Inframet
Filter
Showing 61–75 of 75 results
| Brand | Inframet |
|---|---|
| Origin | Poland |
| Model | TM-6 |
| Temperature Range (TM-6L) | −50 °C to +180 °C |
| Temperature Range (TM-6M) | −50 °C to +550 °C |
| Channel Configuration | Single or Dual Channel |
| Sensor Type | PT-100 (100 Ω DIN Class A RTD) |
| Resolution | 0.001 °C |
| Measurement Uncertainty | ±0.006 °C (0 °C < T < 50 °C) |
| Display Refresh Time | 1–5 s (TM-6L), 5–10 s (TM-6M) |
| Power Supply | 230 V AC, 45–65 Hz, ≤20 W |
| Operating Ambient | +15 °C to +45 °C |
| Dimensions | 100 × 210 × 270 mm |
| Weight | 2 kg |
| Brand | Inframet |
|---|---|
| Origin | Poland |
| Model | TRAL |
| Spectral Range | 400 nm – 14,000 nm (UV–VIS–NIR–SWIR–MWIR–LWIR) |
| Radiation Sources | HB Halogen Lamp (VIS–SWIR), BB1200 Micro Blackbody (MWIR–LWIR) |
| Monochromator | MGM250 Multi-Grating |
| Modulation | OM25 Optical Chopper |
| Filter Wheel | RW-EF (Edge Filters), RW-AT (Attenuators) |
| Reference Detectors | Spectrally Matched Set |
| Software-Controlled Automation | Full PC Integration with DICO Digital Oscilloscope & Custom Test Suite |
| Brand | Inframet |
|---|---|
| Origin | Poland |
| Model | TVT |
| Light Source | Adjustable multi-spectral halogen/LED source (2856K & >5000K) |
| Spectral Range | 400–1000 nm (calibrated) |
| Illuminance Range | 30 μlx – 30 klx (DN mode) |
| Optical Configurations | Off-axis reflective collimator (100/150/200 mm aperture), refractive collimators (70 mm max aperture) |
| Target Set | 6-position USAF 1951 (variable contrast), knife-edge, distortion, grayscale targets |
| Software Suite | DAL Control, SUB-V, TAS-V, Movis |
| Supported Interfaces | GigE Vision, Camera Link, LVDS, SDI, HDMI, USB 3.0, FireWire, Analog HD, CVBS, HD-CVI, HD-TVI, AHD, CoaXPress |
| Measurement Capabilities | MTF, MRC, resolution, distortion, FOV, sensitivity, SNR, NEI, FPN, non-uniformity, 1/f noise, 3D noise, NPSD, PVF, responsivity function, linearity, dynamic range, color fidelity, bad pixel mapping |
| Calibration Traceability | NIST-traceable spectral radiance and illuminance standards |
| Compliance | ISO 12233, ISO 15739, ISO 17850, ASTM E2823, MIL-STD-810G (optical test protocols), supports GLP/GMP audit trails per FDA 21 CFR Part 11 requirements |
| Brand | Inframet |
|---|---|
| Origin | Poland |
| Model | UHT-25D-1500 |
| Temperature Range | 200–1500 °C (short-term up to 1550 °C) |
| Aperture Diameter | 25 mm |
| Emissivity | >0.99 (0.2–100+ µm) |
| Temperature Resolution | 0.1 °C (<1000 °C), 1 °C (>1000 °C) |
| Temperature Uncertainty | ±(0.15 °C + 1 °C) |
| Short-term Stability | ±1 °C |
| Long-term Stability | ±2 °C |
| Uniformity at 800 °C | ±1.5 °C |
| Warm-up Time to 1500 °C | <2.5 h |
| Control Interface | RS-232 |
| Power Supply | 230 V AC |
| Dimensions (L×W×H) | 109×39×47 cm |
| Weight | ~67 kg |
| Brand | Inframet |
|---|---|
| Origin | Poland |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | UVIC |
| Price Range | USD 105,000 – 132,000 (FOB Europe) |
| UV Channel Spectral Range | 250–275 nm |
| Visible Channel Spectral Range | 360–730 nm |
| UV Radiance Adjustment Range | 10⁻¹⁸ to 10⁻⁶ W/cm² |
| Visible Luminance Range | 0.1–300 cd/m² (≈0.3–1000 lx) |
| Target Types | Six circular apertures (Ø1.6–34 mm), four triangular targets (5–30 mm), six three-bar resolution charts (bar widths 1–5 mm), USAF 1951 visible chart (1–7.13 lp/mm), black circular reference target |
| UV Target Beam Diameter | 36 mm |
| Visible Target Aperture | 160 × 120 mm |
| System Weight | 12 kg |
| Dimensions (W×D×H) | 390 × 380 × 310 mm |
| Operating Temperature | 5–40 °C |
| Storage Temperature | −5–55 °C |
| Humidity | ≤95% RH (non-condensing) |
| Power Supply | AC 230/110 V ±10%, 50/60 Hz (DC 12 V optional) |
