Generic
Filter
Showing 4891–4920 of 5668 results
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model Series | TSP P1500 (Quaternary Pump), UV1000 (Variable Wavelength Detector), AS3000 (Autosampler) |
| Compliance | CE, UL, RoHS |
| Operating Pressure Range | Up to 400 bar |
| Flow Rate Range | 0.001–10.000 mL/min |
| Wavelength Range (UV1000) | 190–700 nm |
| Detection Limit (UV1000) | < 5 × 10⁻⁹ g/mL (caffeine, 254 nm) |
| Injection Volume Range (AS3000) | 0.1–100 µL |
| Precision (RSD) | ≤ 0.3% for retention time, ≤ 0.5% for peak area |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model Series | P4000, AS 3000, UV 1000 |
| Compliance | CE, UL, RoHS |
| Flow Rate Range | 0.001–10.000 mL/min |
| Pressure Rating | Up to 400 bar |
| Gradient Accuracy | ≤0.2% RSD |
| Pulse Dampening | Active electronic compensation |
| Solvent Compatibility | HPLC-grade aqueous/organic solvents (including THF, DCM, DMF) |
| Communication Interface | RS-232, CAN bus, optional Ethernet (via TSP Control Hub) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TSQ Quantum GC |
| Price Range | USD 135,000 – 205,000 (FOB) |
| Instrument Type | Triple Quadrupole Mass Spectrometer |
| Chromatography Configuration | Standalone GC-Coupled System |
| Ionization Modes | Electron Ionization (EI) and Chemical Ionization (CI), switchable without venting |
| Collision Cell | Zero-Crosstalk RF-Only Quadrupole Collision Cell |
| Acquisition Modes | High-Selectivity SRM (H-SRM), Quantitative Enhanced Data-dependent MS/MS (QED-MS/MS) |
| Regulatory Compliance | Fully compliant with FDA 21 CFR Part 11 audit trail, electronic signature, and data integrity requirements |
| Optional Inlets | PPINICI Pulsed Positive/Negative Ion Chemical Ionization Source, DEP/DIP Solid Probe Inlet |
| Flow Control | Digital Mass Flow Controller (MFC) for carrier and reagent gases |
| Origin | Imported |
|---|---|
| Manufacturer Type | Distributor |
| Model | Thermo Scientific Water Quality Analyzer |
| Instrument Type | Laboratory Water Quality Analyzer |
| Price Range | USD 70,000 – 98,000 (based on configuration and regional import duties) |
| Key Compliance | ASTM D1293, ISO 7888, ISO 5667-3, USP <643>, EPA Methods 4500-OC, 4500-BOD, 4500-P, 4500-Cl⁻ |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Weight | 10 kg |
| Wash/ Waste Bottle Capacity | 2 L + 2 L |
| Optional Auxiliary Wash Bottle | 2 L |
| Pre-wash Volume | 15–20 mL |
| Max Operating Pressure (Self-limiting) | 0.5 bar |
| Residual Liquid per Well | < 5 µL (avg.) |
| Accuracy | ±5% |
| Operation Mode | Continuous |
| Adjustable Wash Cycles | 1–15 |
| Dispense Volume Range | 0–750 µL |
| Soak Time | 0–10 min |
| Pause Duration | 0–60 s |
| Wash Head Configurations | Interchangeable 8-channel and 12-channel coaxial cannula tips |
| Auto Pump Shut-off Delay | 30 s idle timeout |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | WellWash AC |
| Price | Upon Request |
| Plate Format | 96-well (U-, V-, or flat-bottom) |
| Wash Heads | 8-, 12-, dual 16-, or dual 24-channel |
| Orbital Shaker | 2 mm amplitude, 650–990 rpm |
| Program Memory | 99 main programs (each supporting up to 4 sub-programs) |
| Wash Volume | 50–1000 µL (50 µL increments) |
| Dispense Volume | 50–400 µL |
| Dispense Accuracy | ±5% at 300 µL |
| Dispense Precision | CV ≤3% at 300 µL |
| Aspiration Residual Volume | <3 µL (standard mode), <1 µL (sweep aspiration mode) |
| Aspiration Height | Adjustable |
| Aspiration Mode | Standard or Sweep |
| Soak & Shake Time | 1–60 min |
