| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3887Lite / 3887Pro |
| Instrument Type | Handheld |
| Flow Rate | 2.83 L/min ±5% |
| Particle Size Channels | 0.3, 0.5, 1.0, 3.0, 5.0 µm (3887Pro) |
| Display | 3.5-inch resistive touchscreen |
| Light Source | Laser diode |
| Counting Efficiency | Compliant with ISO 21501-4 and JIS B9921 |
| Max. Detectable Concentration | 2,000,000 particles/ft³ |
| Coincidence Loss | <5% at 2,000,000 particles/ft³ |
| Count Range | 1–70,000,000 |
| Sampling Modes | Single, Repeat, Continuous, Calculate, Remote, GB/T, ISO |
| Sampling Time | 6 sec – 99 min 59 sec |
| Interval Time | 6 sec – 99 min 59 sec |
| Sample Count | 1–999 or continuous |
| Data Storage Capacity | 7,000 measurement sets |
| Power | Rechargeable Li-ion battery (≈5 h operation) + USB-C AC adapter |
| Dimensions | 87 × 200 × 55 mm |
| Weight | ≈600 g |
| Operating Environment | 10–40 °C, 0–85% RH (non-condensing) |
| Communication | USB and RS-485 interfaces |
| Compliance | GB/T 16292–2010, ISO 14644-1, China GMP (2010), FDA-relevant cleanroom monitoring practices |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3887Lite / 3887Pro |
| Flow Rate | 2.83 L/min ±5% |
| Particle Size Channels | 0.3, 0.5, 1.0, 3.0, 5.0 µm (3887Pro) |
| Display | 3.5-inch resistive touchscreen |
| Light Source | Laser diode |
| Counting Efficiency | Compliant with ISO 21501-4 and JIS B9921 |
| Max Concentration | 2,000,000 particles/ft³ |
| Coincidence Loss | <5% at 2,000,000 particles/ft³ |
| Count Range | 1–70,000,000 |
| Sampling Modes | Single, Repeat, Continuous, Calculate, Remote, GB/T, ISO |
| Sampling Time | 6 sec–99 min 59 sec |
| Interval Time | 6 sec–99 min 59 sec |
| Sample Count | 1–999 or continuous |
| Data Storage | 7,000 records |
| Power | Rechargeable Li-ion battery (≈5 h operation) + USB-C AC adapter |
| Dimensions | 87 × 200 × 55 mm |
| Weight | ≈600 g |
| Operating Environment | 10–40 °C, 0–85% RH (non-condensing) |
| Compliance | GB/T 16292–2010, ISO 14644-1, China GMP (2010), ISO 21501-4, JIS B9921 |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3887Lite / 3887Pro |
| Instrument Type | Handheld |
| Flow Rate | 2.83 L/min ±5% |
| Detectable Particle Sizes | 0.3, 0.5, 1.0, 3.0, 5.0 µm (3887Pro) |
| Display | 3.5-inch resistive touchscreen |
| Light Source | Laser diode |
| Counting Efficiency Compliance | ISO 21501-4 & JIS B9921 |
| Max. Concentration | 2,000,000 particles/ft³ |
| Coincidence Loss | <5% at 2,000,000 particles/ft³ |
| Count Range | 1–70,000,000 |
| Sampling Modes | Single, Repeat, Continuous, Calculate, Remote, GB, ISO |
| Sampling Time | 6 sec–99 min 59 sec |
| Interval Time | 6 sec–99 min 59 sec |
| Sample Count | 1–999 or continuous |
| Data Storage Capacity | 7,000 records |
| Power | Rechargeable Li-ion battery (≈5 h operation) + USB-C AC adapter |
| Dimensions | 87 × 200 × 55 mm |
| Weight | ≈600 g |
| Operating Environment | 10–40 °C, 0–85% RH (non-condensing) |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3887Lite / 3887Pro |
| Instrument Type | Handheld Particle Counter |
| Flow Rate | 2.83 L/min ±5% |
| Detectable Particle Sizes | 0.3, 0.5, 1.0, 3.0, 5.0 µm (3887Pro) |
| Display | 3.5-inch resistive touchscreen |
