GILL
Filter
Showing 31–48 of 48 results
| Brand | Gill |
|---|---|
| Origin | United Kingdom |
| Model | R3-50 |
| Instrument Type | Ultrasonic Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0–45 m/s |
| Accuracy | ±1% of reading |
| Operating Temperature | −40 °C to +60 °C |
| Operating Humidity | 0–100% RH |
| Output Rate | 50 Hz |
| Output Parameters | U, V, W, Sonic Temperature (SOS) |
| Brand | Gill |
|---|---|
| Origin | USA |
| Model | TFT |
| Display Size | 8.5-inch LED-backlit industrial LCD |
| Viewing Angle | 170° true wide-angle |
| Resolution | WVGA (800 × 480) |
| Wind Data Input | NMEA 0183 (4800 baud) directly from Gill anemometers |
| Power Output | +15 VDC for sensor and daisy-chain expansion |
| Power Input | 100–240 VAC, 50/60 Hz (max. 50 VA) or optional 18–32 VDC |
| Dimensions | 238 × 148.5 × 71 mm |
| Weight | 1.2 kg |
| IP Rating | IP22 |
| Operating Temperature | −15 °C to +55 °C |
| Operating Humidity | 10–93 % RH |
| EMC Compliance | IEC 61000-4-2 (ESD), IEC 61000-4-3 (Radiated Immunity), IEC 61000-4-4 (Fast Transients), IEC 61000-4-5 (Surge), IEC 61000-4-6 (Conducted Immunity) |
| Brand | Gill |
|---|---|
| Origin | United Kingdom |
| Model | WindMaster |
| Instrument Type | Ultrasonic Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0–50 m/s |
| Accuracy | ±1.5% of reading |
| Operating Temperature | −40 °C to +70 °C |
| Operating Humidity | 5–100% RH |
| Output Frequency | 20 Hz (32 Hz optional) |
| Outputs | U, V, W velocity components, sonic temperature, speed of sound |
| Construction | Aluminum alloy and carbon fiber housing |
| Calibration | Optional traceable wind tunnel calibration per unit |
| Brand | GILL |
|---|---|
| Origin | United Kingdom |
| Model | WindMaster HS |
| Instrument Type | Ultrasonic Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0–45 m/s |
| Accuracy | <1.5% RMS @ 12 m/s |
| Operating Temperature | −40 °C to +70 °C |
| Relative Humidity | 5–100% RH |
| IP Rating | IP65 |
| Output Frequency | Up to 32 Hz |
| Ultrasonic Temperature Range | −40 °C to +70 °C |
| Wind Direction Accuracy | 2° @ 12 m/s (standard), 0.5° @ 12 m/s (customizable) |
| Sonic Temperature Resolution | 0.01 °C |
| Sound Speed Accuracy | < ±0.5% @ 20 °C |
| Sampling Frequency | 20 Hz or 32 Hz (user-selectable) |
| Analog I/O | 4-channel 14-bit ADC (input/output configurable) |
| Digital Interface | RS-232/422/485, ASCII or binary protocol, baud rate 2400–57600 |
| Power Supply | 9–30 VDC, 55 mA @ 12 VDC |
| Dimensions | 956 × 347 × 120 mm |
| Weight | 2.96 kg |
| Brand | Gill |
|---|---|
| Origin | United Kingdom |
| Model | WindMaster HS |
| Instrument Type | Ultrasonic Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0–45 m/s |
| Accuracy | ±1% of reading |
| Operating Temperature | −40 °C to +60 °C |
| Operating Humidity | 5–100% RH |
| Output Frequency | 32 Hz |
| Output Signals | U, V, W vector components, sonic temperature |
| Housing Material | Stainless steel |
| Analog I/O | 4-channel integrated electronics |
| Brand | Gill |
|---|---|
| Origin | United Kingdom |
| Model | WindMaster Pro |
| Instrument Type | Ultrasonic Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0–65 m/s |
| Accuracy | ±1.5% of reading |
| Operating Temperature | −40 °C to +70 °C |
| Operating Humidity | 5–100% RH |
| Output Frequency | 32 Hz |
| Output Parameters | U, V, W velocity components, sonic temperature, speed of sound |
| Housing Material | Stainless steel |
| Optional Calibration | Traceable wind tunnel calibration (Gill-certified) |
| Analog I/O & PRT Resolution | 14-bit |
| Brand | Gill |
|---|---|
