LaVision GmbH
Filter
Showing 1–30 of 71 results
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | FlowMaster®-Mitas |
| Measurement Domain | Planar (2D/3D) |
| Measurement Frequency | Low-Frequency |
| Velocity Range | 0–20 m/s |
| Accuracy | ±1% |
| Measurement Field Size | 0–1 mm |
| Microscope Objective Magnification | 5×–40× |
| CCD Resolution | 1376 × 1040 pixels |
| Quantum Efficiency | 65% @ 500 nm |
| Interframe Time (min) | 500 ns |
| Spatial Resolution (XYZ Stage) | 0.05 µm |
| Positioning Accuracy (XYZ Stage) | ±3 µm |
| Travel Range (X/Y) | 120 mm |
| Travel Range (Z) | 20 mm |
| Sample Opening | 84 × 70 mm |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | FluidMaster |
| Type | Turnkey Laser Imaging System for Quantitative Fluid Mixing & Thermal Flow Analysis |
| Imaging Modalities | Planar Laser-Induced Fluorescence (LIF), Rayleigh Scattering, Raman Scattering |
| Measurement Outputs | Instantaneous 2D/3D concentration fields, temperature fields, pH distribution, reactive mixing degree, gas density maps |
| Spatial Resolution | µm-to-mm scale (application-dependent) |
| Temporal Resolution | Up to kHz frame rates (camera- and laser-pulse-limited) |
| Calibration | Traceable hardware and signal calibration per ISO/IEC 17025 principles |
| Software Platform | DaVis v10+ with real-time acquisition, multi-parameter synchronization, and GLP-compliant data logging |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | FluidMaster-BOS |
| Type | Imported Optical Measurement Instrument |
| Application | Quantitative 2D/3D density and temperature field imaging in transparent media |
| Compliance | Designed for GLP/GMP-aligned research environments |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | AIS |
| Price Range | USD 42,000 – 70,000 |
| Application Domain | Automotive Optical Metrology & ADAS Validation |
| Brand | LaVision GmbH |
|---|---|
| Country of Origin | Germany |
| Model | TriM Scope |
| Scan Mode Flexibility | Single-beam to multi-beam configurable scanning |
| Software Control | ImSpector Pro with millisecond-scale region switching |
| Detection Channels | Up to 8 non-descanned detectors (NDDs) |
| Detector Options | Cooled Generation III GaAsP PMTs or APDs |
| Quantum Efficiency Gain | Up to 40% higher than standard PMTs |
| OPO Compatibility | Full integration support for optical parametric oscillator excitation sources |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | DaVis |
| Software Type | Laser Imaging & PIV Analysis Software |
| Architecture | Native 64-bit |
| Integrated Hardware | >100 camera and laser models |
| Data Dimensionality Support | 2D, 3D, 4D (time-resolved volumetric) |
| Compliance Framework | Designed for GLP/GMP-aligned experimental workflows, audit-trail-ready data handling, ISO/IEC 17025-compatible metadata logging |
| Brand | LaVision GmbH |
|---|---|
| Country of Origin | Germany |
| Model | DaVis-Pressure |
| Software Type | PIV/PTV-Based Pressure Field Reconstruction Software |
| Compliance | Designed for ISO/IEC 17025-aligned laboratory environments, supports audit-ready data provenance in GLP/GMP contexts |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Type | Industrial Laser-Compatible Endoscopic Imaging System |
| Model Series | Endoscopes (VIS/UV, Camera & Illumination Variants) |
| Application Domain | High-Speed Combustion Diagnostics, PIV, LIF, Flame & Spray Visualization in IC Engines and Gas Turbines |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | EngineMaster inspex |
| Application Domain | Internal Combustion Engine Research |
| Core Function | Crank-Angle-Synchronized Endoscopic Spray & Combustion Visualization with Quantitative Image-Based Diagnostics |
| Compliance Context | Designed for ASTM D7463, ISO 8178-4, and GLP/GMP-aligned R&D environments |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | FlameMaster inspex |
| Application | Optical diagnostics of combustion processes via chemiluminescence imaging, two-color pyrometry, Abel-inverted 2D reconstruction, endoscopic high-temperature imaging, and high-speed flame dynamics analysis |
| Compliance | Designed for research-grade combustion laboratories compliant with ISO/IEC 17025-aligned measurement traceability and compatible with GLP/GMP-relevant data integrity frameworks (e.g., audit-trail-enabled software logging) |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | FlameMaster Multi-Parameter |
| Application Domain | In-situ, quantitative, multi-parameter laser diagnostics in reactive flows |