| Light Source | Laser diode |
| Counting Efficiency Compliance | ISO 21501-4 & JIS B9921 |
| Maximum Detectable Concentration | 2,000,000 particles/ft³ |
| Coincidence Loss | <5% at 2,000,000 particles/ft³ |
| Count Range | 1–70,000,000 |
| Sampling Modes | Single, Repeat, Continuous, Calculate, Remote, GB/T 16292, ISO 14644-1 |
| Sampling Time | 6 sec – 99 min 59 sec |
| Interval Time | 6 sec – 99 min 59 sec |
| Sample Count | 1–999 or continuous |
| Data Storage Capacity | 7,000 records |
| Power Supply | Rechargeable Li-ion battery (≈5 h operation) + USB-C AC adapter |
| Dimensions | 87 × 200 × 55 mm |
| Weight | ≈600 g |
| Operating Environment | 10–40 °C, 0–85% RH (non-condensing) |
| Communication Interfaces | USB & RS-485 |
| Standard Accessories | Zero-count filter, sampling port cap, user manual, AC adapter with cable, calibration report, RS-485 terminal block, protective carrying case |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3887Lite / 3887Pro |
| Instrument Type | Handheld Particle Counter |
| Flow Rate | 2.83 L/min ±5% |
| Detectable Particle Sizes | 0.3, 0.5, 1.0, 3.0, 5.0 µm (3887Pro) |
| Light Source | Laser Diode |
| Compliance | ISO 21501-4, JIS B9921 |
| Maximum Detectable Concentration | 2,000,000 particles/ft³ |
| Counting Efficiency | ≥50% at 0.3 µm, ≥100% at ≥0.5 µm |
| Display | 3.5-inch Resistive Touchscreen |
| Data Storage | 7,000 sample records |
| Power | Rechargeable Li-ion battery (≈5 h operation), USB-C AC adapter |
| Operating Environment | 10–40 °C, 0–85% RH (non-condensing) |
| Dimensions | 87 × 200 × 55 mm |
| Weight | ≈600 g |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Instrument Type | Handheld |
| Flow Rate | 2.83 L/min ±5% |
| Detectable Particle Sizes | 0.3, 0.5, 5.0 µm |
| Display | 3.5-inch resistive touchscreen |
| Light Source | Laser diode |
| Counting Efficiency | Compliant with ISO 21501-4 and JIS B9921 |
| Maximum Concentration | 2,000,000 particles/ft³ |
| Coincidence Loss | <5% at 2,000,000 particles/ft³ |
| Count Range | 1–70,000,000 |
| Test Modes | Single, Repeat, Continuous, Calculate, Remote, GB, ISO |
| Sampling Time | 6 sec–99 min 59 sec |
| Interval Time | 6 sec–99 min 59 sec |
| Sample Count | 1–999 or continuous |
| Data Storage Capacity | 7,000 records |
| Power Supply | Internal Li-ion battery (≈5 h operation) + USB-C AC adapter |
| Dimensions | 87 × 200 × 55 mm |
| Weight | ≈600 g |
| Operating Environment | 10–40 °C, 0–85% RH (non-condensing) |
| Standard Accessories | Zero-count filter, inlet cap, user manual, AC adapter with cable, calibration report, RS485 terminal block, protective carrying case |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3887Pro |
| Instrument Type | Handheld |
| Flow Rate | 2.83 L/min ±5% |
| Particle Size Channels | 0.3, 0.5, 1.0, 3.0, 5.0 µm |
| Display | 3.5-inch resistive touchscreen |
| Light Source | Laser diode |
| Counting Efficiency Compliance | ISO 21501-4 & JIS B9921 |
| Maximum Detectable Concentration | 2,000,000 particles/ft³ |
| Coincidence Loss | <5% at 2,000,000 particles/ft³ |
| Count Range | 1–70,000,000 |
| Sampling Modes | Single, Repeat, Continuous, Calculate, Remote, GB, ISO |
| Sampling Time | 6 sec–99 min 59 sec |