| Interface | RS-232 / USB 2.0 |
| Brand | Inframet |
|---|---|
| Origin | Poland |
| Model | UVIR |
| Spectral Range | 280 nm – 1700 nm |
| Optical Aperture Support | ≤100 mm (upgradable to 200 mm) |
| Light Source | XE150-A (manually adjustable, uncalibrated) or XE150-B (motorized, NIST-traceable radiometric calibration in cd/m² and W/m²) |
| Dynamic Range (Illumination) | >10⁴ (XE150-A), >10⁷ (XE150-B) |
| Collimator | CDT off-axis reflective telescope, f = 1000 mm, effective aperture = 100 mm (upgradable), FOV = 2.7°, resolution ≥100 lp/mrad, spectral coverage 0.28–15 µm |
| Target Wheel | MRW-8 motorized 8-position turret, 54 mm target diameter |
| Standard Targets | Five contrast-level USAF 1951 charts, FOV/distortion chart, knife-edge target |
| Software | TAS-A (UVIR-A), TAS-B (UVIR-B) — supports MTF, MRC, SNR, NEI, FPN, non-uniformity, responsivity, dynamic range, linearity, distortion, and field curvature analysis |
| Compliance | Designed for ISO 12233, ISO 15739, ISO 17850, ASTM E3062, and MIL-STD-150A test workflows |
| Interface Options | Analog video, Camera Link, GigE Vision, LVDS, HD-SDI, HDMI |
| Brand | Inframet |
|---|---|
| Origin | Poland |
| Model | VINIS |
| Light Source | LS-MAH Halogen Lamp (Uncalibrated, Manual Attenuation) |
| Optical Tube | CDT Series Off-Axis Reflective Collimator (Selectable Aperture & Focal Length) |
| Target Mount | Manual Target Holder (TAMAH Ring) |
| Compliance | Not NIST-traceable |
| Operating Temperature | +5°C to +35°C |
| Storage Temperature | −5°C to +55°C |
| Humidity | ≤90% RH (non-condensing) |
| Dimensions | 280 × 260 × 230 mm |
| Weight | 8 kg |
| Spectral Range | 400–2000 nm |
| Luminance Range | 60 mcd/m² to 6 kcd/m² (base configuration) |
| Dynamic Range | ≥10⁵ |
| Emission Profile | Lambertian (≤15° full angle) |
| Color Temperature | 2856 K (400–1100 nm) |
| Calibration Status | Uncalibrated (optional calibration add-ons available) |
| Brand | Inframet |
|---|---|
| Origin | Poland |
| Model | Visible Light Target |
| Target Type | Transmission-type USAF 1951 Resolution Target |
| Pattern | 3-Bar Group |
| Group Numbers | 0–7 (optional 0–8) |
| Spatial Frequency Range | 1–228 lp/mm (optional up to 456 lp/mm) |
| Contrast Ratio | 2% to 100% |
| Substrate | Soda-lime glass (quartz optional) |
| Coating | Chromium |
| Plate Dimensions | 23 × 23 mm |
| Brand | Inframet |
|---|---|
| Origin | Poland |
| Model | VIT |
| Power Supply | 230/110 VAC, 50/60 Hz |
| Max Power Consumption | <800 W |
| Operating Temperature | 10–40 °C |
| Dimensions (L×W×H) | ~163 × 63 × 73 cm |
| Weight | ~91 kg (excluding PC) |
| Modular Architecture | Dual-channel projection (radiometric + imaging), frame grabber suite, thermal/environmental chamber (optional), proprietary test software, optional CON module for bare-die sensor evaluation |
| Supported Sensor Types | Silicon-based VIS-NIR imagers, Black Silicon detectors, InGaAs SWIR focal plane arrays (FPAs) |
| Standardized Testing | EMVA 1288:2014 compliant measurements |
| Radiometric Parameters | Spectral responsivity (16 wavelengths), D*, QE, sensitivity, dynamic range, linearity, NEI, FPN, non-uniformity, SNR, dead/hot pixel count, 3D noise |
| Imaging Metrics | MTF, spatial resolution, minimum resolvable contrast (MRC), crosstalk, blooming, FOV |
| Calibration Traceability | NIST-traceable radiometric sources integrated per channel |
| Brand | Inframet |
|---|---|
| Origin | Poland |
| Model | VSB |
| Aperture Options | 50×50 mm, 100×100 mm, 150×150 mm |
| Emitter Temp. Range | −10 °C to +200 °C (at ambient < −33 °C) |
| Operating Ambient Temp. Range | −173 °C to −33 °C (optional upper limit: −28 °C) |
| Setpoint Resolution | 0.001 °C |
| Emissivity | 0.96 ± 0.01 |
| Temp. Uncertainty | ±0.07 °C or ±0.002 × (T − 25) °C |