| Core Modalities | OH-LIF, CH-LIF, C₂-LIF, NO-LIF, PLIF (fuel), Mie scattering, Rayleigh scattering, thermographic phosphor imaging (TPI), particle image velocimetry (PIV), stereo-PIV, tomographic PIV (Tomo-PIV), dual-plane PIV, simultaneous multi-modal acquisition |
| Spatial Resolution | Sub-pixel (typically ≤ 10 µm/pixel with optimized optics) |
| Temporal Resolution | Up to 10 kHz (with high-speed CMOS cameras) |
| Laser Sources | Nd:YAG (266–1064 nm), OPO/OPA tunable systems (210–2000 nm), pulsed diode lasers |
| Detection | Intensified CCD (ICCD), scientific CMOS (sCMOS), EMCCD, stereo/tomographic camera configurations |
| Software Platform | DaVis 10.3+ with FlameMaster-specific modules (FlameAnalysis, ChemiLum, TempMap, VelocityEngine) |
| Compliance | Fully compatible with ISO/IEC 17025 laboratory accreditation workflows |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FlameMaster Multifunctional |
| Pricing | Available Upon Request |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | FlameMaster Raman |
| Instrument Type | Grating-Based Raman Spectrometer |
| Spectral Range | 300–800 nm |
| Spectral Resolution | 1 cm⁻¹ |
| Spatial Resolution | 1 mm |
| Minimum Wavenumber Shift | 10 cm⁻¹ |
| Spectral Reproducibility | ±0.15 cm⁻¹ |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | FlameMaster Tunable LIF |
| Application | Planar Laser-Induced Fluorescence (PLIF) imaging of diatomic flame species and radicals |
| Laser Type | Tunable pulsed dye laser integrated with Nd:YAG pump laser |
| Wavelength Range | Typically 210–800 nm (dependent on dye and harmonics) |
| Control Interface | Fully integrated with DaVis 10+ software platform |
| Calibration | Automated spectral calibration via LIF-excitation scan |
| Quantification Support | Reference burner-based concentration calibration |
| System Mounting | Modular rail-mounted configuration for flexible optical alignment |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | FlameMaster-PIV |
| Application Domain | Simultaneous PIV and OH-PLIF in reactive flows |
| Platform Integration | DaVis v10+ Synchronized Acquisition & Processing |
| Compliance Framework | ASTM E2912, ISO 20486 (Optical Diagnostics in Combustion), GLP-aligned Data Audit Trail |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | FlameMaster3D |
| Type | Tomographic Laser-Induced Fluorescence (LIF) and Chemiluminescence Imaging System |
| Configuration | Multi-camera or single-camera time-averaged volumetric acquisition |
| Compatible with | OH*, CH*, C₂*, and other flame radical emissions |
| Integrated with | FlowMaster Tomo PIV for concurrent 3D flow–flame coupling |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | FlowMaster 4D-PTV |
| Measurement Modality | Stereoscopic 3D3C (Three-Component, Three-Dimensional) |
| Temporal Resolution | >100 Hz |
| Velocity Range | 0–1000 m/s |
| Velocity Uncertainty | ±1% of measured value |
| Measurement Volume | 1000 mm × 1000 mm × 1000 mm |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | FlowMaster FSI |
| Measurement Capability | 3D3C (Three-Dimensional, Three-Component) |
| Frame Rate | >100 Hz |
| Velocity Range | 0–1000 m/s |
| Accuracy | ±1% of measured value |
| Measurement Volume | 1000 mm × 1000 mm × 1000 mm |
| Technique Integration | Synchronized Particle Image Velocimetry (PIV) and Digital Image Correlation (DIC) |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FlowMaster-STB |
| Measurement Capability | True 3D, three-component (3D3C) volumetric velocity field |
| Measurement Frequency | Low-to-medium temporal resolution (suitable for transient and quasi-steady flows) |
| Velocity Range | 0–1000 m/s |
| Accuracy | ±1% of measured velocity magnitude |
| Measurement Volume | 1 m × 1 m × 1 m (adjustable via optical configuration and seeding density) |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | FlowMaster® 3D |
| Measurement Dimensionality | 2D & 3D planar vector fields |
| Frame Rate | >100 Hz |
| Velocity Range | 0–3,000 m/s |
| Accuracy | ±1% of measured velocity |
| Measurement Field Size | 1 m × 1 m |
| Optical Configuration | Dual-camera stereoscopic imaging with Scheimpflug-aligned lenses |
| Calibration | Self-calibration enabled (target-free, off-field, distortion-corrected) |
| Software Platform | DaVis® v10+ |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | FlowMaster® |
| Measurement Capability | 2D & 3D planar velocity fields |
| Velocity Range | 0–2000 m/s |
| Accuracy | <1% RMS error |
| Measurement Area | 400 × 400 mm |