| Interval Time | 6 sec–99 min 59 sec |
| Sample Count | 1–999 or continuous |
| Data Storage Capacity | 7,000 sample records |
| Power Supply | Internal Li-ion battery (≈5 h operation) + USB-C AC adapter |
| Operating Environment | 10–40 °C, 0–85% RH (non-condensing) |
| Dimensions | 87 × 200 × 55 mm |
| Weight | ≈600 g |
| Communication Interfaces | USB & RS485 |
| Standards Compliance | GB/T 16292–2010, ISO 14644-1, China GMP (2010) Annex 1 |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3887Pro |
| Instrument Type | Handheld |
| Flow Rate | 2.83 L/min ±5% |
| Detectable Particle Sizes | 0.3, 0.5, 1.0, 3.0, 5.0 µm |
| Display | 3.5-inch resistive touchscreen |
| Light Source | Laser diode |
| Counting Efficiency Compliance | ISO 21501-4 & JIS B9921 |
| Maximum Detectable Concentration | 2,000,000 particles/ft³ |
| Coincidence Loss | <5% at 2,000,000 particles/ft³ |
| Count Range | 1–70,000,000 counts |
| Sampling Modes | Single, Repeat, Continuous, Calculate, Remote, GB, ISO |
| Sampling Time | 6 sec–99 min 59 sec |
| Interval Time | 6 sec–99 min 59 sec |
| Sample Count | 1–999 or continuous |
| Data Storage Capacity | 7,000 records |
| Power Supply | Rechargeable Li-ion battery (≈5 h operation) + USB-C AC adapter |
| Operating Environment | 10–40 °C, 0–85% RH (non-condensing) |
| Dimensions | 87 × 200 × 55 mm |
| Weight | ≈600 g |
| Communication Interfaces | USB & RS485 |
| Standard Accessories | Zero-count filter, inlet cap, user manual, AC adapter with cable, calibration report, RS485 terminal block, protective carrying case |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | Kanomax 3888 |
| Instrument Type | Handheld |
| Flow Rate | 2.83 L/min (0.1 cfm) |
| Flow Accuracy | < ±1 particle per 5 min |
| Timing Accuracy | ±1 s within 6-min sampling |
| Repeatability | ≤ ±10% FS |
| Size Distribution Error | ≤ ±30% |
| Indication Error | ≤ ±30% FS |
| Particle Channels | 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 µm |
| Max Detectable Concentration | 2,000,000 particles/ft³ |
| Data Storage | 10,000 samples (CSV format) |
| Power | Dual 3.7 V / 2600 mAh rechargeable Li-ion batteries |
| Battery Life | 5 hours (single-test mode) |
| Operating Environment | 10–40 °C, 0–85% RH (non-condensing) |
| Dimensions | 102 × 56 × 215 mm (W × D × H) |
| Weight | ~650 g |
| Compliance | ISO 21501-4, JIS B9921, GB/T 16292-2010, ISO 14644-1, China GMP (2010) |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | KANOMAX 3889 |
| Instrument Type | Handheld |
| Flow Rate | 2.83 L/min |
| Flow Accuracy | < ±1 particle/5 min |
| Timing Accuracy | < ±1 s over 6-min sampling |
| Repeatability | ≤ ±10% FS |
| Size Distribution Error | ≤ ±30% |
| Indication Error | ≤ ±30% FS |
| Particle Channels | 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 µm |
| Display | 4.3-inch full-color TFT touchscreen |
| Language Support | English, Chinese, Japanese, Spanish |
| Data Storage | Internal high-capacity memory with statistical analysis |
| Connectivity | USB and Wi-Fi |
| Compliance | ISO 21501-4, ISO 14644-1, GB/T 16292–2010, China GMP (2010) Annex 1 |
| Environmental Sensors | Optional external temperature & relative humidity probes |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3905 |
