Ivium
Filter
Showing all 23 results
| Brand | Ivium |
|---|---|
| Origin | Netherlands |
| Model | CompactStat.h |
| Instrument Type | Portable Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±1 pA to ±10 mA (12 ranges: 1 pA, 10 pA, 100 pA, 1 nA, 10 nA, 100 nA, 1 µA, 10 µA, 100 µA, 1 mA, 10 mA) |
| Current Accuracy | ±0.2% of reading |
| Potential Accuracy | ±0.2% of reading |
| Potentiostatic Range | −10 V to +10 V |
| EIS Frequency Range | 10 µHz to 3 MHz |
| Current Resolution | down to 0.6 aA (at selected range) |
| Potential Resolution | down to 0.07 nV (at selected range) |
| Applied Signal Resolution | 0.00013% |
| Measurement Resolution (current) | 0.00006% of selected range |
| Brand | Ivium |
|---|---|
| Origin | Netherlands |
| Model | CompactStat.h |
| Instrument Type | Portable Electrochemical Workstation |
| Channel Count | Single-Channel |
| Dimensions | 12 × 26 × 2.5 cm |
| Weight | 0.6 kg |
| Power Supply | 100–240 V, 45–65 Hz, 4 VA via 12 V DC adapter |
| Interface | USB |
| PC Requirements | Windows 8/10 |
| Electrode Connections | 4-terminal (WE, CE, RE, SE) |
| Potentiostat Bandwidth | >3 MHz |
| EIS Frequency Range | 10 µHz – 3 MHz |
| Current Range | ±1 pA – ±1 A (14 decades) |
| Potential Range | ±10 V |
| Potential Resolution | 0.02 mV (20-bit @ ±10 V) |
| Current Resolution | 0.6 aA (attoampere) minimum |
| ADC | Dual-channel, 24-bit, 100,000 pts/s |
| Ohmic Drop Compensation | Up to 2 V per current range |
| Input Impedance (Electrometer) | >1000 GΩ |
| Bias Current | <10 pA |
| Analog I/O | 8 in / 2 out (±4 V, 16-bit) |
| Digital I/O | 2 in / 3 out (0–+5 V) |
| Brand | Ivium |
|---|---|
| Origin | Netherlands |
| Model | CompactStat.h10800 |
| Instrument Type | Portable Electrochemical Workstation |
| Number of Channels | Single-Channel |
| Current Range | 1 pA, 10 pA, 100 pA, 10 nA, 100 nA, 1 µA, 10 µA, 100 µA, 1 mA, 10 mA, 100 mA, 1 A (13 ranges) |
| Current Accuracy | 0.00006% of selected range, minimum 0.6 aA |
| Potential Accuracy | 0.003% of selected range, minimum 16 nV |
| Potentiostatic Range | −10 V to +10 V |
| EIS Frequency Range | 10 µHz to 3 MHz |
| Brand | Ivium |
|---|---|
| Origin | Netherlands |
| Model | CompactStat.h20250 |
| Instrument Type | Portable Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±1 pA to ±250 mA |
| Current Accuracy | ±0.2% of reading |
| Potential Accuracy | ±0.003% of range (minimum 16 nV) |
| Potentiostatic Range | −20 V to +20 V |
| Impedance Frequency Range | 10 µHz to 3 MHz |
| Potential Resolution | 0.00001% of selected range (min. 0.15 nV) |
| Current Resolution | 0.00006% of selected range (min. 0.6 aA) |
| Applied Current Resolution | 0.00013% |
| Applied Potential Resolution | 16 nV |
| Brand | Ivium |
|---|---|
| Origin | Netherlands |
| Model | Current Interrupt Module |
| Instrument Type | Electrochemical Instrument Accessory |
| Application | iR Compensation via Current Interruption Method |
| Connectivity | Direct integration with Ivium potentiostat electrode cable assemblies |
| Compliance Context | Designed for use in ASTM G102-compliant corrosion testing and ISO 17475 electrochemical impedance validation workflows |
| Key | Brand: Ivium |
