Generic
Filter
Showing 4801–4830 of 5675 results
| Key Specifications | Temperature Range: -65°C to +180°C (typical) |
|---|---|
| Transfer Time | ≤15 s (dual-compartment), ≤30 s (three-zone) |
| Recovery Time | ≤5 min (standard load) |
| Internal Volume | 100–1000 L (configurable) |
| Cooling Method | Dual-stage cascade refrigeration with water-cooled condensers |
| Compliance | GB/T 2423.1–2, GB/T 2423.22, GJB 150.5, IEC 60068-2-14, MIL-STD-810H Method 503.5, ASTM D648, ISO 11359-2 |
| Power Supply | 380 VAC ±10%, 3-phase, 50/60 Hz |
| Water Cooling Requirement | External cooling tower (10 m³/h flow rate, 32°C max inlet temperature) |
| Control System | PID-based programmable controller with Ethernet interface |
| Data Logging | Built-in memory + optional USB/RS485 export |
| Safety Features | Over-temperature, over-pressure, compressor high/low pressure, phase failure, door interlock |
| Key | Temperature Range: -40 to 100°C |
|---|---|
| Humidity Range | 20–98% RH |
| Temperature Uniformity | ±1°C |
| Humidity Uniformity | ±5% RH |
| Door Configuration | Dual-front & rear access doors |
| Heating Load Capacity | Customizable per user specification |
| Cooling System | Air-cooled, single-stage compressor (for -20°C base) / dual-stage compressor (for -40°C to -70°C operation) |
| Ramp Rates | ~4.0°C/min (heating), ~1.0°C/min (cooling) |
| Construction | Interior and exterior walls in brushed SUS304 stainless steel |
| Viewing Window | Low-condensation coated electrothermal glass |
| Control System | PLC-based programmable controller with color touchscreen HMI |
| Compliance | Designed to support IEC 60068-2-14, MIL-STD-810H Method 503.5, JESD22-A104, and JEDEC J-STD-020 for lead-free solder process validation |
| Key | Temperature Range Options: -20°C to 150°C |
|---|---|
| Humidity Range (optional) | 20–98% RH |
| Temperature Uniformity | ≤ ±2°C |
| Temperature Stability | ≤ ±0.5°C |
| Humidity Deviation | +2 / −3% RH |
| Heating Rate | 1.0–3.0°C/min |
| Cooling Rate | 0.7–1.0°C/min |
| Control System | Programmable Touchscreen Controller (English/Chinese UI) |
| Temperature Setpoint Accuracy | ±0.1°C |
| Humidity Setpoint Accuracy | ±1% RH |
| Sensor Type | PT100 Platinum Resistance Thermometer |
| Heating Method | Independent Nickel-Chromium Alloy Heaters |
| Humidification | Stainless Steel Surface Evaporation System |
| Dehumidification | Evaporator Coil Dew-Point Contact Method |
| Exterior Material | Cold-Rolled Carbon Steel with Phosphating & Electrostatic Powder Coating OR SUS304 Brushed Stainless Steel |
| Interior Material | SUS304 Mirror-Finish Stainless Steel |
| Insulation | Polyurethane Rigid Foam + Ultra-Fine Glass Fiber |
| Door Seal | Dual-Layer High/Low-Temperature Resistant Silicone Rubber |
| Power Supply | AC 380V ±10%, 50 ±0.5 Hz, 3-Phase 5-Wire |
| Refrigeration | Twin-Stage Cascade Air-Cooled System with Imported Hermetic Compressors (France) |
| Key Features | Two-zone (hot/cold chambers with basket transfer) or three-zone (hot chamber / cold chamber / test chamber) architecture |
|---|---|
| Temperature Range | Hot Zone up to +200 °C |
| Test Zone | −65 °C to +150 °C |
| Temperature Transition Time | ≤5 min (typical recovery) |
| Uniformity | ±2.0 °C |
| Control Accuracy | ±0.5 °C |
| Refrigeration System | Dual-stage cascade refrigeration with imported semi-hermetic compressors (Germany) |
| Refrigerants | R404A / R23 (ozone-friendly) |