| Flow Rate | 28.3 L/min |
| Flow Accuracy | < ±1 particle per 5 min |
| Timing Accuracy | < ±1 s over 6-min sampling |
| Repeatability | ≤ ±10% FS |
| Size Distribution Error | ≤ ±30% |
| Indication Error | < ±30% FS |
| Particle Detection Efficiency | 50 ± 20% @ 0.3 µm (ISO 21501-4), 50 ± 20% @ 0.5 µm (ISO 21501-4) |
| Max. Concentration | 500,000 particles/ft³ |
| Size Resolution | < 15% @ 0.3 µm and @ 0.5 µm (ISO 21501-4) |
| Zero Count | Compliant with JIS B 9921 |
| Miscount Rate | < 0.2 particles/ft³ (ISO 21501-4) |
| Display | 6.4-inch full-color touchscreen |
| Data Storage | 10,000 sample records (internal) |
| Compliance | ISO 14644-1:2015, ISO 14644-2:2015, GB/T 16292–2010, GB 50333–2013, US Federal Standard 209E (repealed but referenced), BS 5295, EC GMP Annex 1, FDA 21 CFR Part 11 (audit trail & electronic signature support), JJF 1190–2008 |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3905 |
| Flow Rate | 28.3 L/min |
| Particle Size Channels | 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 µm |
| Counting Efficiency | ≥50% ±20% at 0.3 µm (ISO 21501-4 compliant) |
| Maximum Concentration | 500,000 particles/ft³ |
| Repeatability | ≤±10% FS |
| Size Distribution Error | ≤±30% |
| Indication Error | <±30% FS |
| Timing Accuracy | ±1 s within 6-min sampling |
| Flow Accuracy | <1 particle deviation per 5 min |
| Data Storage | 10,000 sample records (internal), USB-expandable |
| Display | 6.4-inch full-color touchscreen |
| Compliance | ISO 14644-1:2015, ISO 14644-2:2015, GB/T 16292–2010, JJF 1190–2008, FDA 21 CFR Part 11 (audit trail enabled), EC GMP Annex 1, JIS B 9921 |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | KANOMAX 3905 |
| Flow Rate | 28.3 L/min |
| Flow Accuracy | < ±1 particle per 5 min |
| Timing Accuracy | < ±1 s over 6-min sampling |
| Repeatability | ≤ ±10% FS |
| Size Distribution Error | ≤ ±30% |
| Indication Error | < ±30% FS |
| Particle Channels | 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 µm |
| Display | 6.4-inch true-color touchscreen |
| Data Storage | 10,000 sample records (expandable via USB flash drive) |
| Environmental Sensors | optional external probes for temperature, relative humidity, air velocity, and differential pressure (international version only) |
| Compliance | JJF 1190–2008, GB/T 16292–2010, ISO 14644-1 |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3905 |
| Flow Rate | 28.3 L/min |
| Particle Size Channels | 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 µm |
| Counting Efficiency | ≥50% ±20% at 0.3 µm (ISO 21501-4 compliant) |
| Repeatability | ≤±10% FS |
| Size Resolution | <15% at 0.3 µm and 0.5 µm (ISO 21501-4) |
| Max Concentration | 500,000 particles/ft³ |
| Sampling Time Range | 6 sec – 23 h 59 min 59 sec |
| Data Storage | 10,000 sample records (internal), USB-expandable |
| Display | 6.4-inch full-color touchscreen |
| Compliance | ISO 14644-1:2015, ISO 14644-2:2015, GB/T 16292–2010, JJF 1190–2008, EU GMP Annex 1, FDA 21 CFR Part 11 (audit trail & electronic signature support) |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3910 |
| Flow Rate | 50 L/min |
| Flow Accuracy | < ±1 particle per 5 min |
