Anton Paar
Filter
Showing 121–150 of 199 results
| Brand | Anton Paar |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | MHT³ |
| Instrument Type | (Micro/Nano) Scratch Tester |
| Load Range | 10 mN – 30 N |
| Load Resolution | 6 µN |
| Load Noise (RMS) | 100 µN |
| Depth Range | 0–1000 µm |
| Depth Resolution | 0.03 nm |
| Depth Noise (RMS) | 1.5 nm |
| Data Acquisition Rate | 192 kHz |
| Scratch Speed | 0.1–600 mm/min |
| Maximum Heating Temperature (Peltier) | 120 °C |
| Optional Heating Stage | up to 200 °C |
| Optional Cryo Cooling | down to −120 °C |
| Liquid Environment Testing | Yes |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer | Anton Paar GmbH |
| Product Type | Imported Precision Resistance Thermometer |
| Model | MKT 50 |
| Temperature Range | −260 °C to +962 °C (−436 °F to +1764 °F) |
| Resistance Range | approx. 0 Ω to 440 Ω |
| Temperature Accuracy | ±0.0001 °C (±0.1 mK) for Pt100 |
| Resistance Accuracy | < 0.4 mΩ |
| Resolution | 40 μΩ (0.1 ppm full scale) |
| Operating Ambient Temperature | 0 °C to 35 °C (32 °F to 95 °F) |
| Display | Graphic LCD with LED backlight, 128×64 dots (≈65 mm × 35 mm) |
| Power Supply | 2 × AA batteries (1.2–1.5 V) or AC adapter: 100–240 VAC, 50/60 Hz, output 7.5 VDC, 5.34 A, max 40 W |
| Dimensions | 240 mm × 190 mm × 110 mm |
| Weight | 2 kg |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Modulyzer |
| Pricing | Upon Request |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Monowave 200 |
| Instrument Type | Single-Mode Microwave Synthesizer |
| Temperature Range | Up to 260 °C (upgradeable to 300 °C) |
| Pressure Range | 0–20 bar (290 psi |
| Microwave Power | 850 W continuous non-pulsed output |
| Magnetron Frequency | 2450 MHz |
| Stirring Mechanism | Magnetic stirring |
| Reaction Volume | 0.5–20 mL |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer | Anton Paar GmbH |
| Instrument Type | Single-Mode Microwave Synthesizer |
| Model | Monowave 400 |
| Temperature Range | 0–300 °C |
| Pressure Range | 0–30 bar |
| Microwave Power | 850 W |
| Magnetron Frequency | 2.45 GHz |
| Stirring Mechanism | Magnetic Stirring |
| Reaction Volume | 30 mL |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Model | Monowave 400 / Monowave 200 |
| Temperature Range | 0–300 °C |
| Pressure Range | 0–30 bar (Monowave 400), 0–20 bar (Monowave 200 |
| Microwave Power | 850 W |
| Magnetron Frequency | 2450 MHz |
| Stirring Method | Magnetic stirring |
| Maximum Reaction Volume | 30 mL |
| Vial Material | Borosilicate glass or silicon carbide |
| Cap & Seal Material | PEEK with Teflon-coated silicone |
| Temperature Sensing | Dual IR pyrometer + fiber-optic probe |
| Integrated Camera | Yes (Monowave 400) |
| Autosampler Compatibility | MAS 24 (optional, requires mounting bracket G4) |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer | Anton Paar GmbH |
| Instrument Type | Single-Mode Microwave Synthesizer |
| Temperature Range | 0–300 °C |
| Pressure Range | 0–30 bar |
| Microwave Power | 850 W |
| Magnetron Frequency | 2.45 GHz |
| Stirring Mechanism | Magnetic Stirring |
| Reaction Volume | 30 mL |
| Coupling Interface | Fiber-Optic Raman Probe (Borosilicate-Glass Compatible) |
| Real-Time Monitoring | Time-Resolved In Situ Raman Acquisition |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Monowave 450 |
| Microwave Power | 850 W |
| Microwave Frequency | 2450 MHz |
