| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PoreMaster eGaIn Filling Station |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Principle | Static and Dynamic Mercury Intrusion Analogue (eGaIn-based) |
| Compatibility | Designed exclusively for Anton Paar PoreMaster main units and P-type penetrometers (0.5 mL × 1.5 in) |
| Safety Compliance | Mercury-free operation, ISO/IEC 17025-aligned workflow support, GLP-ready data handling |
| Brand | Anton Paar |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PoreMaster |
| Price | Upon Request |
| Pore Size Range | 30 nm – 600 µm |
| Pressure Range | 0.01 – 50 MPa |
| Measurement Accuracy | ≤ 0.5% |
| Brand | Anton Paar |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | POROMETER 3G |
| Pricing | Available Upon Request |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | PTD 100 Cone-Plate, Order Code 253764 |
| Pricing | Upon Request |
| Brand | Anton Paar |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Model | iSorb HP |
| Measurement Method | Static Volumetric Method |
| Temperature Range | 75 K to 773 K (-198 °C to 500 °C) |
| Pressure Range | 0.0005 bar to 200 bar (absolute) |
| Ultimate Vacuum | 1×10⁻⁹ mbar |
| Brand | Anton Paar |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Nova 600BET / 800BET / 600 / 800 |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Principle | Static Volumetric Gas Adsorption |
| Number of Analysis Stations | 4 |
| Specific Surface Area Range | ≥ 0.01 m²/g (no upper limit) |
| Pressure Range | 1×10⁻⁴ to 0.999 P/P₀ |
| Supported Theoretical Models | BET, Langmuir, t-plot, DFT (NLDFT/QSDFT), BJH, DH, DR, HK, SF |
| Repeatability | < 2% |
| Operating Temperature | 15–35 °C |
| Absolute Pressure Resolution | 1.2×10⁻⁴ Torr |
| Relative Pressure Resolution | 1.5×10⁻⁷ P/P₀ |
| Pore Diameter Range | 0.35–500 nm (0.35–1.1 nm with CO₂ at 273 K) |
| Minimum Detectable Pore Volume | 1.2×10⁻⁸ cm³ |
| Integrated Degassing Stations | 4 (programmable, up to 425 °C) |
| Dewar Capacity | 2 L (up to 40 h operation) |
| Dimensions (D×W×H) | 44 × 63 × 84 cm |
| Weight | 63 kg |
| Power Supply | AC 100–240 V, 50/60 Hz, max. 345 VA |
| Brand | Anton Paar |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Ultrapyc Series |
| Instrument Type | True Density Analyzer |
| Instrument Class | Benchtop Laboratory |
| Sample Type | Solids (bulk & granular), Powders, Pastes, Slurries, Foams |
| Density Accuracy | ≤0.015% |
| Display | 7-inch TFT WVGA (800 × 480 px) PCAP Touchscreen |
| Temperature Range | 3–60 °C |
| Minimum Sample Volume | 0.1 cm³ |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | RapidOxy 100 |
| Pricing | Available upon Request |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer | Anton Paar GmbH |
| Type | Imported Instrument |
| Model | RapidOxy |
| Pricing | Upon Request |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Model | RheolabQC |
| Instrument Type | Rotational Rheometer |
| Sample State | Liquid |
| Minimum Speed | 0.01 rpm |
| Maximum Speed | 1200 rpm |
| Torque Range | 0.20 mN·m to 75 mN·m |
| Shear Stress Range | 0.5–3×10⁴ Pa |
| Shear Rate Range | 10⁻²–4000 s⁻¹ |
| Viscosity Range | 1–10⁹ mPa·s (dependent on geometry) |
| Temperature Range | −20 °C to +180 °C |
| Angular Displacement Resolution | 2 µrad |
| Compliance | FDA 21 CFR Part 11, ISO 16520, ASTM D2196, D445, D1093 |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | RheolabQC |
| Instrument Type | Benchtop Rotational Viscometer |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 1 – 10⁹ mPa·s |
| Temperature Range | −20 to +180 °C |
| Speed Range | 0.01 – 1500 rpm |
| Torque Range | 0.25 – 75 mN·m |
| Shear Stress Range | 0.5 – 3×10⁴ Pa |
| Shear Rate Range | 0.01 – 4000 s⁻¹ |
