| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 6720 |
| Air Flow Range | 40–4300 m³/h |
| Accuracy | ±3% of reading ±8 m³/h |
| Air Velocity Range (with Pitot tube) | 0.15–40 m/s |
| Air Velocity Range (with matrix sensor) | 0.15–15 m/s |
| Velocity Accuracy | ±3% of reading ±0.05 m/s |
| Differential Pressure Range | −2500 to +2500 Pa |
| DP Accuracy | ±1.5% of reading ±0.25 Pa |
| Temperature Range | 0–60 °C |
| Temp Accuracy | ±0.5 °C |
| Humidity Range | 0–100 %RH |
| RH Accuracy | ±3 %RH (10–90 %RH) |
| Operating Environment | 0–60 °C, 0–100 %RH |
| Display | 4.3-inch full-color touchscreen LCD |
| Data Storage | 8,000 measurements (instrument), 10,000 (mobile app) |
| Power | 4 × AA batteries (≈9 h), DC 5 V adapter |
| Weight | 3.6 kg |
| Standard Hood Size | 610 × 610 mm |
| Optional Hood Sizes | 610 × 1220 mm, 305 × 1220 mm, 500 × 500 mm, 915 × 915 mm, 915 × 610 mm, 800 × 1400 mm |
| Key Functions | Backpressure compensation, inlet/exhaust mode detection, atmospheric pressure & temperature correction, real-time Bluetooth data transmission, USB export, on-device clock & battery indicator |
| Brand | KANOMAX |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | 6720-DP |
| Measurement Range | ±2500 Pa |
| Accuracy Class | 0.01 |
| Medium | Gas |
| Operating Temperature | 0–60 °C (non-condensing) |
| Differential Pressure Resolution | 0.001 Pa |
| Differential Pressure Accuracy | ±1.5% of reading ±0.25 Pa |
| Air Velocity Range (with Pitot Tube) | 0.15–40 m/s |
| Air Velocity Range (with Air Velocity Matrix) | 0.15–15 m/s |
| Air Velocity Accuracy | ±3% of reading ±0.05 m/s (>0.25 m/s) |
| Air Velocity Resolution | 0.01 m/s |
| Display | 4.3-inch full-color touchscreen |
| Data Storage | 8,000 readings (instrument), 10,000 readings (mobile app) |
| Power | 4 × AA batteries (~14 h continuous operation), DC 5 V input |
| Weight | ~390 g |
| Communication | Bluetooth 4.2, USB data export |
| Brand | KANOMAX |
|---|---|
| Origin | China (Liaoning) |
| Model | 6720-DP |
| Pressure Range | –2500 to +2500 Pa |
| Accuracy (Pressure) | ±1.5% of reading ±0.25 Pa |
| Resolution (Pressure) | 0.001 Pa |
| Air Velocity Range (with Pitot Tube) | 0.15–40 m/s |
| Air Velocity Range (with Air Velocity Matrix) | 0.15–15 m/s |
| Accuracy (Velocity) | ±3% of reading ±0.05 m/s (>0.25 m/s) |
| Resolution (Velocity) | 0.01 m/s |
| Display | 4.3-inch full-color capacitive touchscreen |
| Data Storage | 8,000 readings (instrument), 10,000 (mobile app) |
| Battery Life | ~14 h (4 × AA alkaline) |
| Operating Temperature | 0–60 °C (non-condensing) |
| Weight | ~390 g |
| Communication | Bluetooth 4.2, USB data export |
| Compliance | Designed for ISO 14644, ISO 14645, NSF/ANSI 49, and EN 1822 test workflows |
| Brand | KANOMAX |
|---|---|
| Origin | Liaoning, China |
| Model | 6720-DP |
| Pressure Range | –2500 to +2500 Pa |
| Accuracy | ±1.5% of reading ±0.25 Pa |
| Resolution | 0.001 Pa |
| Air Velocity Range (with Pitot Tube) | 0.15–40 m/s |
| Air Velocity Accuracy | ±3% of reading ±0.05 m/s (for v > 0.25 m/s) |
| Velocity Resolution | 0.01 m/s |
| Display | 4.3-inch full-color touchscreen |
| Data Storage | 8,000 readings (instrument), 10,000 (mobile app) |
| Power | 4 × AA batteries (≈14 h operation) |
| Operating Temperature | 0–60 °C (non-condensing) |
