Generic
Filter
Showing 2611–2640 of 5744 results
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | KQ-800TDE |
| Price | USD 4,150 (FOB Shanghai) |
| Dimensions (L×W×H) | 530×320×380 mm |
| Tank Interior (L×W×H) | 500×300×150 mm |
| Capacity | 22.5 L |
| Ultrasonic Frequency | 40 kHz / 80 kHz dual-frequency auto-switching |
| Ultrasonic Power Output | 800 W (adjustable 40–100%) |
| Heating Power | 1000 W |
| Temperature Control Range | 20–80 °C (±0.5 °C stability) |
| Cooling Function | Integrated Peltier-based active cooling module |
| Timer Range | 1–999 s |
| Display | Digital LED with memory for frequency, power, time, set/actual temperature |
| Tank Material | SUS304 stainless steel |
| Lid | Acoustic-dampening stainless steel cover with corrosion-resistant EPDM gasket |
| Drain Valve | Brass ball valve with stainless steel handle |
| Mesh Basket | Laser-cut SUS304 perforated tray, TIG-welded construction |
| Filtration | Optional inline recirculating filtration system (compatible with 5–20 µm filter cartridges) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Models | KQ-100KDB, KQ-100KDE, KQ-200KDB, KQ-200KDE, KQ-200KDV, KQ-400KDB, KQ-400KDE, KQ-400KDV |
| Frequency | 40 kHz |
| Power Range | 100–400 W (ultrasonic), 200–1000 W (heating) |
| Tank Capacity | 2–27 L |
| Temperature Range | 20–80 °C |
| Timer Range | 1–480 min |
| Construction | Stainless steel tank (except KQ-100 series: plastic housing) |
| Safety Features | Over-temperature, over-voltage, and over-current digital protection |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | KQ5200DE |
| Price | USD 820 (FOB Shanghai) |
| Dimensions (W×D×H) | 320 × 264 × 320 mm |
| Tank Internal Dimensions | 300 × 240 × 150 mm |
| Tank Capacity | 10 L |
| Ultrasonic Frequency | 40 kHz |
| Total Ultrasonic Power Output | 200 W |
| Power per Transducer | 50 W (4 transducers) |
| Temperature Control Range | Ambient to 80 °C (adjustable in 1 °C increments) |
| Timer Range | 1–99 minutes (digital preset & countdown) |
| Safety Features | Low-level liquid detection, over-temperature, over-voltage, and over-current protection |
| Construction | Stainless steel tank (304 grade), stainless steel mesh basket (TIG-welded), sound-dampening lid, integrated drain valve |
| Cumulative Operating Hours Counter | Up to 999,999 hours |
| Control System | Embedded microcontroller-based digital interface with real-time parameter display and memory retention |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | DSA100 |
| Instrument Type | Benchtop Laboratory System |
| Contact Angle Measurement Range | 0–180° |
| Contact Angle Resolution | ±0.01° |
| Contact Angle Accuracy | 0.1° |
| Sample Stage Dimensions | 300 × 150 mm (standard), extendable to 500 × 48 mm |
| Optical Magnification | 0.7× (adjustable via zoom lens |
| FOV diagonal | 1.6–11 mm) |
| Surface/Interfacial Tension Measurement Range | 0.01–1000 mN/m |
| Surface/Interfacial Tension Resolution | 0.01 mN/m |
| High-Speed Camera Options | 60 fps (standard), up to 1000 fps (optional), customizable to 10,000+ fps |
| Temperature Control Range (Peltier) | –30 to +160 °C |
| Extended Thermal Stage (TC21) | –60 to +400 °C |
| Humidity Control Chamber | 5–95% RH |
| Automated Sample Handling | Up to 8 positions |
| Software Analysis Methods | Sessile Drop, Tilting Plate, Pendant Drop, Oscillating Drop, Single-Fiber Mode |
| Surface Energy Calculation Models | Owens-Wendt-Rabel, van Oss-Chaudhury-Good, Fowkes, Extended Fowkes, Wu, Zisman, Neumann |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DSA100E |
| Pricing | Available Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | DSA20 |