| Origin | United Kingdom |
| Model | WindMaster RA |
| Instrument Type | Ultrasonic Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0 – 50 m/s |
| Accuracy | ±1.5% of reading |
| Operating Temperature | −40 °C to +70 °C |
| Operating Humidity | 5–100% RH |
| Output Frequency | Standard 20 Hz (optional 32 Hz) |
| Output Parameters | U, V, W velocity components, sonic temperature, speed of sound |
| Construction Material | Anodized aluminum and carbon fiber composite |
| Calibration | Optional traceable wind tunnel calibration per unit |
| Brand | Gill |
|---|---|
| Origin | United Kingdom |
| Model | WindObserver 65 |
| Instrument Type | Ultrasonic Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0–65 m/s |
| Accuracy | ±2% |
| Operating Temperature | −55 °C to +70 °C |
| Operating Humidity | 0–100% RH |
| Ingress Protection | IP66 |
| Material | Stainless Steel |
| Compliance | WMO Guide to Meteorological Instruments and Methods of Observation (WMO-No. 8, 7th Ed., 2008) |
| Output | Digital (RS-232/RS-485, SDI-12, or optional Modbus RTU) |
| Brand | GILL |
|---|---|
| Origin | United Kingdom |
| Model | WindObserver 70 |
| Instrument Type | Ultrasonic Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0–75 m/s |
| Accuracy | ±2% of reading |
| Operating Temperature | −55°C to +70°C |
| Operating Humidity | 0–100% RH |
| Heating Power | 150 W (1 W/cm²) |
| Electrical Input | 7 A @ 24 VAC/DC |
| Wind Direction Range | 0–360° (dead-zone-free) |
| Calibration | NIST-traceable |
| Enclosure Material | Stainless steel |
| Ingress Protection | IP66 |
| Compliance | FAA AC 150/5220-9C, UK CAA CAP 744, ICAO Annex 3, WMO Guide to Meteorological Instruments and Methods of Observation (WMO-No.8, 7th ed., 2008) |
| Brand | GILL |
|---|---|
| Origin | United Kingdom |
| Model | WindObserver 75 |
| Instrument Type | Ultrasonic Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0–75 m/s |
| Accuracy | ±2% of reading |
| Operating Temperature | −55 °C to +70 °C |
| Operating Humidity | 0–100% RH |
| IP Rating | IP66 |
| Heating Power | 150 W (7 A @ 24 VAC/DC, ~1 W/cm²) |
| Output Interface | RS422/RS485 (half-duplex, multi-drop capable) |
| Wind Direction Range | 0–359° (continuous, no dead zone) |
| Calibration | NIST-traceable |
| Compliance | WMO Guide to Meteorological Instruments and Methods of Observation (WMO-No. 8, 7th Ed., 2008) |
| Brand | GILL |
|---|---|
| Origin | United Kingdom |
| Model | WindObserver 90 |
| Instrument Type | Ultrasonic Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0 – 90 m/s |
| Accuracy | ±2% of reading |
| Operating Temperature | −55 °C to +70 °C |
| Operating Humidity | 0–100% RH |
| Heating Power | 150 W (7 A @ 24 VAC/DC, ~1 W/cm²) |
| Wind Direction Range | 0–360° (continuous, no dead zone) |
| Calibration | Traceable to NIST, performed in Merlin wind tunnel |
| Enclosure Material | Stainless steel (AISI 316) |
| Ingress Protection | IP66 |
| Output Interface | RS-422 / RS-485 (half-duplex, multi-drop capable) |
| Compliance | Meets WMO standards for mean wind and gust reporting |
| Mounting Options | Multiple base configurations available |
| Cable/Connector Options | Field-selectable |
| Brand | Gill |
|---|---|
| Origin | United Kingdom |
| Model | WindObserver II |
| Instrument Type | Ultrasonic Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0–65 m/s |
| Accuracy | ±2% of reading |
| Operating Temperature | −55 °C to +70 °C |
| Operating Humidity | 5–100% RH |
| Ingress Protection | IP66 |
| Housing Material | Stainless Steel |
| Certification | Lloyds Register Type Approved |