| Pre-wash & Rinse Volume | 5–100 mL (5 mL increments) |
| Cycle Count | 1–10 |
| Rinse Time | 100 s (dual 12-channel, 3×350 µL), 140 s (dual 8-channel, 3×350 µL) |
| User Interface | 20-key keypad with 8×12-character LCD |
| Communication Port | RS-232 |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ThermoConcept |
| Pricing | Upon Request |
| (Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 601961 |
| Pricing | Available Upon Request) |
| [Accuracy | ±0.5% of thermocouple range |
| Setpoint Accuracy | ±0.25% of full scale |
| Output Power | Continuously variable, up to 500 W (4.5 A @ 115 VAC) |
| Temperature Stability | –0.004 %/°C |
| Dimensions (W×H×D) | 17.2 cm × 13.3 cm × 5.7 cm |
| Weight | 1.02 kg |
| Input Voltage | 115 VAC, 60 Hz |
| Output Sockets | Two grounded 3-pin receptacles |
| Alarm Interface | AC-powered audible buzzer and visual lamp adapter] |
| Origin | Sweden |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Theta-3D |
| Instrument Class | Dynamic Contact Angle Analyzer |
| Form Factor | Benchtop Laboratory System |
| Contact Angle Measurement Range | 0–180° |
| Angular Resolution | 0.1° |
| Sample Stage Dimensions (L × W × H) | Unlimited × 180 mm × 22 mm |
| Image Resolution | 1280 × 960 pixels |
| Surface & Interfacial Tension Range | 0–1000 mN/m |
| Origin | UK |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | TK3-BASIC |
| Price | Upon Request |
| Origin | Hubei, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | THM-1200/150 |
| Pricing | Upon Request |
| Flow Range | 0.8–1.2 m³/min |
| Accuracy | ±1.5% of reading |
| Repeatability | ≤0.5% |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz |
| Compliance | HJ/T 368–2007, Q/WTH 05–2011 |
| Data Storage | 5000 sets with timestamped T, P, flow, and volume (actual & standard conditions) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 115 |
| Pricing | Available Upon Request |
| Current Ranges | 0–20 mA to 0–65 A |
| Current Resolution | 1 µA to 10 mA |
| Current Accuracy | ±20 µA to ±100 mA |
| Compliance Voltage | >2.5 V to >6 V |
| Control Modes | Constant Current (CC), PID Temperature Feedback |
| Protection Features | Soft Start, Open-Circuit Detection, Short-Circuit Cutoff, Laser Current Limiting, Overtemperature Shutdown, Internal Interlock |
| Origin | Imported |
|---|---|
| Manufacturer Type | Distributor |
| Model | PDA10A |
| Price | Upon Request |
| Wavelength Range | 320–1700 nm |
| Bandwidth | DC to 350 MHz |
| Detector Type | Si and InGaAs |
| Output Interface | BNC |
| Power Supply | External AC adapter (included), optional battery operation |
| Gain Options | Fixed or adjustable |
| Noise Equivalent Power (NEP) | <10 pW/√Hz (typ.) |
| Rise Time | <1 ns (Si), <0.8 ns (InGaAs) |
| Input | Free-space or fiber-coupled (FC/PC) |
| Compliance | CE, RoHS, FDA 21 CFR Part 11 ready (with optional audit trail software) |
| Key Features | Three-chamber design (hot, cold, test chambers) |
|---|---|
| Controller options | TEMI880 color touchscreen programmable temperature/humidity controller (English/Chinese switchable) or TEMI300 membrane-key programmable controller (English only) |
| Protection functions | Compressor overheat/overcurrent/overpressure protection, heater dry-run prevention, chamber over-temperature alarm, low-water-level detection |
| Standard configuration | Double-glazed tempered observation window |
| Temperature/humidity control | Balanced Temperature and Humidity Control System (BTSC) |
| Operating ambient | +5°C to +35°C |
| Heating | Nickel-chromium alloy wire heaters |
