LaVision GmbH
Filter
Showing 31–60 of 71 results
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | FluidMaster-Multi Phase |
| Wavelength Accuracy | ±2.0 nm |
| Spectral Bandwidth (Slit) | 1.5–20 nm |
| Optical Resolution | 1.0 nm |
| Sensitivity | 1% |
| Dispersive Elements | Grating and Interference Filters |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | FluidMaster-Thermal |
| Dispersion Unit | Grating and Interference Filters |
| Slit Width (Spectral Bandpass) | 1.5 nm – 20 nm |
| Spectral Resolution | 1.0 nm |
| Sensitivity | 1% |
| Wavelength Accuracy | ±2.0 nm |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | FRAME |
| Frame Rate (Equivalent) | 4× @ 1 MHz (per exposure sequence) |
| Effective Temporal Resolution | 1 µs inter-frame interval |
| Number of Simultaneously Captured Frames per Exposure | 4 |
| Illumination Modulation Frequency | 40 lp/mm (at object plane) |
| Imaging Resolution (Effective FRAME Sequence) | 500 × 400 pixels |
| System Synchronization | Fully synchronized with DaVis software and PTUX timing unit |
| Compliance | Designed for GLP/GMP-aligned experimental workflows |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | Glass-SFR |
| Application Domain | Automotive Optical Quality Assurance, Windshield Diopter Mapping & ADAS Camera System Performance Validation |
| Compliance Context | ISO 16508-2, ECE R43, ISO/IEC 17025 (for accredited labs), ASTM E3087 (MTF measurement practice) |
| Imaging Principle | High-resolution digital image-based spatial frequency analysis via calibrated pattern projection and sub-pixel displacement field reconstruction |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | HighSpeedStar |
| Effective Resolution | 2016 × 2016 pixels |
| Pixel Size | 11 µm |
| Max Full-Resolution Frame Rate | up to 22 kHz |
| Max Reduced-Resolution Frame Rate | up to 600 kHz+ |
| Intensifier Option | HS-IRO (lens-coupled, multi-stage MCP amplification) |
| Software Integration | Fully compatible with DaVis and PTU X control platforms |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | ICOS |
| Application | In-cylinder crank-angle-resolved optical sensing for air/fuel ratio, EGR rate, CO₂ concentration, gas temperature, and H₂O concentration |
| Probe Integration | Spark plug–, glow plug–, or M5-threaded mounting |
| Measurement Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) with wavelength modulation spectroscopy (WMS) |
| Data Resolution | Crank-angle-resolved (≤0.1° CA), single-cycle capable |
| Response Time | <10 µs |
| Compatibility | Gasoline, Diesel, CNG, and multi-fuel engines |
| Certification Compliance | Designed for ISO 8178, ASTM D975/D3606, and EU Stage V R96-compliant test bed environments |
| Software Interface | Compatible with LaVision DaVis and third-party DAQ systems (e.g., NI VeriStand, dSPACE SCALEXIO) via TTL/encoder synchronization |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | ICOS-Temperature |
| Application Domain | In-cylinder combustion diagnostics |
| Measurement Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) in the near-infrared (NIR) range |
| Output Resolution | Crank-angle-resolved (≤0.1° CA), single-cycle or multi-cycle averaged |
| Probe Options | Non-intrusive fiber-coupled optics or minimally intrusive sapphire-windowed probes |
| Compliance | Designed for integration into ISO 2534, SAE J1939, and EU Regulation (EC) No 715/2007 test environments |
| Data Interface | Ethernet (TCP/IP), synchronized with engine position encoder (e.g., AVL PUMA, ETAS INCA) |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | imager CX3p |
| Image Resolution | 5312 × 4608 |
| Pixel Size | 54 µm × 54 µm |
| Sensor Dimensions | 14.6 mm × 12.6 mm |
| Readout Speed | 96 Hz |
| Dynamic Range | 12-bit |
| Quantum Efficiency | ~70% @ 510 nm |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | Imager LX |
| Sensor Type | Progressive Scan CCD |
| Resolution | 8–29 MP |
| Bit Depth | Up to 14-bit |
| Minimum Interframe Time | 0.3 µs |
| Interface | Gigabit Ethernet |
| Camera Form Factor | Compact Industrial Housing |
| Distribution Model | Authorized International Distributor (Imported) |
| Brand | LaVision GmbH |