| Insulation | High-density fire-retardant PU foam |
| Interior | Mirror-finish SUS304 stainless steel |
| Exterior | SUS304 or powder-coated steel |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz, 3-phase 5-wire |
| Cooling Water Requirement | External cooling tower (10 m³/h capacity required) |
| Compliance | GB/T 2423.1–2001, GB/T 2423.2–2001, GB/T 2423.22–2002, GJB 150.5–86, IEC 60068-2-14, EIA-364-32, QC/T 17–92, SJ/T 10186–91 & 10187–91 |
| Customizable Internal Dimensions | 40×35×30 cm to 70×60×60 cm (W×H×D) |
| Key | Temperature Range Options: −70°C to +150°C |
|---|---|
| Humidity Range | 30–98% RH |
| Humidity Deviation | +2 to −3% RH |
| Temperature Fluctuation | ±0.5°C |
| Temperature Uniformity | ≤±2°C |
| Avg. Ramp Rate | 0.7–1.0°C/min |
| Timer Setting Range | 0–9999 h |
| Power Supply | AC 380 V |
| Internal Material | SUS304 Stainless Steel Mirror Finish |
| External Material | A3 Steel with Powder Coating |
| Observation Window | Embedded Heated Tempered Glass with LED Illumination |
| Test Port | Ø50 mm |
| Compliance | Designed to Support ASTM D5229, ISO 16750-4, IEC 60068-2-14, MIL-STD-810H Thermal Shock Protocols |
| Key | Temperature Range (Hot Zone): RT to +150 °C (unloaded) |
|---|---|
| Temperature Range (Cold Zone) | RT to −20 °C (unloaded) |
| Temperature Fluctuation | ±1 °C |
| Temperature Uniformity | ±3 °C |
| Ramp Rate (Heating) | ≤25 min (RT → +150 °C, average) |
| Ramp Rate (Cooling) | ≤15 min (RT → −20 °C, average) |
| Low-Temperature Limit | ≤−25 °C |
| Thermal Shock Transition Range | +150 °C ↔ −20 °C |
| Load Capacity | ≤30 kg |
| Temperature Recovery Time | ≤5 min |
| Basket Transfer Time | ≤15 s |
| Power Rating | 13–20 kW (model-dependent) |
| Refrigerant | HFC-based, dual-stage cascade cryogenic system |
| Key | Temperature Range: −70 °C to +150 °C |
|---|---|
| Humidity Range | 20–98% RH |
| Temp. Uniformity | ±1.5 °C |
| Humidity Uniformity | ±3% RH |
| Temp. Stability | ±0.5 °C |
| Humidity Stability | ±2% RH |
| Internal Dimensions (W×H×D) | 600 × 850 × 800 mm |
| External Dimensions (W×H×D) | 1200 × 1700 × 1300 mm |
| Construction | Interior – SUS#304 stainless steel (1 mm thick) |
| Insulation | Rigid polyurethane foam + fiberglass wool |
| Refrigeration System | Hermetic compressor (Tecumseh or equivalent), eco-friendly refrigerant (R404A/R507), air-cooled condenser, fin-tube evaporator, solenoid valve, dryer filter, capillary tube |
| Heating System | U-shaped finned tubular heaters |
| Control System | TEMI880 color touchscreen programmable controller (LCD, bilingual English/Chinese interface, multi-segment PID control, real-time curve display, alarm logging, data export via USB) |
| Power Supply | 3-phase 5-wire 380 VAC ±10% or 2-phase 3-wire 220 VAC ±10% |
| Standard Accessories | Dual-pane tempered glass observation window, φ50 mm test port (left side), two adjustable sample racks, interior fluorescent lighting, four casters with brakes, built-in humidifier tank |
| Safety Protections | Compressor overheat/overcurrent/high-pressure protection, heater dry-run prevention, chamber overtemperature alarm, low-water level detection |
| Key Features | Programmable 7-inch color touchscreen controller (Chinese UI) |
|---|---|
| Temperature Range | -30°C to +150°C / -50°C to +150°C / -65°C to +150°C |
| Temperature Uniformity | ±2.0°C |
| Temperature Stability | ±0.5°C |
| Heating Rate | up to 20°C/min (non-linear average) |
| Cooling Rates | 3 / 5 / 10 / 15°C/min (non-linear average) |