| Timing Accuracy | < ±1 s over 6-min sampling |
| Repeatability | ≤ ±10% FS |
| Size Distribution Error | ≤ ±30% |
| Indication Error | < ±30% FS |
| Particle Sizing Channels | 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 µm |
| Counting Efficiency | 50 ± 20% @ 0.3 µm (ISO 21501-4 compliant) |
| Max Concentration | 300,000 particles/ft³ |
| Size Resolution | <15% @ 0.3 µm and @ 0.5 µm (ISO 21501-4) |
| Zero Count | Compliant with JIS B 9921 |
| False Count | < 0.2 particles/ft³ (ISO 21501-4) |
| Data Storage | 10,000 sample records (internal), USB-expandable |
| Display | 6.4-inch true-color touchscreen |
| Operating Temperature/Humidity Sensors | Optional external probes (temperature, RH, differential pressure, air velocity) |
| Compliance | ISO 14644-1:2015, ISO 14644-2:2015, GB/T 16292–2010, JJF 1190–2008, EU GMP Annex 1 (2022), USP <788>, FDA 21 CFR Part 11 (audit trail & electronic signature support) |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | KANOMAX 3910 |
| Flow Rate | 50 L/min |
| Flow Accuracy | <1 particle/5 min |
| Timing Error | <±1 s over 6-min sampling |
| Repeatability | ≤±10% FS |
| Size Distribution Error | ≤±30% |
| Indication Error | <±30% FS |
| Particle Size Channels | 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 µm |
| Counting Efficiency | 50±20% @ 0.3 µm (ISO 21501-4 compliant) |
| Max Concentration | 500,000 particles/ft³ |
| Size Resolution | <15% @ 0.3 µm (ISO 21501-4) |
| Zero Count | Compliant with JIS B 9921 |
| Data Storage | 10,000 sample records |
| Display | 6.4-inch full-color touchscreen |
| Compliance | ISO 14644-1:2015, ISO 14644-2:2015, GB/T 16292–2010, JJF 1190–2008, EU GMP Annex 1, USP <788>, FDA 21 CFR Part 11 (audit trail & electronic signature support) |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3910 |
| Flow Rate | 50 L/min |
| Detectable Particle Sizes | 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 µm (user-selectable within 0.3–10.0 µm range) |
| Counting Efficiency | 50 ± 20% @ 0.3 µm (ISO 21501-4 compliant) |
| Maximum Concentration | 500,000 particles/ft³ |
| Size Resolution | <15% @ 0.3 µm (ISO 21501-4) |
| Data Storage | 10,000 measurement records (internal), USB-expandable |
| Display | 6.4-inch full-color touchscreen |
| Compliance | ISO 14644-1:2015, ISO 14644-2:2015, GB/T 16292–2010, JJF 1190–2008, USP <788>, FDA 21 CFR Part 11 (audit trail & electronic signature support), EU GMP Annex 1, JIS B 9921 |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3910+ |
| Flow Rate | 50 L/min |
| Flow Accuracy | < ±1 particle per 5 min |
| Timing Accuracy | < ±1 s over 6-min sampling |
| Repeatability | ≤ ±10% FS |
| Size Distribution Error | ≤ ±30% |
| Indication Error | < ±30% FS |
| Particle Size Channels | 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 µm |
| Counting Efficiency | 50 ± 20% @ 0.3 µm (ISO 21501-4 compliant) |
| Max Concentration | 300,000 particles/ft³ |
| Resolution | <15% @ 0.3 µm (ISO 21501-4) |
| Zero Count | Compliant with JIS B 9921 |
| Data Storage | 10,000 sample records (expandable via USB drive) |
| Display | 6.4-inch full-color touchscreen |
| Compliance | ISO 14644-1:2015, ISO 14644-2:2015, GB/T 16292–2010, JJF 1190–2008, EU GMP Annex 1, US FDA 21 CFR Part 11 (audit trail & electronic signature support) |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3920 |
