KANOMAX
Filter
Showing 31–60 of 500 results
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 3715-06D |
| Flow Rate | 2.83 L/min (0.1 CFM) |
| Particle Size Channels | 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 µm |
| Light Source | Long-life Laser Diode |
| Counting Efficiency | Compliant with ISO 21501-4 and JIS B 9921 |
| Maximum Detectable Concentration | 2,000,000 counts/ft³ |
| Communication Protocols | RS-485, Modbus RTU/TCP/IP |
| Data Storage Capacity | 4,320 records |
| Power Options | DC 12–24 V, AC 100–240 V, PoE, or DC battery |
| Operating Temperature | 10–30 °C |
| Operating Humidity | 20–85% RH (non-condensing) |
| Dimensions | 217 × 69 × 110 mm |
| Weight | 1.4 kg |
| Vacuum Pump Lifetime | 8,000 h |
| MTBF | ≥10 years |
| Warranty | 3 years |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 3715-06D |
| Flow Rate | 2.83 L/min (0.1 CFM) |
| Particle Size Channels | 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 µm |
| Light Source | Long-life Laser Diode |
| Counting Efficiency | Compliant with ISO 21501-4 and JIS B 9921 |
| Max. Detectable Concentration | 2,000,000 counts/ft³ |
| Communication Protocols | RS-485, Modbus RTU/TCP/IP |
| Data Storage Capacity | 4,320 records |
| Power Options | DC 12–24 V, AC 100–240 V, PoE, or External DC Supply |
| Operating Temperature | 10–30 °C |
| Operating Humidity | 20–85% RH (non-condensing) |
| Dimensions | 217 × 69 × 110 mm |
| Weight | 1.4 kg |
| Built-in Vacuum Pump Life | 8,000 h |
| MTBF | ≥10 years |
| Warranty | 3 years |
| Brand | Kanomax |
|---|---|
| Model | 3715-06D |
| Particle Size Channels | 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 µm |
| Flow Rate | 2.83 L/min (0.1 CFM) |
| Light Source | Long-life Laser Diode |
| Counting Efficiency | Compliant with ISO 21501-4 and JIS B9921 |
| Max Concentration | 2,000,000 counts/ft³ |
| Communication Protocols | RS485, Modbus RTU/TCP/IP |
| Data Storage Capacity | 4,320 records |
| Power Options | DC 12–24 V, AC 100–240 V, PoE, or DC adapter |
| Operating Temperature | 10–30 °C |
| Operating Humidity | 20–85% RH (non-condensing) |
| Dimensions | 217 × 69 × 110 mm |
| Weight | 1.4 kg |
| Internal Vacuum Pump Life | 8,000 h |
| MTBF | ≥10 years |
| Warranty | 3 years |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 3715-06D |
| Flow Rate | 2.83 L/min (0.1 CFM) |
| Particle Size Channels | 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 µm |
| Light Source | Long-life Laser Diode |
| Counting Efficiency | Compliant with ISO 21501-4 and JIS B 9921 |
| Max. Detectable Concentration | 2,000,000 counts/ft³ |
| Communication Protocols | RS-485, Modbus RTU/TCP/IP |
| Data Storage Capacity | 4,320 records |
| Power Options | DC 12–24 V, AC 100–240 V, PoE, or DC battery |
| Operating Temperature | 10–30 °C |
| Operating Humidity | 20–85 %RH (non-condensing) |
| Dimensions | 217 × 69 × 110 mm |
| Weight | 1.4 kg |
| MTBF | ≥10 years |
| Vacuum Pump Lifetime | 8,000 h |
| Display | 4.3-inch capacitive touchscreen |
| Optional Sensors | Integrated temperature & humidity probe |
| Wi-Fi Base Station Support | Yes |