| Refrigeration System | Semi-hermetic or hermetic compressors (European/American origin) |
| Refrigerants | R404A, R23 |
| Insulation | High-density polyurethane foam or ultra-fine glass wool |
| Interior Material | SUS304/2B stainless steel with radius-corner design |
| Exterior Finish | Powder-coated cold-rolled steel |
| Safety Protections | Over-temperature, over-pressure, phase-loss, motor overload, earth leakage, compressor high-temp/overcurrent, grounding terminal |
| Compliance | GB/T 2423.1–1989, GB/T 2423.2–1989, GB/T 2423.34–1993, IEC 60068-2-30 |
| Key | Temperature Range: −70 °C to +150 °C |
|---|---|
| Heating Rate (−20 °C → +100 °C) | ≈35 min |
| Cooling Rate (20 °C → −70 °C) | ≈90 min |
| Inner Chamber Material | 1 mm SUS#304 Stainless Steel |
| Outer Chamber Material | Powder-Coated Cold-Rolled Steel or SUS#304 Brushed Stainless Steel |
| Insulation | Rigid Polyurethane Foam + Glass Wool |
| Refrigeration System | Hermetic Compressor (Tecumseh/France) with Eco-Friendly Refrigerant (R404A/R507) |
| Controller | TEMI880 Color Touchscreen Programmable Temperature/Humidity Controller (LCD, Bilingual English/Chinese Interface, Multi-PID, Curve Monitoring, Alarm Logging) |
| Power Supply | 3φ5W 380 VAC ±10% or 2φ3W 220 VAC ±10% |
| Standard Accessories | Double-Layer Tempered Glass Viewing Window, φ50 mm Cable Port (Left Side), Two Adjustable Sample Racks, Fluorescent Interior Lamp, Four Casters, Integrated Humidifier Tank |
| Safety Protections | Compressor Overheat/Overcurrent/High-Pressure Protection, Dry-Run Prevention for Heaters & Humidifiers, Chamber Over-Temperature Cut-off, Low-Water-Level Alarm |
| Compliance | Designed per IEC 60068-2-14 (Environmental Testing – Part 2-14: Tests – Test N: Change of Temperature) and ASTM D5229/D5229M (Standard Test Method for Moisture Absorption Properties of Polymer Matrix Composite Materials) — Structural and operational architecture supports GLP/GMP-aligned validation protocols. |
| Key Features | Three-zone design (high-temp chamber, low-temp chamber, test chamber) |
|---|---|
| Inner chamber wall thickness | 1.0–1.2 mm standard |
| Standard internal volumes | 50 L to 1000 L |
| Typical temperature ranges | −40 °C to +150 °C, −55 °C to +150 °C, or −70 °C to +150 °C |
| Key | Temperature Range (High Zone): +150°C to +200°C |
|---|---|
| Temperature Range (Low Zone) | -70°C to -40°C |
| Transition Time (Typical) | ≤15 s (5℃ to -40℃) |
| Test Zone Stability | ±0.5°C |
| Control System | PLC-based with 302×240-dot LCD HMI (Bilingual English/Chinese) |
| Program Storage | 100 user-defined profiles, up to 9999 cycles per profile |
| Timing Resolution | 1 min (adjustable to 1 sec) |
| Communication Interface | RS-232C, optional RS-485/Ethernet |
| Compliance | GB/T 2423.1–2001, GB/T 2423.2–2001, GB/T 2423.22–1989, GJB 150.5–1986, GJB 360.7–1987, IEC 60068-2-14 (Test N) |
| Key Temperature Range Options | A: -20°C to 200°C |
|---|---|
| B | -40°C to 200°C |
| C | -60°C to 200°C |
| Temperature Stability | ≤ ±2°C in High/Low Temp Zones |
| Thermal Transition Performance | -40°C ↔ 85°C in ≤ 11 min (including dwell) |
| Heat Storage Zone Ramp | Ambient to +100°C in ~30 min |
| Cold Storage Zone Ramp | Ambient to -50°C in ~90 min |
| Test Zone Dimensions | 450 mm (W) × 300 mm (H) × 300 mm (D) |
| Test Load Capacity | 20 kg / 30 kg / 50 kg options |
| Construction | Interior & Exterior Panels – SUS#304 Stainless Steel |