| Flow Rate | 100 L/min |
| Flow Accuracy | < ±1 particle/5 min |
| Timing Accuracy | < ±30% FS |
| Repeatability | ≤ ±10% FS |
| Size Distribution Error | ≤ ±30% |
| Indication Error | < ±30% FS |
| Particle Sizing Channels | 0.5, 0.7, 1.0, 3.0, 5.0, 10.0 µm |
| Counting Efficiency | 50 ± 20% @ 0.5 µm (compliant with ISO 21501-4) |
| Max. Concentration | 300,000 particles/ft³ |
| Size Resolution | < 15% @ 0.5 µm (ISO 21501-4) |
| Zero Count | Compliant with JIS B 9921 |
| Data Storage | 10,000 measurement records |
| Compliance | ISO 14644-1:2015, ISO 14644-2:2015, EU GMP Annex 1, USP <788>, FDA 21 CFR Part 11, GB/T 16292–2010, GB 50333–2013, Federal Standard 209E, BS 5295 |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3920+ |
| Flow Rate | 100 L/min |
| Flow Accuracy | < ±1 particle/5 min |
| Timing Error | < ±30% FS |
| Repeatability | ≤ ±10% FS |
| Size Distribution Error | ≤ ±30% |
| Indication Error | < ±30% FS |
| Particle Sizing Channels | 0.5, 0.7, 1.0, 3.0, 5.0, 10.0 µm |
| Counting Efficiency | 50 ± 20% @ 0.5 µm (ISO 21501-4 compliant) |
| Max Concentration | 300,000 particles/ft³ |
| Size Resolution | < 15% @ 0.5 µm (ISO 21501-4) |
| Zero Count | Compliant with JIS B 9921 |
| Data Storage | 10,000 measurement records with geotagging (map code) |
| Compliance | ISO 14644-1:2015, ISO 14644-2:2015, EU GMP Annex 1 (2022), USP <788>, FDA 21 CFR Part 11 (audit trail, electronic signature, user access control), GB/T 16292–2010, GB 50333–2013 |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3950 |
| Flow Rate | 2.83 L/min (0.1 CFM) |
| Flow Accuracy | ±5% |
| Timing Accuracy | ±1 s per 6 min |
| Repeatability | ±5% |
| Size Distribution Error | ±15% |
| Indication Error | ±30% |
| Particle Detection Principle | Light Scattering |
| Channel Sizes | 0.1 µm, 0.3 µm |
| Max Concentration | 10⁷ particles/m³ |
| Counting Efficiency | 50±20% at 0.1 µm (PSL), 100±10% at 0.15–0.2 µm (PSL) |
| Size Resolution | ≤15% (relative to 0.3 µm PSL) |
| Display | 4.3″ color TFT touchscreen |
| Communication | RS-485, Ethernet, USB (Host/Device) |
| Data Storage | 10,000 records (CSV) |
| Operating Environment | 15–35 °C, 0–85% RH (non-condensing) |
| Dimensions | 150 × 163 × 228 mm |
| Weight | 3.4 kg |
| Compliance | JIS B9921, ISO 21501-4 |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3950 |
| Flow Rate | 2.83 L/min (0.1 CFM) |
| Flow Accuracy | ±5% |
| Timing Accuracy | ±1 s per 6 min |
| Repeatability | ±5% |
| Size Distribution Error | ±15% |
| Indication Error | ±30% |
| Particle Detection Channels | 0.1 µm, 0.3 µm |
| Counting Efficiency | 50±20% @ 0.1 µm (PSL), 100±10% @ 0.15–0.2 µm (PSL) |
| Maximum Concentration | 10⁷ particles/m³ |
| False Count Rate | <1 count/35 min |
| Size Resolution | ≤15% (relative to 0.3 µm PSL) |
| Display | 4.3″ color TFT touchscreen |
| Communication | USB (Host/Device), Ethernet, RS-485 (9600–38400 baud) |
| Data Storage | up to 10,000 records in CSV format |
| Operating Environment | 15–35 °C, 0–85% RH (non-condensing) |
| Dimensions | 150 × 163 × 228 mm |
| Weight | 3.4 kg |
