Huayisanpu
Filter
Showing all 15 results
| Brand | Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | AHS-20 |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Sample Vial Capacity | 20 positions |
| Vial Sizes Supported | 10 mL and 20 mL |
| Oven Temperature Range | Ambient to 380 °C (±0.5 °C accuracy, 1 °C increment) |
| Valve & Transfer Line Temperature Range | Ambient to 260 °C (±1 °C accuracy, 1 °C increment) |
| Loop Volume | 20 mL standard |
| Temperature Control Stability | ±0.5 °C |
| Brand | Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | AHS-50 |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automated |
| Sample Tray Capacity | 50 positions |
| Vial Size Compatibility | 10 mL and 20 mL standard crimp-top vials |
| Oven Temperature Range | Ambient to 380 °C (±0.5 °C accuracy, 1 °C increment) |
| Valve & Transfer Line Temperature Range | Ambient to 260 °C (±1 °C accuracy, 1 °C increment) |
| Quantitative Loop Volume | 1 mL |
| External Event Control Channels | 15 |
| Timing Resolution | 0.1–99 minutes (timing error <0.1%) |
| Pneumatic Actuation Pressure | <0.4 MPa (adjustable) |
| System Pressure Rating | >0.4 MPa |
| Heated Incubation Zones | 4 independent zones |
| Repeatability | RSD <1% (dependent on GC system performance and operator technique) |
| Power Requirement | <1000 VA |
| Trigger Signal Output Latency | <2 s |
| Dimensions (H×W×D) | 580 × 564 × 666 mm |
| Net Weight | ~40 kg |
| Brand | Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | AHS-6890S |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Semi-Automatic |
| Sample Vial Capacity | 9 positions |
| Vial Size | 20 mL (customizable: 10 mL, 50 mL) |
| Oven Temperature Range | Ambient to 350 °C (1 °C increment) |
| Valve & Transfer Line Temperature Range | Ambient to 180 °C (1 °C increment) |
| Temperature Accuracy | < ±0.5 °C |
| Pressure Control Range | 0–0.2 MPa (up to 0.7 MPa optional) |
| Pressure Monitoring | Digital display, 0–0.2 MPa |
| RSD for Repeatability | < 1% (GC-dependent) |
| Dimensions | 260 × 360 × 420 mm |
| Weight | ~15 kg |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Operating Environment | 10–40 °C, RH < 85% |
| Brand | Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | AHS-8890 |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Sample Tray Capacity | 20 positions |
| Vial Size | 20 mL (customizable: 10 mL, 50 mL) |
| Oven Temperature Range | Ambient to 200 °C (1 °C increment) |
| Valve & Transfer Line Temperature Range | Ambient to 180 °C / Ambient to 150 °C (1 °C increment) |
| Temperature Control Accuracy | < ±0.5 °C |
| Temperature Uniformity (Gradient) | < ±0.5 °C |
| Pressurization Range | 0–0.2 MPa (0–0.7 MPa optional) |
| Pressure Monitoring | Digital display, 0–0.2 MPa |
| RSD for Repeatability | < 1% (GC-dependent) |
| Power Supply | AC 220 V ±10%, 50 Hz ±0.5 Hz |
| Operating Environment | 10–40 °C, RH < 85% |
| Dimensions (W×D×H) | 570 × 330 × 265 mm |
| Weight | ~25 kg |
| Brand | Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | ATDS-3430 |
| Instrument Type | Single-Stage Thermal Desorber |
| Automation Level | Semi-Automatic |
| Desorption Temperature Range | Ambient to 380 °C (±0.5 °C accuracy, 1 °C increment) |
| Valve Temperature Range | Ambient to 260 °C (±1 °C) |
| Transfer Line Temperature Range | Ambient to 260 °C (±1 °C) |
| Cold Trap Temperature | Ambient |
| Temperature Stability | < ±1 °C |
| Desorption Recovery | >98% (toluene, 0.1 µL, 10:1 split ratio) |
| Peak Width (FWHM) | <3 s |
| Sample Capacity | 1 tube per run |
| Carrier Gas Flow | 0–100 mL/min (adjustable, with flow indicator) |
| Pneumatic Actuation Pressure | <0.4 MPa (adjustable) |
| System Pressure Rating | >0.4 MPa |
| Timing Resolution | 0.1–99 min (timing error <0.1%) |
| Programmable External Events | 15 |
