Generic
Filter
Showing 5281–5310 of 5668 results
| Key | Origin: Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | TresCon A |
| Instrument Type | Online Water Quality Analyzer |
| Measured Parameters | Ammonia-N (NH₄⁺-N), Total Phosphorus (TP), Total Nitrogen (TN) |
| Module Capacity | Up to 3 Independent Analytical Modules |
| Compliance | Designed for ISO/IEC 17025-aligned operation, supports GLP/GMP data integrity requirements via audit-trail-enabled software |
| Communication | RS-485, Modbus RTU, optional analog 4–20 mA outputs and Ethernet/IP integration |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | LC-100 Isocratic Configuration |
| Instrument Type | Conventional High-Performance Liquid Chromatograph |
| Flow Rate Range | 0.001–9.999 mL/min |
| Maximum Pressure | 42 MPa |
| Sample Tray Capacity | 54 positions × 2 mL vials / 35 positions × 4 mL vials |
| Injection Volume Range | 0.1–120 µL |
| Column Oven Temperature Range | 5 °C above ambient to 80 °C |
| UV-Vis Wavelength Range | 190–900 nm |
| Data Acquisition Frequency | 50 Hz |
| Origin | Sweden |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | X Scape Area Measuring Instrument |
| Pricing | Upon Request |
| Dimensions | 80 × 50 × 30 mm |
| Maximum Range | ≥20 m |
| Resolution | 0.01 m |
| Accuracy | ±1% of measured distance |
| Area Measurement Range | 3–120,000 m² |
| Power Consumption | 20 mA |
| Battery | 1.5 V AA |
| Weight | 160 g |
| Ultrasonic Frequency | 25 kHz |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | X-Can Series |
| Pricing | Available Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | XDLM-PCB210 |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | X-Rite IntelliTrax |
| Pricing | Available Upon Request |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | X85-2S |
| Price | ¥980 |
| Power Supply | AC 220 V ±10% |
| Speed Range | 100–1500 rpm (customizable up to 2000 rpm) |
| Max. Stirring Volume | 5000 mL |
| Motor Torque | 20 mN·m |
| Heating Power | 600 W |
| Heating Plate Temp. Range | RT to 300 °C |
| Over-Temp Protection | 330 °C |
| Dimensions (W×D×H) | 245 × 150 × 125 mm |
| Heating Plate Diameter | 145 mm |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | XC-30B |
| Instrument Type | 24-Hour Temperature- and Flow-Controlled Gas Sampler |
| Configuration | Single-Channel Gas Sampler |
| Flow Range | 0.1–2500 mL/min |
| Maximum Vacuum Pressure | 30 kPa |
| Flow Stability | ±5% over 24 h |
| Flowmeter Accuracy | ±2.5% FS (dry gas meter), ±2% FS (mass flow sensor) |
| Rated Service Life at Max Flow & Backpressure | 5000 hours |
| Continuous Operation Time at Max Flow & Backpressure | 8 h |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | XC-572 |
| Price Range | USD 13,500 – 40,500 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | XC-6000EPC |
| Price Range | USD 13,500 – 40,500 |
| Dry Gas Meter | Positive Displacement, 0.7 L/rev, Optical Encoder, 8-digit LCD, Resolution: 1 cm³ |
| Flow Control Accuracy | ±2% of full scale (vacuum range: 0–101 kPa) |
| Sampling Flow Mode | Isokinetic or Constant Flow |
| Mass Flow Control Range | 100–2000 cm³/min |
| Proportional Valve | 12 V DC |
| Data Storage | 1 GB onboard memory, up to 99 sampling events (~30 days of typical field data) |
| Barometric Pressure Sensor | 600–1100 mbar |
| Communication Interfaces | Ethernet, USB, Optional Wi-Fi Router |
| Dimensions | 35.56 × 48.26 × 39.37 cm |
| Weight | 15.5 kg |
| Power Supply | 220 V AC, 50 Hz |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | XCB-300I |
| Pricing | Available Upon Request |
| Max Operating Temperature | 300 °C |
| Temperature Control Range | 50–300 °C |
| Temperature Stability | ±2 °C |
| Temperature Uniformity | ±2.5% (at setpoint) |
| Internal Chamber Dimensions | 450 mm × 550 mm × 550 mm (W × D × H) |
