HSPX
Filter
Showing all 15 results
| Brand | HSPX |
|---|---|
| Origin | China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Pharmaceutical Residue Analysis |
| Temperature Control Range | Ambient +5°C to 400°C |
| Oven Ramp Rate | 0.1–39.9°C/min |
| Cool-down Time | ~6 min (from 400°C to 50°C) |
| Carrier Gas Flow Range & Control | 0–1000 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 400°C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1000 mL/min |
| Brand | HSPX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | Gas Distribution Manifold Cabinet |
| Pricing | Available Upon Request |
| Brand | HSPX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Model | GC-9100 |
| Temperature Control Range | Ambient +20 °C to 400 °C (oven, inlet, detector) |
| Ramp Rate | 0.1–40 °C/min |
| Cool-down Rate | 450 °C to 50 °C in ~6 min |
| Carrier Gas Flow Range & Control | 0–60 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.6 MPa |
| Injector Max Temp | 400 °C |
| Injector Pressure Setting Range | 0–0.6 MPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Detector Options | FID, TCD, ECD, FPD, NPD |
| Display | Color LCD with bilingual (English/Chinese) UI |
| Control Interface | PC-based software with remote operation capability |
| Automation Interfaces | Built-in driver support for autosamplers, thermal desorbers, purge-and-trap systems |
| Safety Features | Auto flame ignition, flame-out detection & re-ignition, gas leak protection, automatic gas-line initialization |
| Brand | HSPX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Scope | General-Purpose Analytical Chemistry |
| Oven Temperature Range | 4 °C to 450 °C |
| Oven Ramp Rate | 0.1–39 °C/min (Standard Mode) |
| Oven Cool-Down Time | ~6 min (from 450 °C to 50 °C) |
| Carrier Gas Flow Range & Control | 0–1000 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| FID Detection Limit | ≤3×10⁻¹² g/s (n-hexadecane in iso-octane) |
| FID Baseline Noise | ≤5×10⁻¹⁴ A |
| FID Baseline Drift | ≤1×10⁻¹³ A/30 min |
| FID Linear Dynamic Range | ≥10⁶ |
| Brand | HSPX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Scope | General-Purpose Analytical Use |
| Oven Temperature Range | Ambient + 20 °C to 400 °C |
| Ramp Rate | 0.1–40 °C/min |
| Cool-Down Time | ≤5 min (from 400 °C to 50 °C) |
| Carrier Gas Flow Range & Control | 0–1000 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Detector Temperature Range | Ambient + 20 °C to 400 °C |
| TCD Sensitivity | ≥5000 mV·mL/mg (n-heptane) |
| FID Detection Limit | <8×10⁻¹² g/s (n-decane) |
| NPD Detection Limits | ≤1×10⁻¹² g/s (N), ≤1×10⁻¹³ g/s (P) |
| FPD Detection Limits | ≤8×10⁻¹¹ g/s (S), ≤4×10⁻¹² g/s (P) |
| Column Compatibility | Packed columns (2–4 mm ID), Capillary columns (0.1–0.53 mm ID), Including Wide-Bore (0.53 mm) Systems |
| Brand | HSPX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | GC-Universal Series |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Scope | General-Purpose Analysis |
| Oven Temperature Range | Ambient + 4 °C to 450 °C (1 °C increment, ±0.01 °C accuracy) |
| Ramp Rate | 0.1–39 °C/min (Standard) |
| Cool-Down Rate | 450 °C → 50 °C in ~6 min |
| Carrier Gas Flow Control Range | 0–1000 mL/min |
| Carrier Gas Pressure Control Range | 0–970 kPa |
| Injector Max Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Column Oven Programmable Steps | 16-stage |
| Hold Time per Step | 0–655 min |
| TCD Sensitivity | ≥5000 mV·mL/mg |
| FID Detection Limit | ≤5×10⁻¹² g/s (n-decane) |
| ECD Detection Limit | ≤1×10⁻¹³ g/s (γ-BHC) |
| FPD Detection Limit | ≤5×10⁻¹³ g/s (S), ≤1.4×10⁻¹³ g/s (P) |
| NPD Detection Limit | ≤5×10⁻¹³ g/s (N) |
| Power Supply | 220 V ±10% AC, 50 ±0.5 Hz |
| Max Power Consumption | ≤1500 W |
| Dimensions (L×W×H) | 628 × 465 × 460 mm |
| Weight | 50 kg |
| Brand | HSPX |
|---|---|
| Model | HS-3 |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Output Flow Rate | 3 L/min |
| Output Pressure Range | 0–0.4 MPa |
| Hydrocarbon Content | ≤0.1 ppm (as methane equivalent) |
| Dew Point | −60 °C |
| Purification Principle | Catalytic Cracking of Hydrocarbons |
| Power Consumption | <170 W |
| Input Voltage | 220 V ±10%, 50–60 Hz |
| Dimensions (L×W×H) | 420 × 230 × 350 mm |
| Net Weight | <26 kg |
| Brand | HSPX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | HS-6D |
| Pricing | Available Upon Request |
| Flow Control | Mass Flow Controllers (MFCs) |
| Display | 7-inch Capacitive Touchscreen |
| Gas Path Materials | Passivated Stainless Steel Tubing & PTFE Tubing |
| Built-in Pump | Diaphragm Pump for Ambient-Pressure Gas Sampling |
