KANOMAX
Filter
Showing 91–120 of 500 results
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 3950-00 |
| Flow Rate | 2.83 L/min (0.1 CFM) |
| Flow Accuracy | ±5% |
| Timing Accuracy | ±1 s per 6 min |
| Repeatability | ±5% |
| Size Distribution Error | ±15% |
| Indication Error | ±30% |
| Particle Detection Channels | 0.1 µm and 0.3 µm |
| Counting Efficiency | 50 ± 20% at 0.1 µm (PSL), 100 ± 10% at 0.15–0.2 µm (PSL) |
| Maximum Concentration | 10⁷ particles/m³ |
| False Count Rate | <1 count per 35 min |
| Size Resolution | ≤15% (relative to 0.3 µm PSL) |
| Display | 4.3″ color TFT touchscreen |
| Communication | USB (Host/Device), Ethernet, RS-485 (9600–38400 baud) |
| Data Storage | up to 10,000 records in CSV format |
| Operating Environment | 15–35 °C, 0–85% RH (non-condensing) |
| Dimensions | 150 × 163 × 228 mm |
| Weight | 3.4 kg |
| Compliance | JIS B9921, ISO 21501-4 |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 3950-00 |
| Flow Rate | 2.83 L/min (0.1 CFM) |
| Flow Accuracy | ±5% |
| Timing Accuracy | ±1 s per 6 min |
| Repeatability | ±5% |
| Size Distribution Error | ±15% |
| Indication Error | ±30% |
| Particle Detection Threshold | 0.1 µm and 0.3 µm |
| Compliance | JIS B9921 & ISO 21501-4 |
| Display | 4.3" color TFT touchscreen |
| Communication | RS-485, Ethernet, USB Host/Device |
| Data Storage | Up to 10,000 records (CSV) |
| Operating Environment | 15–35 °C, 0–85% RH (non-condensing) |
| Dimensions | 150 × 163 × 228 mm |
| Weight | 3.4 kg |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 3950-00 |
| Flow Rate | 2.83 L/min (0.1 CFM) |
| Flow Accuracy | ±5% |
| Timing Accuracy | ±1 s per 6 min |
| Repeatability | ±5% |
| Size Distribution Error | ±15% |
| Indication Error | ±30% |
| Particle Detection Channels | 0.1 μm, 0.3 μm |
| Compliance | JIS B9921 & ISO 21501-4 |
| Max Concentration | 10⁷ particles/m³ |
| Counting Efficiency | 50±20% at 0.1 μm (PSL), 100±10% at 0.15–0.2 μm (PSL) |
| False Count Rate | <1 count/35 min |
| Size Resolution | ≤15% (relative to 0.3 μm PSL) |
| Display | 4.3" color TFT touchscreen |
| Communication | USB (Host/Device), Ethernet, RS-485 (9600–38400 baud) |
| Data Storage | 10,000 records, CSV format |
| Operating Environment | 15–35 °C, 0–85% RH (non-condensing) |
| Dimensions | 150 × 163 × 228 mm |
| Weight | 3.4 kg |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3950-00 |
| Flow Rate | 2.83 L/min (0.1 CFM) |
| Flow Accuracy | ±5% |
| Timing Accuracy | ±1 s per 6 min |
| Repeatability | ±5% |
| Size Distribution Error | ±15% |
| Indication Error | ±30% |
| Particle Detection Channels | 0.1 μm & 0.3 μm |
| Measurement Principle | Light Scattering |
| Compliance | JIS B9921 & ISO 21501-4 |
| Max Concentration | 10⁷ particles/m³ |
| Counting Efficiency | 50±20% at 0.1 μm (PSL), 100±10% at 0.15–0.2 μm (PSL) |
| False Count Rate | <1 count/35 min |
| Size Resolution | ≤15% (relative to 0.3 μm PSL) |
| Display | 4.3″ color TFT touchscreen |
| Interface | USB (Host/Device), Ethernet, RS-485 (9600–38400 baud) |
| Data Storage | 10,000 records (CSV) |
| Operating Environment | 15–35°C, 0–85% RH (non-condensing) |
| Dimensions | 150 × 163 × 228 mm |
| Weight | 3.4 kg |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 3950-00 |
| Flow Rate | 2.83 L/min (0.1 CFM) |
| Flow Accuracy | ±5% |
| Timing Accuracy | ±1 s per 6 min |
| Repeatability | ±5% |
| Size Distribution Error | ±15% |
| Indication Error | ±30% |
| Particle Detection Channels | 0.1 μm & 0.3 μm |
| Max Concentration | 10⁷ particles/m³ |
| Counting Efficiency | 50±20% @ 0.1 μm (PSL), 100±10% @ 0.15–0.2 μm (PSL) |
| False Count Rate | <1 count/35 min |