| Fan Motor Power | 40 W |
| Heating Power | 2.8 kW |
| Input Voltage | 220 VAC ±10% (−15% to +10% tolerance) |
| External Dimensions | 675 mm × 920 mm × 950 mm (W × D × H) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | XCB-300II |
| Pricing | Available Upon Request |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | XD200-FL |
| Price | USD 6,300 (FOB Beijing) |
| Optical Design | Infinity-Corrected Optical System |
| Objective Mount | Quintuple Nosepiece |
| Eyepiece | Widefield WF10X (Field Number Φ22 mm) |
| Objective Lenses | Plan Achromatic PLL 10X/0.25 (WD 4.3 mm), 20X/0.40 (WD 8.0 mm), 40X/0.60 (WD 3.5 mm) |
| Fluorescence Excitation Bands | UV (330–400 nm), Violet (395–415 nm), Blue (420–485 nm), Green (460–550 nm) |
| Emission Filters | 425 nm, 455 nm, 515 nm, 590 nm |
| Light Sources | 100 W DC Mercury Arc Lamp (Fluorescence), 6 V/30 W Halogen Lamp (Transmitted Light) |
| Focus Mechanism | Coaxial Coarse/Fine Adjustment with Locking & Upper/Lower Limits |
| Fine Focus Graduation | 2 µm |
| Stage | Fixed Mechanical Stage (227 × 208 mm) |
| Condenser | Rotating Phase Contrast Annulus Condenser (WD 55 mm) |
| Eyepiece Tube | 45° Inclined, Interpupillary Distance 53–75 mm |
| Origin | Guangdong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | XDLM-PCB 200 / 210 / 220 |
| Price Range | USD 70,000 – 140,000 |
| Standards Compliance | DIN ISO 3497, ASTM B568 |
| Sample Positioning | Motorized XY Stage (210/220), Manual Drawer-Type Stage (200) |
| Imaging System | High-Resolution Color Camera with Real-Time Overlay |
| Software Platform | WINFTM® v5.2 (Windows-based, CFR Part 11 Ready) |
| Origin | Guangdong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | XDS-3 |
| Price | USD 2,300 (FOB Guangdong) |
| Key | Chamber Internal Dimensions: 400 × 1250 × 700 mm (D×W×H) |
|---|---|
| External Dimensions | 450 × 1350 × 1700 mm (D×W×H) |
| Temperature Range | RT+10°C to 70°C |
| Humidity Range | 65–95% RH |
| Sample-to-Lamp Distance | 240 mm |
| Spectral Range | 295–330 nm |
| Irradiance | 1000 µW/cm² @ 340 nm |
| Illumination & Condensation Cycle | Programmable |
| Lamp Configuration | 8 × 1200 mm, 40 W xenon arc lamps |
| Interior Material | SUS304 stainless steel |
| Control System | Fuji digital temperature controller (Japan) + programmable timer |
| Water Consumption | ~8 L/day (deionized or distilled water recommended) |
| Condensation Method | Gravity-fed, non-pressurized dew formation |
| Key | Chamber Interior Dimensions: 500 × 700 × 600 mm |
|---|---|
| Temperature Range | RT to +80 °C (adjustable) |
| Humidity Range | 45–90 % RH (adjustable) |
| Black Panel Temperature | 63 °C or 100 °C ±2 °C |
| Temperature Uniformity | ±2.0 °C |
| Temperature Fluctuation | ±0.5 °C |
| Humidity Deviation | ≤±2 % RH |
| Xenon Lamp Type | Air-Cooled, 1.8 kW |
| Spectral Range | 290–800 nm |
| Irradiance (290–800 nm) | 550 W/m² |
| Sample Rack Distance from Lamp | 230–280 mm |
| Rainfall Duration | 0–9999 min (continuous) |
| Rainfall Cycle | 0–240 min (cyclic/intermittent) |
| Nozzle Orifice Diameter | Ø0.8 mm |
| Heating Power | 3 kW |
| Humidification Power | 1.5 kW |
| Total Rated Power | 9 kW |
| Sample Tray | 1-layer, height-adjustable |
| Filter Glass | 1 piece |
| Compliance | Designed per ISO 4892-2, ASTM G155, SAE J2527, and GB/T 16422.2 |
| Key | Temperature Range: RT+10°C to 70°C |
|---|---|
| Humidity Range | 50–98% RH |
| Black Panel Temperature | 63–100°C ±3°C |
| Temp. Uniformity | ≤±2.0°C |
| Temp. Stability | ≤±0.5°C |
| Humidity Stability | +2% to −3% RH |
| Rain Duration | 1–9999 min (adjustable, continuous) |
| Rain Cycle | 1–240 min (adjustable, intermittent) |
| Nozzle Diameter | Ø2.0 mm |
| Water Pressure | 0.12–0.15 MPa |
| Spray Cycle | 18 min ON / 102 min OFF or 12 min ON / 48 min OFF |