| Pricing | Available Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DSA25E |
| Pricing | Available Upon Request |
| Origin | Germany |
|---|---|
| Instrument Type | Benchtop Laboratory System |
| Measurement Principle | Optical Imaging (Video-Based Drop Shape Analysis) |
| Contact Angle Range | 0°–180° |
| Contact Angle Resolution | ±0.01° |
| Surface/Interfacial Tension Range | 0.01–2000 mN/m |
| Surface Tension Resolution | 0.01 mN/m |
| Optical Magnification | 7× (motorized, software-controlled) |
| Field of View (FOV) | 3.2–23 mm |
| High-Speed Camera | 311 fps (standard), optional full-frame ultra-high-speed up to 20,000 fps |
| Image Resolution | 780 × 580 pixels (standard) |
| Sample Stage Dimensions (max. accommodated) | 320 mm (W) × ∞ (D) × 275 mm (H) |
| Stage Mobility | Motorized X/Y/Z translation (X/Y: ±100 mm |
| Z | ±38 mm) |
| Dispensing Systems | Dual automated syringe modules (0.01 µL minimum step), manual dispensing unit, auto-refill & auto-cleaning module, dedicated 50 nL precision dosing system |
| Data Throughput | 800 MB/s |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | K100 |
| Pricing | Available Upon Request |
| Measurement Principle | Du Noüy Ring Method |
| Compliance | ASTM D971, ASTM D1331 |
| Measurement Range | 0–90 mN/m (dyne/cm) |
| Accuracy | ±0.25 mN/m |
| Standard Accessories | Platinum-Iridium Ring, Dual Stainless-Steel Torsion Wires, Analog Absolute-Value Scale |
| Operation Modes | Manual & Semi-Automatic |
| Drive System (Semi-Auto) | Reversible Synchronous Motor |
| Dual-Scale Dial | Upward/Downward Force Reading |
| Application Scope | Oil-Water Interfacial Tension, Surfactant Solution Characterization, Quality Control in Lubricants & Detergents |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | K100C |
| Price Range | USD 27,000–68,000 (est.) |
| Measurement Range | 1–2000 mN/m |
| Resolution | 0.01 mN/m |
| Accuracy | ±0.01 mN/m |
| Temperature Display Range | −10 to +130 °C |
| Temperature Display Precision | ±0.1 °C |
| Measurement Methods | Du Noüy Ring Method, Wilhelmy Plate Method |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | K100C |
| Pricing | Available Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | MSA Flexible Liquid |
| Pricing | Available Upon Request |
| Motor | 370 W, 220 V, 50 Hz |
|---|---|
| Crankshaft Speed | 630 rpm |
| Reciprocating Stroke | 16 mm |
| Max. Amplitude (Upper/Lower) | 8 mm |
| Arm Oscillation Angle | 30° |
| Dimensions (L×W×H) | 790 × 520 × 1090 mm |
| Weight | 63 kg |
| Key | Internal Chamber Dimensions: 40 × 35 × 30 cm |
|---|---|
| High-Temperature Zone Range | RT to +100 °C |
| Low-Temperature Zone Range | −40 °C to −10 °C |
| Thermal Shock Range | +100 °C / −40 °C |
| Ramp Rate (Heating) | ~15 min from RT to +100 °C |
| Ramp Rate (Cooling) | ~60 min from RT to −40 °C |
| Dwell Time per Cycle | 0.1–999.9 h |
| Cycle Count Programmable | 1–9999 |
| Recovery Time after Shock | ≤5 min |
| Max. Sample Mass | 1.5 kg |
| Construction | Exterior & Interior – SUS304 brushed stainless steel (interior mirror finish) |
| Refrigeration System | Dual-stage cascade refrigeration, water-cooled, hermetic or semi-hermetic compressors (EU/US origin) |
| Controller | Full-color LED touchscreen HMI with PID auto-tuning |
| Safety Protections | Overcurrent fuses, compressor overheat/overpressure/overcurrent protection, dry-heater alarm, chamber overtemperature alarm |
| Standard Accessories | One φ50 mm test port, two sample racks |
| Refrigerants | R404A / R23 (zero ODP, low GWP HFC blends) |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | kSA400 RHEED |
