Fuland (CSFriend)
Filter
Showing all 8 results
| Brand | Fuland (csfriend) |
|---|---|
| Origin | Hunan, China |
| Model | FDY-0808 |
| Application Category | Laboratory Instrument for EV Thermal Management Fluid Evaluation |
| Compliance Standard | GB/T 29743.2 Annex C |
| Temperature Range | 0–100 °C (±1 °C accuracy) |
| Flow Rate | ≥30 L/min (adjustable, resolution 0.1 L/min) |
| Pressure Range | 0–500 kPa |
| Maximum Runtime | 9999 h (programmable, supports 1064 h continuous test cycles) |
| Data Storage Capacity | >200 test records |
| Pump Type | High-Temperature Automotive Electronic Water Pump (head ≥11 m, inlet/outlet diameter 20 mm) |
| Test Components | Aluminum Battery Cold Plate (≥1 m²), Aluminum Motor Housing with Integrated Cooling Channels, Aluminum Electronic Control Cooling Module |
| Fluid Path Material | Stainless Steel Fittings with Visual Observation Window |
| Thermal Insulation | Multi-layer External Jacket (reduces surface temperature & external thermal radiation) |
| Brand | FuLand / csfriend |
|---|---|
| Origin | Hunan, China |
| Model | Compliant with GB/T 5096 |
| Temperature Range | Ambient to 150 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Heating Power | 1200 W |
| Display | LCD (English/Chinese) |
| Test Stations | 6 |
| Diagnostic Function | Built-in Self-Diagnosis & Auto-Tuning Capability |
| Oxygen Bomb Storage Compartment | Integrated |
| Brand | FuLand / csfriend |
|---|---|
| Measurement Range | 2–100 mN/m (for insulating oils) |
| Sensitivity | 0.1 mN/m |
| Repeatability | ±0.3% |
| Accuracy | ±0.1 mN/m |
| Resolution | 0.1 mN/m |
| Power Consumption | 20 VA |
| Operating Temperature | 10–30 °C (typical at 25 °C) |
| Relative Humidity | 20–75 %RH |
| Supply Voltage | AC 220 V ±5%, 50 Hz |
| Net Weight | 15 kg |
| Microcontroller Architecture | High-Capacity Embedded MCU |
| Display | Full-Color LCD Touchscreen Interface |
| Data Handling | Auto-calibration via multi-point linear regression (mg = f(Δ-result)), real-time clock, non-volatile memory backup, auto-lift mechanism, integrated thermal printer |
| Brand | Fuland (CSFriend) |
|---|---|
| Model | FDH-8461 |
| Application | HTHS viscosity measurement of lubricating oils |
| Standard Compliance | ASTM D5481, SH/T 0703 |
| Temperature Range | Ambient to 150 °C |
| HTHS Viscosity Range | 0.5–8 mPa·s at 150 °C |
| Pressure Control Range | 3.5–35 kgf/cm² |
| Sample Volume | 10 mL |
| Pressure Display | Digital pressure gauge |
| Time Measurement | Digital timer |
| Control Method | Integrated microprocessor-based PID temperature & pressure regulation |
| Power Supply | AC 220 V, 50 Hz |
| Safety | FTC thermal cut-off circuit |
| Sample Handling | Individual stopcock valve per capillary cell |
| Brand | Fuland (csfriend) |
|---|---|
| Origin | Hunan, China |
| Model | FDQ-0201 |
| Power Supply | 220 V ±10%, 50 Hz ±5% |
| Max. Power Consumption | <3 kW |
| Temperature Range | 20–80 °C |
| Temperature Control Accuracy | ±0.2 °C |
| Rotation Speed | 40–150 rpm ±2 rpm |
| Number of Coupon Stations | 10 |
| Dimensions (L×W×H) | 1000 × 500 × 1050 mm |
| Weight | 90 kg |
| Brand | Fuland (csfriend) |
|---|---|
| Model | FDR-4171 |
| Origin | Hunan, China |
| Compliance Standard | GB/T 30963 |
| Temperature Control Method | Microcomputer-controlled bath & sample temperature |
| Stirring Method | Automatic mechanical stirring |
| Data Output | On-screen real-time crystallization curve + thermal profile display, storage and thermal printer output |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Rated Power | 1 kW |
| Operating Environment | 0–45 °C, RH <80% |
| Heating Element | Dry-burn-resistant electric heating tube |
| Brand | FuLand / csfriend |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | FDS-0401 |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Input Power | 800 W |
| Refrigeration Output | 2 × 400 W = 800 W |
| Ambient Temperature Range | Room Temperature to +30 °C |
| Operating Temperature Range | 20 °C to –70 °C |
| Refrigerants | R13 & R502 |
| Cooling Method | Air-Cooled |
| Temperature Control System | PID-Based Digital Thermostat |
| Sample Interface | Quick-Connect Fittings for LPG Cylinders and N₂ Purge Lines |
| Compressor Type | Imported High-Stability Unit |
| Brand | FuLand / csfriend |
|---|---|
| Origin | Hunan, China |
| Model | FDT-1102 |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Bath Temperatures | 24 °C and 93.5 °C |
| Heater Power | 2500 W (93.5 °C bath), 800 W (24 °C bath) |
| Temperature Sensor | PT100 platinum resistance thermometer |
| Air Diffuser Disc Diameter | 25.4 mm ±0.02 mm |
| Air Permeability of Diffuser | 3000–6000 mL/min at 2.4 kPa (250 mm H₂O) |
| Test Cylinder | 1000 mL calibrated glass cylinder |
| Integrated Air Supply System | Built-in eco-friendly diaphragm air pump |
| Cooling System | Integrated refrigeration unit for low-temperature testing |
| Timing Control | Digital electronic timer with auto-start/stop logic |