| Environmental Rating | Corrosion-resistant, steam-resistant housing |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3715-06D |
| Flow Rate | 2.83 L/min (0.1 CFM) |
| Particle Size Channels | 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 µm |
| Light Source | Long-life laser diode |
| Counting Efficiency | Compliant with ISO 21501-4 and JIS B 9921 |
| Max. Detectable Concentration | 2,000,000 counts/ft³ |
| Communication Protocols | RS-485, Modbus RTU/TCP/IP |
| Data Storage Capacity | 4,320 records |
| Power Options | DC 12–24 V, AC 100–240 V, PoE, or external DC supply |
| Operating Temperature | 10–30 °C |
| Operating Humidity | 20–85% RH (non-condensing) |
| Dimensions | 217 × 69 × 110 mm |
| Weight | 1.4 kg |
| Built-in Vacuum Pump Lifetime | 8,000 h |
| MTBF | ≥10 years |
| Warranty | 3 years |
| Brand | Kanomax |
|---|---|
| Origin | USA |
| Model | 3715-06D |
| Particle Size Channels | 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 µm |
| Flow Rate | 2.83 L/min (0.1 CFM) |
| Light Source | Long-life laser diode |
| Counting Efficiency | Compliant with ISO 21501-4 and JIS B 9921 |
| Maximum Detectable Concentration | 2,000,000 counts/ft³ |
| Communication Protocols | RS-485, Modbus RTU/TCP/IP |
| Data Storage Capacity | 4,320 records |
| Built-in Vacuum Source Lifetime | 8,000 hours |
| Operating Temperature | 10–30 °C |
| Operating Humidity | 20–85% RH (non-condensing) |
| Power Supply | DC 12–24 V / AC 100–240 V / PoE |
| Dimensions | 217 × 69 × 110 mm |
| Weight | 1.4 kg |
| Display | 4.3-inch capacitive touchscreen |
| Optional Sensors | Integrated temperature & humidity probe |
| Environmental Rating | Sterilization-resistant housing (VHP/H₂O₂ compatible) |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 3715-06D |
| Flow Rate | 2.83 L/min (0.1 CFM) |
| Particle Size Channels | 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 µm |
| Light Source | Long-Life Laser Diode |
| Counting Efficiency | Compliant with ISO 21501-4 and JIS B9921 |
| Max. Detectable Concentration | 2,000,000 counts/ft³ |
| Data Storage Capacity | 4,320 records |
| Communication Protocols | RS-485, Modbus RTU/TCP/IP |
| Power Options | DC 12–24 V, AC 100–240 V, PoE, or External DC Supply |
| Operating Temperature | 10–30 °C |
| Operating Humidity | 20–85 %RH (non-condensing) |
| Dimensions | 217 × 69 × 110 mm |
| Weight | 1.4 kg |
| Built-in Vacuum Pump Lifetime | 8,000 h |
| MTBF | ≥10 years |
| Warranty | 3 years |
| Brand | Kanomax |
|---|---|
| Origin | China (Liaoning) |
| Model | 3718-A / 3719-A |
| Flow Rate | 28.3 L/min (1 CFM) |
| Particle Size Channels | 0.3 & 0.5 µm (3718-A) or 0.5 & 5.0 µm (3719-A) |
| Light Source | Long-life Laser Diode |
| Compliance | ISO 21501-4, JIS B 9921, ISO 14644-1:2015 |
| Data Storage | 2,000 Sample Records with Redundant Backup |
| Output Interfaces | RS485, Modbus RTU/TCP/IP, 4–20 mA Analog |
| Power Supply | DC 9–28 V, PoE, or AC 100–240 V |
| Enclosure Material | 316 Stainless Steel with VHP/Alcohol Vapor Resistance |
| Operating Environment | 10–30 °C, 20–85% RH (non-condensing) |
| Dimensions | 133 × 95 × 80 mm |
| Weight | 1.0 kg |
| Brand | KANOMAX |