| Spatial Uniformity | >97% (central ≥90% of aperture area) |
| Stabilization Time | <15 min (from ±1 K to ±0.1 K tolerance) |
| Heating Rate | >20 °C/min (VSB-2D/VSB-4D), >15 °C/min (VSB-6D) |
| Cooling Rate | >3 °C/min (VSB-2D/VSB-4D), >2 °C/min (VSB-6D) |
| Regulation Stability | ±0.01 °C |
| Interface | RS-485 |
| Max. Control Cable Length | 50 m |
| Power | 115–230 VAC, 50/60 Hz |
| Storage Temp. | −10 °C to +60 °C |
| Dimensions | 10×23×25 cm (VSB-2D), 15×27×35 cm (VSB-6D) |
| Brand | Inframet |
|---|---|
| Origin | Poland |
| Model | WAP1-11L |
| Spectral Range | 8–12 µm |
| FOV | 11° (circular) |
| Collimator Type | Transmissive, aspheric triplet |
| Aperture | 100 mm (66 mm optional for athermalized version) |
| Focal Length | 100 mm |
| Resolution | ≥5 lp/mrad |
| Blackbody Temperature Range | 0–100 °C |
| Temp. Control Resolution | 0.001 °C |
| Target Slider | Motorized TS3 |
| Target Set | Three 11° FOV targets (customizable) |
| Max. DUT Distance | ≤150 mm (recommended <30 mm under full FOV) |
| Operating Temperature | 15–30 °C (10–40 °C optional) |
| Weight | 12 kg |
| Brand | Inframet |
|---|---|
| Origin | Poland |
| Model | LS-MAH |
| Light Source Type | Tungsten-Halogen |
| Spectral Range | 400–2000 nm |
| Color Temperature | 2856 K (400–1100 nm) |
| Source Diameter | 40 mm |
| Luminance Adjustment Range | 60 mcd/m² to 6 kcd/m² (base version) |
| Luminance Dynamic Range | ≥10⁵ (base), ≥10⁸ (advanced, optional) |
| Intensity Control | Manual mechanical attenuator via rotary knob |
| Spectral Filtering | Manual insertion of bandpass or narrowband filters (advanced version only) |
| Emission Profile | Lambertian, ±15° half-angle |
| Operating Temperature | +5 °C to +35 °C |
| Storage Temperature | −5 °C to +55 °C |
| Relative Humidity | <90% RH (non-condensing) |
| Dimensions | 280 × 260 × 230 mm |
| Weight | 8 kg |
| Brand | Inframet |
|---|---|
| Origin | Poland |
| Model | SOL |
| Spectral Range | 400–2500 nm |
| Number of Discrete Bandpass Channels | 16 |
| Adjustable Irradiance | Continuous |
| Filter Type | Precision Narrowband Interference Filters |
| Operating Temperature | +5 °C to +35 °C |
| Storage Temperature | −5 °C to +55 °C |
| Dimensions (W×D×H) | 119 × 40 × 24 cm |
| Weight | 29.2 kg |
| Measurement Capabilities | NEI, Responsivity, Linearity, Dynamic Range, D*, Quantum Efficiency, Spatial Noise, Relative Spectral Responsivity |
| Brand | Inframet |
|---|---|
| Origin | Poland |
| Model | STR |
| Radiation Channel | Broadband Halogen Source + Spectral Selector + Radiometric Probes (RP1) |
| Imaging Channel | PC-Controlled LED + High-Resolution Projection System + Dual-Camera Image Analysis (UNI Cameras, MR1/MR2 Imaging Radiometers) |
| Temporal Channel | PC-Synchronized Pulsed Light Source + Fast Photodetector Array (FP1/FP2 + FPP1 Amplifier) |
| Measurable Parameters | Photocathode Luminous Sensitivity (Integral & Spectral), EBI, Radiant Power Gain, Luminance Gain, Dynamic Range, Spatial Resolution (16–81 lp/mm, optional 114 lp/mm), MTF, Magnification, Distortion, Afterglow Time, Temporal Resolution (optional) |
| Compatible Photocathode Diameters | 5–40 mm |
| Max Tube Height | < 480 mm |
| Max Phosphor Screen Diameter | < 56 mm |
| Spectral Range | 400–850 nm (standard), extendable |
| Photocathode Types | All standard types |
| Phosphors | P20, P22, P30, P43 (standard) |
| Mechanical OD | < 150 mm |
| MCP Integration | Supported (with/without) |
| Brand | Inframet |
|---|---|
| Origin | Poland |
| Model | VIRTEST |
| Application | MRTD (Minimum Resolvable Temperature Difference) simulation and training for thermal imaging systems |
| Target Users | R&D engineers, calibration labs, military optics trainers, infrared system validation personnel |