| Size Resolution | ≤15% (vs. 0.3 μm PSL) |
| Display | 4.3″ color TFT touchscreen |
| Communication | RS-485, Ethernet (10/100BASE-T), USB Host/Device |
| Data Storage | internal memory (10,000 records, CSV) |
| Operating Environment | 15–35 °C, 0–85% RH (non-condensing) |
| Dimensions | 150 × 163 × 228 mm |
| Weight | 3.4 kg |
| Compliance | JIS B9921, ISO 21501-4 |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 3950-00 |
| Flow Rate | 2.83 L/min (0.1 CFM) |
| Flow Accuracy | ±5% |
| Timing Accuracy | ±1 s per 6 min |
| Repeatability | ±5% |
| Size Distribution Error | ±15% |
| Indication Error | ±30% |
| Particle Detection Channels | 0.1 μm & 0.3 μm |
| Compliance | JIS B9921 & ISO 21501-4 |
| Display | 4.3" Color Touchscreen LCD |
| Communication | RS-485, Ethernet, USB (Host/Device) |
| Data Storage | Up to 10,000 records (CSV) |
| Operating Environment | 15–35 °C, 0–85% RH (non-condensing) |
| Dimensions | 150 × 163 × 228 mm |
| Weight | 3.4 kg |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3950-00 |
| Flow Rate | 2.83 L/min (0.1 CFM) |
| Flow Accuracy | ±5% |
| Timing Accuracy | ±1 s per 6 min |
| Repeatability | ±5% |
| Size Distribution Error | ±15% |
| Indication Error | ±30% |
| Particle Detection Channels | 0.1 μm & 0.3 μm |
| Compliance | JIS B9921 & ISO 21501-4 |
| Display | 4.3" Color Touchscreen LCD |
| Communication | RS-485, Ethernet, USB (Host/Device) |
| Data Storage | Up to 10,000 records (CSV) |
| Operating Environment | 15–35 °C, 0–85% RH (non-condensing) |
| Dimensions | 150 × 163 × 228 mm |
| Weight | 3.4 kg |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 6006 |
| Instrument Type | Thermal Anemometer |
| Measurement Range | 0.01–20.0 m/s |
| Resolution | 0.01 m/s (0.01–9.99 m/s), 0.1 m/s (10.0–20.0 m/s) |
| Accuracy | ±5% of reading |
| Operating Temperature | −20 to +70 °C |
| Operating Humidity | 20–85% RH |
| Temperature Compensation | Integrated circuit for enhanced accuracy within 10–40 °C |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 6006 |
| Instrument Type | Thermal Anemometer |
| Measurement Range | 0.01–20.0 m/s |
| Resolution | 0.01 m/s (0.01–9.99 m/s), 0.1 m/s (10.0–20.0 m/s) |
| Accuracy | ±5% of reading |
| Operating Temperature | −20 to +70 °C |
| Operating Humidity | 20–85% RH |
| Temperature Compensation | Active compensation circuit optimized for 10–40 °C range |
| Sensor Element | Platinum-wire hot-wire anemometer |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 6006 |
| Instrument Type | Thermal Anemometer |
| Measurement Range | 0.01–20.0 m/s |
| Resolution | 0.01 m/s (0–9.99 m/s), 0.1 m/s (10.0–20.0 m/s) |
| Accuracy | ±5% of reading (wind speed), ±1°C (temperature) |
| Operating Temperature | −20–70°C (probe), 5–40°C (main unit) |
| Operating Humidity | 20–85% RH |
| Response Time | <1 s (90% for wind speed at 1 m/s), <30 s (90% for temperature) |
| Display | Dual-parameter (wind speed + temperature), 4-level battery indicator, FAST/SLOW averaging (1 s / 5 s), unit toggle (m/s/°C ↔ fpm/°F), hold function |
| Probe Dimensions | Ø6.1 mm (Ø10.6 mm tip) × 205 mm |
| Cable | Ø3.3 mm × ~1.5 m |
| Main Unit Dimensions | 60 × 120 × 30 mm |
| Weight | ~180 g (incl. batteries) |
| Compliance | Designed for ISO 7726-compliant thermal comfort and HVAC airflow verification |
| Brand | Kanomax |
|---|---|
| Origin | China (Liaoning) |
| Model | 6006 |
| Instrument Type | Thermal Anemometer |
| Velocity Range | 0.01–20.0 m/s |
| Velocity Resolution & Accuracy | ±5% of reading |
| Temperature Range | −20 to +70 °C |
| Temperature Accuracy | ±1.0 °C |
| Power Supply | 4 × AA batteries |
| Dimensions | 60 × 120 × 34 mm |
| Weight | 180 g |
