Campbell Scientific
Filter
Showing all 17 results
| Brand | Campbell Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AP200 |
| Pricing | Upon Request |
| Brand | Campbell Scientific |
|---|---|
| Origin | USA |
| Model | BlackGlobe-L |
| Operating Temperature Range | -50 °C to 100 °C |
| Measurement Range | -5 °C to 95 °C |
| Interchangeability Error | < ±0.2 °C (0–70 °C) |
| Polynomial Linearity Error | ±0.5 °C (-7 °C to 90 °C) |
| Maximum Cable Length | 305 m |
| Compatibility | All Campbell Scientific dataloggers except CR200X series |
| Sensor Type | Black Globe Thermometer for WBGT Index Calculation |
| Brand | Campbell Scientific |
|---|---|
| Origin | USA |
| Model | CPEC200 |
| Operating Temperature | −30 °C to +50 °C |
| Input Voltage | 10.5–16.0 Vdc |
| Typical Power Consumption | 12 W (max 35 W cold start) |
| System Dimensions | 52.1 × 44.5 × 29.7 cm |
| System Weight | 11.6 kg |
| Pump Module Flow Rate | 3–9 LPM (typ. 7 LPM) |
| Pump Pressure Range | 15–115 kPa |
| Valve Modules | 3-valve (zero, CO₂ span, H₂O span) or 6-valve (zero, four CO₂ spans, one H₂O span) |
| Data Storage | 2 GB CompactFlash card (≥60 days at 10 Hz) |
| Communication Interfaces | Ethernet, RS-232, short-haul modem, cellular, radio, satellite |
| Brand | Campbell Scientific |
|---|---|
| Origin | USA |
| Model | CPEC310 |
| Operating Temperature Range | −30 °C to +50 °C |
| Input Voltage | 10.5–16.0 V DC |
| Typical Power Consumption | 12 W |
| Max Power (Cold Start) | 35 W |
| Sample Cell Volume | 5.9 mL |
| Sample Residence Time | 50 ms @ 7 L/min |
| Frequency Response (−3 dB) | 5.8 Hz (CO₂/H₂O) |
| Cut-off Frequency (System) | 4.3 Hz |
| Pump Flow Rate | 3–9 L/min (Auto-Controlled, Default: 7 L/min) |
| Pressure Sensor Range | 15–115 kPa |
| Enclosure Dimensions (Control Box) | 54 × 44.5 × 29.7 cm |
| Weight (Control Box) | 15.36 kg (16.24 kg w/ CDM-A116) |
| Pump Module Dimensions | 35.6 × 29.2 × 13.5 cm |
| Weight (Pump Module) | 5.4 kg |
| Three-Valve Module Dimensions | 14.0 × 12.7 × 14.0 cm |
| Weight | 1.5 kg |
| Scrubber Module Heater Power | 8 W |
| Molecular Sieve Bead Size | 1.6–2.5 mm |
| Scrubber Cylinder Volume | 480 cm³ |
| Brand | Campbell Scientific |
|---|---|
| Model | CPEC310 |
| Origin | USA |
| System Type | Closed-path eddy covariance flux measurement system |
| Power Consumption | 12 W @ 25°C |
| Operating Temperature | −30 to +50°C |
| Operating Pressure Range | 70–106 kPa (expandable) |
| Measurement Frequency | 60 Hz |
| Output Rates | 5, 10, 12.5, or 20 Hz |
| Data Interfaces | SDM, RS-485, USB, analog (CO₂/H₂O only) |
| Total Mass | 15.36 kg |
| Warranty | 1 year from shipment |
| Gas Analyzer Sample Cell Volume | 5.9 mL |
| Cutoff Frequency | 4.3 Hz |
| CO₂ Accuracy | ±1% of reading |
| H₂O Accuracy | ±2% of reading |
| CO₂ Precision (RMS) | ≤0.15 µmol/mol |
| H₂O Precision (RMS) | ≤0.006 mmol/mol |
| CO₂ Zero Drift | ±0.3 µmol/mol/°C |
| H₂O Zero Drift | ±0.05 mmol/mol/°C |
| CO₂ Gain Drift | ±0.1% reading/°C |
| H₂O Gain Drift | ±0.3% reading/°C |
| Cross-sensitivity | CO₂ → H₂O: ±1.1×10⁻⁴ mol CO₂/mol H₂O |