| Angular Displacement Resolution | 2 µrad |
| Brand | Anton Paar |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Category | Imported |
| Model | RST 300 |
| Instrument Type | Micro/Nano Scratch Tester |
| Maximum Indentation Depth | 100 / 1000 µm |
| Effective Normal Load Range | 100 / 200 N |
| Load Resolution | 100 µN |
| Displacement Resolution | 0.05 / 0.5 nm |
| Maximum Friction Force | 100 / 200 N |
| Friction Resolution | 0.1 / 0.2 mN |
| Acoustic Emission Sensor | Center Frequency 150 kHz, Dynamic Range 65 dB, Max Gain 200,000× |
| Scratch Speed Range | 0.4 – 600 mm/min |
| Scratch Length | Up to 70 mm |
| In-situ Scratch Inspection Length | Up to 30 mm |
| Compliance | ASTM C1624, ISO 20502, ISO EN 1071 |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | SAXSpace |
| Instrument Type | X-ray Crystal Orientation Analyzer |
| Instrument Configuration | Benchtop |
| Minimum Scattering Vector Resolution | q<sub>min</sub> = 0.03 nm<sup>−1</sup> |
| q-Range | 0.03–40.7 nm<sup>−1</sup> |
| Detector Options | Mythen2 R (1D), EIGER R Series HPC (2D) |
| Sample Throughput | Up to 192 liquid samples per automated run |
| Temperature Control Range | −150 °C to +600 °C (±0.1 °C) |
| Environmental Control | Vacuum, air, inert gas, humidity, reactive gas (optional) |
| Measurement Time | <1 min to 30 min (typical) |
| Sample Forms | Liquids (quartz capillaries, SiN microfluidic cells), powders, viscous suspensions, thin films, solids under mechanical load |
| Specialized Modes | GISAXS, BioSAXS, time-resolved SAXS/WAXS, temperature- and humidity-scanned SWAXS |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Model | SAXSpace |
| Instrument Type | Small-Angle and Wide-Angle X-ray Scattering (SAXS/WAXS) System |
| q-Range | 0.03–49 nm⁻¹ |
| Real-Space Resolution Range | 0.13–200 nm |
| Maximum 2θ | 74° |
| X-ray Source | Sealed-tube (line or point focus) |
| Beam Size | 20 × 0.3 mm² (line), 0.3 × 0.3 mm² (point) |
| Operating Voltage | 40 kV |
| Operating Current | 50 mA |
| Minimum Sample Volume | 7 µL (liquid), few mg (solid) |
| Temperature Control Range | −150 to 300 °C (±0.1 °C stability) |
| Measurement Time | 1–60 min |
| Automation | Motorized optical alignment, in situ heating/cooling, liquid handling compatibility |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | SAXSpoint 500 |
| Instrument Type | Small-Angle X-ray Scattering (SAXS) System |
| q-Range | 0.02 nm⁻¹ to 43 nm⁻¹ |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | SAXSpoint 700 |
| Instrument Type | Small-Angle X-ray Scattering (SAXS) System |
| q-Range | 0.01 nm⁻¹ to 49.3 nm⁻¹ |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | SmartMelt 92/303 |
| Instrument Type | Rotational Rheometer |
| Sample Type | High-Viscosity |
| Sample State | Liquid |
| Motor Bearing | Precision Porous Carbon Air Bearing |
| Temperature Range | −150 °C to +400 °C |
| Frequency Range | 10⁻⁷ Hz to 628 rad/s (≈100 Hz) |
| Minimum Rotational Speed | 10⁻⁴ rpm |
| Maximum Torque | 215 mNm |
| Maximum Rotational Speed | 3000 rpm |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | SmartPave |
| Instrument Type | Rotational Rheometer |
| Sample Viscosity Range | High-Viscosity |
| Sample State | Liquid |
| Bearing Type | Air Bearing |
| Temperature Range | −160 °C to +1000 °C |
| Minimum Rotational Speed | 0 rpm |
| Frequency Range | 10⁻⁷ to 1256 rad/s |
| Maximum Rotational Speed | 3000 rpm |
| Maximum Torque | 215 mNm |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Model | SmartPave |
| Motor Bearing | Air Bearing |
| Minimum Rotational Speed | 0 rpm |
| Frequency Range | 10⁻⁷ – 628 rad/s |
| Maximum Rotational Speed | 3000 rpm |
| Maximum Torque | 200 mNm |
| Torque Resolution | < 0.1 nNm |
| Normal Force Range | 0.01 – 50 N |