| Compliance | JIS B9921, ISO 21501-4 |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3950 |
| Flow Rate | 2.83 L/min (0.1 CFM) |
| Flow Accuracy | ±5% |
| Timing Accuracy | ±1 s per 6 min |
| Repeatability | ±5% |
| Size Resolution | ≤15% (vs. 0.3 µm PSL) |
| Counting Efficiency | 50±20% at 0.1 µm, 100±10% at 0.15–0.2 µm PSL |
| Max Concentration | 10⁷ particles/m³ |
| Particle Channels | 0.1 µm & 0.3 µm |
| Compliance | JIS B9921 & ISO 21501-4 |
| Display | 4.3" color TFT touchscreen |
| Interface | USB Host/Device, Ethernet, RS-485 |
| Data Storage | 10,000 records (CSV) |
| Operating Environment | 15–35°C, 0–85% RH (non-condensing) |
| Dimensions | 150 × 163 × 228 mm |
| Weight | 3.4 kg |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3950 |
| Flow Rate | 2.83 L/min (0.1 CFM) |
| Flow Accuracy | ±5% |
| Timing Accuracy | ±1 s per 6 min |
| Repeatability | ±5% |
| Size Distribution Error | ±15% |
| Indication Error | ±30% |
| Particle Detection Channels | 0.1 µm, 0.3 µm |
| Maximum Concentration | 10⁷ particles/m³ |
| Counting Efficiency | 50±20% at 0.1 µm (PSL), 100±10% at 0.15–0.2 µm (PSL) |
| False Count Rate | <1 count/35 min |
| Size Resolution | ≤15% (relative to 0.3 µm PSL) |
| Display | 4.3″ color TFT touchscreen |
| Communication | USB (Host/Device), Ethernet, RS-485 (9600–38400 baud) |
| Data Storage | up to 10,000 records in CSV format |
| Operating Environment | 15–35 °C, 0–85% RH (non-condensing) |
| Dimensions | 150 × 163 × 228 mm |
| Weight | 3.4 kg |
| Compliance | JIS B9921, ISO 21501-4 |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 3950-00 |
| Flow Rate | 2.83 L/min (0.1 CFM) |
| Flow Accuracy | ±5% |
| Timing Accuracy | ±1 s per 6 min |
| Repeatability | ±5% |
| Size Resolution | ≤15% (relative to 0.3 μm PSL) |
| Counting Efficiency | 50±20% at 0.1 μm, 100±10% at 0.15–0.2 μm PSL |
| Max. Concentration | 10⁷ particles/m³ |
| False Count Rate | <1 count/35 min |
| Measurement Channels | 0.1 μm and 0.3 μm |
| Compliance | JIS B9921 & ISO 21501-4 |
| Display | 4.3″ color TFT touchscreen |
| Communication | USB (Host/Device), Ethernet, RS-485 (9600–38400 baud) |
| Data Storage | Internal memory (10,000 records, CSV format) |
| Operating Environment | 15–35 °C, 0–85% RH (non-condensing) |
| Dimensions | 150 × 163 × 228 mm |
| Weight | 3.4 kg |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3950-00 |
| Flow Rate | 2.83 L/min (0.1 CFM) |
| Flow Accuracy | ±5% |
| Timing Accuracy | ±1 s per 6 min |
| Repeatability | ±5% |
| Size Distribution Error | ±15% |
| Indication Error | ±30% |
| Particle Channels | 0.1 µm, 0.3 µm |
| Maximum Concentration | 10⁷ particles/m³ |
| Counting Efficiency | 50±20% at 0.1 µm (PSL), 100±10% at 0.15–0.2 µm (PSL) |
| False Count Rate | <1 count/35 min |
| Size Resolution | ≤15% (relative to 0.3 µm PSL) |
| Display | 4.3" color TFT touchscreen |
| Communication | RS-485, Ethernet (10/100BASE-TX), USB Host/Device |
| Data Storage | up to 10,000 records (CSV) |
| Operating Environment | 15–35 °C, 0–85% RH (non-condensing) |
| Dimensions | 150 × 163 × 228 mm |
| Weight | 3.4 kg |
| Compliance | JIS B9921, ISO 21501-4 |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 3950-00 |
| Flow Rate | 2.83 L/min (0.1 CFM) |
| Flow Accuracy | ±5% |