| H₂O → CO₂ | ±0.1 mol H₂O/mol CO₂ |
| CSAT3A Path Lengths | Vertical 10.0 cm, Horizontal 5.8 cm |
| Wind Speed Range | uₓ/uᵧ ±65 m/s, u_z ±8 m/s |
| Wind Direction Range | 2.5°–357.5° (0–360° customizable) |
| Sonic Temperature Range | −50 to +60°C |
| Sonic Temperature Precision | 0.0025°C RMS |
| Brand | Campbell Scientific |
|---|---|
| Origin | USA |
| Model | CR1000X |
| Operating Temperature Range | –40 to +70 °C (standard), –55 to +85 °C (extended) |
| Analog Inputs | 16 single-ended or 8 differential |
| ADC Resolution | 24-bit |
| Max Scan Rate | 100 Hz |
| Communication Interfaces | Ethernet, USB Micro-B, RS-232/RS-485/RS-422, CPI, SDI-12, PakBus, Modbus TCP/RTU, DNP3, MQTT, NMEA 0183, I²C, SPI |
| Real-Time Clock Accuracy | ±3 min/year (±10 µs with optional GPS synchronization) |
| Power Supply | 10–18 VDC |
| Idle Current Draw | <1 mA @ 12 VDC |
| Dimensions | 23.8 × 10.1 × 6.2 cm |
| Weight | 0.86 kg |
| Data Storage | 4 MB SRAM + 72 MB flash + microSD slot (up to 16 GB) |
| Brand | Campbell Scientific |
|---|---|
| Origin | USA |
| Model | CR300 |
| Operating Temperature | -40 to +70 °C (standard, non-condensing) |
| Analog Inputs | 6 single-ended or 3 differential (software-configurable) |
| ADC Resolution | 24-bit |
| Analog Voltage Accuracy | ±(0.04% of reading + offset) at 0–40 °C |
| Pulse Counters | 8 (P_SW, P_LL, C1, C2, SE1–SE4) |
| Excitation Outputs | 2 (VX1, VX2) |
| Digital I/O | 7 configurable terminals (C1, C2, P_SW, SE1–SE4 |
| Communication Interfaces | USB Micro-B, RS-232, Ethernet (10/100BASE-T), PPP, RNDIS |
| Supported Protocols | PakBus, Modbus RTU/TCP, DNP3, SDI-12, TCP/IP, UDP, TLS v1.2, HTTP(S), FTP(S), SMTP/TLS, POP3/TLS, NTP, DHCP, DNS, ICMP, IPv4/IPv6 |
| Real-Time Clock Accuracy | ±1 minute per month (battery-backed) |
| Power Supply | 16–32 Vdc (CHG input) |
| Idle Current Draw | 1.5 mA @ 12 Vdc |
| Active Current Draw | 5 mA @ 12 Vdc (1 Hz scan, 1 analog measurement) |
| Enclosure Material | Powder-coated aluminum |
| Dimensions | 13.97 × 7.62 × 4.56 cm (5.5 × 3.0 × 1.8 in.) |
| Weight | 242–250 g (0.53–0.55 lb) |
| Onboard Memory | 80 MB flash (program/storage), 30 MB dedicated data storage |
| Programming Language | CRBasic (onboard BASIC-like language) |
| Brand | Campbell Scientific |
|---|---|
| Origin | USA |
| Model | CR3000 |
| Analog Input Channels | 28 single-ended (14 differential) |
| Analog Voltage Range | ±5000 mV |
| Analog Resolution | 0.33 µV |
| A/D Resolution | 16-bit |
| Maximum Scan Rate | 100 Hz |
| Pulse Count Channels | 4 |
| Switched Excitation Outputs | 4 voltage, 3 current |
| Control Ports | 3 SDM, 8 I/O |
| Communication Interfaces | CS I/O, RS-232, Ethernet (optional), RF radio (optional), CDMA/GPRS (optional), satellite (optional) |
| Supported Protocols | PakBus, Modbus RTU/ASCII/TCP, DNP3, FTP, HTTP, XML, POP3, SMTP, Telnet, NTP, NTCIP, SDI-12, SDM |
| Memory | 4 MB internal |
| Power Consumption | 2 mA (sleep), 3 mA (1 Hz), 10 mA (100 Hz) |
| Environmental Compliance | CE, EMC, GDT input protection |