|---|---|
| Origin | Netherlands |
| Model | HE80 |
| Channel Count | Single-Channel |
| Current Range | 0–80 A |
| Current Accuracy | ±0.3 mA |
| Potential Accuracy | ±14 nV |
| Potentiostatic Range | +0.5 V to +20 V |
| EIS Frequency Range | 10 µHz–10 kHz |
| Maximum Data Acquisition Rate | 300,000 pts/s |
| Minimum Time Interval | 3.33 µs (0.125 µs resolution) |
| Real-Time Sampling Rate | Up to 500 pts/s |
| Dimensions | 44 × 37 × 8.8 cm |
| Weight | 15 kg |
| Electrode Configuration | 4-Electrode Connection |
| Integrated FRA/EIS | Yes |
| Brand | Ivium |
|---|---|
| Origin | Netherlands |
| Model | HiMUX.XR |
| Instrument Type | Electrochemical Sample Switcher |
| Channel Capacity | 8 independent channels |
| Max Current (WE–CE) | 5 A |
| Electrode Configuration per Channel | 4-electrode (WE, CE, RE, SE) |
| Compatible Systems | IviumStat, CompactStat series |
| Independent Galvanostats per Channel | Yes |
| Leakage Capacitance | Ultra-low |
| High-Frequency Performance | Uncompromised |
| Software Control | Automatic channel selection integrated in IviumSoft |
| Brand | Ivium |
|---|---|
| Origin | Netherlands |
| Model | IviCycle C030/C200 |
| Channels | 32 (4×8-module rack-mount configuration) |
| Voltage Range | ±10 V |
| Current Range | ±30 mA / ±200 mA |
| Potentiostat Bandwidth | >500 kHz |
| ADC Resolution | 16-bit dual-channel |
| Sampling Rate | 100 kpts/s |
| EIS Frequency Range | 10 µHz – 20 kHz |
| Data Storage | 20 million points/channel (on-board SD card) |
| Compliance | CE, RoHS |
| Interface | USB 2.0, Ethernet (LAN) |
| PC OS | Windows 10 |
| Dimensions | 44 × 26 × 22 cm |
| Weight | 12.5 kg |
| Brand | Ivium |
|---|---|
| Origin | Netherlands |
| Model | IviumBoost |
| Type | Electrochemical Instrument Accessory |
| Output Voltage/Current/Frequency Ranges | IviumBoost1001 — 100 V / 0.5 A / 250 kHz |
| Brand | Ivium |
|---|---|
| Origin | Netherlands |
| Model | IVIUMSTAT.H |
| Channel Count | Single-Channel |
| Current Range | 10 nA – 10 A |
| Current Accuracy | ±0.2% |
| Potential Accuracy | ±0.2% |
| Potentiostatic Range | ±1 mV, ±10 mV, ±100 mV, ±1 V, ±10 V |
| EIS Frequency Range | 10 µHz – 8 MHz |
| Brand | Ivium |
|---|---|
| Origin | Netherlands |
| Model | Modulight |
| Light Source Type | Infrared-capable LED-based modular light source |
| Illumination Mode | External illumination |
| Spectral Output | 7 standard channels (460–740 nm + 5500K white) + 4 optional channels (365 nm, 400 nm, 4000K natural white, 3100K warm white) |
| Intensity Control | Software-controlled DC or sinusoidally modulated (10 µHz – 2 MHz) |
| Compliance | Designed for integration with Ivium electrochemical workstations (e.g., Stat, Vertex, CompactStat series) and compatible with ISO/IEC 17025-aligned electro-optical testing workflows |
| Brand | Ivium |
|---|---|
| Origin | Netherlands |
| Model | MultiWE32 |
| Electrode Channel Capacity | 32 working electrodes (expandable to 256) |
| Compatible Systems | Ivium potentiostats/galvanostats |
| Measurement Modes | Simultaneous LSV, CV, and EIS on all channels |
| Reference/Counter Electrode Configuration | Shared RE/CE pair |
| Compliance | Designed for ISO/IEC 17025-compliant electrochemical labs |