|---|---|
| Origin | Liaoning, China |
| Model | 3718-A / 3719-A |
| Instrument Type | Online Particle Counter |
| Flow Rate | 28.3 L/min (1 CFM) |
| Particle Size Channels | 0.3 & 0.5 µm (3718-A) / 0.5 & 5.0 µm (3719-A) |
| Light Source | Long-life Laser Diode |
| Compliance | ISO 21501-4, JIS B 9921, ISO 14644-1:2015 |
| Data Storage | 2,000 Sample Records with Redundant Backup |
| Output Interfaces | RS485, Modbus RTU/TCP/IP, 4–20 mA Analog |
| Power Supply | DC 9–28 V, PoE, or AC 100–240 V |
| Enclosure Material | 316 Stainless Steel with VHP/Alcohol Vapor Resistance |
| Operating Environment | 10–30 °C, 20–85% RH (non-condensing) |
| Dimensions | 133 × 95 × 80 mm |
| Weight | 1.0 kg |
| Brand | KANOMAX |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Product Type | Online Particle Counter |
| Flow Rate | 28.3 L/min (1 CFM) |
| Particle Size Channels | 3718-A: 0.3 & 0.5 µm |
| 3719-A | 0.5 & 5.0 µm |
| Light Source | Long-life Laser Diode |
| Compliance | ISO 21501-4, JIS B 9921, ISO 14644-1:2015 |
| Data Storage | 2,000 buffered records with redundancy backup |
| Output Interfaces | RS-485, Modbus RTU/TCP/IP, 4–20 mA analog |
| Power | DC 9–28 V, PoE, or AC 100–240 V |
| Housing | 316 Stainless Steel with VHP/ethanol vapor resistance |
| Operating Environment | 10–30 °C, 20–85% RH (non-condensing) |
| Dimensions | 133 × 95 × 80 mm |
| Weight | 1.0 kg |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 3718-A / 3719-A |
| Particle Size Channels | 0.3 & 0.5 µm (3718-A) / 0.5 & 5.0 µm (3719-A) |
| Flow Rate | 28.3 L/min (1 CFM) |
| Light Source | Long-life laser diode |
| Counting Efficiency | Compliant with ISO 21501-4 and JIS B 9921 |
| Max Concentration | 500,000 counts/ft³ |
| Data Storage | 4,320 measurement records with redundancy backup |
| Output Interfaces | RS485, Modbus RTU/TCP/IP, 4–20 mA analog output |
| Power Supply | DC 9–28 V, PoE, or AC 100–240 V |
| Housing Material | 316 stainless steel with VHP- and alcohol vapor-resistant sealing |
| Operating Environment | 10–30 °C, 20–85% RH (non-condensing) |
| Dimensions | 133 × 95 × 80 mm |
| Weight | 1.0 kg |
| Compliance | ISO 14644-1:2015, JIS B 9921, ISO 21501-4 |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 3720-06 |
| Instrument Type | Online Particle Counter |
| Flow Rate | 28.3 L/min (1.0 CFM) |
| Detectable Particle Sizes | 0.3, 0.5, 0.7, 1.0, 3.0, 5.0, 10.0 µm (2–4 sizes configurable at factory) |
| Light Source | Long-life Class II laser diode |
| Counting Efficiency | Compliant with ISO 21501-4 and JIS B9921 |
| Max. Concentration | 1,000,000 counts/ft³ |
| Data Storage | 5,000 full measurement records + 4,320 buffered samples |
| Output Interfaces | Ethernet, RS-485, 4–20 mA analog, Modbus RTU/TCP |
| Power Supply | DC 15–28 V, PoE (IEEE 802.3af), or AC 100–240 V |
| Housing Material | 316 stainless steel with VHP- and alcohol vapor-resistant sealed enclosure |
| Operating Environment | 10–30 °C, 20–85% RH (non-condensing) |
| Dimensions | 180 × 110 × 19 mm |
| Weight | 4.0 kg |
| Brand | Kanomax |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | 3720-06+ |
| Price | Upon Request |