| Real-Time Clock | Temperature-compensated, battery-backed |
| Data Storage Format | Tabular (timestamp + record number) |
| Operating Temperature | 0–40 °C |
| Software Compatibility | LoggerNet 3.4/4.0, PC400 1.2, ShortCut 2.2 |
| Brand | Campbell Scientific |
|---|---|
| Origin | USA |
| Model | CR6 |
| Processor | 32-bit ARM Cortex-M4 with hardware floating-point unit (100 MHz) |
| Internal Memory | 4 MB RAM, 6 MB flash for OS, 1 MB serial flash for program execution |
| MicroSD Card Support | Up to 16 GB |
| Real-Time Clock Accuracy | ±3 minutes/year (±10 µs with GPS synchronization) |
| USB Interface | USB 2.0 Full-Speed (12 Mbps), host/device capable |
| Ethernet | 10/100BASE-T |
| Communication Protocols | PakBus, SDI-12, SDM, RS-232, RS-485, CPI (Campbell Peripheral Interface) |
| U-Port Capabilities | Simultaneous analog/digital input, static vibration measurement (100 Hz – 6.5 kHz), bridge excitation (±2.5 V or ±2.5 mA), thermistor support (5 kΩ reference), frequency measurement up to 200 kHz |
| Analog Input | 12 single-ended or 6 differential channels |
| ranges | ±5000 mV, ±1000 mV, ±200 mV |
| Analog Output | 12-bit DAC (±2.5 V or ±2.5 mA) |
| Digital I/O | 12 configurable ports (3.3 V / 5 V logic) |
| Power Input | 12 V DC battery, solar (16–32 V DC), or USB |
| SW12V outputs | 2 × 12 V @ 1100 mA (20 °C) |
| Overvoltage Protection | All terminal strips include transient voltage suppression |
| Operating Temperature | −25 °C to +50 °C (extended range options available) |
| Dimensions | 20.3 × 10.2 × 6.1 cm |
| Weight | 0.42 kg |
| Compliance | CE, FCC Part 15 Class B, RoHS |
| Brand | Campbell Scientific |
|---|---|
| Origin | USA |
| Model | CR6 |
| Operating Temperature Range | -40 to +70°C (standard), -55 to +85°C (extended) |
| Analog Input Resolution | 24-bit ADC |
| Analog Voltage Accuracy | ±(0.04% of reading + offset) at 0–40°C |
| Input Channels | Up to 12 single-ended or 6 differential analog inputs |
| Communication Interfaces | Ethernet (10/100 RJ-45), USB Micro-B (virtual Ethernet & serial), RS-485, RS-422, SDI-12, CPI, CS I/O |
| Data Storage | 4 MB SRAM + 72 MB flash + microSD slot (up to 16 GB) |
| Power Supply | 10–18 Vdc (BAT), 16–32 Vdc (CHG) |
| Real-Time Clock Accuracy | ±3 min/year (GPS optional: ±10 µs) |
| Vibration Compensation | VSECT® spectral analysis for static vibrating-wire measurements |
| Enclosure | UV-stabilized TPE over impact-resistant polycarbonate (Recycling Code 7) |
| Dimensions | 21.0 × 10.2 × 5.6 cm |
| Weight | 0.42–0.52 kg |
| Brand | Campbell Scientific |
|---|---|
| Model | CR800 |
| Origin | USA |
| Differential Input Channels | 3 (6 single-ended) |
| Analog Input Resolution | 13-bit A/D |
| Scan Rate | Up to 100 Hz |
| Operating Temperature Range | 0 to 40 °C |
| Voltage Measurement Resolution | 0.33 µV |
| Sleep Mode Current Draw | ~0.6 mA |
| Active Current Draw (w/o RS-232) | 1–16 mA |
| Active Current Draw (w/ RS-232) | 17–28 mA |
| Communication Interfaces | 1 × CS I/O port, 1 × RS-232 serial port |
| Supported Protocols | PakBus®, Modbus RTU/ASCII, SDI-12, SDM, DNP3, FTP, HTTP, XML, POP3, SMTP, Telnet, NTCIP, NTP |