| Brand | Ivium |
|---|---|
| Origin | Netherlands |
| Model | Octo Stat |
| Max Current per Channel | ±200 mA / ±5 A (selectable) |
| Max Voltage | ±10 V |
| Current Range | ±10 nA to ±100 mA (standard), extendable to ±10 A |
| EIS Frequency Range | 10 µHz – 100 kHz |
| Onboard Data Storage | 20 million data points per channel |
| Interface | USB 2.0 & 10/100 Mbps Ethernet |
| Rack Mount | 19-inch standard |
| Standalone Operation | Yes (fully embedded control firmware) |
| Software | IviumSoft (battery cycling, EIS, polarization, corrosion analysis modules) |
| Brand | Ivium |
|---|---|
| Origin | Netherlands |
| Model | Peripheral Differential Amplifier |
| Input Impedance | >1000 GΩ |
| Differential Input Range | ±2 V |
| Channels per Module | 8 |
| Expandable to | 64 channels |
| Instrument Type | Electrochemical Instrument Accessory |
| Category | Electrochemical Instrument Accessories |
| Brand | Ivium |
|---|---|
| Origin | Netherlands |
| Model | Peripheral Port Expander |
| Type | Electrochemical Instrument Accessory |
| Function | External Signal I/O Expansion Module |
| Analog Inputs | 8 channels |
| Analog Outputs | 2 channels |
| Digital Inputs | 2 channels |
| Digital Outputs | 3 channels |
| Dedicated Outputs | Current (I-out), Potential (E-out), AC Output (ACout) |
| Impedance Input Channels | X and Y (for lock-in or phase-sensitive detection) |
| Connector Type | Standard BNC and screw-terminal interfaces |
| Compatibility | Designed exclusively for Ivium electrochemical workstations (e.g., IviumStat, CompactStat, Vertex series) |
| Brand | Ivium |
|---|---|
| Origin | Netherlands |
| Model | pocketSTAT |
| Instrument Type | Portable Electrochemical Workstation |
| Number of Channels | Single-Channel |
| Current Range | 1 nA, 10 nA, 100 nA, 1 µA, 10 µA, 100 µA, 1 mA, 10 mA |
| Current Accuracy | 0.015% of full scale per range (minimum resolution: 0.15 pA) |
| Potential Accuracy | 0.2% of full scale |
| Potentiostatic Range | −4 V to +4 V |
| AC Impedance Frequency Range | 10 µHz to 100 kHz |
| Brand | Ivium |
|---|---|
| Origin | Netherlands |
| Model | IVIUM RDE/RRDE |
| Rotation Speed Range | 100–10,000 rpm |
| Speed Control | Analog voltage input (0–10 V DC) |
| Speed Resolution | 0.02 rpm (average) |
| Output Signal | 0–10 V DC proportional to rotational speed |
| Drive Architecture | High-acceleration brushless DC motor |
| Electrode Mounting | Chemically inert PEEK housing |
| Power Supply | Bipolar ±15 V DC for enhanced electrochemical kinetics |
| Application Domain | Hydrodynamic modulation voltammetry, kinetic studies, mass-transport-controlled electroanalysis |
| Brand | Ivium |
|---|---|
| Origin | Netherlands |
| Model | n-Stat |
| Instrument Type | Electrochemical Workstation |
| Channel Count | Up to 64 (8 per unit, stackable) |
| Current Range | ±10 nA to ±10 A |
| Current Resolution | 1 pA |
| Potential Accuracy | ±1 mV |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 µHz to 1 MHz |
| Data Acquisition Rate | 100 kHz |
| Analog/Digital I/O | Multiple isolated inputs/outputs |
| Max. Power Output | ±40 A @ ±10 V (expandable) |
| Compliance Standards | CE, RoHS, ISO/IEC 17025-compatible operation |