| Operating Ambient Temperature | −20 to +70 °C |
| Brand | KANOMAX |
|---|---|
| Origin | Liaoning, China (Distributed by Authorized KANOMAX Representative) |
| Model | 6006 |
| Instrument Type | Thermal Anemometer |
| Velocity Range | 0.01–20.0 m/s |
| Velocity Accuracy | ±5% of reading |
| Velocity Resolution | ±5% of reading |
| Temperature Range | −20 to +70 °C |
| Temperature Accuracy | ±1.0 °C |
| Power Supply | 4 × AA batteries |
| Dimensions | 60 × 120 × 34 mm |
| Weight | 180 g |
| Operating Ambient Temperature | −20 to +70 °C |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 6006 |
| Instrument Type | Thermal Anemometer |
| Measurement Range | 0.01–20.0 m/s |
| Resolution | 0.01 m/s (0–9.99 m/s), 0.1 m/s (10.0–20.0 m/s) |
| Accuracy | ±5% of reading (wind speed), ±1°C (temperature) |
| Operating Temperature | −20–70°C (probe), 5–40°C (main unit) |
| Operating Humidity | 20–85% RH |
| Response Time | <1 s (90% for wind speed at 1 m/s), <30 s (90% for temperature) |
| Display | Dual-parameter (wind speed & temperature), 4-segment battery indicator, FAST/SLOW averaging (1 s / 5 s), unit toggle (m/s/°C ↔ fpm/°F), hold function |
| Probe Dimensions | Ø6.1 mm (Ø10.6 mm at tip) × 205 mm |
| cable | Ø3.3 mm × ~1.5 m |
| Main Unit Dimensions | 60 × 120 × 30 mm |
| Weight | ~180 g (including batteries) |
| Storage Temperature | −10–50°C |
| Accessories | Instruction manual, carrying case |
| Optional Accessories | Extension rod, replacement probe |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 6006 |
| Instrument Type | Thermal Anemometer |
| Measurement Range | 0.01–20.0 m/s |
| Resolution | 0.01 m/s (0.01–9.99 m/s) |
| Accuracy | ±5% of reading (m/s) |
| Temperature Range | −20 to +70 °C |
| Temperature Accuracy | ±1.0 °C |
| Relative Humidity Operating Range | 20–85% RH |
| Power Supply | 4 × AA batteries |
| Dimensions | 60 × 120 × 34 mm |
| Weight | 180 g |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 6006 |
| Instrument Type | Hot-Wire Anemometer |
| Measurement Range | 0.01–20.0 m/s |
| Resolution | 0.01 m/s (0.01–9.99 m/s) |
| Accuracy | ±5% of reading (wind speed) |
| Operating Temperature | −20 to +70 °C |
| Operating Humidity | 20–85% RH |
| Power Supply | 4 × AA batteries |
| Dimensions | 60 × 120 × 34 mm |
| Weight | 180 g |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 6006 |
| Instrument Type | Hot-Wire Anemometer |
| Velocity Range | 0.01–20.0 m/s |
| Resolution | 0.01 m/s (0.01–9.99 m/s) |
| Accuracy | ±5% of reading |
| Temperature Range | −20 to +70 °C |
| Temperature Accuracy | ±1.0 °C |
| Operating Humidity | 20–85% RH |
| Power Supply | 4 × AA batteries |
| Dimensions | 60 × 120 × 34 mm |
| Weight | 180 g |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 6006 |
| Instrument Type | Hot-Wire Anemometer |
| Measurement Range | 0.01–20.0 m/s |
| Resolution | 0.01 m/s (0.01–9.99 m/s) |
| Accuracy | ±5% of reading (wind speed) |
| Operating Temperature | −20 to +70 °C |
| Operating Humidity | 20–85% RH |
| Power Supply | 4 × AA batteries |
| Dimensions | 60 × 120 × 34 mm |
| Weight | 180 g |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 6006 |
| Instrument Type | Hot-Wire Anemometer |
| Measurement Range | 0.01–20.0 m/s |
| Resolution | 0.01 m/s (0.01–9.99 m/s) |
| Accuracy | ±5% of reading (wind speed) |
| Operating Temperature | −20 to +70 °C |
| Operating Humidity | 20–85% RH (non-condensing) |
| Power Supply | 4 × AA batteries |
| Dimensions | 60 × 120 × 34 mm |
| Weight | 180 g |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 6006 |
| Instrument Type | Hot-wire Anemometer |
| Measurement Range | 0.01–20.0 m/s |