| Particle Size Channels | Selectable 2–4 from 0.3, 0.5, 0.7, 1.0, 3.0, 5.0, 10.0 µm (standard configuration: 0.5 & 5.0 µm) |
| Flow Rate | 28.3 L/min (1.0 CFM) |
| Light Source | Long-life laser diode |
| Counting Efficiency | Compliant with ISO 21501-4 and JIS B 9921 |
| Max. Detectable Concentration | 1,000,000 counts/ft³ |
| Data Storage | 5,000 full test records + 2,000-buffered real-time samples with redundancy backup |
| Housing Material | 316 stainless steel enclosure with VHP- and ethanol vapor-resistant sealing |
| Vacuum Sampling Pump | Removable, modular design |
| Power Supply | DC 15–28 V / PoE (IEEE 802.3af) / AC 100–240 V |
| Communication | Ethernet (Modbus TCP/IP), RS-485 (Modbus RTU), 4–20 mA analog output |
| Operating Environment | 10–30 °C, 20–85% RH (non-condensing) |
| Dimensions | 180 × 110 × 190 mm |
| Weight | 4.0 kg |
| Brand | KANOMAX |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | 3720-06 |
| Price | Upon Request |
| Particle Size Channels | Selectable 2–4 channels from 0.3, 0.5, 0.7, 1.0, 3.0, 5.0, 10.0 µm (standard configuration: 0.5 & 5.0 µm) |
| Flow Rate | 28.3 L/min (1.0 CFM) |
| Light Source | Long-life Class II laser diode |
| Counting Efficiency | Compliant with ISO 21501-4 and JIS B9921 |
| Maximum Detectable Concentration | 1,000,000 counts/ft³ |
| Data Storage | 5,000 measurement records (2,000 in volatile buffer with redundancy) |
| Output Options | Modbus RTU/TCP/IP over RS-485/Ethernet |
| Power Supply | DC 15–28 V, PoE (IEEE 802.3af), or AC 100–240 V |
| Enclosure Material | 316 stainless steel with VHP- and ethanol vapor-resistant sealing |
| Vacuum Pump | Removable, serviceable vacuum sampling pump |
| Operating Environment | 10–30 °C, 20–85% RH (non-condensing) |
| Storage Conditions | −10–50 °C, ≤95% RH (non-condensing) |
| Dimensions | 180 × 110 × 190 mm |
| Weight | 4.0 kg |
| MTBF | ≥10 years |
| Warranty | 3 years |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3886 |
| Instrument Type | Handheld |
| Flow Rate | Low-flow (0.1 CFM / 2.83 L/min) |
| Flow Accuracy | < ±1 particle per 5 minutes |
| Timing Accuracy | < ±1 s over 6-minute sampling |
| Repeatability | ≤ ±10% FS |
| Size Distribution Error | ≤ ±30% |
| Indication Error | ≤ ±30% FS |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | KANOMAX 3886 |
| Instrument Type | Handheld |
| Flow Rate | Low-flow (2.83 L/min) |
| Flow Accuracy | < ±1 particle per 5 min |
| Timing Accuracy | < ±1 s over 6-min sampling |
| Repeatability | ≤ ±10% FS |
| Size Distribution Error | ≤ ±30% |
| Indication Error | ≤ ±30% FS |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | KANOMAX 3887 |
| Flow Rate | 2.83 L/min |
| Particle Size Channels | 0.3, 0.5, and 5.0 µm (user-selectable) |
| Flow Accuracy | < ±1 particle per 5 min |
| Timing Accuracy | < ±1 s over 6-min sampling |
| Repeatability | ≤ ±10% FS |
| Size Distribution Error | ≤ ±30% |
| Indication Error | ≤ ±30% FS |
| Compliance | GB/T 16292–2010, ISO 14644-1, China GMP (2010) |
| Data Storage | High-capacity internal memory with statistical analysis |
| Power Management | Auto-save on power interruption |