| Laser Pulse Energy | up to 2 × 425 mJ per pulse |
| Camera Resolution Options | 1 MP to 29 MP |
| Temporal Resolution | Single-shot to MHz-rate TR-PIV |
| Correlation Precision | ≤0.1 pixel |
| SNR (Velocity Field) | >45 |
| High-Confidence Vector Yield (>0.1 px error threshold) | >90% |
| Compliance | ASTM E2847, ISO 20486, GLP/GMP-ready data audit trail support in DaVis |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FlowMaster® thermographic |
| Measurement Capability | Planar (2D/3D) |
| Repetition Rate | 3 kHz |
| Velocity Range | ≤ 3.5 km/s |
| Temperature & Velocity Accuracy | ±1% of reading |
| Measurement Field Size | 200 mm × 200 mm |
| Particle Tracer | Micrometer-scale thermographic phosphor particles |
| Core Principle | Simultaneous phosphorescence lifetime-based thermometry and cross-correlation PIV |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | FlowMaster®-Adaptive |
| Measurement Domain | 2D/3D Planar |
| Measurement Frequency | Low-Frequency |
| Velocity Range | 0–2 km/s |
| Accuracy | ±1% |
| Measurement Area | 1 m × 1 m |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FlowMaster®-Dual |
| Measurement Capability | 3D3C (Three-Dimensional, Three-Component) |
| Measurement Frequency | Low-Frequency Operation (Typical Repetition Rates: 1–15 Hz for Dual-Plane Acquisition) |
| Velocity Range | 0–2,000 m/s |
| Accuracy | ±1% of Measured Velocity Magnitude |
| Measurement Field of View | Up to 1.0 m × 1.0 m (Configurable via Lens and Laser Sheet Geometry) |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | FlowMaster®-Endo |
| Measurement Domain | Planar (2D/3D) |
| Velocity Range | 0–2 km/s |
| Accuracy | ±1% of reading |
| Field of View | Up to 1 m × 1 m |
| Frame Rate | Low-frequency acquisition (typically < 100 Hz for high-resolution endoscopic configurations) |
| Optical Bandpass | Visible to UV (193–700 nm) |
| Compliance | Designed for integration with ASTM E2847, ISO 20456, and GLP/GMP-aligned experimental workflows |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | FlowMaster®-Micro |
| Measurement Domain | 2D & 3D planar velocity fields |
| Measurement Frequency | Low-frequency dual-pulse acquisition |
| Velocity Range | 0–10 m/s |
| Accuracy | ±1% of measured velocity |
| Field of View | 10 µm – 1 mm |
| Objective Magnification Range | 5× – 40× |
| Standard Camera | 1376 × 1040 pixels, 65% quantum efficiency @ 500 nm |
| Spatial Resolution | Down to ~0.1 pixel displacement uncertainty |
| Microscope Configuration | Upright or inverted fluorescence-compatible platform |
| Illumination Source | Dual-pulse Nd:YAG laser (typically 532 nm) |
| Tracer Compatibility | Fluorescent microspheres (e.g., Rhodamine B-doped polystyrene, 0.1–2 µm diameter) |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | FlowMaster®-surf |
| Measurement Domain | Planar (2D/3D) |
| Measurement Frequency | Low-frequency |
| Velocity Range | 0–2 km/s |
| Accuracy | ±1% of reading |
| Field of View | Up to 1 m × 1 m |
| Camera Requirement | Dual-camera stereo configuration |
| Core Technology | Digital Image Correlation (DIC) + Stereoscopic PIV |
| Software Platform | DaVis® v8.4+ |
| Compliance | ASTM E2847, ISO/IEC 17025-compatible workflows, GLP-aligned data traceability |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FlowMaster®-Tomo |
| Measurement Capability | 3D3C (Three-Dimensional, Three-Component) |
| Measurement Frequency | Low-to-Medium Repetition Rate (Typical Dual-Frame Acquisition) |
| Velocity Range | 0–2000 m/s |
| Accuracy | ±1% of measured velocity magnitude |
| Measurement Volume | 170 mm × 110 mm × 100 mm |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FlowMaster®-TR |
| Measurement Domain | 2D & 3D Planar |
| Frame Rate | >100 Hz (up to 100 kHz at reduced resolution) |
| Velocity Range | 0–8000 m/s |
| Accuracy | ±1% of measured velocity |
| Measurement Area | 400 × 400 mm |
| Camera Resolution | 1024 × 1024 pixels @ 5 kHz |
| Laser | High-Repetition Solid-State, Dual-Cavity, up to 50 mJ/pulse |
| Software Control | Fully integrated with DaVis® v10+ |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | FlowMaster®-UW |
| Measurement Domain | Planar (2D/3D) |
| Measurement Frequency | Low-frequency operation |
| Velocity Range | 0–2,000 m/s |
| Accuracy | ±1% of measured velocity |
| Measurement Area | Up to 1 m × 1 m |
| Optical Architecture | Modular submersible configuration with surface-mounted electronics |
| Compliance | Designed for ISO/IEC 17025-aligned laboratory environments and GLP-compliant fluid dynamics research |