KANOMAX
Filter
Showing 481–500 of 500 results
| Brand | Kanomax |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Instrument Type | Online Particle Counter |
| Flow Rate | 28.3 L/min (1 CFM) |
| Particle Size Channels | 0.3 & 0.5 μm (3718-A) / 0.5 & 5.0 μm (3719-A) |
| Light Source | Long-life Laser Diode |
| Compliance | ISO 21501-4, JIS B 9921, ISO 14644-1:2015 |
| Data Storage | 2,000 Sample Records with Redundant Backup |
| Output Interfaces | RS485, Modbus RTU/TCP/IP, 4–20 mA Analog Output |
| Power Supply | DC 9–28 V, PoE, or AC 100–240 V |
| Enclosure Material | 316 Stainless Steel with VHP/Alcohol-Vapor Resistant Sealing |
| Operating Environment | 10–30 °C, 20–85% RH (non-condensing) |
| Dimensions | 133 × 95 × 80 mm |
| Weight | 1.0 kg |
| Brand | Kanomax |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | 3720-06 |
| Pricing | Available Upon Request |
| Particle Size Channels | Selectable 2–4 channels from 0.3, 0.5, 0.7, 1.0, 3.0, 5.0, 10.0 µm (standard configuration: 0.5 & 5.0 µm) |
| Flow Rate | 28.3 L/min (1.0 CFM) |
| Light Source | Long-life laser diode |
| Counting Efficiency | Compliant with ISO 21501-4 and JIS B 9921 |
| Max. Detectable Concentration | 1,000,000 particles/ft³ |
| Data Storage | 5,000 measurement records (2,000 in volatile buffer with redundancy) |
| Housing Material | 316 stainless steel with VHP- and ethanol vapor-resistant sealed enclosure |
| Vacuum Sampling Pump | Removable and serviceable |
| Power Supply | DC 15–28 V, PoE (IEEE 802.3af), or AC 100–240 V |
| Communication Interfaces | Ethernet (Modbus TCP/IP), RS-485 (Modbus RTU), 4–20 mA analog output |
| Alarm Output | Configurable 0–100% threshold, relay ON/OFF |
| Operating Environment | 10–30 °C, 20–85% RH (non-condensing) |
| Storage Conditions | −10–50 °C, ≤95% RH (non-condensing) |
| Dimensions | 180 × 110 × 190 mm |
| Weight | 4.0 kg |
| Brand | KANOMAX |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | 3720-06 |
| Instrument Type | Online Particle Counter |
| Flow Rate | 28.3 L/min (1.0 CFM) |
| Detectable Particle Sizes | 0.3, 0.5, 0.7, 1.0, 3.0, 5.0, 10.0 µm (user-selectable 2–4 channels, factory-configured) |
| Light Source | Long-life laser diode |
| Counting Efficiency | Compliant with ISO 21501-4 and JIS B9921 |
| Max. Concentration | 1,000,000 particles/ft³ |
| Data Storage | 5,000 records (2,000-record buffer + redundancy backup) |
| Enclosure Material | 316 stainless steel with VHP- and ethanol vapor-resistant sealing |
| Vacuum Sampling Pump | Removable and serviceable |
| Power Supply | DC 15–28 V, PoE (IEEE 802.3af), or AC 100–240 V |
| Communication | Ethernet (Modbus TCP/IP), RS-485 (Modbus RTU), 4–20 mA analog output |
| Operating Environment | 10–30 °C, 20–85% RH (non-condensing) |
| Dimensions | 180 × 110 × 190 mm |
| Weight | 4.0 kg |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | S0104-4 |
| Steam Output Rate | 65–390 g/h |
| Steam Reservoir Capacity | 3.785 L (externally insulated) |
| Heater Power | ≤500 W (AC 100 V) |
| Thermal Loss | <75 W at −3 °C ±1 °C |
| Nozzle Internal Diameter | Φ15 mm, Length: 100 mm |
| Exhaust Fan Flow Rate | 0.05–0.1 m³/min at 49 Pa |
| Compliance | SAE J953 (JUN1984), EEC Regulation No. 317, GB 11555–2009 |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | S0104-4 |
| Steam Output | 65–390 g/h |
| Thermal Loss | <75 W at –3 °C ±1 °C |
| Water Reservoir Capacity | 3.785 L (externally insulated) |
| Heater Power | up to 500 W, AC 100 V |
| Nozzle ID | Φ15 mm, Length: 100 mm |
| Exhaust Fan Flow | 0.05–0.1 m³/min at 49 Pa |
| Output Orifices | six × Φ6.3 mm |
| Compliance | SAE J953 (JUN84), EEC/317, GB 11555–2009 |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | S0104-4 |
| Steam Output | 65–390 g/h |
| Steam Reservoir Capacity | 3.785 L (externally insulated) |
| Heating Power | up to 500 W AC 100 V |
| Thermal Loss | <75 W at ambient –3 °C ±1 °C |
| Nozzle ID | Φ15 mm, Length: 100 mm |
| Exhaust Fan Flow Rate | 0.05–0.1 m³/min @ 49 Pa |
| Orifice Configuration | 6 × Φ6.3 mm top-mounted steam outlets |
| Compliance | SAE J953 (JUN84), EEC/317, GB 11555–2009 |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | S0104-4 |