| Timing Accuracy | ±1 s per 6 min |
| Repeatability | ±5% |
| Size Distribution Error | ±15% |
| Indication Error | ±30% |
| Particle Detection Principle | Light Scattering |
| Calibration Standards | Compliant with JIS B9921 and ISO 21501-4 |
| Channel Configuration | Dual-channel (0.1 µm, 0.3 µm) |
| Maximum Concentration | 10⁷ particles/m³ |
| Counting Efficiency | 50±20% at 0.1 µm (PSL), 100±10% at 0.15–0.2 µm (PSL) |
| False Count Rate | <1 count per 35 min |
| Size Resolution | ≤15% (relative to 0.3 µm PSL) |
| Display | 4.3" color TFT touchscreen |
| Communication Interfaces | USB (Host/Device), Ethernet, RS-485 (9600–38400 baud) |
| Data Storage | Internal memory (up to 10,000 records, CSV format) |
| Operating Environment | 15–35 °C, 0–85% RH (non-condensing) |
| Dimensions | 150 × 163 × 228 mm |
| Weight | 3.4 kg |
| Brand | Kanomax |
|---|---|
| Model | 3950-00 |
| Detection Principle | Light Scattering |
| Particle Channels | 0.1 µm, 0.3 µm |
| Nominal Flow Rate | 2.83 L/min (0.1 CFM) |
| Accuracy | ±5% |
| Compliance | ISO 21501-4 & JIS B9921 |
| Display | 4.3" Color Touchscreen LCD |
| Communication | RS-458, Ethernet, USB (Host/Device) |
| Data Storage | Up to 10,000 records (CSV) |
| Operating Environment | 15–35 °C, 0–85% RH (non-condensing) |
| Dimensions | 150 × 163 × 228 mm |
| Weight | 3.4 kg |
| Max. Concentration | 10⁷ particles/m³ |
| Counting Efficiency | 50±20% at 0.1 µm (PSL), 100±10% at 0.15–0.2 µm (PSL) |
| False Count Rate | <1 count per 35 min |
| Size Resolution | ≤15% (at 0.3 µm PSL) |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 3950-00 |
| Flow Rate | 2.83 L/min (0.1 CFM) |
| Flow Accuracy | ±5% |
| Timing Accuracy | ±1 s per 6 min |
| Repeatability | ±5% |
| Size Distribution Error | ±15% |
| Indication Error | ±30% |
| Particle Channels | 0.1 μm & 0.3 μm |
| Detection Principle | Light Scattering |
| Compliance | JIS B9921 & ISO 21501-4 |
| Max Concentration | 10⁷ particles/m³ |
| Counting Efficiency | 50±20% @ 0.1 μm PSL, 100±10% @ 0.15–0.2 μm PSL |
| False Count Rate | <1 count/35 min |
| Size Resolution | ≤15% (vs. 0.3 μm PSL) |
| Display | 4.3″ Color TFT Touchscreen |
| Communication | RS-485, Ethernet (10/100BASE-T), USB Host/Device |
| Data Storage | Internal CSV (up to 10,000 records) |
| Operating Environment | 15–35 °C, 0–85% RH (non-condensing) |
| Dimensions | 150 × 163 × 228 mm |
| Weight | 3.4 kg |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 3950-00 |
| Flow Rate | 2.83 L/min (0.1 CFM) |
| Flow Accuracy | ±5% |
| Timing Accuracy | ±1 s per 6 min |
| Repeatability | ±5% |
| Size Distribution Error | ±15% |
| Indication Error | ±30% |
| Particle Detection Principle | Light Scattering |
| Channel Sizes | 0.1 µm and 0.3 µm |
| Max Concentration | 10⁷ particles/m³ |
| Counting Efficiency | 50±20% at 0.1 µm (PSL), 100±10% at 0.15–0.2 µm (PSL) |
| Size Resolution | ≤15% (vs. 0.3 µm PSL) |
| Operating Temp. | 15–35 °C, RH: 0–85% non-condensing |
| Dimensions | 150 × 163 × 228 mm |
| Weight | 3.4 kg |
| Display | 4.3" color TFT touchscreen |
| Interface | USB Host/Device, Ethernet, RS-485 (9600–38400 baud) |
| Data Storage | Internal CSV (up to 10,000 records) |
| Compliance | JIS B9921, ISO 21501-4 |