| Lamp Type | Air-Cooled Xenon Arc Lamp |
| Lamp Quantity | 1 |
| Lamp Power | 2–6 kW |
| Sample Distance from Lamp | 300–375 mm |
| Sample Holder Rotation | 360°, 1–5 rpm |
| Irradiance Spectrum | 290–800 nm |
| Irradiance Range | 50–1100 W/m² |
| Cumulative Radiant Exposure | 14,000–67,000 kJ/m² |
| Illumination Time Control | 1–999 h (continuously adjustable) |
| Power Supply | AC 380 V (±10%), 50 Hz, 3-phase 5-wire |
| Key Features | 500L or 700L chamber volume |
|---|---|
| Xenon lamp power | 4.5 kW / 6.0 kW (long-arc, full-spectrum solar simulation) |
| Irradiance control | 550 W/m² (at 340 nm or 420 nm band, adjustable) |
| Black panel temperature range | 50–90 °C |
| Temperature uniformity | ≤ ±3 °C |
| Relative humidity range | 55–90 %RH |
| Sample-to-lamp distance | 250–300 mm |
| Effective exposure area | 1600 cm² |
| Lamp service life | ≈1200 h |
| Spray cycle | programmable on/off duration up to 999 min each |
| Power supply | 380 VAC / 50 Hz, total rated power 12 kW / 15 kW |
| Controller | programmable touchscreen with xenon-specific algorithm and real-time irradiance feedback via fiber-optic sensor |
| Cooling | forced-air convection with axial fan and PID-controlled thermal management |
| Safety | interlocked door switch (lamp auto-off), overtemperature protection, dry-run prevention for spray system |
| Key | Power Supply: 380 V AC / 50 Hz |
|---|---|
| Total Power | 9 kW |
| Xenon Lamp | 6 kW water-cooled long-arc lamp (full solar spectrum) |
| Irradiance Control Range | 350–850 nm, nominal 550 W/m² |
| Optional Monitoring Wavelengths | 340 nm or 365 nm |
| Temperature Range | (RT + 10)°C to 70°C |
| Temperature Uniformity | ±2°C |
| Sample Rotation Speed | ≥1 rpm (stepless adjustment) |
| Wet/Dry Cycle Options | 60 min irradiation / 12 min spray or 102 min / 18 min |
| Chamber Interior Dimensions | 950 × 950 × 900 mm |
| Spray Pressure | 78–127 kPa |
| UV Cut-off Filter | <255 nm blocked (0%), 400–800 nm transmittance >90% |
| Construction | Cold-rolled steel exterior with powder coating, SUS304 stainless steel interior, silicone rubber door seal |
| Control System | South Korean TEMI850 touchscreen controller |
| Cooling | Closed-loop chiller system for xenon lamp |
| Radiation Measurement | Fiber-optic coupled broadband radiometer |
| Temperature Sensing | Wireless black panel thermometer (BPT) or black standard thermometer (BST) |
| Safety | Interlocked cooling-water circuit, overtemperature/overcurrent/short-circuit protection, low-water cutoff, grounding protection |
| Key | Working Chamber Size: Customizable |
|---|---|
| Humidity Range | 40–98% RH |
| Temperature Range | 10–70 °C |
| Black Panel Temperature | 40–110 °C |
| Temperature Uniformity | ±2 °C |
| Temperature Stability | ≤±0.5 °C |
| Humidity Deviation | ≤±3% RH |
| Rainfall Cycle | 1–9999 min (adjustable, continuous or periodic) |
| Light Source | Long-Arc Air-Cooled Xenon Lamp |
| Lamp Power Options | 1.5 / 2.5 / 3.0 / 6.0 kW per lamp |
| Lamp Lifetime | ≥1500 h |
| Total Exposure Area | ≥6000 cm² |
| Irradiance Range | 0–1100 W/m² (solar-spectrum-weighted) |
| Spectral Range | 280–900 nm |
| Irradiance Monitoring Points | 340 nm, 300–400 nm, 420 nm |
| Light Intensity Control | 5–100% |
| Light/Dark Cycle | 10 min – 99.99 min |
| Cooling Method | Air-cooled heat exchanger + air-cooled compressor |
| Filter System | Borosilicate & soda-lime optical glass filters (manual exchange for indoor/outdoor simulation) |
| Control Interface | Touchscreen HMI with embedded control software, data logging ≥2 years, USB export capability |
| Structural Material | 1.2 mm SUS316L stainless steel |
| Observation Window | 300 × 700 mm multilayer insulated radiation-shielded glass with UV-filtering overlay |
