analyzer |
| Application Mode | Online & Laboratory |
| Measurement Time | 4 min |
| Dimensions (L × W × H) | 515 × 590 × 1120 mm |
| Weight | 70 kg |
| Brand | Anton Paar |
|---|---|
| Origin | Switzerland |
| Manufacturer | Anton Paar GmbH |
| Type | Multifunctional Tribological Tester |
| Model | TRB³ |
| Maximum Normal Force | 60 N |
| Normal Force Resolution (net weight) | Not specified |
| Maximum Friction Force | 20 N (optional 5 N) |
| Friction Force Resolution | 0.015 mN (optional 0.06 mN) |
| Rotational Speed Range | 0.2–2000 rpm (optional up to 600 rpm) |
| Linear Reciprocating Stroke | up to 60 mm |
| Linear Reciprocating Speed | up to 370 mm/s |
| Linear Frequency Range | 0.01–10 Hz |
| Oscillatory Rotational Speed | 0.2–2000 rpm |
| Oscillatory Frequency Range | 0.01–7 Hz |
| Angular Amplitude Range | ±5° to ±150° |
| Angular Resolution | 0.1° |
| Heating Capability | up to 450 °C (dry), up to 150 °C (liquid) |
| Vacuum Level | down to 10⁻⁷ mbar |
| Relative Humidity Control | 15–95% RH |
| Contact Resistance Measurement | up to 1000 Ω |
| Online Wear Depth Measurement (optional) | −2 to +2 mm |
| Brand | Anton Paar |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Ultratap 500 |
| Instrument Type | Bulk Density Tester |
| Instrument Class | Benchtop Laboratory |
| Sample Type | Solid Powders & Granules |
| Density Accuracy | 0.001 g/cm³ |
| Repeatability | 0.0001 g/cm³ |
| Resolution | 0.0001 g/cm³ |
| Minimum Sample Volume | 5 mL |
| Vibration Frequency Range | 50–350 taps/min |
| Tap Amplitude | 3 mm ± 0.2 mm or 14 mm ± 1 mm |
| Noise Level | 65 dB (58 dB with optional noise-reduction cabinet) |
| Touchscreen | 7-inch TFT WVGA (800 × 480 px), PCAP |
| User Management | Password-protected |
| Built-in Methods | 24 (ASTM, ISO, USP <616> Methods 1–3) |
| Data Storage | 1,000 reports / 100 custom methods |
| Dimensions (H×W×D) | 228.6 × 263.5 × 361 mm (9 × 10.4 × 14.2 in) |
| Weight | 14.5 kg (single station) / 17.6 kg (dual station) |
| Power Input | 24 V DC, 2.1 A (51 W) / 2.6 A (63 W) |
| Brand | Anton Paar |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | UNHT³ Bio |
| Instrument Type | Biological Nanoindenter |
| Maximum Indentation Depth | 100 µm |
| Effective Load Range | 20 mN |
| Load Resolution | 1 nN |
| Displacement Resolution | 0.006 nm |
| Brand | Anton Paar |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | UNHT³ HTV |
| Instrument Type | Ultra-Nanoindentation Tester |
| Maximum Indentation Depth | 100 µm |
| Effective Load Range | 100 mN |
| Load Resolution | 3 nN |
| Displacement Resolution | 0.003 nm |
| Thermal Drift (Ambient) | < 0.5 nm/min |
| Thermal Drift (Up to 800 °C) | < 3 nm/min |
| Frame Stiffness | > 10⁶ N/m |
| Frame Compliance | < 0.1 nm/mN |
| Vacuum Base Pressure | 1×10⁻⁷ mbar |
| Maximum Operating Temperature | 800 °C |
| Temperature Stability | ±0.1 °C (surface-controlled) |
| Compliance Standards | ISO 14577, ASTM E2546 |
| Brand | Anton Paar |
|---|---|
| Origin | Switzerland |
| Manufacturer | Anton Paar GmbH |
| Type | Nanoindentation and Scratch Tester |
| Model | UNHT³ |
| Indentation Depth Range | 0–100 µm |
| Load Range | 10 µN – 100 mN |
| Load Resolution | 3 nN |
| Displacement Resolution | 0.003 nm |
| Thermal Drift | <3 nm/min |
| Frame Stiffness | >10⁸ N/m |
| Compliance with Standards | ISO 14577, ASTM E2546 |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Model | Visco QC100 / Visco QC300 |
| Instrument Type | Benchtop Rotational Viscometer |
| Viscosity Range | 1 mPa·s to 320 × 10⁶ mPa·s (320 M) |
| Speed Range | 0.01–250 rpm |
| Accuracy | ±1.0% of full scale |
| Repeatability | ±0.2% |
| Temperature Monitoring | T-Ready real-time thermal equilibrium detection (no integrated Peltier or bath control) |
| Display | 3.5″ color LCD (QC100) / 7″ color touchscreen (QC300) |
| Data Storage | Up to 999 measurements (QC300) |
| Compliance | GMP, GAMP 5, PQP-S & PQP qualification packages available |
| Software | V-Collect PC software, V-Curve (rheological curve analysis), V-Comply (audit-trail & electronic signature) |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | ViscoQC 100 |
| Instrument Type | Benchtop Rotational Viscometer |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 1–6,000,000 mPa·s (L), 10–40,000,000 mPa·s (R), 60–320,000,000 mPa·s (H) |
| Temperature Range | +15 °C to +80 °C |
| Temperature Accuracy | ±1.0 % of full scale |
| Speed Range | 0.1–200 rpm (19 standard + 6 user-definable speeds) |
| Torque Range | 0.067–75.7496 mN·m |
| Accuracy | ±1.0 % of full scale |
| Repeatability | ±0.2 % of full scale |
| Compliance | ISO 2555, ISO 3219, ASTM D2196, USP <911>, GMP/GLP-ready |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Model | ViscoQC 100-L |
| Instrument Type | Benchtop Rotational Viscometer |
| Viscosity Range | 1–6,000,000 mPa·s (L-model optimized for low-viscosity range) |