| Weight | ≈390 g |
| Communication | Bluetooth 5.0, USB data export |
| Compliance | Designed for ISO 14644, ISO 14645, NSF/ANSI 49, and EU GMP Annex 1 environmental monitoring workflows |
| Brand | KANOMAX |
|---|---|
| Origin | Liaoning, China |
| Model | 6720-DP |
| Pressure Range | −2500 to +2500 Pa |
| Accuracy | ±1.5% of reading ±0.25 Pa |
| Resolution | 0.001 Pa |
| Velocity Range (with Pitot Tube) | 0.15–40 m/s |
| Velocity Accuracy | ±3% of reading ±0.05 m/s (for v > 0.25 m/s) |
| Velocity Resolution | 0.01 m/s |
| Display | 4.3-inch full-color touchscreen |
| Data Storage | 8,000 records (instrument), 10,000 records (mobile app) |
| Power | 4 × AA batteries (≈14 h continuous operation) |
| Operating Temperature | 0–60 °C (non-condensing) |
| Weight | ≈390 g |
| Communication | Bluetooth 4.2, USB data export |
| Compliance | Designed for ISO 14644, ISO 14645, NSF/ANSI 49, and EU GMP Annex 1 environmental qualification workflows |
| Brand | KANOMAX |
|---|---|
| Model | 6720-DP |
| Measurement Range | ±2500 Pa |
| Accuracy Class | 0.01 |
| Medium | Gas |
| Operating Temperature | 0–60 °C (non-condensing) |
| Display | 4.3-inch full-color touchscreen |
| Resolution | 0.001 Pa (differential pressure), 0.01 m/s (velocity) |
| Battery Life | ~14 h (4 × AA batteries) |
| Data Storage | 8,000 records (instrument), 10,000 records (mobile app) |
| Wind Velocity Range | 0.15–40 m/s (with Pitot tube), 0.15–15 m/s (with velocity matrix) |
| Velocity Accuracy | ±3% of reading ±0.05 m/s (>0.25 m/s) |
| DP Accuracy | ±1.5% of reading ±0.25 Pa |
| Weight | ~390 g |
| Brand | KANOMAX |
|---|---|
| Model | 6720-DP |
| Pressure Range | ±2500 Pa |
| Accuracy | ±1.5% of reading ±0.25 Pa |
| Resolution | 0.001 Pa |
| Velocity Range (with Pitot Tube) | 0.15–40 m/s |
| Velocity Accuracy | ±3% of reading ±0.05 m/s (for v > 0.25 m/s) |
| Velocity Resolution | 0.01 m/s |
| Display | 4.3-inch full-color touchscreen |
| Data Storage | 8,000 readings (instrument), 10,000 readings (mobile app) |
| Operating Temperature | 0–60 °C (non-condensing) |
| Power | 4 × AA batteries (≈14 h continuous use) |
| Communication | Bluetooth 4.2, USB data export |
| Weight | ≈390 g |
| Brand | KANOMAX |
|---|---|
| Origin | Liaoning, China |
| Model | 6720-DP |
| Pressure Range | −2500 to +2500 Pa |
| Accuracy | ±1.5% of reading ±0.25 Pa |
| Resolution | 0.001 Pa |
| Velocity Range (with Pitot Tube) | 0.15–40 m/s |
| Velocity Accuracy | ±3% of reading ±0.05 m/s (for v > 0.25 m/s) |
| Velocity Resolution | 0.01 m/s |
| Display | 4.3-inch full-color touchscreen |
| Data Storage | 8,000 records (device), 10,000 records (mobile app) |
| Operating Temperature | 0–60 °C (non-condensing) |
| Power | 4 × AA batteries (≈14 h continuous use) |
| Communication | Bluetooth 5.0, USB data export |
| Weight | ≈390 g |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 6750 |
| Resolution | 1 m³/h |
| Measurement Range | ±8–600 m³/h |
| Accuracy | ±(3% of reading + 1 m³/h) for 8–350 m³/h |
| Operating Temperature | 0–50 °C |
| Operating Humidity | 0–100 %RH |
| Display | Full-color TFT LCD with transparent viewing window |
| Connectivity | Bluetooth 4.2 (BLE) for wireless data transmission |
| Power Supply | Rechargeable Li-ion battery (up to 8 hours continuous operation) |