| Humidification | Surface evaporation type |
| Air circulation | Wide-band forced-air system (top discharge, bottom intake) |
| Cooling method | Air-cooled |
| Refrigeration | Original French “Tecumseh” hermetic compressors |
| Refrigeration circuit | Single- or dual-stage low-temperature loop design |
| Construction | Outer shell — SUS304B stainless steel |
| Airflow | Multi-wing centrifugal blower |
| Compliance | Designed to support ISO 16750-4, JEDEC JESD22-A104, MIL-STD-810H Method 503.5, IEC 60068-2-14, and ASTM D4332 test protocols |
| Key | High-Temp Zone: +60 °C to +200 °C |
|---|---|
| Low-Temp Zone Options | −10 °C to −40 °C / −10 °C to −60 °C / −10 °C to −70 °C |
| Test Chamber Range | 0 °C to −40 °C / −10 °C to −55 °C / −10 °C to −65 °C |
| Temp. Fluctuation | ±0.5 °C |
| Temp. Uniformity | ±3 °C |
| Temp. Recovery Time | 3–5 min |
| Heat-up Rate (HT Zone) | ~5 °C/min (avg.) |
| Cool-down Rate (LT Zone) | ~1.5 °C/min (avg.) |
| Dwell Time per Stage | ≥30 min |
| Transfer Time (Chamber-to-Chamber) | ≤15 s |
| Key Features | Three-zone design (high-temperature chamber, low-temperature chamber, test chamber) |
|---|---|
| Programmable memory | 100 test profiles, up to 9999 cycles, max 999 h 59 min per segment |
| Data logging | paperless real-time curve display and archival |
| Compliance | MIL-STD-202, IEC 60068-2-14, JIS C 60068-2-14 |
| Optional | LN₂ rapid-cooling module, RS-485/RS-232C communication interface, external temperature data logger |
| Safety | PLC-controlled fault detection, automatic emergency shutdown on power fluctuation, dual thermal overprotection |
| Key Features | Three-zone design (hot zone, cold zone, test zone) |
|---|---|
| Temperature Range | Hot Zone: +80°C to +200°C |
| Cold Zone | −10°C to −70°C |
| Test Zone Operating Range | −10°C to +150°C |
| Temperature Control Accuracy | ±2°C |
| Resolution | 0.1°C |
| Hot Zone Ramp Rate | ~60 min (from ambient to +150°C) |
| Cold Zone Ramp Rate | ~120 min (from ambient to −60°C) |
| Test Zone Recovery Time | ≤3 min (with standard 2 kg I.C. load) |
| Internal Dimensions (Test Zone) | 500 × 350 × 500 mm (W×H×D) |
| External Dimensions | Approx. 1600 × 2050 × 2220 mm (W×H×D) |
| Construction | SUS304 stainless steel interior |
| Exterior | High-tensile cold-rolled steel with solvent-free powder coating |
| Insulation | Fire-retardant PU foam + glass wool, 100 mm thick |
| Compliance | GB10592–1989, GB2423.1, GB2423.2, GJB150.3, GJB150.4, IEC 60068-2-14, MIL-STD-810G |
| Origin | Guangdong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model Range | THV-1000 |
| Temperature Range | -70°C to +100°C |
| Humidity Range | 30–98% RH |
| Temperature Uniformity | ≤2°C |
| Temperature Fluctuation | ±0.5°C |
| Temperature Deviation | ±2°C |
| Humidity Uniformity | ±2/−3% RH (≥75% RH) |
| Internal Dimensions | 1000 × 1000 × 1000 mm |
| Static Load Capacity | 50 kg |
| Air Velocity | 1.0–3.0 m/s (VFD-controlled) |
| Power Supply | 380 V, 50 Hz, 3-phase 5-wire |
| Total Power | 36 kW |
| Compliance Standards | GB 10586–1989, GB 10592–1989, GJB 150.16–1986 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Thwing-Albert |
| Price Range | USD $13,500 – $67,500 (FOB) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FP-2260 |
| Price Range | USD 42,000 – 70,000 |
| Instrument Type | Electromechanical Universal Testing System |
| Temperature Range | 21–176.7 °C (70–350 °F) |
| Maximum Load Capacity | 10 kgf (22 lbf) |
| Crosshead Travel | 355 mm (14 in) |
| Test Area | 225 mm × 350 mm |
| Load Cell Options | 1, 2, 5, and 10 kgf |