| Temperature Control Range | 0–300 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Cavity Material | Corrosion-Resistant Stainless Steel |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Model | Monowave 50 |
| Temperature Range | Ambient to 250 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Reaction Vessel Capacity | 10 mL |
| Maximum Operating Pressure | 20 bar |
| Maximum Power Input | 315 W |
| Vessel Material | Borosilicate Glass |
| Lid Sealing Material | PTFE |
| Safety Locking Mechanism | Mechanical Interlock |
| Dimensions | 20 cm × 40 cm footprint |
| Weight | 8.5 kg |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Model | Monowave 50 |
| Temperature Range | Ambient to 250 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Maximum Operating Pressure | 20 bar (290 psi) |
| Reaction Volume | 6 mL |
| Heating Power | 315 W |
| Reactor Chamber Material | Borosilicate Glass |
| Seal Material | PTFE |
| Cap Material | Silicone |
| Dimensions | 25 cm × 40 cm × 20 cm |
| Weight | 8.5 kg |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Model | Multicube 48 |
| Digestion Capacity | 48 positions |
| Max. Temperature | 180 °C |
| Temperature Uniformity | ±1 °C |
| Heating Principle | PFA-coated graphite block heating |
| Power Rating | 800 W |
| Reagent Channels | 48 |
| Reaction Vessel Volume | 50 mL (A-class calibrated, dual刻度 at 25 mL and 50 mL) |
| Control Interface | 5.4″ capacitive touchscreen |
| Method Storage | up to 100 pre-programmed digestion protocols |
| Max. Continuous Operation | 450 days |
| Compliance | EPA Methods 3010a, 3020b, 3050b, 3060, 200.2, 200.7–200.9, 245.1, 365.1 |
| Software Features | 10-step programmable ramp/hold temperature profiles, 0.1 °C setpoint resolution, glove-compatible touch response, USB data export |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Model | Multiwave 5000 |
| Cavity Class | Industrial-grade |
| Sample Capacity | 0–64 samples per run |
| Microwave Source | Dual magnetron |
| Max Temperature | 1200 °C |
| Max Pressure | 200 bar |
| Brand | Anton Paar |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Anton Paar (Shanghai) Co., Ltd. |
| Product Type | Domestic Manufacturing |
| Model | Multiwave 5001 CN |
| Cavity Class | Industrial-Grade |
| Sample Capacity | 96 samples per batch |
| Microwave Source | Dual Magnetron |
| Max Temperature | 300 °C |
| Temperature Measurement Accuracy | ±0.1 °C |
| Temperature Control Stability | ±1 °C |
| Temperature Uniformity | ±1 °C |
| Max Pressure | 100 bar |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Multiwave 5001/3001 |
| Cavity Class | Industrial-Grade |
| Sample Capacity | 96 samples/batch |
| Microwave Source | Dual Magnetron |
| Max Temperature | 300 °C |
| Temp Measurement Accuracy | ±0.1 °C |
| Temp Control Stability | ±1 °C |
| Temp Uniformity | ±1 °C |
| Max Pressure | 200 bar / 100 bar |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Multiwave 5001CN |
| Cavity Class | Industrial-Grade |
| Batch Capacity | 96 samples |
| Microwave Source | Dual Magnetron |
| Max Temperature | 300 °C |
| Max Pressure | 100 bar |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Multiwave 7101 / 7301 / 7501 |
| Cavity Class | Industrial-Grade |
| Sample Capacity | Up to 41 positions (configurable) |
| Microwave Source | Single 2000 W Magnetron |
| Max Temperature | 300 °C |
| Temp Measurement Accuracy | ±0.1 °C |
| Temp Control Stability | ±0.3 °C |