| Steam Output Rate | 65–390 g/h |
| Thermal Loss | <75 W (at ambient –3 °C ±1 °C) |
| Water Reservoir Capacity | 3.785 L (externally insulated) |
| Heater Power | up to 500 W, AC 100 V |
| Nozzle Internal Diameter | Φ15 mm, Length: 100 mm |
| Exhaust Fan Flow Rate | 0.05–0.1 m³/min (at 49 Pa) |
| Output Orifices | six × 6.3 mm diameter ports on top |
| Compliance | SAE J953 JUN84, EEC/317, GB 11555–2009 |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | S0521395 |
| Maximum Air Velocity | 10 m/s |
| Footprint | Benchtop-Installed, No External Support Frame Required |
| Compliance | Designed for ISO/IEC 17025-aligned laboratory environments |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | S980338 |
| Maximum Airflow Velocity | 10 m/s |
| Tunnel Cross-Section | Standard Eiffel Profile (Typical 150 mm × 150 mm test section) |
| Flow Quality | Laminar, Turbulence Intensity < 0.5% (at centerline, nominal speed) |
| Construction | Precision-machined aluminum alloy frame with optical-grade acrylic viewing windows |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Noise Level | ≤ 58 dB(A) at 1 m |
| Dimensions (L×W×H) | Approx. 1200 × 600 × 850 mm |
| Weight | ~75 kg |
| Compliance | CE marked, RoHS compliant |
| Optional Integration | PIV/LDV/PDI synchronization ports, particle seeding inlet, temperature/humidity monitoring interface |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | S980349 |
| Maximum Air Velocity | 33 m/s |
| Test Section Cross-Section (Max) | 300 mm × 300 mm |
| Test Section Length | 1050 mm |
| Overall Dimensions | 1150 mm (W) × 1475 mm (H) × 5410 mm (L) |
| Weight | 650 kg |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | SDM-II |
| Measurement Range | 0.01–10.00 mg/m³ |
| Resolution | 0.01 mg/m³ |
| Accuracy | ±10% |
| Relative Error | ≤±2% |
| Sampling Flow Rate | 1.7 L/min |
| Detection Principle | Laser Scattering (90° Forward Light Scattering) |
| Safety Rating | Non-Explosive |
| Communication Interface | RS485 |
| Zero & Span Auto-Calibration | Yes |
| Alarm Threshold Setting | Yes |
| Built-in Dehumidification | Yes |
| Filter Membrane Sampling Module | Included |
| Compliance | ISO 12103-1 A2 Fine Test Dust Compatible, Meets JIS B 7960 for Optical Dust Monitors |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | SDM-II |
| Measurement Principle | Laser Light Scattering |
| Particle Size Range | PM2.5, PM10, TSP |
| Measurement Range | 0.001–30.000 mg/m³ |
| Resolution | 0.01 mg/m³ |
| Accuracy | ±10% |
| Relative Error | ≤±2% |
| Sampling Flow Rate | 1.7 L/min |
| Zero & Span Auto-Calibration | Yes |
| Alarm Threshold Setting | Yes |
| Automatic Dehumidification | Yes |
| Communication Interface | RS485 |
| Power Supply | DC 10–15 V, 2 A |
| Dimensions (w/o case) | 250 × 350 × 170 mm |
| Weight (w/o case) | ~4.5 kg |
| Weight (with case) | ~8 kg |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | SDM-II+ |
| Measurement Principle | Laser Light Scattering |
| Particle Size Range | PM2.5, PM10, TSP |
| Measurement Range | 0.01–10.00 mg/m³ |
| Resolution | 0.01 mg/m³ |
| Accuracy | ±10% |
| Relative Error | ≤±2% |
| Sampling Flow Rate | 1.7 L/min |
| Zero & Span Auto-Calibration | Yes |
| Humidity Compensation | Integrated Automatic Dehumidification |
| Alarm Threshold Setting | Configurable Concentration Limit |
| Communication Interface | RS485 |
| Power Supply | DC 10–15 V, 2 A |
| Dimensions (W×H×D) | 250 × 350 × 170 mm (unit only) |
| Weight | ~4.5 kg (unit only) |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | Dependent on Interchangeable Probe (e.g., 0–30 m/s for standard hot-wire probe) |
| Accuracy | ±2% of reading |
| Operating Temperature | −20 to +70 °C |
| Operating Humidity | 2.0–98.0% RH |
| Data Storage Capacity | Up to 20,000 records |
| Probe Compatibility | 8 interchangeable probe types (hot-wire, vane, pitot tube, and specialized duct probes) |
| Built-in Calculations | Volumetric flow (m³/h, CFM) via user-defined duct geometry (rectangular, circular, oval cross-sections with dimensional input) |
| Statistical Functions | Real-time min/max/average, hold function |