| Insulation | High-Density Fire-Retardant PU Foam + Advanced K-Type Sweat-Prevention Ducting |
| Cooling System | Dual-Stage Cryogenic Refrigeration with Eco-Friendly Refrigerant (R-404A/R-23 blend), Plate-Type Heat Exchangers, Automatic/Manual Defrost Circuits |
| Control System | 7-inch Full-Color LCD Touchscreen Microprocessor Controller with RS-232/RS-485 Interface |
| Compliance | Designed to meet IEC 60068-2-14, MIL-STD-810H Method 503.5, JIS C 0025, CNS 12227, and ISO 16750-4 environmental stress screening requirements |
| Safety Protections | Independent Over-Temperature Cutout (Test Chamber), Compressor High-Pressure & Low-Oil-Pressure Protection, Heating Element Overload/Short-Circuit Protection, Phase Failure & Undervoltage Detection, Ground Fault Monitoring |
| Key | Internal Chamber Dimensions: 46×46×46 cm |
|---|---|
| High-Temperature Zone Range | Ambient to +150 °C |
| Low-Temperature Zone Range | Ambient to −60 °C |
| Average Ramp Rate | 1.5 °C/min |
| Temperature Uniformity | ±0.5 °C |
| Temperature Accuracy | ±2 °C |
| Transfer Time (Cold ↔ Hot) | <10 s |
| Temperature Recovery Time | <5 min |
| Actuation Method | Pneumatic Cylinder-Based Basket/Tray Transfer |
| Construction | Exterior & Interior Liner — SUS304 Stainless Steel |
| Refrigeration System | Dual-Stage Compound Compressor (Air-Cooled or Water-Cooled), Imported Tecumseh (France) Compressor Units, Eco-Friendly Refrigerant (R404A/R507) |
| Control System | Programmable LCD Controller (320 × 240 Dots), Bilingual (English/Chinese) Interface |
| Max. Program Storage | 100 Sets |
| Max. Cycles per Program | 9999 |
| Max. Segment Duration | 999 h 59 min |
| Communication | RS-232C Port for PC Integration, Data Logging & Remote Editing |
| Dynamic I/O | Two Time-Signal Relays |
| Power Rating | 7.5 kW / 12 kW / 15 kW / 26 kW |
| Electrical Supply | AC 380 V, 50 Hz, 3-Phase 4-Wire |
| Compliance | GB/T 2423.22, GJB 150.5A, IEC 60068-2-14, MIL-STD-810H Method 503.5 |
| Application Scope | Static (non-moving) specimen testing only |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 01STHE□ |
| Pricing | Available Upon Request |
| Accuracy | ±1 °C below 100 °C |
| Compliance | BS EN ISO 9001 certified |
| Dimensions | 12 × 13 mm per strip |
| Pack Size | 50 strips per pack |
| Format | Vertical self-adhesive format with dual-scale (°C and °F) markings |
| Temperature Range Options | 29–290 °C (discrete points: 29, 33, 34, 37, 40, 42, 43, 44, 46, 49, 54, 60, 62, 65, 71, 77, 82, 88, 93, 99, 104, 110, 116, 121, 127, 132, 138, 143, 149, 154, 160, 166, 171, 177, 182, 188, 193, 199, 204, 210, 216, 224, 232, 241, 249, 254, 260, 280, 290 °C) |
| Chemical Resistance | Oil-resistant and water-resistant |
| Toxicity | Non-hazardous, non-toxic formulation |
| Indication Mechanism | Irreversible thermochromic color transition (white → black) |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Thermecmaster-MD |
| Price | USD 1.95M (FOB Yokohama) |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Thermecmaster-TS |
| Price | USD 940,000 (FOB Yokohama) |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Thermecmaster-W |
| Price | USD 1.4M (FOB Yokohama) |
| Sample Geometry | Cylindrical Ø8–10 mm × L140–200 mm |
| Heating System | Dual-mode — High-frequency induction (15 kW, 100 kHz) + Resistive direct-current heating (75 kVA, 50–60 Hz) |
| Restraint Actuation | Hydraulic servo-controlled load frame (100 kN max force, ±5.5 mm displacement range) |