| Power Consumption | <1000 VA |
| Dimensions (H×W×D) | 470×500×380 mm |
| Weight | ~35 kg |
| Brand | Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | ATDS-3430S |
| Automation Level | Fully Automated |
| Desorption Temperature Range | Ambient to 380 °C (±0.5 °C accuracy, 1 °C increment) |
| Valve Temperature Range | Ambient to 260 °C (±1 °C) |
| Transfer Line Temperature Range | Ambient to 260 °C (±1 °C) |
| Cold Trap Temperature | Ambient |
| Temperature Stability | < ±1 °C |
| Desorption Recovery Rate | >98% (toluene, 0.1 µL, 10:1 split ratio) |
| Peak Width (FWHM) | <3 s |
| Sample Capacity | 30 tubes |
| Programmable Events | Up to 15 |
| Event Timing Range | 0.1–99 min (<0.1% timing error) |
| Carrier Gas Flow | 0–100 mL/min (adjustable, digital indication) |
| Pneumatic Actuation Pressure | <0.4 MPa (adjustable) |
| System Pressure Rating | >0.4 MPa |
| RSD | <2.5% (GC-dependent) |
| Power Consumption | <1000 VA |
| Trigger Signal Output Delay | <2 s |
| Dimensions (H×W×D) | 470×490×450 mm |
| Weight | ~40 kg |
| Brand | Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | ATDS-3440S-II |
| Automation Level | Fully Automated |
| Primary Desorption Temp Range | Ambient to 380°C (±0.5°C accuracy, 1°C increment) |
| Secondary Desorption Temp Range | Ambient to 380°C (±0.5°C accuracy, 1°C increment, >3000°C/min ramp rate) |
| Cold Trap Temp Range | Ambient to –40°C (±1°C accuracy, 1°C increment) |
| Valve & Transfer Line Temp Range | Ambient to 260°C (±1°C accuracy, 1°C increment) |
| Sample Capacity | 40 tubes |
| Desorption Recovery | >98% (toluene, 0.1 µL, 10:1 split) |
| Peak Width (FWHM) | <3 s |
| RSD | <2.5% (system-dependent, GC and operator performance included) |
| Power Consumption | <1000 VA |
| Dimensions (H×W×D) | 470 × 490 × 450 mm |
| Weight | ~40 kg |
| Brand | Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | ATDS-4133 |
| Automation Level | Fully Automated |
| Primary Desorption Temp Range | Ambient to 380°C (±0.5°C accuracy, 1°C increment) |
| Secondary Desorption Temp Range | Ambient to 380°C (±0.5°C accuracy, 1°C increment, >3000°C/min ramp rate) |
| Cold Trap Temp Range | Ambient to −40°C (±1°C accuracy, 1°C increment) |
| Valve & Transfer Line Temp Range | Ambient to 260°C (±1°C accuracy) |
| Sample Pathway Temp Range | Ambient to 200°C (±1°C accuracy) |
| Sample Capacity | 50 tubes |
| Desorption Recovery | >98% (toluene, 0.1 µL, 10:1 split ratio) |
| Peak Width (FWHM) | <3 s |
| RSD | <2.5% |
| Tube Material | Stainless steel |
| Trap Options | Stainless steel, quartz glass, or fused silica capillary |
| Carrier Gas Flow | 0–100 mL/min (adjustable with flow indicator) |
| Pneumatic Actuation Pressure | <0.4 MPa (adjustable) |
| System Pressure Rating | >0.4 MPa |
| External Event Control | 15 programmable events |
| Event Timing Range | 0.1–99 min (<0.1% timing error) |
| Power Consumption | <1000 VA |
| GC Trigger Latency | <2 s |
| Dimensions (H×W×D) | 500 × 485 × 650 mm |
| Weight | ~45 kg |
| Brand | Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | ATDS-51 |
| Instrument Type | Dual-stage thermal desorber |
| Automation Level | Fully automated |
| Primary Desorption Temperature Range | 50–380 °C |
| Secondary Desorption Temperature Range | 150–380 °C |
| Valve & Transfer Line Temperature Range | Ambient to 260 °C |
| Cold Trap Temperature Range | Ambient to −40 °C |
| Temperature Control Accuracy | < ±0.1 °C |
| Peak Width (FWHM) | < 3 s |
| Desorption Efficiency | >98% (toluene, 0.1 µL, 10:1 split ratio) |
| Sample Capacity | 51 positions |
| Compliance | Designed for ASTM D6196, ISO 16017-1, USP <621>, and EPA TO-17 workflows |
| Brand | Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | PGA-2LB / PGA-5LB |
| Output Flow | 0–2 L/min (PGA-2LB) / 0–5 L/min (PGA-5LB) |