| Compliance | CE, RoHS, JIS B 8619 (Air Volume Measurement Instruments for HVAC Systems) |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 6750 |
| Air Flow Range | ±8–600 m³/h |
| Accuracy | ±(3% of reading + 1 m³/h) for 8–350 m³/h |
| Temperature Range | 0–50 °C |
| Temperature Accuracy | ±0.5 °C |
| Display | 160×80 mm color LCD |
| Data Storage | Up to 6,000 records (internal memory) |
| Communication | Bluetooth v4.0, USB output |
| Power | 4 × AA alkaline batteries or AC adapter |
| Operating Time | ~8 hours |
| Dimensions (hood) | 355×355×450 mm (W×H×D) |
| Hood Aperture | 355×355 mm |
| Weight | 1.5 kg |
| Compliance | Designed for ISO 14644-3, ISO 14644-4, IEST-RP-CC006.3, and ASHRAE 111-2020 test protocols |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 6750 |
| Resolution | 1 m³/h |
| Measurement Range | ±8–600 m³/h |
| Accuracy | ±(3% of reading + 1 m³/h) for 8–350 m³/h |
| Operating Temperature | 0–50 °C |
| Operating Humidity | 0–100 %RH |
| Temperature Accuracy | ±0.5 °C |
| Display | Simultaneous real-time airflow and temperature readout |
| Units | m³/h, CFM, °C |
| Data Storage | Up to 6,000 records (internal memory) |
| Communication | Bluetooth 4.0, USB output |
| Power | 4 × AA batteries or AC adapter |
| Battery Life | Approx. 8 hours continuous operation |
| Dimensions (hood) | 355 × 355 × 450 mm (W×H×D) |
| Hood Aperture | 355 × 355 mm |
| Display Module | 160 × 80 × 45 mm |
| Weight | 1.5 kg |
| Construction | Fiberglass support frame, transparent viewing window for visual alignment verification |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 6821 / 6823 |
| Instrument Type | Vane Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0.2–40.0 m/s |
| Accuracy | ±3% of reading or ±0.1 m/s (whichever is greater) |
| Temperature Range | –20 to +100 °C |
| Temperature Accuracy | ±0.3 °C + 0.2% of reading |
| Air Volume Range | 0–9,999 CFM |
| Probe Diameter | 70 mm |
| Power Supply | 3 × AA batteries |
| Dimensions | 81 × 165 × 38 mm |
| Weight | 1750 g (including batteries) |
| Brand | Kanomax |
|---|---|
| Model | 6822 |
| Type | Vane (Propeller) Anemometer |
| Measurement Range | 0.2–20.0 m/s |
| Resolution | 0.01 m/s |
| Accuracy | ±3% of reading or ±0.1 m/s (whichever is greater) |
| Operating Temperature | −20 to +100 °C |
| Operating Humidity | 5.0–95.0 %RH |
| Probe Diameter | 70 mm |
| Power Supply | 3 × AA batteries |
| Battery Life | Approx. 150 hours |
| Dimensions (W×H×D) | 81 × 165 × 38 mm |
| Weight | 175 g (including batteries) |
| Air Volume Calculation | Yes (user-input duct geometry) |
| Display | Backlit LCD |
| Data Hold & Min/Max/Avg Functions | Yes |
| Brand | Kanomax |
|---|---|
| Type | Vane Anemometer |
| Measurement Range | 0.2–20.0 m/s |
| Resolution | 0.01 m/s |
| Accuracy | ±3% of reading or ±0.1 m/s (whichever is greater) |
| Temperature Range | −20 to +100 °C |
| Temperature Accuracy | ±1.0 °C |
| Humidity Range (Model 6824 only) | 5.0–95.0 %RH |
| Humidity Accuracy (Model 6824 only) | ±2.0 %RH |
| Air Volume Calculation | 0–9,999 CFM |
| Probe Diameter | 70 mm |
| Power Supply | 3 × AA batteries |
| Battery Life | Approx. 150 hours |
| Dimensions (W×H×D) | 81 × 165 × 38 mm |
| Weight | 175 g (including batteries) |