|---|---|
| Country of Origin | Germany |
| Sensor Type | Scientific CMOS (sCMOS) |
| Resolution | 5.5 MP (2560 × 2160) |
| Full-Resolution Frame Rate | 50 Hz |
| Read Noise | <1.2 e⁻ RMS |
| Dynamic Range | >85 dB |
| Interface | Camera Link HS or CoaXPress 2.0 |
| Cooling | Thermoelectric (−10 °C to +20 °C, adjustable) |
| Shutter Modes | Global shutter, rolling shutter, and double-frame burst mode for PIV |
| Synchronization | TTL/RS-422 trigger input & output, <100 ns jitter |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | Camera-DIC |
| Image Resolution | 1936 × 1216 pixels |
| Pixel Size | 5.86 × 5.86 µm² |
| Sensor Active Area | 11 × 7 mm |
| Readout Speed | 200 MHz |
| Dynamic Range | 12-bit |
| Quantum Efficiency | >70% |
| Interface | USB 3.0 (Imager M-lite series) / Camera Link / CoaXPress (high-speed variants) |
| Cooling | Thermoelectric (Peltier), optional |
| Shutter Type | Global shutter (CMOS), electronic rolling shutter (configurable per model) |
| Onboard Memory | None (host-based acquisition) |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | Imager sCMOS / Imager SX / Imager MX / Imager LX / MiniShaker Series |
| Effective Resolution | up to 29 MP (29 million pixels) |
| Pixel Size | 6.5 µm |
| Full-Resolution Frame Rate | 18–50 Hz (varies by model) |
| High-Speed Mode | up to 1 kHz (704 × 358 px) |
| Interframe Time | down to 0.3 µs |
| Sensor Type | scientific CMOS (sCMOS), progressive-scan CCD, or high-speed CMOS |
| Interface | CameraLink HS, Gigabit Ethernet |
| Compliance | Fully integrated with DaVis software for time-resolved PIV, double-frame acquisition, and μs-scale interframe timing |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | Imager SX |
| Resolution | 4 MP or 5 MP |
| Max Frame Rate | 30 Hz (4 MP) / 15 Hz (5 MP) |
| Sensor Type | Scientific-grade CCD |
| Operating Modes | Full-resolution & binning-enabled high-speed mode |
| Form Factor | Compact, lightweight industrial housing |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | Imager UV |
| Spectral Range | Optimized for UV (180–400 nm) |
| Minimum Exposure Time | 1 µs |
| Quantum Efficiency | >50% at 254 nm, >30% at 200 nm |
| Sensor Type | Back-illuminated, UV-enhanced CCD |
| Dynamic Range | ≥70 dB (typical, full-well capacity >100 ke⁻) |
| Interface | Camera Link or GigE Vision (configurable) |
| Cooling | Thermoelectric (−10 °C to −20 °C stabilized) |
| Compliance | CE, RoHS, ISO 9001 manufacturing environment |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | IRO |
| Effective Pixels | 2048 × 2048 |
| Pixel Size | 6.5 µm |
| Minimum Gating Time | 5 ns |
| Coupling Type | Lens-Coupled |
| Control Interface | Universal IRO Controller (DaVis Software Compatible) |
| Compliance | Designed for GLP/GMP-aligned optical diagnostics, compatible with ASTM E2831-22 (standard practice for intensified imaging in combustion and fluid dynamics) |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | LS |
| Measured Quantity | Partial Pressure of Water Vapor & Total Pressure |
| Measurement Range | >0.02 mbar (total pressure), >10 mbar (water vapor pressure) |
| Sampling Rate | Up to 600 vials/min |
| Sample Preparation | No air purging required |
| Compliance Context | Designed for ASTM F2338-22, ISO 11607-2, and USP <1207> compliant container closure integrity testing (CCIT) |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | NanoStar |
| Sensor | 2048 × 2048 sCMOS, 16-bit |
| Frame Rate | 104 fps (full frame, 16-bit, uncompressed) |
| Exposure Time | 4 ns – 1 s |
| Image Intensifier | 25 mm aperture, high-resolution |
| Coupling | Optimized lens cascade coupling |
| Interface | Camera Link HS over fiber optic |
| Software Control | DaVis platform |
| Compliance | Designed for GLP/GMP- and ISO/IEC 17025-aligned laboratory environments |
| Brand | LaVision GmbH |
|---|---|
| Country of Origin | Germany |
| Model | OA-STB |
| Measurement Capability | 3D3C (Three-Dimensional, Three-Component) |
| Measurement Frequency | Low-Frequency Temporal Resolution |
| Velocity Range | 0–1000 m/s |
| Accuracy | ±1% of measured velocity |
| Measurement Volume | 1 m × 1 m × 1 m |