| Temp Uniformity | Full-cavity uniformity (no spatial gradient) |
| Max Pressure | 199 bar |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Model | Multiwave GO |
| Cavity Class | Industrial-Grade |
| Batch Capacity | 12 samples |
| Microwave Source | Industrial Magnetron |
| Max Temperature | 260 °C / 300 °C (operational / safety limit) |
| Max Pressure | 2200 psi |
| Dimensions | ≤36 × 53 cm |
| Max Microwave Power | ≤900 W |
| Cooling Time to RT | ≤8 min (in situ) |
| Vessel Volume | 50 mL |
| Vessel Material | PTFE-TFM composite with integrated metal spring seal |
| Temperature Measurement Range | 20–400 °C |
| Accuracy | ±1 °C |
| Safety Certifications | ETL, GS, CE, ISO 9001 |
| Brand | Anton Paar |
|---|---|
| Country of Origin | Austria |
| Model | Multiwave GO Plus |
| Cavity Class | Industrial-grade |
| Sample Capacity | 12 samples per run |
| Microwave Source | Industrial Magnetron |
| Max Temperature | 260 °C / 300 °C (depending on vessel type) |
| Max Pressure | 2200 psi |
| Cooling Time (12-position rotor, 180 °C → 70 °C) | ≤8 min (EPA-compliant) |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Multiwave GO Plus |
| Cavity Class | Industrial-Grade |
| Sample Capacity | 12 samples per batch |
| Microwave Source | Industrial Magnetron |
| Max Temperature | 260 °C (standard), 300 °C (with optional high-temp configuration) |
| Temp Measurement Accuracy | ±1 °C |
| Temp Uniformity | ±5 °C |
| Max Pressure | 2200 psi |
| Reaction Vessel Volume | 50 mL |
| Vessel Material | PTFE-TFM |
| HF Resistance | Yes |
| Temperature Sensing | Infrared (per-vessel) |
| Pressure Control | Intelligent Active Pressure Monitoring |
| Cooling Time | <8 min (180 °C → 70 °C) |
| Compliance | EPA Methods 3015A, 3051A, 3052 pre-installed |
| Software | Multiwave GO Control Software with audit trail (21 CFR Part 11 ready) |
| Brand | Anton Paar |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China-manufactured under Anton Paar global engineering standards) |
| Model Series | Multiwave |
| Cavity Class | Industrial-grade |
| Batch Capacity | Up to 96 samples |
| Microwave Source | Dual Magnetron |
| Max Temperature | 300 °C |
| Temp Measurement Accuracy | ±0.1 °C |
| Temp Control Stability | ±1 °C |
| Temp Uniformity Across Cavity | ±1 °C |
| Max Pressure | 200 bar (high-pressure configuration) / 100 bar (standard configuration) |
| Brand | Anton Paar |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | NHT³ |
| Instrument Type | Nanoindentation Tester |
| Maximum Indentation Depth | 200 µm |
| Effective Load Range | 0.1 mN to 500 mN |
| Load Resolution | 20 nN |
| Load Noise (RMS) | ≤0.5 µN |
| Depth Resolution | 0.01 nm |
| Depth Noise (RMS) | ≤0.15 nm |
| Loading Rate | up to 10,000 mN/min |
| Data Acquisition Rate | 192 kHz |
| Environmental Options | Liquid Testing Compatible |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer | Anton Paar GmbH |
| Type | Imported Instrument |
| Model | NST³ |
| Instrument Category | Nanoindentation and Scratch Tester |
| Maximum Indentation Depth | 1 µm |
| Load Resolution | 0.01 µN |
| Displacement Range | 600 µm |
| Maximum Friction Force | 1 N |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Oxy 5100 |
| Price | Upon Request |
| Resolution | 0.4 ppb |
| Measurement Range | 0–2000 ppb or 0–24 ppm |
| Repeatability | ≤0.5 ppb or ≤1 % of reading |
| Long-term Stability | ≤0.8 ppb per 24 h |
| Temperature Compensation Range | –5 °C to +40 °C |