| Compliance | ASTM G155, ASTM D4459, GB/T 2423.24, GB/T 5137.3 |
| Temperature Range | RT+10°C to 70°C |
|---|---|
| Humidity Range | 65–98% RH |
| Rainfall Duration | 1–9999 h 59 min (adjustable) |
| Rainfall Cycle | 1–240 min (interval adjustable) |
| Irradiance | ≤300 W/m² (at specimen plane, 300–800 nm) |
| Xenon Lamp Total Power | 12.0 kW (rated lifetime: ≥1600 h) |
| Control Accuracy | Temperature ±0.1°C (set/indicated), Humidity ±1% RH |
| Black Panel Temperature Sensor | Dual-metal thermometric type |
| Heating System | Independent Ni-Cr alloy resistive heaters |
| Humidification System | External stainless steel shallow-surface evaporative humidifier |
| Air Circulation | Low-noise, high-temp-resistant centrifugal blower with multi-blade impeller |
| Power Supply | AC 380 V ±10%, 50 ±0.5 Hz, 3-phase 4-wire |
| Ambient Operating Conditions | 5–30°C, ≤85% RH |
| Key | Brand – Other Brands |
|---|---|
| Construction – Interior | SUS304 stainless steel |
| Exterior | Powder-coated steel |
| Key | Irradiance at 340 nm: 0.5 W/m² |
|---|---|
| Irradiance at 300–400 nm | 60 W/m² |
| Test Chamber Interior Dimensions (H×D×W) | 800 × 900 × 800 mm |
| Lamp Type | 4500 W water-cooled xenon arc lamp |
| Filter Options | Borosilicate (267–800 nm) or Soda-lime (300–800 nm) |
| Sample Turntable Diameter | 690 ± 3 mm |
| Construction | Interior and exterior of SUS#304 stainless steel (1.0 mm thickness, brushed finish interior / powder-coated exterior) |
| Key | Temperature Uniformity: ±2°C |
|---|---|
| Temperature Fluctuation | ±0.5°C |
| Operating Temperature Range | RT+10°C to 70°C |
| Humidity Range | 90–98% RH |
| Internal Chamber Dimensions (W×H×D) | 450 × 1170 × 500 mm |
| Effective Irradiation Area | 900 × 210 mm |
| Black Panel Temperature Range | 40–65°C |
| UV Spectrum | UV-A (315–400 nm), UV-B (280–315 nm) |
| Sample-to-Lamp Distance | 50 mm |
| Lamp Center Spacing | 70 mm |
| Standard Specimen Size | 75 × 150 mm or 75 × 300 mm |
| Exposure Time Range | 0–999 h |
| Condensation Cycle Control | Adjustable |
| Control Method | PID Auto-Tuning |
| Water Tray Depth | 25 mm (Auto-Maintained) |
| Power Supply | AC 380 V ±10%, 50 ±0.5 Hz, 3-phase 5-wire |
| Ambient Operating Conditions | 5–30°C, ≤85% RH |
| Construction | Exterior – Powder-Coated Carbon Steel or SUS304 Brushed Stainless Steel |
| Safety Protections | Overtemperature, Leakage Current, Short Circuit, Motor Overheat, Overcurrent, Low-Water Level Detection |
| Key | Internal Dimensions (D×W×H): 400×1250×700 mm |
|---|---|
| External Dimensions (D×W×H) | 450×1350×1700 mm |
| Temperature Range | RT+10°C to 70°C |
| Humidity Range | 65–95% RH |
| Sample-to-Lamp Distance | 240 mm |
| Spectral Range | 295–330 nm |
| Irradiance | 1000 µW/cm² @ 340 nm |
| Lamp Configuration | 8 × 40 W, 1200 mm linear xenon arc lamps |
| Condensation Method | Gravity-fed water condensation |
| Inner Chamber Material | SUS304 stainless steel |
| Control System | Digital temperature & timer controller |
| Water Consumption | ~8 L/day (deionized or distilled water recommended) |
| Key | Lamp Power: 6 kW |
|---|---|
| Spectral Range | 290–800 nm |
| Irradiance Control | 550–1200 W/m² |
| Sample Rotation Speed | ≥1 rpm (infinitely variable) |
| Rainfall Duration | 1–9999 min (adjustable) |
| Rainfall Cycle Interval | 1–240 min (adjustable) |
| Irradiated Area | ~7500 cm² |
| Lamp-to-Sample Distance | 350–380 mm |
| Heating Power | ~3.6 kW |
| Humidification Power | ~3 kW |
| Cooling System | Single-stage hermetic compressor (Tecumseh/Tecumseh France equivalent) with R404A refrigerant |
| Evaporator Layout | Air-forced convection within ducted chamber wall |
| Humidity Control | PID-regulated steam humidification |
| Compliance | Designed to support ASTM G155, ISO 4892-2, SAE J2527, and AATCC TM16 test protocols |