| Operating Environment | −20 to +100 °C, 5–95 %RH (non-condensing) |
| Brand | Kanomax |
|---|---|
| Model | 6822 / 6824 |
| Type | Vane Anemometer |
| Resolution | 0.01 m/s |
| Velocity Range | 0.2–20.0 m/s |
| Accuracy | ±3% of reading or ±0.1 m/s (whichever is greater) |
| Temperature Range | –20 to +100 °C |
| Temperature Accuracy | ±1.0 °C |
| Humidity Range (6824 only) | 5.0–95.0 %RH |
| Humidity Accuracy (6824 only) | ±2.0 %RH |
| Air Volume Range | 0–9,999 CFM |
| Probe Diameter | 70 mm |
| Power | 3 × AA alkaline batteries |
| Battery Life | ~150 hours |
| Dimensions | 81(W) × 165(H) × 38(D) mm |
| Weight | 175 g (including batteries) |
| Compliance | Designed for ISO 14644-3, ISO 14644-1 cleanroom classification, ASTM D1896, and HVAC commissioning per ASHRAE Guideline 1 |
| Brand | Kanomax |
|---|---|
| Origin | Liaoning, China |
| Model | 6822 / 6824 |
| Instrument Type | Vane Anemometer |
| Velocity Range | 0.2–20.0 m/s |
| Accuracy | ±3% of reading or ±0.1 m/s (whichever is greater) |
| Temperature Range | −20–100 °C |
| Temperature Accuracy | ±1.0 °C |
| Airflow Range | 0–9,999 CFM |
| Probe Diameter | 70 mm |
| Power Source | Alkaline batteries |
| Battery Life | ~150 hours |
| Dimensions (W×H×D) | 81 × 165 × 38 mm |
| Weight | 175 g (including batteries) |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 6824 |
| Instrument Type | Vane Anemometer |
| Velocity Range | 0.2–20.0 m/s |
| Accuracy | ±3% of reading or ±0.1 m/s (whichever is greater) |
| Temperature Range | −20 to +100 °C |
| Temperature Accuracy | ±1.0 °C |
| Air Volume Range | 0–9,999 CFM |
| Probe Diameter | 70 mm |
| Power Source | Alkaline batteries |
| Battery Life | Approx. 150 hours |
| Dimensions (W×H×D) | 81 × 165 × 38 mm |
| Weight | 175 g (including batteries) |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 6850 |
| Differential Pressure Range | –2500 to +2500 Pa |
| Accuracy | ±0.5% of reading ±1 Pa |
| Resolution | 0.1 Pa |
| Air Velocity Range | 0.20–60.0 m/s |
| Velocity Accuracy | ±1.5% of reading (at 10.0 m/s) |
| Velocity Resolution | 0.01 m/s |
| Airflow Volume Range | 0–999999 m³/h |
| Volume Resolution | 1 m³/h |
| Operating Temperature | 0–60 °C (non-condensing) |
| Storage Temperature | –20–70 °C (non-condensing) |
| Power Supply | 4 × AA batteries or DC 5 V AC adapter |
| Battery Life | >15 hours |
| Weight (incl. batteries) | ~360 g |
| Data Storage Capacity | 10,000 records |
| Data Export | USB flash drive (FAT32 format) |
| Display | Full-color TFT LCD |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 6850 |
| Differential Pressure Range | –2500 to +2500 Pa |
| Accuracy | ±0.5% of reading ±1 Pa |
| Resolution | 0.1 Pa |
| Air Velocity Range | 0.20–60.0 m/s |
| Velocity Accuracy | ±1.5% of reading (at 10.0 m/s) |
| Velocity Resolution | 0.01 m/s |
| Airflow Volume Range | 0–999999 m³/h |
| Volume Resolution | 1 m³/h |
| Operating Temperature | 0–60 °C (non-condensing) |
| Storage Temperature | –20–70 °C (non-condensing) |
| Power Supply | 4 × AA batteries or DC 5 V AC adapter |
| Battery Life | >15 hours |
| Weight (incl. batteries) | ~360 g |
| Data Storage Capacity | 10,000 records |
| Data Export | USB flash drive support |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 6850 |
| Differential Pressure Range | −2500 to +2500 Pa |