| Brand | Ivium |
|---|---|
| Origin | Netherlands |
| Model | Vertex |
| Instrument Type | Portable Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±100 nA to ±10 A (configurable up to 10 A) |
| Current Accuracy | 0.015% of full scale per range, minimum resolution 15 pA |
| Potential Accuracy | 0.3% of full scale |
| Potentiostatic Range | −10 V to +10 V (extended options: ±20 V) |
| EIS Frequency Range | 10 µHz to 1 MHz (optional) |
| Brand | Ivium |
|---|---|
| Origin | Netherlands |
| Model | Vertex.100mA.EIS |
| Channel Count | Single-Channel |
| Current Range | 100 nA – 100 mA |
| Current Accuracy | ±0.3% |
| Potential Accuracy | ±0.3% |
| Potentiostat Bandwidth | >500 kHz |
| EIS Frequency Range | 10 µHz – 1 MHz |
| Brand | Ivium |
|---|---|
| Origin | Netherlands |
| Model | Vertex.One.EIS |
| Instrument Type | Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±100 mA / ±350 mA |
| Current Accuracy | ±0.2% |
| Potential Accuracy | ±0.2% |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 µHz – 250 kHz / 1 MHz |
| Data Acquisition Rate | 100 kHz |
| Current Resolution | Down to 10 fA |
| Current Range Span | 100 pA – 1 A |
| Floating Ground Capability | Yes |
| Dual-Potentiostat Configuration | Supported (two units) |
| Multi-Channel Expansion | Supported (multiple units) |
| Brand | Ivium |
|---|---|
| Origin | Netherlands |
| Model | Ivium-n-Stat |
| Instrument Type | Electrochemical Workstation |
| Channel Count | Up to 256 (via modular stacking) |
| Current Range | Standard: ±10 nA to ±10 A (10 decades) |
| Extended | ±10 pA to ±10 A (13 decades) |
| Current Resolution | Down to 1 fA (in 10 pA range) |
| Current Accuracy | ±0.015% of full scale per range |
| Potential Accuracy | ±0.2% or ±2 mV |
| Potentiostatic Range | −10 V to +10 V (extendable to ±20 V, ±40 V, ±100 V with auxiliary modules) |
| EIS Frequency Range | 10 µHz – 250 kHz (extendable to 1 MHz) |
| Data Acquisition Rate | Up to 100 kHz |
| Integrated Impedance Analyzer per Channel | Yes |
| Analog I/O Interfaces | Multiple isolated analog inputs/outputs for external device synchronization |
| Brand | Ivium |
|---|---|
| Origin | Netherlands |
| Model | iviumstat.h |
| Channel Count | Single-Channel |
| Current Range | ±5 A |
| Current Accuracy | ±0.2% |
| Potential Accuracy | ±1 mV |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 µHz – 8 MHz |
| Current Resolution | 0.6 aA (at 1 pA range) |
| Potential Resolution | 0.15 nV |
| Sampling Rate (Standard) | 100 kHz (10 µs interval) |
| EIS High-Frequency Capability | Up to 8 MHz for solid-state impedance characterization |
| Input Impedance (HiZ module) | >10¹⁵ Ω |
| Bias Current (HiZ) | 3 fA |
| Wireless Connectivity | Integrated Wi-Fi module with SD card data logging |
| Cloud Integration | Ivium Cloud remote access and instrument control via web browser |
| Temperature Monitoring | K-type thermocouple support (TCM-K module) |
| Photoelectrochemical Options | ModuLight LED source (365–940 nm), iviSun solar simulator (1075 W/m², AM1.5G compliant) |
| Expandability | BiStat (dual potentiostat), MultiWE32 (32-electrode multiplexer), QCM/E-QCM, SPR/E-SPR, RDE/RRDE control |