| Resolution | 0.01 m/s (0.01–9.99 m/s), 0.1 m/s (10.0–20.0 m/s) |
| Accuracy | ±5% of reading (wind speed), ±1°C (temperature) |
| Operating Temperature | −20 to +70°C (air), 0 to +50°C (probe), +5 to +40°C (main unit) |
| Operating Humidity | 20–85% RH |
| Response Time | <1 s (90% for wind speed at 1 m/s), <30 s (90% for temperature at 1 m/s) |
| Display | Dual-parameter (wind speed + temperature), selectable units (m/s/°C or fpm/°F), FAST/SLOW averaging (1 s / 5 s), battery level indicator (4-segment), hold function |
| Probe Dimensions | Ø6.1 mm (Ø10.6 mm at sensor tip) × 205 mm |
| cable | Ø3.3 mm × ~1.5 m |
| Main Unit Dimensions | 60 × 120 × 34 mm |
| Weight | ~180 g (including batteries) |
| Storage Temperature | −10 to +50°C |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 6006 |
| Instrument Type | Thermal Anemometer |
| Measurement Range | 0.01–20.0 m/s |
| Resolution | 0.01 m/s (0–9.99 m/s), 0.1 m/s (10.0–20.0 m/s) |
| Accuracy | ±5% of reading (wind speed), ±1°C (temperature) |
| Operating Temperature | −20–70°C (probe), 5–40°C (main unit) |
| Operating Humidity | 20–85% RH |
| Response Time | <1 s (90% for wind speed at 1 m/s), <30 s (90% for temperature) |
| Display | Dual-parameter (wind speed & temperature), 4-level battery indicator, FAST/SLOW averaging (1 s / 5 s), unit toggle (m/s/°C ↔ fpm/°F), hold function |
| Probe Dimensions | Ø6.1 mm (Ø10.6 mm at tip) × 205 mm |
| Cable | Ø3.3 mm × ~1.5 m |
| Main Unit Dimensions | 60 × 120 × 30 mm |
| Weight | ~180 g (including batteries) |
| Compliance | Designed for ISO/IEC 17025-aligned field verification and HVAC commissioning workflows |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 6006 |
| Instrument Type | Thermal Anemometer |
| Measurement Range | 0.01–20.0 m/s |
| Resolution | 0.01 m/s (0.01–9.99 m/s), 0.1 m/s (10.0–20.0 m/s) |
| Temperature Range | −20 to +70 °C (air), 0 to +50 °C (probe), +5 to +40 °C (body) |
| Accuracy | ±5% of reading (wind speed), ±1 °C (temperature) |
| Response Time | <1 s (90% for wind speed at 1 m/s), <30 s (90% for temperature at 1 m/s) |
| Display | Dual-parameter (wind speed + air temperature), unit switchable (m/s/°C ↔ fpm/°F), FAST/SLOW averaging (1 s / 5 s), battery level indicator (4-level), hold function |
| Probe Dimensions | Ø6.1 mm (Ø10.6 mm with sheath) × 205 mm |
| cable | Ø3.3 mm × ~1.5 m |
| Main Unit Dimensions | 60 × 120 × 34 mm |
| Weight | ~180 g (including batteries) |
| Storage Temp. | −10 to +50 °C |
| Compliance | Designed for laboratory, HVAC, and industrial airflow verification per ISO 16813, ASHRAE Guideline 12, and JIS B 7555 standards |
| Brand | Kanomax |
|---|---|
| Model | 6036-0C / 6036-BC |
| Type | Thermal Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0.01–30.0 m/s |
| Accuracy | ±3% of reading (wind speed), ±0.5 °C (temperature), ±3% of reading (pressure, –0.00 to ±5 kPa) |
| Operating Temperature | –20 °C to +70 °C |
| Operating Humidity | 0–100% RH |
| Data Storage Capacity | 1500 records |
| Interface | USB |
| Dimensions | 66 × 51 × 188 mm |
| Weight | 400 g (without batteries) |
| Probe | Flexible and telescopic |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 6036 |
| Instrument Type | Thermal Anemometer |
| Measurement Range | 0.01–30.0 m/s |
| Accuracy | ±3% of reading + 0.03 m/s |
| Resolution | ±2% of reading |
| Operating Temperature | −20 to +70 °C |
| Operating Humidity | 2.0–98.0 %RH |
| Data Storage Capacity | 1500 sets |
| Probe | Articulating and telescoping |
| Output | Real-time USB data streaming with PC software support |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 6036 |
| Instrument Type | Thermal Anemometer |
| Measurement Range | 0.01–30.0 m/s |