| Display | Backlit LCD with English interface |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3887 |
| Instrument Type | Handheld |
| Flow Rate | 2.83 L/min |
| Flow Accuracy | <1 particle/5 min |
| Timing Error | <±1 s over 6-min sampling |
| Repeatability | ≤±10% FS |
| Size Distribution Error | ≤±30% |
| Indication Error | ≤±30% FS |
| Selectable Channel Sizes | 0.3, 0.5, and 5.0 µm |
| Compliance | GB/T 16292–2010, ISO 14644-1, China GMP (2010) |
| Data Storage | Internal high-capacity memory with statistical analysis |
| Power Management | Auto-save on power interruption |
| Display | Backlit English-language LCD interface |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3887C |
| Instrument Type | Handheld |
| Flow Rate | 2.83 L/min (0.1 cfm) |
| Flow Accuracy | < ±1 particle per 5 min |
| Timing Accuracy | ±1 s within 6-min sampling |
| Repeatability | ≤ ±10% FS |
| Size Distribution Error | ≤ ±30% |
| Indication Error | ≤ ±30% FS |
| Particle Size Channels | 0.3, 0.5, and 5.0 µm |
| Data Storage Capacity | 7,000 records |
| Sampling Duration | 10 sec to 99 min 59 sec |
| Sampling Modes | Single, Repeat, Continuous, Calculate, Remote, International, ISO (3887C/D only) |
| Count Alarm Range | 1–70,000,000 particles |
| Power Supply | 4× AA batteries (alkaline or Ni-MH), or AC adapter (100–240 V AC) |
| Dimensions | 108(W) × 68(D) × 196(H) mm |
| Weight | ~680 g (without batteries) |
| Compliance | GB/T 16292–2010, ISO 14644-1, China GMP (2010) Annex 1 |
| Brand | Kanomax |
|---|---|
| Origin | China (Liaoning) |
| Model | 3887C |
| Instrument Type | Handheld Particle Counter |
| Sampling Flow Rate | 2.83 L/min (0.1 cfm) |
| Detectable Particle Sizes | 0.3, 0.5, 5.0 µm |
| Compliance Standards | GB/T 16292–2010, ISO 14644-1, China GMP (2010) |
| Data Storage Capacity | 7,000 records |
| Operating Power | 4×AA Ni-MH rechargeable batteries or AC adapter (100–240 V AC) |
| Dimensions | 108(W) × 68(D) × 196(H) mm |
| Weight | ~680 g (without batteries) |
| Test Modes | Single, Repeat, Continuous, Calculate, Remote, International, ISO (3887C/D only) |
| Sampling Duration | 10 sec – 99 min 59 sec |
| Count Alarm Range | 1 – 70,000,000 particles/ft³ |
| User Interface | Chinese-language LCD display |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3887C |
| Instrument Type | Handheld |
| Flow Rate | 2.83 L/min |
| Flow Accuracy | < ±1 particle per 5 min |
| Timing Accuracy | < ±1 s over 6-min sampling |
| Repeatability | ≤ ±10% FS |
| Size Distribution Error | ≤ ±30% |
| Indication Error | ≤ ±30% FS |
| Particle Size Channels | 0.3, 0.5, and 5.0 µm (user-selectable) |
| Compliance | GB/T 16292–2010, ISO 14644-1, China GMP (2010) |
| Data Storage | High-capacity internal memory with statistical reporting |
| Power Management | Auto-save on power interruption |
| Display | Backlit LCD with full Chinese UI |
| Brand | Kanomax |
|---|---|
| Origin | Imported (Japan) |
| Model | 3887C |
| Instrument Type | Handheld |
| Flow Rate | 2.83 L/min |
| Flow Accuracy | < ±1 particle per 5 min |
| Timing Accuracy | < ±1 s over 6-min sampling |
| Repeatability | ≤ ±10% FS |
| Size Distribution Error | ≤ ±30% |