| Onboard Memory | 4 MB (data + program storage) |
| Data Format | Tabular ASCII |
| Operating System | PakBus OS |
| Compatible Software | LoggerNet, PC400, Short Cut |
| Optional Peripheral | CR1000KD handheld display |
| Brand | Campbell Scientific |
|---|---|
| Origin | USA |
| Model | CS320 |
| Sensor Type | Thermopile-based Total Solar Radiation Sensor |
| Calibration Uncertainty | ±5% |
| Measurement Range | 0–2000 W/m² |
| Repeatability | <1% |
| Long-term Drift | <2% per year |
| Non-linearity | <1% |
| Spectral Range | 385–2105 nm |
| Field of View | 180° (hemispherical) |
| Response Time | 2 s |
| Temperature Dependence | <5% over −15 to +45 °C |
| Operating Temperature | −50 to +50 °C |
| Heating Power | 0.2 W |
| Supply Voltage | 6–24 VDC |
| Current Consumption | 5 mA (during measurement) |
| Output Protocol | SDI-12 digital interface |
| Sensor Diameter | 34.3 mm |
| Height | 39.6 mm |
| Mass | 64.9 g |
| Brand | Campbell Scientific |
|---|---|
| Origin | USA |
| Model | CSAT3 |
| Measurement Principle | Ultrasonic Time-of-Flight (TOF) in Three Orthogonal Axes |
| Vertical Path Length | 10 cm |
| Output Frequency | Up to 50 Hz |
| Output Options | Analog (±5 V) and Digital (SDM, RS-232) |
| Operating Temperature Range | –30°C to +50°C |
| Ingress Protection | IP66-rated enclosure |
| Compliance | Designed for eddy covariance systems compliant with AmeriFlux, ICOS, and FLUXNET protocols |
| Integrated Clock | Internal temperature-compensated crystal oscillator (TCXO), ±1 ppm stability over operating range |
| Synchronization | SDM-compatible for precise multi-sensor timing alignment |
| Brand | Campbell Scientific |
|---|---|
| Origin | USA |
| Model | IRGASON |
| Measurement Principle | Simultaneous open-path infrared absorption (CO₂/H₂O) and ultrasonic anemometry (3D wind velocity, sonic temperature) |
| Output Frequency | Up to 60 Hz |
| Bandwidth | 20 Hz |
| Power Consumption | Low-power design compatible with solar power systems |
| Environmental Rating | IP65-rated enclosure |
| Calibration | Factory-calibrated for CO₂, H₂O, air temperature, barometric pressure, and sonic temperature across wide operational ranges |
| Diagnostic Capabilities | Comprehensive real-time diagnostics including signal strength, window contamination status, transducer health, and acoustic path integrity |
| Data Compatibility | Native support for Campbell Scientific CR series dataloggers (e.g., CR6, CR1000X) with full integration of setup, zero/span adjustment, and configuration via direct serial or SDI-12 interface |
| Rain Mitigation | Patented hydrophobic mesh + adaptive ultrasonic signal processing to maintain wind vector accuracy during precipitation |
| Optical Design | Angled optical windows with anti-water-adhesion geometry and tolerance for mild surface contamination |
| Thermal Management | Passive temperature compensation—no active heater required |
| Brand | Campbell Scientific |
|---|---|
| Model | IRGASON |
| Origin | USA |
| Type | Integrated Open-Path Eddy Covariance System |