| Output Interfaces | 1 digital (RS-422/RS-485), 3 analog (4–20 mA or 0–10 V) |
| WMO Compliance | Wind averaging and gust algorithms aligned with WMO Guide to Meteorological Instruments and Methods of Observation (WMO-No. 8, 7th Ed., 2008) |
| Optional Feature | Integrated de-icing system |
| Brand | Gill |
|---|---|
| Origin | UK |
| Model | WindObserver IS |
| Instrument Type | Ultrasonic Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0 – 75 m/s |
| Accuracy | ±2% of reading |
| Operating Temperature | −30 °C to +70 °C |
| Operating Humidity | 0–100% RH |
| Certifications | ATEX II 2 G IIC T4 Ga, IECEx EXA 20.0029X, UKEX 20ATEX0002X |
| Compliance | UK CAA CAP 437, WMO Guide to Meteorological Instruments and Methods of Observation (WMO-No. 8, 7th Ed., 2008) |
| Output Options | Gill Serial Protocol, NMEA 0183, 4–20 mA (isolated), RS-485 |
| Power Supply | 12–30 VDC or 24 VAC |
| Ingress Protection | IP66 |
| Expected Service Life | >10 years in offshore environments |
| Brand | Gill |
|---|---|
| Origin | United Kingdom |
| Model | WindSonic 75 |
| Instrument Type | Ultrasonic Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0–75 m/s |
| Accuracy | ±2% of reading |
| Operating Temperature | −40 °C to +70 °C |
| Operating Humidity | 0–100% RH |
| Output Options | RS-232/RS-485 serial, dual analog (4–20 mA or 0–5 V), NMEA 0183 compliant |
| Brand | Gill |
|---|---|
| Origin | United Kingdom |
| Model | WindSonic M |
| Instrument Type | Ultrasonic Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0–60 m/s |
| Accuracy | ±2% |
| Operating Temperature | −40 °C to +70 °C |
| Operating Humidity | 0–100% RH |
| Ingress Protection | IP66 |
| Vibration Compliance | BS EN 60945:2002 |
| Impact Resistance | UL 2218 Class 1 |
| Output Protocols | NMEA 0183 (standard), Analog Output (optional) |
| Brand | Gill |
|---|---|
| Origin | United Kingdom |
| Model | WindSonic |
| Instrument Type | Ultrasonic Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0–60 m/s |
| Accuracy | ±2% @ 12 m/s |
| Operating Temperature | −35 to +70 °C |
| Relative Humidity Range | 5–100% RH |
| Output Options | RS-232/RS-485 serial, dual analog (4–20 mA or 0–5 V) |
| Status Code | Integrated diagnostic flag per data packet |
| Housing Material | UV-stabilized polycarbonate |
| Moving Parts | None |
| Compliance | IP66 rated, CE marked, RoHS compliant |
| Brand | GILL |
|---|---|
| Origin | United Kingdom |
| Model | WindSonic |
| Instrument Type | Ultrasonic Anemometer |
| Resolution | 0.01 m/s (wind speed), 1° (wind direction) |
| Measurement Range | 0–60 m/s (wind speed), 0–359° (wind direction) |
| Accuracy | ±2% @ 12 m/s (wind speed), ±3° @ 12 m/s (wind direction) |
| Response Time | 0.25 s |
| Startup Wind Speed | 0.01 m/s |
| Operating Temperature | −40 to +70 °C |
| Storage Temperature | −40 to +80 °C |
| Humidity Range | 0–100 % RH |
| IP Rating | IP65 |
| Power Supply | 5–30 V DC (varies by output option) |
| Average Time Between Failures (MTBF) | 15 years |
| Housing Material | Luran S KR 2861/1C (ASA/PC blend) |
| Dimensions | 142 mm × 160 mm |
| Weight | 0.5 kg |
| Calibration | Traceable to UK National Standards |
| EMC Compliance | EN 61326:1998 |
| Brand | Gill |
|---|---|
| Origin | United Kingdom |
| Model | WindUltra |
| Instrument Type | Ultrasonic Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0–75 m/s |
| Accuracy | ±2% of reading |
| Operating Temperature | −40 °C to +70 °C |
| Operating Humidity | 5–100% RH |
| Output Protocols | ASCII, Modbus RTU, NMEA 0183, SDI-12 |
| Heating System | User-configurable low-power resistive heater |