| Pricing | Available Upon Request |
| Compliance | RoHS Directive 2011/65/EU |
| Beam Energy Range | 10–30 keV |
| Incidence Angle | < 5° (grazing incidence) |
| Emission Current | Standard Mode / Low-Emission Mode (MCP-enhanced, ~0.02–0.35% of conventional RHEED current) |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | V-400E |
| Detection Method | Pulse-Echo Mode |
| Waveform Type | Pulsed Ultrasound |
| Maximum Scan Speed | 2000 mm/s |
| Minimum Scan Area | 200 µm × 200 µm |
| RF Bandwidth | 500 MHz |
| Probe Configuration | Single Transducer (Standard) |
| Frequency Range (Optional Probes) | 100–2000 MHz |
| Axial Resolution (Typical) | <100 nm (with Nano-series transducers) |
| Integrated Optical Microscopy | Yes (Inverted & Epi-Illumination Configurable) |
| Compliance | ASTM E1783, ISO 16932, IPC-J-STD-035, JEDEC JESD22-A108 |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | KSZD-20 |
| Price | Upon Request |
| Measurement Principle | Dual-Detector Transmitted & 90° Scattered Light (ISO 7027 Compliant) |
| Range Options | A-Type: 0–200 NTU / 0–4000 NTU |
| B-Type | 0–10 NTU / 0–200 NTU |
| Accuracy | ±5% (A-Type), ±3% (B-Type) |
| Repeatability | ±5% |
| Process Temp. | 0–40 °C |
| Ambient Op. Temp. | 0–50 °C |
| Humidity | 65 ± 20% RH |
| Output | Isolated 4–20 mA (scalable), RS232 Serial Interface |
| Power Supply | 220 V AC, 50 Hz |
| Installation | In-line Pipe Mount or Submersible Probe Mount |
| Configuration | Integrated or Remote Sensor + Controller |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | KT-401 |
| Price Range | USD 0.15 – 750 (FOB) |
| Measurement Range | 1 × 10⁴ to 1999 × 10⁴ ions/cm³ |
| Resolution | 1 × 10⁴ ions/cm³ |
| Display | 3.5-digit LCD (max 1999) |
| Power Supply | LR44 button cell (x2) |
| Dimensions | 78 mm (L) × 27 mm (W) × 9 mm (H) |
| Ion Polarity Detection | Simultaneous positive and negative ion concentration readout |
| Sample Interface | Passive air sampling via integrated collector electrode |
| Compliance | Designed per IEC 61000-4-2 ESD immunity guidelines for handheld electrostatic sensors |
| Origin | Fujian, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | KT-401P |
| Price Range | USD 0.15 – 750 |
| Display | 3.5-digit LCD |
| Measurement Range | 1 × 10⁴ – 1999 × 10⁴ ions/cm³ |
| Max Display | 1999 × 10⁴ ions/cm³ |
| Resolution | 1 × 10⁴ ions/cm³ |
| Polarity | Negative ions only |
| Peak Hold Function | Yes |
| Power Source | LR44 button cell (x2) |
| Dimensions | 78 mm (L) × 27 mm (W) × 9 mm (H) |
| Warranty | 1-year limited warranty, lifetime technical support |
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | Kubelka |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model Series | PHE127, PHE167, PHE224, PHE227, PHP164, PHP167 |
| Output | 0.5–6 VDC (ratiometric or fixed), 4-wire shielded |
| Pressure Ranges | 2–600 bar (absolute, gauge, sealed gauge) |
| Operating Temperature | −55 °C to +150 °C (peak +150 °C) |
| Diaphragm & Housing Material | Grade 5 Titanium (Ti-6Al-4V) or 17-4 PH Stainless Steel |
| Accuracy (Nonlinearity + Hysteresis) | ≤ ±0.25 %FS (standard), ≤ ±0.05 %FS (high-precision PGP variants) |
| Overpressure Limit | 150–300 %FS depending on range |
| Burst Pressure | 200–300 %FS |
| Response Time | ≤ 0.5 ms (PHE127/PHE167), 1–2 ms (PHE224/PHE227/PGP) |
| Electrical Connection | MIL-C-26482 circular connector (optional) or 1 m shielded Viton® cable (4-conductor) |
| IP Rating | IP65 (absolute/sealed gauge), IP50 (vented gauge) |
| Mounting Threads | M5×0.8, M10×1, M14×1.5, 1/4 NPT (male/female options) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | XTL Series |
