| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | StrainMaster 2D-/3D Stereo |
| Type | Stereoscopic Digital Image Correlation (DIC) System |
| Measurement Capability | Full-field 2D in-plane and 3D surface displacement & strain tensor mapping |
| Camera Configuration | Dual high-resolution synchronized cameras with calibrated stereo geometry |
| Calibration Standard | ISO/IEC 17025 traceable volumetric calibration protocol |
| Data Output Format | ASCII, HDF5, MATLAB .mat, DIC-compatible binary |
| Software Platform | DaVis v10.3+ with real-time correlation engine |
| Compliance | Supports GLP/GMP audit trails, ASTM E837–22 (strain measurement validation), ISO 12232 (image sensor characterization) |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | Calibration Plates |
| Type | Empirical Multi-Plane Stereo Camera Calibration Target |
| Material | Precision-Coated Optical Glass or Fluorescent Orange Glass (Green-Light Excitable) |
| Compliance | Designed for VDI 2626-compliant uncertainty quantification |
| Application Domain | Digital Image Correlation (DIC), Full-Field Strain & Displacement Measurement |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | StrainMaster Compact |
| Pricing | Available Upon Request |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | StrainMaster DIC |
| Software Type | Simulation & Full-Field Deformation Analysis Platform |
| Camera Compatibility | Up to two Imager M-lite or Imager X-lite series cameras |
| Integrated Hardware Support | StrainMaster Controller (with integrated ADC), StrainMaster LED line light units (pulsed or CW) |
| Core Functionality | Full-field 2D/3D surface displacement, strain, and shape measurement via Digital Image Correlation (DIC) |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | StrainMaster-sys |
| Type | Turnkey Optical DIC System for Full-Field Deformation, Displacement & Strain Measurement |
| Compliance | Designed for ASTM E837, ISO/IEC 17025-aligned laboratory environments, supports GLP/GMP data integrity requirements via DaVis software audit trail functionality |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | StrainMaster |
| Type | Turnkey Optical Deformation & Strain Analysis System |
| Core Technologies | 2D/3D Stereo Digital Image Correlation (DIC), Digital Volume Correlation (DVC) |
| Compatible Imaging Modalities | X-ray CT, MRI, OCT, high-speed visible-light imaging |
| Application Domain | Solid mechanics, granular material deformation, composite testing, biomechanics, additive manufacturing validation |
| Compliance Framework | Designed for GLP/GMP-aligned workflows |
| Software Architecture | Windows-based, modular, scriptable (Python API), compliant with FDA 21 CFR Part 11 for electronic records and signatures (optional configuration) |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | StrainMaster DVC |
| Application Domain | 3D Full-Field Internal Strain & Displacement Mapping |
| Imaging Modality Compatibility | X-ray CT, MRI, OCT, Optical Tomography |
| Technique Principle | Digital Volume Correlation (DVC) |
| Compliance Framework | Supports GLP/GMP-aligned data traceability and ASTM E2774–19 (Standard Guide for Digital Image Correlation) |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | ParticleMaster inspex |
| Dispersion Method | Dry & Wet |
| Measurement Range | >5 µm |
| Repeatability | <1% |
| Measurement Time | 30–60 s |
| Compliance | IP54 |
| Light Source | LED (Eye-Safe) |
| Calibration | Factory-Preconfigured Particle Size & Depth-of-Field Calibration |
| Installation | Fixed-Mount Integrated Probe with Coaxial Illumination |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | PLIF-FlameMaster |
| Type | Planar Laser-Induced Fluorescence (PLIF) Diagnostic System for Quantitative Flame Imaging |
| Application Domain | Internal Combustion Engines, Gas Turbines, High-Pressure Burners, Chemical Reactors, Shock Tubes |
| Measurement Capabilities | OH*, CH*, C2* radical distribution |
| Compliance | Designed for GLP-compliant research environments |
| Interface | Engine synchronization via crank-angle encoder input |
| Software Platform | DaVis 10.5 with FlameMaster Module (supports 2D/3D reconstruction, time-resolved statistical analysis, multi-species spectral deconvolution, and FDA 21 CFR Part 11–compliant audit trail) |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PI-MAX4 |
| Price Range | USD 13,500 – 68,000 (est.) |
| Sensor Format | 1024 × 1024 interline CCD |
| Pixel Size | 13 µm × 13 µm |
| Effective Imaging Area | 13.3 mm × 13.3 mm |
| Image Intensifier Coupling | Fiber-optic taper (18 mm input window) |
| Spectral Response | 185 nm – 1100 nm |
| Minimum Gating Width | 3 ns |
| Full-Frame Frame Rate | 26 fps at 16-bit depth |
| Interface | Gigabit Ethernet (GigE Vision compliant) |
| Max Cable Length | >50 m |
| Software Control | Fully integrated with DaVis® v8.x and higher |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | TR-PLIF |
| Laser Repetition Rate | ≥1 kHz |
| Excitation Source | Frequency-Doubled Nd:YAG (532 nm), Pumped by High-Repetition-Rate YAG Laser |
| Detection | Intensified CCD or sCMOS Camera with Sub-Microsecond Gating |
| Temporal Resolution | <100 ns (adjustable via optical delay and camera gating) |
| Spatial Resolution | ≤50 µm (system-limited, dependent on optics and pixel binning) |
| Spectral Bandwidth | Tunable via narrowband interference filters (FWHM ≈ 1–5 nm) |
| Compliance | CE Marked, RoHS Compliant |