| Accuracy | ±0.5% of reading ±1 Pa |
| Resolution | 0.1 Pa |
| Air Velocity Range | 0.20–60.0 m/s |
| Velocity Accuracy | ±1.5% of reading (at 10.0 m/s) |
| Velocity Resolution | 0.01 m/s |
| Airflow Range | 0–999999 m³/h |
| Flow Resolution | 1 m³/h |
| Operating Temperature | 0–60 °C (non-condensing) |
| Storage Temperature | −20–70 °C (non-condensing) |
| Power | 4 × AA batteries or DC 5 V AC adapter |
| Battery Life | >15 hours |
| Weight (with batteries) | ~360 g |
| Brand | KANOMAX |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | 6850 |
| Measurement Range | −2500 to +2500 Pa |
| Accuracy | ±0.5% of reading ±1 Pa |
| Resolution | 0.1 Pa |
| Wind Speed Range | 0.20–60.0 m/s |
| Wind Speed Accuracy | ±1.5% of reading (at 10.0 m/s) |
| Wind Speed Resolution | 0.01 m/s |
| Airflow Volume Range | 0–999,999 m³/h |
| Airflow Resolution | 1 m³/h |
| Operating Temperature | 0–60 °C (non-condensing) |
| Storage Temperature | −20–70 °C (non-condensing) |
| Power Supply | 4 × AA batteries or DC 5 V AC adapter |
| Battery Life | >15 hours |
| Weight (with batteries) | ~360 g |
| Display | Full-color LCD |
| Data Storage Capacity | 10,000 records |
| Data Export | USB flash drive (FAT32 formatted) |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 6850 |
| Differential Pressure Range | −2500 to +2500 Pa |
| Accuracy | ±0.5% of reading ±1 Pa |
| Resolution | 0.1 Pa |
| Air Velocity Range | 0.20–60.0 m/s |
| Velocity Accuracy | ±1.5% of reading (at 10.0 m/s) |
| Velocity Resolution | 0.01 m/s |
| Airflow Volume Range | 0–999,999 m³/h |
| Volume Resolution | 1 m³/h |
| Operating Temperature | 0–60 °C (non-condensing) |
| Storage Temperature | −20–70 °C (non-condensing) |
| Power Supply | 4 × AA batteries or DC 5 V AC adapter |
| Battery Life | >15 hours |
| Weight (with batteries) | ≈360 g |
| Data Storage Capacity | 10,000 records |
| Data Export | USB flash drive |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | MODEL S0104-4 |
| Steam Output | 65–390 g/h |
| Water Reservoir Capacity | 3.785 L |
| Thermal Loss | ≤75 W at −3 °C ±1 °C |
| Heater Power | Up to 500 W, AC 100 V |
| Nozzle ID | Φ15 mm, Length: 100 mm |
| Exhaust Fan Flow Rate | 0.05–0.1 m³/min at 49 Pa |
| Compliance | SAE J953 (JUN84), EEC/317, GB 11555–2009 |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0.01–50.0 m/s |
| Accuracy | ±2% of reading or ±0.02 m/s (whichever is greater) |
| Operating Temperature | 5–40 °C |
| Operating Humidity | 0–85% RH (non-condensing) |
| Display | 7-inch color LCD touchscreen |
| Max Channels | 144 (12 modules × 12 probes/module) |
| Power Supply | AC 100–240 V / DC 12–24 V |
| Data Storage | 8 GB internal memory (24,500 measurements per module) |
| Communication | USB / LAN |
| Output Options | 0–5 V / 4–20 mA (via Model 1592-0C module) |
| Compliance | CE-marked |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | Dependent on Interchangeable Probe Model |
| Accuracy | ±2% of Reading |
| Operating Temperature | −20 to +70 °C |
| Operating Humidity | 2.0–98.0% RH |
| Data Storage Capacity | Up to 20,000 Records |
| Probe Compatibility | 8 Standard KANOMAX Thermal Probes (e.g., KA3200, KA3300, KA3400 Series) |
| Built-in Calculations | Volumetric Air Flow (m³/h, CFM), Average/Min/Max Statistics, Hold Function |