| Output Pressure | 0.4 MPa |
| Power Consumption | 145 W / 175 W |
| Noise Level | ≤42 dB(A) |
| Dimensions (L×W×H) | 500 × 260 × 380 mm |
| Weight | ~25 kg / ~28 kg |
| Air Purity | Oil-free, Triple-stage Purification |
| Cooling | Semiconductor-based Cold-drying System |
| Safety Features | Overpressure Protection, Thermal Cut-off, Low-pressure Soft-start, Automatic Drain Valve |
| Brand | Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Equipment Type | Nitrogen Generator |
| Nitrogen Generation Principle | Pressure Swing Adsorption (PSA) with Carbon Molecular Sieve (CMS) |
| Output Flow Rate | 0–16 L/min |
| Output Pressure | 0.1–0.4 MPa (adjustable), Max Burst Pressure >1.0 MPa |
| Nitrogen Purity | 99.0–99.99% (user-adjustable) |
| Dew Point | –40 °C to +5 °C (typical post-dryer output) |
| Power Supply | 220 V ±10%, 50 Hz |
| Rated Power | 900 W |
| Noise Level | <55 dB(A) |
| Dimensions (W×D×H) | 620 × 510 × 820 mm |
| Weight | 105 kg |
| Operating Ambient Temperature | 5–45 °C |
| Compliance | CE-marked design principles |
| compatible with ISO 8573-1 | 2010 Class 2 compressed air feed requirements |
| Brand | Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | PGN-300 |
| Nitrogen Generation Principle | Electrolytic Membrane Separation |
| Output Flow Rate | 0–300 mL/min |
| Output Pressure | 0.4 MPa |
| Nitrogen Purity | 99.999% |
| Dew Point | −10 to −40 °C |
| Input Air Pressure | 0.5 MPa |
| Power Supply | 220 V AC, 50 Hz |
| Max. Power Consumption | 80 W |
| Dimensions (L×W×H) | 385 × 180 × 360 mm |
| Net Weight | ~14 kg |
| Operating Ambient | 10–40 °C, RH < 85%, non-corrosive, low-dust environment |
| Brand | Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | PTC-100 |
| Sample Capacity | 100-position carousel |
| Injection Precision | RSD < 2.5% (GC-dependent) |
| Trap Temperature Range | Ambient to 380 °C |
| Purge Heating Temperature | Ambient to 250 °C |
| Sample Chilling Temperature | 4–10 °C |
| Cold Trap Temperature | Ambient to −40 °C |
| Water Removal Trap Temperature | Ambient to −30 °C |
| Desorption Ramp Rate | >2000 °C/min (low-voltage controlled) |
| Purge Flow Control | 0–100 mL/min, adjustable with digital readout |
| Carrier Gas Pressure Regulation | 0–0.4 MPa |
| Programmable External Events | 15 independent time-controlled functions (0.1–99 min, timing accuracy <0.1%) |
| Sample Vial Format | Standard 40 mL vials |
| System Dimensions | 580 × 640 × 850 mm (H×W×D) |
| Weight | ~50 kg |
| Power Consumption | <1000 VA |
| Interlock Signal Latency | <2 s |
| Brand | Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | PTC-50 |
| Sample Capacity | 50 positions |
| Injection Precision | RSD < 10% |
| Trap Temperature Range | Ambient to 380 °C |
| Purge Vial Heating Range | Ambient to 250 °C |
| Vial Cooling Range | 4–10 °C |
| Cold Trap Temperature Range | Ambient to −40 °C |
| Water Removal Trap Range | Ambient to −30 °C |
| Desorption Rate | >2000 °C/min |
| Water Trap Desorption Range | Ambient to 150 °C |
| Transfer Line Temperature | Ambient to 250 °C |
| Carrier Gas Pressure Regulation | 0–0.4 MPa |
| Purge Flow Rate | 0–100 mL/min |
| Trap Materials | Stainless steel / quartz / fused silica capillary (configurable) |
| Programmable External Events | 15 |
| Timing Resolution | 0.1–99 min (accuracy <0.1%) |
| Power Consumption | <1000 VA |
| Dimensions (H×W×D) | 580 × 640 × 850 mm |
| Weight | ~50 kg |
| Brand | Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | TDS-3410 |
| Temperature Range | Ambient to 400 °C |
| Gas Flow Rate | 10–250 mL/min |
| Tube Capacity | 12 tubes |
| Temperature Control Resolution | 1 °C |
| Temperature Accuracy | ±0.5% of setpoint |
| Timer Range | 0–655 min |
| Power Consumption | <500 W |
| Dimensions (W×D×H) | 170×390×400 mm |
| Weight | ~8 kg |