| Temperature Range | +15 °C to +80 °C (Peltier-controlled, air-backflow cooling) |
| Temperature Resolution & Accuracy | 0.01 °C |
| Speed Range | 0.1–200 rpm (25 standard speeds + 6 user-definable) |
| Torque Range (L) | 0.0673 mN·m |
| Accuracy | ±1.0 % of full scale |
| Repeatability | ±0.2 % |
| Compliance | ISO 2555, GMP, GAMP 5, ASTM D2196, USP <911> |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | ViscoQC 300 |
| Instrument Type | Benchtop Rotational Viscometer |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 1–320 mPa·s |
| Temperature Control Range | +15 °C to +80 °C (with PTD 80, DIN/SSA geometry) |
| Compliance Standards | ASTM D2196, ISO 2555, ISO 3219, ISO 16520, USP <911>, EN ISO 12058 |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Model | ViscoQC 300-L |
| Instrument Type | Benchtop Rotational Viscometer |
| Viscosity Range | 1–320 mPa·s |
| Temperature Range | Ambient to 100 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Accuracy | ±0.01 °C |
| Measurement Principle | Rotational viscometry based on Couette flow geometry with defined shear rate control |
| Compliance Standards | ISO 2555, ISO 3219, ASTM D2196, USP <911> |
| Accuracy | ±1.0 % of reading |
| Repeatability | ±0.2 % |
| Sensor | Integrated Pt100 temperature probe |
| Display | 7-inch capacitive touchscreen |
| Toolmaster™ | Auto-recognition of spindle identity and calibration data |
| TruGuard™ | Automatic detection of protective guard sleeve presence |
| TruMode™ | Intelligent speed optimization algorithm for unknown samples |
| Digital Level | Real-time tilt compensation sensor for measurement axis alignment |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Wine Monitor |
| Pricing | Available Upon Request |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | XRDynamic 500 |
| Instrument Type | Small-Angle X-ray Scattering (SAXS) System |
| Instrument Configuration | Floor-Standing |
| Power | 0.0001° step size |
| Resolution | 0.021° FWHM (LaB₆ first standard peak) |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | XRDynamic Autosampler |
| Instrument Type | X-ray Crystal Orientation Analyzer |
| Instrument Configuration | Floor-standing |
| Sample Capacity | Up to 105 positions |
| Compatible With | XRDynamic 500 XRD system |
| Integration | Native integration with XRDdrive software |
| Sample Holder Compatibility | Standard ISO/ASTM-compliant sample holders (powder, solid, fiber, foil, thin film, air-sensitive samples) |
| Measurement Modes | Reflective and transmission geometries |
| Automation Level | Fully automated sample loading, positioning, alignment, and beam path switching |
| Compliance | Designed to support GLP/GMP workflows with audit-trail-capable software logging |
| Brand | Anton Paar |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | Xsample Series |
| Sample Type | Liquid |
| Minimum Sample Volume | 5 mL / 10 mL (when coupled with DMA instruments) |
| Viscosity Range | up to 1000 mPa·s |
| Instrument Class | Benchtop Laboratory |
| Application Scope | Universal Density Measurement |
| Compliance | Designed for GLP/GMP-aligned workflows, compatible with FDA 21 CFR Part 11–enabled software environments |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Model | Extensograph |
| Sample Mass | 300 g flour + 6 g salt + distilled water |
| Dough Kneading Speed | 83 ±3 rpm |
| Resting Time | 15 ±1 min |
| Stretching Speed | 14.5 ±0.5 mm/s |
| Maximum Extension Length | 680 mm |
| Measurement Range | 0–2,000 EU/BU |
| Fermentation Temperature Control | 30 °C (adjustable, with ambient compensation up to 40 °C) |
| Humidity Control | Ultrasonic humidification system |
| Dimensions (W × H × D) | 840 × 720 × 500 mm |
| Weight | ~115 kg |
| Power Supply | 100–240 V, 50/60 Hz, 0.24 kW |
| Interfaces | USB (4), LAN/Ethernet (2), HDMI (1) |
| Compliance Standards | ISO 5530-2, DIN EN ISO 5530-2, CEN EN ISO 5530-2, AACC 54-10.01, ICC Standard 114/1, GB/T 14615, GB/T 35994, NF V03-717-2, OENORM EN ISO 5530-2, SN EN ISO 5530-2, BS EN ISO 5530-2, UNE-EN ISO 5530-2, IRAM 15856, TCVN 7848-2, AGSA 06-01, CCAT 03 & 16 |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Model | FarinoGraph E-300 |
| Compliance | ISO 5530-1, ISO 5530-2, AACCI 54-22.01, ICC 114/1, GB/T 14614, DIN EN ISO 5530-1 |
| Torque Range | Up to 28 N·m |
| Measurement Duration | 0–200 min |
| Power Supply | 230 V (184–264 V) / 50–60 Hz, 1 kW or 115 V (88–126 V) / 50–60 Hz, 1 kW |
| Dimensions (W×H×D) | 430 × 630 × 740 mm |
| Weight (without mixer) | 56 kg |
| Weight (with S300 mixer) | 74 kg |
| Interfaces | 4× USB, 1× HDMI, 2× Ethernet |
| Software | MetaBridge v3.x with AI-assisted curve interpretation and audit-trail-enabled data management |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Viscograph-E |
| Price | USD 135,000 (FOB Hamburg) |