| Display | 240 × 64 pixel LCD |
| Data Storage | 128 test records |
| Communication Interfaces | USB & RS-232 |
| Compliant Standards | ASTM D1894, D4521, D2534, D6862, D6252, D3330, D1876, F88 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FP-260 |
| Price Range | USD 13,500 – 68,000 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 106 |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Progage |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | QC-3A |
| Price Range | USD 42,000–70,000 |
| Instrument Type | Electromechanical Universal Testing Machine |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Thwing-Albert Vantage |
| Price Range | USD 14,000 – 70,000 |
| Load Capacity | 1 kN (225 lbf) |
| Peel Angle | Fixed 90° |
| Standard Compliance | ASTM D6862, ASTM D6252, PSTC-1A |
| Fixture Part No. | 1750–3005 |
| Sample Type | Flexible Adhered Substrates (e.g., pressure-sensitive tapes, laminates, labels, medical adhesives) |
| Test Mode | Tensile Peel |
| Grip Configuration | Upper Movable Jaw + Lower Motorized Crosshead with Angularly Constrained Specimen Stage |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | VantageNX Series |
| Price Range | USD $38,000 – $64,000 |
| Instrument Type | Electromechanical Universal Testing Machine |
| Load Capacities | 1 kN, 2 kN, 5 kN (VantageNX Duo), 10 kN (EJA Vantage Series) |
| Frame Configurations | Single-Column (406 mm × 432 mm footprint), Dual-Column (584 mm × 483 mm footprint) |
| Software | MAP4 v5.x (Windows 10 compatible, PC required, not included) |
| Compliance Standards | ASTM E4, ASTM F88, ASTM D790/D791/D882/D3330, ISO 5893/7500-1/9283, EN 10002-1 to -4, TAPPI T494/T541/T811/T825/T839, DIN, FINAT, PSTC, WSP |
| Origin | USA |
|---|---|
| Supplier Type | Authorized Distributor |
| Import Status | Imported |
| Model | THz Lenses |
| Component Category | Optical Element |
| Substrate Materials | HRFZ-Si (High-Resistivity Float-Zone Silicon), TPX (Polymethylpentene) |
| Lens Types | Plano-Convex, Bi-Convex, Positive Meniscus, Hyper-/Hypo-/Hemispherical, Bullet, Diffractive (Fresnel, Beam Divider) |
| Diameter Range | 2 mm to 150 mm |
| EFL Tolerance | ±1% |
| Surface Quality | 80/50 Scratch-Dig |
| Surface Accuracy | ±0.01 mm (spherical), variable for aspheric profiles |
| Clear Aperture | ≥90% |
| Coating | Optional Anti-Reflection (AR) Coating for 0.1–3 THz band |
| Origin | Russia |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | THz Mirrors |
| Price Range | USD 1,400 – 7,000 (FOB) |
| Component Category | Optical Element |
| Material | Fused Quartz |
| Type | Plano-Plano |
| Dimensional Tolerance | ±0.25 mm |
| Clear Aperture | ≥90% |
| Surface Quality (Polished) | 40/20 Scratch-Dig |
| Surface Roughness (Ground Side) | 2.5 Ra (µm) |
| Surface Accuracy | λ/2 @ 633 nm |
| Coating | Protected Gold |
| Gold Layer Thickness | 400 nm |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | THZ-C |
| Pricing | USD 980 (FOB) |
| Instrument Category | Air-Bath Constant-Temperature Shaker / Orbital Shaker |
| Timer Range | 0–999 min |
| Oscillation Frequency | 20–300 rpm |
| Orbit Diameter | 26 mm |
| Temperature Control Range | Ambient to 60 °C |
| Platform Configuration | Single-Shelf Orbital Platform |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | THZ-C-1 |
| Price | USD 2,200 (FOB) |
| Instrument Type | Air-Bath Refrigerated Orbital Shaker |
| Timer Range | 0–999 min |
| Oscillation Frequency | 40–300 rpm |
| Orbit Diameter | 26 mm |
| Temperature Range | –10°C to +60°C |
| Platform Quantity | 1 |