| Thermal Ramp Rates | Heating up to 500 °C/s |
| Cooling Rate | Up to 60 °C/s (800–500 °C range, helium gas quenching) |
| Control Modes | Load control, displacement control, and load–displacement hybrid switching |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Thermecmaster-Z, 100 kN, 1000 mm/s |
| Max. Load Capacity | 100 kN |
| Heating Range | RT to 1600 °C |
| Max. Heating Rate | 70 °C/s (tensile specimen) |
| Max. Cooling Rate | 300 °C/s (water quench, tensile) |
| Temperature Control Accuracy | ±3 °C (static) |
| Uniform Temperature Zone | ±5 mm from specimen center (all modes) |
| Atmosphere Control | Vacuum (≤1.3×10⁻² Pa), N₂, Ar, He |
| Cooling Media | Inert gas or deionized water |
| Loading Speed Range | 1×10⁻³ to 1×10³ mm/s |
| Stroke | 100 mm |
| Control Modes | Displacement, Load, and Hybrid (switching time: 1 ms) |
| Data Acquisition | Synchronized LED-based non-contact dilatometry, real-time load/displacement/temperature logging |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Thermemcmastor-Z, 300 kN, 1000 mm/s |
| Max. Load | 300 kN |
| Max. Strain Rate | 1 × 10⁻³ to 1 × 10³ mm/s |
| Heating Methods | High-Frequency (HF) Induction + Low-Frequency (LF) Direct Resistance |
| Temperature Range | RT to 1600 °C (material-dependent) |
| Cooling Media | He, Ar, N₂, or Water |
| Max. Cooling Rate | 500 °C/s (water, φ8×12 mm specimen) |
| Expansion Measurement | Non-contact GaN LED shadow method, ±3 µm accuracy |
| Atmosphere Control | Vacuum (≤5 × 10⁻² Torr), inert gas, or ambient air |
| Control Precision | ±0.1 mm (displacement), ±3 °C (temperature), ±2 kgf/mm² (load) |
| Origin | Finland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Thermo Fisher AutoAnalyzer Series |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AMQAX1000 |
| Detection Time | <10 sec |
| Cell Concentration Range | 1×10⁴–1×10⁷ cells/mL |
| Sample Volume | 10 µL |
| Throughput | 100,000 samples/year |
| Detectable Particle Size | 4–60 µm |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Q5000IR, Q500, Q50 |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model Series | Thermo Fisher Heratherm OGS, OMS, OGH, OGH-S |
| Temperature Range | 50–250 °C (OGS/OMS) / 50–330 °C (OGH/OGH-S) |
| Convection Types | Natural Convection (OGS/OGH) & Forced Air Convection (OMS/OGH-S) |
| Chamber Volume | 61–179 L |
| Temperature Uniformity (at 150 °C) | ±1.3–±4.0 °C |
| Temperature Stability (over time) | ±0.2–±0.4 °C |
| Chamber Material | Electropolished Stainless Steel (AISI 304), Radius-Corner Design |
| Control System | Microprocessor-Based Touch-Sensitive Keypad with Vacuum Fluorescent Display (VFD) |
| Safety Features | Dual Independent Over-Temperature Protection, Optional Sample Temperature Probe, Door Interlock Alarm, Programmable Auto-Shutdown |
| Origin | Assembled in Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (China) |
| Model | MULTISKAN ASCENT |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Custom Configuration Available |
| Pricing | Upon Request |
| Instrument Type | Radiation Survey Meter / Dose Rate Meter |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Veriti Pro |
| Price Range | USD 42,000–70,000 |
| Instrument Category | Gradient-enabled Dual-Block PCR System |
| Sample Throughput | 96-well (0.2 mL format) |
| Maximum Ramp Rate | 10 °C/s |
| Temperature Accuracy | ±0.1 °C at 95 °C |
| Well-to-Well Uniformity | ≤0.3 °C across full block |