| Operating Temperature | −30 to +50 °C |
| Operating Pressure | 70–106 kPa (expandable) |
| Supply Voltage | 10–16 VDC |
| Average Power Consumption | 5 W @ 25 °C |
| Measurement Frequency | 60 Hz |
| Output Bandwidth Options | 5, 10, 12.5, 20 Hz |
| Data Output Interfaces | SDM, RS-485, USB, Analog (CO₂/H₂O only) |
| Gas Path Length | 15.37 cm |
| CO₂ Accuracy | ±1% of reading |
| H₂O Accuracy | ±2% of reading |
| CO₂ Precision (RMS) | 0.2 mg/m³ (0.15 µmol/mol) |
| H₂O Precision (RMS) | 0.004 g/m³ (0.006 mmol/mol) |
| CO₂ Calibration Range | 0–1,000 µmol/mol (extendable to 3,000 µmol/mol) |
| H₂O Calibration Range | 0–72 mmol/mol (at 38 °C dew point) |
| CO₂ Temperature-Dependent Gain Drift | ±0.1% reading/°C |
| H₂O Temperature-Dependent Gain Drift | ±0.3% reading/°C |
| CO₂–H₂O Cross-Sensitivity | ±1.1×10⁻⁴ mol CO₂/mol H₂O |
| H₂O–CO₂ Cross-Sensitivity | ±0.1 mol H₂O/mol CO₂ |
| Ultrasonic Anemometer Path Lengths | Vertical 10.0 cm, Horizontal 5.8 cm |
| Wind Speed Range (uₓ/uᵧ) | ±65 m/s |
| Wind Speed Range (u_z) | ±8 m/s |
| Wind Direction Range | 2.5°–357.5° (0–360° customizable) |
| Ultrasonic Temperature Range | −50 to +60 °C |
| uₓ/uᵧ Offset Error | <±8.0 cm/s |
| u_z Offset Error | <±4.0 cm/s |
| Wind Direction Offset Error | ±0.7° |
| Gain Error (at ±5° tilt) | <±2% reading |
| uₓ/uᵧ Precision (RMS) | 1 mm/s |
| u_z Precision (RMS) | 0.5 mm/s |
| Wind Direction Precision (1 m/s wind) | 0.06° |
| Ultrasonic Temperature Precision | 0.0025 °C |
| Total Mass | 6 kg |
| Warranty | 3 years from factory shipment or 17,500 operational hours, whichever occurs first |
| Brand | Campbell Scientific |
|---|---|
| Origin | USA |
| Model | SoilVUE10 |
| Measurement Principle | Time-Domain Reflectometry (TDR) |
| Output Protocol | SDI-12 v1.4 |
| Depth Options | 0.5 m (6 depth layers) or 1.0 m (9 depth layers) |
| Diameter | 5.2 cm (body), 5.8 cm (with threads) |
| Length | 0.55 m (0.5 m version) / 1.05 m (1.0 m version) |
| Weight | 1.9 kg / 3.6 kg |
| Operating Temperature | −30 °C to +40 °C |
| Volumetric Water Content Accuracy | ±1.5% (for most mineral soils) |
| Electrical Conductivity Range | 0–10 dS/m |
| Relative Permittivity Range | 1–80 |
| Relative Permittivity Accuracy | ±1 unit |
| Temperature Accuracy | ±0.15 °C |
| Power | ~64 mA dynamic / ~2.5 mA quiescent @ 12 VDC |
| IP Rating | IP67 (M12 connector) |
| Compliance | SDI-12 v1.4, RoHS, CE |
| Brand | Campbell Scientific |
|---|---|
| Model | TM320 |
| Origin | USA |
| Temperature Range | −20 to 70 °C |
| Temperature Accuracy | ±0.5 °C |
| Relative Humidity Range | 0 to 95 %RH (non-condensing) |
| RH Accuracy | ±2 %RH |
| Operating Environment | −20 to 70 °C |
| Power Supply | 4 × AA alkaline batteries or optional AC adapter |
| Memory Capacity | 32,000 data points |
| Sampling Interval | Adjustable from 1 second to 24 hours (in 10-second increments) |
| Alarm Function | User-configurable high/low limits with audible alert |
| Housing Material | Polycarbonate |
| Dimensions | 10.2 × 7.7 × 3.9 cm |
| Weight | 255 g (9 oz) |
| Certifications | CE |