| Price | Upon Request |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | KQ-2200DA |
| Dimensions (W×D×H) | 260 × 160 × 260 mm |
| Tank Internal Dimensions (W×D×H) | 230 × 140 × 100 mm |
| Tank Capacity | 3 L |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power Output | 100 W |
| Power per Transducer | 80 W |
| Temperature Control Range | Ambient to 80 °C (adjustable) |
| Timer Range | 1–99 min (digital preset & memory) |
| Safety Features | Low-water level detection, over-temperature/over-voltage/over-current protection, auto-shutdown |
| Construction | 304 Stainless Steel Tank |
| Accessories | Removable stainless steel mesh basket (standard on KQ-2200DB/DE |
| Noise Reduction | Optional acoustic lid available (KQ-2200DE variant) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Country of Origin | PRC |
| Model | KQ-3200DE |
| Dimensions (W×D×H) | 260×160×260 mm |
| Tank Internal Dimensions | 230×140×100 mm |
| Tank Capacity | 3 L |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power Output | 100 W |
| Temperature Control Range | Ambient to 80 °C (adjustable) |
| Timer Range | 1–99 min |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | KQ-600KDB |
| Price | USD 1,450 (FOB Shanghai) |
| Dimensions (W×D×H) | 320×264×360 mm |
| Tank Interior (W×D×H) | 300×240×150 mm |
| Capacity | 10 L |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power Output | 600 W |
| Heating Power | 600 W |
| Temperature Range | 20–80 °C |
| Timer Range | 1–480 min |
| Drain Valve | Yes |
| Lid | No |
| Tank Material | 304 Stainless Steel |
| Rack Material | 304 Stainless Steel (argon-welded mesh) |
| Safety Protections | Digital over-temperature, over-voltage, and over-current monitoring with LED indicators |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Models | KQ-600KDE, KQ-600KDV, KQ-600KDB, KQ-800KDB, KQ-800KDE, KQ-800KDV |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power Output | 600 W (KQ-600 series) / 800 W (KQ-800 series) |
| Heating Power | 600 W (KQ-600) / 1000 W (KQ-800) |
| Temperature Range | 20–80 °C |
| Timer Range | 1–480 min |
| Tank Material | 304 Stainless Steel (inner tank) |
| Optional Features | Acoustic Lid (E-series), Drain Valve (B/D/V-series), Vapor Recovery System (V-series) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | KQ-5200DB |
| Price | USD 795 (FOB Shanghai) |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power Output | 200 W |
| Adjustable Power Range | 40–100% |
| Tank Capacity | 10 L |
| Internal Tank Dimensions | 300 × 240 × 150 mm (L×W×H) |
| External Dimensions | 320 × 264 × 320 mm (L×W×H) |
| Heating Power | 600 W |
| Temperature Control Range | 20–80 °C |
| Timer Range | 1–480 min |
| Stainless Steel Mesh Basket | Included |
| Sound-Dampening Lid | Included |
| Drain Valve | Included |
| Tank Material | 304 Stainless Steel |
| Control System | Microprocessor-Based Digital Interface |
| Safety Protections | Low-Level Fluid Detection, Over-Temperature, Over-Voltage, Over-Current, and Auto-Shutdown |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Kurabo QuickGene-610L |
| Price Range | USD 27,000–40,000 (FOB) |
| Automation Level | Dedicated Fully Automatic |
| Throughput per Run | 6 samples |
| Sample Volume Range | 2 mL |
| Processing Time per Batch | 12 minutes |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | QuickGene-810 |
| Price Range | USD 27,000–40,000 (FOB) |
| Automation Level | Dedicated Fully Automatic |
| Throughput per Run | 8 samples |
| Sample Volume Range | 200 µL |
| Processing Time per Batch | 8 minutes |