| Indication Error | ≤ ±30% FS |
| Selectable Channel Sizes | 0.3, 0.5, and 5.0 µm |
| Compliance | GB/T 16292–2010, ISO 14644-1:2015, China GMP (2010) Annex 1 |
| Data Storage | Internal high-capacity flash memory with statistical analysis |
| Power Management | Auto-save on power interruption |
| Display | Backlit monochrome LCD with full Chinese UI |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 3887C |
| Instrument Type | Handheld |
| Flow Rate | 2.83 L/min |
| Flow Accuracy | <1 particle per 5 min |
| Timing Accuracy | ±1 s within 6-min sampling |
| Repeatability | ≤±10% FS |
| Size Distribution Error | ≤±30% |
| Indication Error | ≤±30% FS |
| Selectable Particle Sizes | 0.3, 0.5, and 5.0 µm |
| Compliance Standards | GB/T 16292–2010, ISO 14644-1, China GMP (2010) |
| Data Storage | High-capacity internal memory with statistical analysis |
| Features | Backlit LCD, programmable delay start, power-loss auto-save & resume, multi-mode operation (GBMODE, GMP, ISO) |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | KANOMAX 3887D |
| Instrument Type | Handheld |
| Flow Rate | 2.83 L/min |
| Flow Accuracy | < ±1 particle per 5 min |
| Timing Accuracy | < ±1 s over 6-min sampling |
| Repeatability | ≤ ±10% FS |
| Size Distribution Error | ≤ ±30% |
| Indication Error | ≤ ±30% FS |
| Particle Size Channels | 0.3, 0.5, 1.0, 3.0, 5.0 µm (user-selectable) |
| Compliance Standards | GB/T 16292–2010, ISO 14644-1, China GMP (2010) |
| Data Storage | High-capacity internal memory with statistical analysis |
| Power Management | Auto-save on power interruption |
| Interface | Full Chinese GUI |
| Backlight | Adjustable high-brightness LCD |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3887D |
| Instrument Type | Handheld |
| Flow Rate | 2.83 L/min |
| Flow Accuracy | <1 particle/5 min |
| Timing Accuracy | ±1 s within 6-min sampling |
| Repeatability | ≤±10% FS |
| Size Distribution Error | ≤±30% |
| Indication Error | ≤±30% FS |
| Particle Size Channels | 0.3, 0.5, 1.0, 3.0, 5.0 µm (selectable) |
| Compliance | GB/T 16292–2010, ISO 14644-1, China GMP (2010) |
| Data Storage | High-capacity internal memory with statistical analysis |
| Power Management | Auto-save on power interruption |
| Display | Backlit Chinese-language interface |
| Sampling Delay | Programmable to minimize operator-induced contamination |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3887D |
| Instrument Type | Handheld Particle Counter |
| Flow Rate | 2.83 L/min (0.1 cfm) |
| Flow Accuracy | < ±1 particle per 5 min |
| Timing Accuracy | ±1 s within 6-min sampling |
| Repeatability | ≤ ±10% FS |
| Size Distribution Error | ≤ ±30% |
| Indication Error | ≤ ±30% FS |
| Particle Size Channels | 0.3, 0.5, 1.0, 3.0, 5.0 µm |
| Sampling Duration | 10 sec – 99 min 59 sec |
| Data Storage Capacity | 7,000 records |
| Power Supply | 4×AA Ni-MH rechargeable batteries or AC adapter (100–240 V AC) |
| Dimensions | 108(W) × 68(D) × 196(H) mm |
| Weight | ~680 g (without batteries) |
| Compliance Standards | ISO 14644-1, GB/T 16292–2010, China GMP (2010) Annex 1 |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3887D |