| Normal Force Resolution | 1 mN |
| Temperature Range | −40 °C to +120 °C |
| Compliance Standards | AASHTO T315, T316, TP70, TP101, ASTM D7175, D4402, D7405, DIN EN 13302, DIN EN 14770 |
| Toolmaster™ | Yes |
| TruGap™ | Yes |
| T-Ready™ | Yes |
| Automatic Gap Control (AGC) | Yes |
| Peltier-based Dry Heating | Yes |
| Ethernet Interface | Yes |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Model | Snap 41 |
| Instrument Type | Portable Digital Alcohol Meter |
| Measurement Principle | U-tube Oscillation Density Method |
| Density Range (for Ethanol-Water Solutions) | 0–100 % v/v alcohol |
| Temperature Range (Measurement) | 5–30 °C (41–86 °F) with Automatic Temperature Compensation |
| Accuracy | ±0.2 % v/v alcohol, ±0.2 °C temperature |
| Repeatability (Std. Dev.) | ±0.1 % v/v alcohol, ±0.1 °C |
| Resolution | 0.01 % v/v alcohol, 0.1 °C |
| Sample Volume | 2 mL |
| Operating Ambient Temperature | 0–35 °C (32–95 °F) |
| Display | Digital LCD |
| Environmental Rating | IP54 |
| Power Supply | 3 × 1.5 V LR06 (AA) alkaline batteries |
| Dimensions | 245 × 103 × 126 mm (9.6 × 4.0 × 5.0 in) |
| Weight | 660 g (23.3 oz) |
| Supported Units | % v/v (at 15 °C or 20 °C), Proof, °Brix, °Plato, and 10 programmable custom units |
| Data Storage | 1024 measurements, 250 sample IDs, 30 user-defined methods |
| Connectivity | Bluetooth® (firmware updates only) |
| Compliance | ASTM D1152, ISO 3696, OIML R 22, EN 15733, EU Regulation (EC) No 1234/2007 Annex XI (alcohol determination in spirits) |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Model | Snap 51 |
| Instrument Type | Portable Digital Density Meter |
| Measurement Principle | U-tube Oscillation |
| Sample Volume | 2 mL |
| Density Range (for Ethanol-Water Mixtures) | 0–100 % v/v |
| Temperature Range (Measurement) | 0 °C to 40 °C (32 °F to 104 °F) with Automatic Temperature Compensation |
| Accuracy | ±0.1 % v/v (alcohol), ±0.1 °C (temperature) |
| Repeatability (Std. Dev.) | ±0.05 % v/v (alcohol), ±0.05 °C (temperature) |
| Reproducibility (Std. Dev.) | ±0.07 % v/v |
| Operating Ambient Temperature | −10 °C to +50 °C (14 °F to 122 °F) |
| Display | Capacitive Touchscreen |
| Data Storage | 1024 Results, 250 Sample IDs, 30 User-Programmable Methods |
| Connectivity | Bluetooth® 4.2, RFID Reader |
| Protection Rating | IP54 |
| Power Supply | 3 × 1.5 V LR06 AA Alkaline Batteries |
| Dimensions | 468 mm × 108 mm × 119 mm (18.4 in × 4.3 in × 4.7 in) |
| Weight | 860 g (30.3 oz) |
| Compliance | ISO 5725 (accuracy validation), ISO 15212-1 (alcohol determination in beverages), ASTM D4052 (density of liquids by digital density meter) |
| Brand | Anton Paar |
|---|---|
| Origin | Switzerland |
| Manufacturer | Anton Paar GmbH |
| Type | Imported Instrument |
| Model | STEP x01 |
| Instrument Category | Nanoindentation and Scratch Tester |
| Indenter Tip Material | Diamond |
| Base Platform | Modular Mechanical Surface Testing System |
| Maximum Load Capacity | Not specified in input |
| Compliance | GLP/GMP-ready architecture, ASTM E2546, ISO 14577, ISO 20502, USP <1089> compatible (inferred from platform class) |
| Vibration Isolation | Optional active damping table & acoustic enclosure |
| Microscopy | Dual-view optical microscope (20×–10,000× continuous zoom) |
| Positioning Accuracy | <1 µm over extended scan range |
| Automation Interface | Integrated for factory-floor QC integration |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | SurPASS 3 |
| Measurement Principle | Streaming Potential Method |
| pH Range | pH 2 – pH 12 |
| Temperature Range | 20 °C to 40 °C |
| Temperature Control | Integrated Peltier-based thermostating |
| Sample Compatibility | Flat solids (min. 20 mm × 10 mm, ≤2 mm thick |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | SVM 1001 |