| Accuracy | ±3% of reading or ±0.03 m/s (whichever is greater) |
| Resolution | ±2% of reading |
| Operating Temperature | −20 to +70 °C |
| Operating Humidity | 2.0–98.0 %RH |
| Data Storage Capacity | 1,500 measurement sets |
| Output Interface | USB for PC connectivity |
| Probe | Flexible, telescoping stainless-steel probe with integrated temperature sensor |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Instrument Type | Thermal Anemometer |
| Measurement Range | 0.01–30.0 m/s |
| Resolution | ±2% of reading |
| Accuracy | ±3% of reading (wind speed), ±0.5°C (temperature), ±3% of reading (pressure, -0.00 to ±5 kPa) |
| Operating Temperature | -20 to +70°C |
| Operating Humidity | 2.0–98.0% RH |
| Data Storage Capacity | 1500 sets |
| Interface | USB |
| Dimensions | 66 × 51 × 188 mm |
| Weight | 400 g (without batteries) |
| Probe | Flexible and telescopic |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 6036-0C / 6036-BC |
| Instrument Type | Thermal Anemometer |
| Velocity Range | 0.01–30.0 m/s |
| Velocity Accuracy | ±3% of reading |
| Velocity Resolution | ±2% of reading |
| Temperature Range | −20 to +70 °C |
| Temperature Accuracy | ±0.5 °C |
| Pressure Range | −5.0 to +5.0 kPa |
| Pressure Accuracy | ±3% of reading |
| Humidity Range | 2.0–98.0 %RH |
| Data Storage Capacity | 1,500 records |
| Interface | USB |
| Dimensions | 66 × 51 × 188 mm |
| Weight | 400 g (battery excluded) |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Instrument Type | Thermal Anemometer |
| Measurement Range | 0.01–30.0 m/s |
| Accuracy | ±3% of reading (wind speed), ±0.5 °C (temperature), ±3% of reading (pressure, ±5 kPa full scale) |
| Resolution | ±2% of reading |
| Operating Temperature | −20 to +70 °C |
| Operating Humidity | 2.0–98.0% RH |
| Data Storage Capacity | 1500 records |
| Interface | USB |
| Dimensions | 66 × 51 × 188 mm |
| Weight | 400 g (without batteries) |
| Compliance | Designed for ISO 14644-1/3 cleanroom qualification, GMP-compliant environmental monitoring workflows |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Instrument Type | Thermal Anemometer |
| Measurement Range | 0.01–30.0 m/s |
| Accuracy | ±3% of reading (m/s) |
| Resolution | ±2% of reading |
| Temperature Range | −20 to +70 °C |
| Temperature Accuracy | ±0.5 °C |
| Pressure Range (6036-BC only) | −5.0 to +5.0 kPa |
| Pressure Accuracy | ±3% of reading |
| Operating Humidity | 2.0–98.0% RH |
| Data Storage Capacity | 1,500 records |
| Interface | USB |
| Dimensions | 66 × 51 × 188 mm |
| Weight | 400 g (without batteries) |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 6036-0C / 6036P-BC |
| Instrument Type | Thermal Anemometer |
| Velocity Range | 0.01–30.0 m/s |
| Accuracy | ±3% of reading (velocity), ±0.5 °C (temperature), ±3% of reading (pressure, 6036P-BC only) |
| Resolution | ±2% of reading |
| Operating Temperature | −20 to +70 °C |
| Operating Humidity | 2.0–98.0% RH |
| Data Storage | 1500 measurement sets |
| Interface | USB |
| Dimensions | 66 × 51 × 188 mm |
| Weight | 400 g (without batteries) |
| Probe | Telescoping and flexible |
| Brand | Kanomax |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | 6036-0C |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0.01–30.0 m/s |
| Accuracy | ±3% of reading |
| Operating Temperature | −20 to +70 °C |
| Operating Humidity | 0–100% RH |
| Temperature Range | −20 to +70 °C |
| Temperature Accuracy | ±0.5 °C |
| Pressure Range | −5.0 to +5.0 kPa |
| Pressure Accuracy | ±3% of reading |
| Data Storage Capacity | 1500 records |
| Interface | USB |
| Dimensions | 66 × 51 × 188 mm |
| Weight | 400 g (without batteries) |