| Dilution Range | 1:1 to 1:100 (customizable) |
| Output Channels | 6 Independent Concentration Ports |
| Operation Modes | Single-point or Multi-step Sequential Dilution |
| Method Storage | Onboard Method Library with Recall Function |
| Software Interface | Single- or Multi-channel Configuration Support |
| Brand | HSPX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HTB-3420 |
| Temperature Control Range | Ambient to 400 °C |
| Tube Capacity | 1–20 tubes |
| Temperature Setting Increment | 1 °C |
| Temperature Accuracy | ±0.5% of setpoint |
| Temperature Uniformity | ±1 °C across chamber |
| Timer Range | 0–99 h 99 min, continuously adjustable |
| Tube Compatibility | Outer diameter 6 mm (¼ inch), unlimited length |
| Brand | HSPX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Petrochemical Industry Dedicated |
| Oven Temperature Range | Ambient +5°C to 400°C |
| Oven Ramp Rate | 0.1–40°C/min |
| Oven Cool-down Time | ~6 minutes (from 450°C to 50°C) |
| Carrier Gas Flow Range & Control | 0–1000 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 400°C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1000 mL/min |
| Brand | HSPX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | Solvent Residue GC for Plastic Flexible Packaging |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Food Industry-Specific |
| Oven Temperature Range | Ambient + 5°C to 400°C |
| Ramp Rate | 0.1–40°C/min |
| Cool-down Rate | ~6 min (400°C → 50°C) |
| Carrier Gas Flow Range & Control | 0–1000 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Max Operating Temperature | 400°C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1000 mL/min |
| Brand | HSPX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | Refinery Gas-Specific GC |
| Temperature Control Range | Ambient to 400 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Cool-down Time | ~6 min (400 °C → 50 °C) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.6 MPa |
| Injector Max Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–0.6 MPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Detectors | TCD and FID |
| Column Types | Packed and Capillary |
| Multi-Valve Auto-Switching | Yes |
| Signal Auto-Switching | Yes |
| Analysis Scope | H₂, O₂, N₂, CO₂, CO, C₁–C₆₀ hydrocarbons (including C₂=–C₄= olefins and C₆⁺ saturates/olefins/aromatics) |
| Brand | HSPX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | Solvent Residue Analysis in Edible Oils, Food Additives, and Pesticide Residues |
| Oven Temperature Range | Ambient to 400 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cool-down Time | ~6 min (400 °C → 50 °C) |
| Carrier Gas Flow Control Range | 0–1200 mL/min |
| Carrier Gas Pressure Control Range | 0–0.6 MPa |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–0.6 MPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Detector | Flame Ionization Detector (FID) |
| Column Compatibility | Capillary columns for volatile organic solvent separation (e.g., DB-VRX, HP-PONA, or equivalent polar/non-polar GC columns) |
| Data System | Integrated GC workstation with peak integration, calibration curve generation, and audit-trail-capable reporting |
| Brand | HSPX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic Instrument |
| Model | Solvent Residue-Specific Gas Chromatograph |
| Price Range | USD 7,000 – 14,000 (FOB) |
| Instrument Type | Laboratory-Grade Gas Chromatograph |
| Primary Application Domain | Food Packaging Safety Testing |
| Oven Temperature Range | Ambient to 400 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cool-Down Time | ~6 min (from 400 °C to 50 °C) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.6 MPa |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–0.6 MPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Detector | Flame Ionization Detector (FID) |
| Column | Pre-configured Capillary Column for Volatile Organic Solvent Separation |
| Data System | Integrated Chromatography Workstation with Audit Trail Capability |
| Required Gases | High-Purity Nitrogen (carrier), Hydrogen (detector fuel), and Compressed Air (detector oxidant) |
| Brand | HSPX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | TDS-3410A |
| Temperature Control Range | Ambient to 400 °C |
| Gas Flow Rate | 0–300 mL/min |
| Tube Capacity | 6–10 tubes |
| Temperature Setting Increment | 1 °C |
| Temperature Stability | ±0.5% of setpoint |
| Timer Range | 0–655 minutes |
| Power Consumption | <500 W |
| Dimensions (W×D×H) | 170×390×400 mm |
| Weight | ~8 kg |