| Instrument Type | Portable Rotational Kinematic Viscometer |
| Operating Environment | Ambient Temperature |
| Kinematic Viscosity Range | 0.3 mm²/s to 5000 mm²/s |
| Temperature Range | +15°C to +100°C (+59°F to +212°F), dual-temperature capability (one primary + one optional) |
| Temperature Resolution | 0.1°C |
| Temperature Accuracy | ±1°C |
| Viscosity Repeatability | 0.1% |
| Viscosity Reproducibility | 0.35% |
| Temperature Repeatability | 0.005°C |
| Temperature Reproducibility | 0.03°C across full range |
| Sample Volume | 1.5 mL (minimum), 5 mL (standard) |
| Solvent Volume | 1.5 mL (minimum), 6 mL (standard) |
| Throughput | up to 37 samples/hour (Ultra-Fast Mode) |
| Compliance | ASTM D445, ASTM D7042, ISO 23581, EN 16896 |
| Data Storage | 1,000 measurements |
| Display | 7″ capacitive touchscreen |
| Interface | 4 × USB (3 × Type-A, 1 × Type-B) |
| Power Supply | DC 24 V / 3 A |
| Environmental Conditions | +15°C to +35°C, ≤80% RH (non-condensing) |
| Certifications | CE, EMC EN 61326-1, Safety EN 61010-1, RoHS |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | SVM 3001 Cold Properties |
| Instrument Category | Multiparameter Physical Property Analyzer |
| Instrument Type | Benchtop Fixed System |
| Operating Environment | Ambient Temperature |
| Kinematic Viscosity Range | 0.2–30,000 mm²/s |
| Temperature Range | −60 °C to +100 °C |
| Compliance | AT516058 (B1), US10036695 (B2), CN105424556, EP2995928 (B1), AT516302 (B1), CN105628550 |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Category | Imported |
| Model | SVM 3001 |
| Instrument Type | Benchtop Fixed-Station Analyzer |
| Operating Environment | Ambient Temperature |
| Kinematic Viscosity Range | 0.2 to 30,000 mm²/s |
| Temperature Range | −60 °C to +135 °C |
| Compliance | AT516058 (B1), US10036695 (B2), CN105424556, EP2995928 (B1), AT516302 (B1), CN105628550 |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | SVM Series |
| Instrument Category | Kinematic Viscometer |
| Instrument Form Factor | Benchtop Fixed System |
| Operating Environment | Ambient Temperature |
| Kinematic Viscosity Range | 0.2 to 30,000 mm²/s |
| Temperature Control Range | 15 °C to 100 °C (standard) |
| Compliance | ASTM D7042, ASTM D445 (with bias correction), ISO 23581, EN 16896, ASTM D4052, ISO 12185, ASTM D2386, ASTM D2500, ASTM D396, D975, D1655, D3699, D6158, D6823, D7467 |
| Patents | AT516058 (B1), US10036695 (B2), CN105424556, EP2995928 (B1), AT516302 (B1), CN105628550 |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Model | SVM™ 2001 / SVM™ 3001 / SVM™ 4001 |
| Viscosity Range | 0.2 to 30,000 mm²/s |
| Temperature Range | +15 °C to +100 °C (SVM™ 2001 & 4001) |
| Density Range | 0.6 to 3.0 g/cm³ |
| Sample Volume | 1.5–6 mL |
| Compliance | ASTM D7042, ISO 12185, EN 16896, ASTM D4052, ISO 2909, ASTM D2270, ISO 91, ASTM D1250, ASTM D2161 |
| Cooling | Integrated Peltier (down to –20 °C) |
| Power | AC 100–240 V, 50–60 Hz, max. 250 VA |
| Dimensions (W × D × H) | 33 × 51 × 23.1 cm |
| Net Weight | 15.9–17.8 kg |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer | Anton Paar GmbH |
| Type | Imported Instrument |
| Model | TAG 300/500 |
| Detection Method | Closed-Cup (TAG) |
| Operation Mode | Fully Automatic |
| Sample Temperature Range | −35 °C to +130 °C |
| Ignition Source | Ceramic-Coated Electric Igniter |
| Compliant Standards | ASTM D56, ASTM D3941, ASTM D3934, ISO 1516, ISO 1523 |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | TAG500 |
| Detection Method | Closed-Cup (Tagliabue) |
| Operation Mode | Fully Automatic |
| Temperature Range | −30 °C to +130 °C |
| Ignition Source | Electronic (Encapsulated Hot-Wire) |
| Compliant Standards | ASTM D56, ASTM D3941, ASTM D3934, ISO 1516, ISO 1523 |