| Instrument Type | Handheld |
| Flow Rate | 2.83 L/min (0.1 cfm) |
| Flow Accuracy | < ±1 particle/5 min |
| Timing Accuracy | < ±1 s over 6-min sampling |
| Repeatability | ≤ ±10% FS |
| Size Distribution Error | ≤ ±30% |
| Indication Error | ≤ ±30% FS |
| Particle Size Channels | 0.3, 0.5, 1.0, 3.0, 5.0 µm |
| Sampling Duration | 10 sec – 99 min 59 sec |
| Data Storage Capacity | 7,000 records |
| Power Supply | 4 × AA Ni-MH batteries or AC adapter (100–240 V AC) |
| Dimensions | 108(W) × 68(D) × 196(H) mm |
| Weight | ~680 g (without batteries) |
| Compliance | GB/T 16292–2010, ISO 14644-1, China GMP (2010) Annex 1 |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3887L |
| Instrument Type | Handheld |
| Flow Rate | 2.83 L/min (0.1 cfm) |
| Flow Accuracy | <1 particle/5 min |
| Timing Accuracy | ±1 s within 6-min sampling |
| Repeatability | ≤±10% FS |
| Size Distribution Error | ≤±30% |
| Indication Error | ≤±30% FS |
| Particle Size Channels | 0.5 μm, 5.0 μm |
| Data Storage Capacity | 10,000 samples |
| Operating Temperature | 10–35 °C |
| Relative Humidity | ≤80% RH (non-condensing) |
| Power Supply | 4 × AA alkaline/Ni-MH batteries or AC adapter (100–240 V AC) |
| Dimensions | 108(W) × 68(D) × 196(H) mm |
| Weight | ~680 g (without batteries) |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3887L |
| Instrument Type | Handheld |
| Flow Rate | 2.83 L/min |
| Flow Accuracy | < ±1 particle per 5 min |
| Timing Accuracy | < ±1 s over 6-min sampling |
| Repeatability | ≤ ±10% FS |
| Size Distribution Error | ≤ ±30% |
| Indication Error | ≤ ±30% FS |
| Detectable Particle Sizes | 0.3, 0.5, 1.0, 3.0, 5.0 µm (user-selectable single or dual channels) |
| Compliance | GB/T 16292–2010, ISO 14644-1:2015, China GMP (2010) Annex 1 |
| Data Storage | Internal high-capacity non-volatile memory with statistical reporting |
| Power Management | Auto-save on power interruption, programmable delay start |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 3887Lite / 3887Pro |
| Instrument Type | Handheld Particle Counter |
| Flow Rate | 2.83 L/min ±5% |
| Detectable Particle Sizes | 0.3, 0.5, 1.0, 3.0, 5.0 µm (3887Pro) |
| Display | 3.5-inch resistive touchscreen |
| Light Source | Laser diode |
| Counting Efficiency | Compliant with ISO 21501-4 and JIS B9921 |
| Maximum Detectable Concentration | 2,000,000 particles/ft³ |
| Coincidence Loss | <5% at 2,000,000 particles/ft³ |
| Count Range | 1–70,000,000 counts |
| Sampling Modes | Single, Repeat, Continuous, Calculate, Remote, GB/T 16292, ISO 14644-1 |
| Sampling Time | 6 sec – 99 min 59 sec |
| Interval Time | 6 sec – 99 min 59 sec |
| Sample Count | 1–999 or continuous |
| Data Storage Capacity | 7,000 sample records |
| Communication Interfaces | USB Type-C, RS485 |
| Power Supply | Internal rechargeable Li-ion battery (≈5 h operation), AC adapter included |
| Operating Environment | 10–40 °C, 0–85% RH (non-condensing) |
| Dimensions | 87 × 200 × 55 mm |
| Weight | ≈600 g |
| Standard Accessories | Zero-count filter, sampling port cap, user manual, AC adapter with cable, calibration report, RS485 terminal block, protective carrying case |