| Accessories Included | 2 m probe cable, carrying case, operator manual |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.01 m/s |
| Accuracy | ±2% of reading |
| Operating Temperature Range | −20 °C to +70 °C |
| Operating Relative Humidity Range | 2.0–98.0% RH |
| Probe Compatibility | 8 interchangeable thermal anemometry probes (hot-wire/hot-film) |
| Data Storage Capacity | Up to 20,000 measurement records |
| Built-in Calculations | Real-time air volume (m³/h or CFM) via user-defined duct geometry (rectangular, circular, oval cross-sections with dimensional input) |
| On-device Statistics | Min/Max/Avg values with hold function |
| Standard Accessories | 2 m probe cable × 1, carrying case × 1, operator manual |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | Smart LDV II |
| Velocity Range | –40 to +100 m/s |
| Laser Source | Laser Diode, λ = 660 nm, 60 mW |
| Focal Distances | 150 / 200 / 250 / 300 / 350 / 400 mm |
| Focal Spot Size | 0.13 mm × 0.13 mm |
| Probe Dimensions | 61 mm (dia.) × 312 mm (length) |
| Doppler Shift Frequency Range | 0.01–10 MHz |
| Probe Weight | 2.5 kg |
| Signal Processor (Model 8008) | 8-bit FFT, 1 kHz–40 MHz bandwidth, 16,000 data points/sec, full-size PCI board |
| Traverse System | 3-axis, max vertical load 7 kg, translation speed 80 mm/sec, positioning accuracy ±0.025 mm |
| Interface | RS232C, BNC I/O, interlock connector |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | SmartLDV III |
| Laser Wavelength | 660 nm |
| Laser Power | 60 mW |
| Velocity Range | –40 to +264 m/s (at 400 mm focal distance, model 8743-S) |
| Focal Distances | 150, 200, 250, 300, 350, 400 mm |
| Spot Size | 0.13 mm × 1.3 mm (f = 200 mm) |
| Probe Dimensions | Ø61 mm × 345 mm |
| Probe Weight | 3.5 kg |
| Frequency Shift Range | 0.01–10 MHz |
| Signal Processor | KANOMAX Model 8008 |
| FFT Resolution | 8-bit |
| Frequency Bandwidth | 1 kHz – 40 MHz |
| Input Signal Range | 20 mV – 1 V (Doppler signal) |
| Data Acquisition Rate | 16,000 samples/sec |
| 3-Axis Traverse Stage | Max. vertical load 7 kg |
| Traverse Speed | 80 mm/sec |
| Positioning Accuracy | ±0.025 mm |
| Interface | RS232C |
| Compliance | CE-marked |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 8745-S |
| Laser Wavelength | 660 nm |
| Laser Power | 60 mW |
| Velocity Range | –40 to +264 m/s (at 400 mm focal distance, model 8745-S) |
| Focal Distances | 150, 200, 250, 300, 350, 400 mm |
| Spot Size | 0.13 mm × 1.3 mm (f = 200 mm) |
| Probe Dimensions | Ø61 mm × 345 mm |
| Probe Weight | 3.5 kg |
| Frequency Shift Range | 0.01–10 MHz |
| Signal Processor | SmartLDV Model 8008 |
| FFT Resolution | 8-bit |
| Frequency Bandwidth | 1 kHz – 40 MHz |
| Input Signal Range | 20 mV – 1 V |
| Data Acquisition Rate | 16,000 samples/sec |
| 3-Axis Traverse System | Max. vertical load 7 kg, travel speed 80 mm/sec, positioning accuracy ±0.025 mm |
| Interface | RS232C |
| Compliance | CE-marked, RoHS-compliant, designed for ISO/IEC 17025-aligned laboratory environments |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Kanomax SXYC-508 |
| Operating Principle | Optical Scattering (β-ray attenuation & integrated gravimetric verification) |
| Safety Rating | Non-explosion-proof |
| Dust Measurement Range | 0.01–10.00 mg/m³ |
| Resolution | 0.01 mg/m³ |
| Accuracy | ±10% |
| Relative Error | ≤±2% |
| Noise Range | 30–130 dB(A) |
| Noise Accuracy | ±0.5 dB |
| Atmospheric Pressure Range | 10–1100 hPa |
| Pressure Accuracy | ±0.3 hPa |
| Wind Speed Range | 0.00–70.0 m/s |
| Wind Speed Accuracy | ±0.03 m/s |
| Wind Direction Range | 0–360° |
| Direction Accuracy | ±0.5° |
| Temperature Range | −50–100°C |
| Humidity Range | 0–100% RH |
| Temp/Humidity Accuracy | ±0.5°C / ±3% RH |
| Power Consumption | 30 W |
| Power Supply | AC 220 V ±10% with backup battery (≥6 h runtime) |
| Data Protocol Compliance | HJ/T 212–2005 |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | SXYC-508 |
| Measurement Range | 0.01–10.00 mg/m³ |
| Resolution | 0.01 mg/m³ |
| Accuracy | ±10% |
| Relative Error | ≤±2% |
| Safety Classification | Non-explosion-proof |
| Compliance Standard | HJ/T 212–2005 |
| Detection Principle | Beta-ray attenuation (integrated gravimetric reference via filter sampling) |