| Communication Interfaces | Analog Output (AO), Analog Input (AI), Digital Input (DI), Digital Output (DO), CAN bus |
| Dimensions (H × W × D) | 174 mm × 174 mm × 230 mm |
| Operating Ambient Temperature | –5 °C to +50 °C |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | OxyQC Wide Range |
| Price | Upon Request |
| Measurement Range (O₂) | 0.015 ppm to 45 ppm |
| Temperature Range | −3 °C to 40 °C (±0.2 °C accuracy) |
| Pressure Range | 0 to 10 bar absolute (±0.01 bar accuracy) |
| Repeatability | ±2 ppb (<200 ppb), ±20 ppb (<5 ppm) |
| Resolution | 0.1 ppb (<100 ppb), 1 ppb |
| Sample Volume | >100 mL (standard), >150 mL (with optional flow cell) |
| Measurement Time | ≤50 s |
| Data Storage | 500 measurement datasets |
| Display | High-contrast color LED touchscreen |
| Protection Rating | IP67 |
| Battery Life | Up to 11 hours (portable operation) |
| Interfaces | 1× RS-232, 1× USB |
| Dimensions (L×W×H) | 262 × 209 × 176 mm |
| Weight | 1.7 kg |
| Units Supported | ppm, ppb, mg/L, µg/L, hPa, % Air-sat., % O₂-sat. |
| Built-in Features | O₂ data logger, threshold alarms, system self-check |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Packaged Beer Measurement System |
| Instrument Type | Dedicated Beer Analyzer |
| Application | Laboratory-Based Quality Control |
| Measurement Time | 3 min per sample |
| Alcohol Content Range | 0–12 % v/v |
| pH Range | 0–14 |
| Dimensions (L × W × H) | 515 × 1200 × 1120 mm / 482 × 750 × 670 mm / 482 × 730 × 446 mm |
| Weight | 30 kg |
| Sampling Technology | Pressurized Direct Injection, No Sample Preparation Required |
| Sample Volume per Package | 260 mL |
| Throughput | 7 samples/hour or 15 samples/hour (depending on configuration) |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Product Category | Imported Instrument |
| Model | PMA 500 |
| Detection Method | Closed Cup Method |
| Operation Mode | Fully Automatic |
| Temperature Range | Ambient + X °C to 410 °C |
| Ignition Method | Electric Spark Ignition |
| Compliant Standards | ASTM D93, EN ISO 2719, IP 34, JIS K2265-3, GB/T 261 |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Perfume and Flavor Measurement System |
| Instrument Type | Oscillating U-tube Densimeter |
| Instrument Class | Benchtop Laboratory |
| Sample Type | Liquid |
| Density Range | 0–3 g/cm³ |
| Density Accuracy | ±0.01 g/cm³ |
| Display | 10.1″ TFT WXGA (1280 × 800 px) PCAP Touchscreen |
| Temperature Control Range | 0–100 °C |
| Minimum Sample Volume | 2 mL |
| Integrated Parameters | Density, Refractive Index, Optical Rotation, Colorimetry, Turbidity |
| Automation | Fully Automated Sample Handling with Recovery (Xsample 5200/530), Integrated Cleaning & Drying |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer | Anton Paar GmbH (Petrotest Division) |
| Type | Imported Instrument |
| Model | PetroOxy |
| Pricing | Upon Request |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer | Anton Paar GmbH |
| Product Type | Imported Instrument |
| Model | PMA 300 |
| Test Method | Closed-Cup (Pensky-Martens) |
| Operation Mode | Fully Automatic |
| Temperature Range | Ambient + ~10 °C to 370 °C |
| Ignition Source | Electronic (Encapsulated Hot-Wire) |
| Compliant Standards | ASTM D93, EN ISO 2719, IP 34, JIS K2265-3, GB/T 261 |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer | Anton Paar GmbH |
| Product Type | Imported Instrument |
| Model | PNR 12 |
| Pricing | Upon Request |