| Input Parameters | Custom Duct Geometry (Rectangular, Circular, Oval) with Dimension Entry |
| Brand | KANOMAX |
|---|---|
| Origin | Liaoning, China |
| Model | 1580-0C |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0.01–50.0 m/s |
| Accuracy | ±2% of reading or ±0.02 m/s (whichever is greater) |
| Operating Temperature | 5–40 °C |
| Operating Humidity | 0–85% RH (non-condensing) |
| Weight | 0.6 kg |
| Dimensions | 220 × 130 × 40 mm (W × D × H) |
| Power Supply | AC 100–240 V / DC 12–24 V |
| Communication | USB Micro-B, RS-485 serial interface |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | 1590-0C |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | Probe-Dependent (0.01–50.0 m/s) |
| Accuracy | ±2% or ±0.02 m/s (whichever greater), ±3% for select probes |
| Operating Temperature | 0–60 °C |
| Operating Humidity | 0–90 %RH (non-condensing) |
| Display | 7-inch color TFT touchscreen |
| Data Storage | 8 GB internal memory (24,500 measurements per module) |
| Communication | USB 2.0, LAN (RJ45), serial interface |
| Power Supply | AC 100–240 V / DC 12–24 V |
| Dimensions (H×W×D) | 40 × 220 × 130 mm |
| Weight | 0.6 kg |
| Compliance | CE, RoHS, ISO/IEC 17025-compatible operation |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Instrument Type | Thermal Anemometer-Based Environmental Monitoring System |
| Resolution | 0.01 m/s |
| Measurement Range | Configurable per probe (0.01–50.0 m/s) |
| Accuracy | ±2% or ±0.02 m/s (whichever greater), ±0.5 °C for temperature, ±3–5% RH (5–90% RH) |
| Operating Temperature | 5–40 °C |
| Operating Humidity | 0–85% RH (non-condensing) |
| Display | 7-inch color LCD touchscreen |
| Data Storage | 8 GB internal memory (24,500 measurements per channel) |
| Communication | USB 2.0, LAN (TCP/IP), RS-485 serial |
| Power Supply | AC 100–240 V or DC 12–24 V |
| Dimensions (Unit) | 220 × 130 × 40 mm |
| Weight | 0.6 kg |
| Max Channel Capacity | 144 simultaneous channels (via 12 × MODEL 1591-0C modules, 12 probes each) |
| Probe Compatibility | 15 interchangeable thermal anemometer probes (directional/non-directional, standard/high-temp, mini-size options) |
| Analog Output | MODEL 1592-0C module supports 12-channel 4–20 mA or 0–5 V output per module (scalable to 144 channels) |
| Software | Windows 10-compatible, multilingual (EN/JP/CN), real-time charting, CSV export, configurable per-probe calibration and averaging |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 1590-0C |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0.01–50.0 m/s |
| Accuracy | ±2% of reading or ±0.02 m/s (whichever is greater) |
| Operating Temperature | 5–40 °C |
| Operating Humidity | 0–85% RH (non-condensing) |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | PRO 1590-0C |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0.01–50.0 m/s |
| Accuracy | ±2% of reading or ±0.02 m/s (whichever is greater) |
| Operating Temperature | 5–40 °C |
| Operating Humidity | 0–85% RH (non-condensing) |
| Display | 7-inch color LCD touchscreen |
| Data Storage | 8 GB internal memory (24,500 measurements per unit) |
| Communication | USB 2.0, LAN (RJ45), serial interface |
| Power Supply | AC 100–240 V or DC 12–24 V |
| Dimensions (main unit) | 220 × 130 × 40 mm |
| Weight | 0.6 kg |