| Software Requirement | DaVis 11.2 or later |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ParticleMaster Inspex |
| Dispersion Method | Dry & Wet Dispersion |
| Instrument Type | Laboratory Laser Imaging Analyzer |
| Measurement Range | 10–5000 µm |
| Repeatability | ±1% (relative) |
| Measurement Speed | Transient imaging at 25–50 Hz frame rate |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | ParticleMaster-IMI |
| Price Range | USD 105,000 – 132,000 (FOB Hamburg) |
| Dispersion Method | Dry & Wet Dispersion |
| Measurement Range | 5 µm – 3500 µm |
| Repeatability | <1% RSD |
| Measurement Time | 10–15 seconds per acquisition |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | ParticleMaster-Shadow |
| Dispersion Method | Dry & Wet |
| Measurement Range | 5–3500 µm |
| Repeatability | <1% |
| Measurement Time | 10–15 s |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | PLIF-HS |
| Camera Frame Rate | Up to 10 kHz |
| Laser Repetition Rate | ≥10 kHz |
| Imaging Modality | Planar Laser-Induced Fluorescence (PLIF) |
| Target Species | OH, CH, NO, acetone, ketones, hydrocarbons |
| Synchronization Precision | <1 ns jitter (PTU X timing unit) |
| Software Platform | FlameMaster v5.x with real-time acquisition & post-processing modules |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | PTUx |
| Form Factor | PCI board or standalone USB device |
| Timing Jitter | ≤ 0.05 ns |
| Firmware | Internally stored, model-optimized |
| Compatibility | Fully integrated with DaVis software |
| Trigger Outputs | Multiple synchronized TTL/CMOS outputs |
| Application Scope | Multi-camera synchronization, laser pulse sequencing, PIV-dt scans, hypersampling, phase-resolved imaging |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | SootMaster |
| Instrument Type | Continuous Emission Monitoring System (CEMS) for Soot |
| Application Domain | In-situ, time-resolved soot volume fraction and primary particle size distribution imaging in combustion flows |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | SprayMaster-Geometry |
| Dispersion Method | Dry & Wet |
| Measurement Range | 5–3500 µm |
| Repeatability | <1% |
| Measurement Time | 10–15 seconds per acquisition |
| Optical Configuration | Backlighting, Light Sheet Imaging (Radial & Axial Cuts) |
| Software | Spray Geometry v5.x |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | SprayMaster inspex |
| Dispersion Method | Dry & Wet Dispersion |
| Measurement Range | 6–3500 µm |
| Repeatability | <1% |
| Measurement Time | 10–15 s |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | SprayMaster |
| Dispersion Method | Dry & Wet |
| Measurement Range | 5–3500 µm |
| Repeatability | <1% |
| Measurement Time | 10–15 s |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SprayMaster SLIPI |
| Pricing Range | USD 105,000 – 132,000 (FOB Hamburg) |
| Dispersion Method | Dry & Wet Dispersion |
| Instrument Type | Laboratory Laser-Based Planar Imaging System |
| Measurement Range | 5–3500 µm |
| Repeatability | <1% (RSD, N≥10, monodisperse PSL standards) |
| Measurement Time per Frame Sequence | 10–15 s |
| Core Technology | Structured Laser Illumination Planar Imaging (SLIPI) |
| Primary Detection Modes | Mie Scattering & Laser-Induced Fluorescence (LIF) |
| Optical Configuration | Synchronized Pulsed Nd:YAG Laser (532 nm or 266 nm), High-Speed CMOS Camera (≥1 MP, ≥10 kHz full-frame), Motorized SLIPI Grating Module, Precision Translation Stages |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | StrainM PT |
| System Type | Turnkey Portable Digital Image Correlation System |
| Camera Configuration | Dual high-sensitivity Imager E-Lite cameras |
| Illumination | Cold LED illumination system |
| Computing Platform | Integrated industrial-grade laptop |
| Software | StrainMaster PT v5.x with guided workflow and real-time 3D surface height & displacement calculation |
| Application Scope | Full-field shape, deformation, and strain measurement on static and quasi-static specimens |
| Compliance | Designed for ISO/IEC 17025-aligned testing environments |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | StrainMaser Components |
| Pricing | Available Upon Request |