LINSEIS
Filter
Showing 31–45 of 45 results
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | STA L82 |
| Temperature Range | RT to 1000 °C |
| Heating Rate | 0.01–100 K/min |
| Temperature Stability | ±0.001 °C |
| Maximum Sample Mass | 25 mg / 2500 mg |
| TG Resolution | 0.1 µg |
| DSC Sensitivity | ~4–17.6 µW |
| DTA Resolution | 0.03 nV |
| Vacuum Capability | 10⁻² mbar (≤800 °C) |
| Atmosphere Control | Inert, oxidative, reducing, humidified, or vacuum |
| Optional Autosampler | 42- or 90-position |
| Sensor Types | E/K/S thermocouples |
| Measurement Modes | TG, TG-DTA, TG-DSC, TG-DSC (Cp) |
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | STA L87 MSB |
| Temperature Range | –196 to 2400 °C |
| Max. Sample Mass | 10 g (standard balance) |
| Resolution | 1 µg |
| Pressure Range | UHV to 150 bar (metal version) |
| Measurement Principle | Magnetic suspension coupling with PID-controlled electromagnetic levitation |
| Compliance Options | ASTM E1131, ISO 11358, USP <731>, GLP/GMP-ready data logging |
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | STA/TGA L86 |
| Instrument Type | Universal Simultaneous Thermal Analyzer |
| Temperature Range | −150 °C to 2400 °C |
| Balance Sensitivity | 0.01 µg |
| Maximum Sample Capacity | 35 g / ±20000 mg |
| Vacuum Capability | 10⁻² mbar (pump-dependent) |
| Pressure Range (optional) | up to 5 bar |
| Heating Rate | 0.01–100 K/min |
| TG Resolution Options | 0.01 µg / 0.02 µg / 0.1 µg |
| DSC Sensor Types | E, K, S, B, C (C = DTA-only) |
| DSC Resolution | 0.3–1.2 µW |
| DTA Resolution | 0.03 nV |
| DTA Sensitivity | 1.5 µV/mW |
| DTA Range | ±250 µV / ±2500 µV |
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | STA/TGA L86 |
| Temperature Range | −150 °C to 500 / 700 / 1000 °C |
| Heating Rate | 0.01–100 K/min |
| Temperature Stability | ±0.001 °C |
| Maximum Sample Mass | 35 g |
| TG Resolution | 0.01–0.1 µg |
| DSC Resolution | 0.3–1.2 µW |
| DTA Resolution | 0.03 nV |
| Vacuum Capability | 10⁻² mbar (pump-dependent) |
| Pressure Range (optional) | up to 5 bar |
| Atmosphere Control | Inert, oxidizing, reducing, corrosive, and vacuum-compatible |
| Sensor Options | E/K/S/B/C (C-type for DTA only) |
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | TEG-Tester (TEG L34) |
| Temperature Range | Ambient to 300 °C (hot side) / −20 °C to 300 °C (cold side) |
| Sample Diameter | Ø20–60 mm (circular) or 20×20–40×40 mm (rectangular) |
| Thickness Capacity | Up to 25 mm |
| Clamp Force | 2–5 kN (motor-driven) |
| Current Range | 0–3 A DC |
| Voltage Range | 0–12 V DC |
| Voltage Resolution | 1.6 µV |
| Current Resolution | 1 µA |
| Voltage Accuracy | ±0.3 % |
| Current Accuracy | ±0.3 % |
| Temperature Accuracy | ±0.1 °C |
| Thermocouple Type | E-type |
| Reference Block Materials | Aluminum, Brass, Copper (custom options available) |
| Heating Power | 1.0 kW |
| Cooling Capacity | 1.0 kW at 10 °C / 0.5 kW at −20 °C |
| Pump Flow Rate | 27 L/min at 0.7 bar |
| Reservoir Volume | 3.8–7.5 L |
| Refrigerant | R449A |
| Sampling Interval | <10 ms |
| Operating Modes | CC, CV, FOC, MPPT, P&O |
| Heat Dissipation Capacity | 36 W |
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | TF-LFA L54 |
| Sample Size Range | 2 mm × 2 mm to 25 mm × 25 mm (arbitrary shape) |
| Thin-Film Thickness Range | 10 nm – 20 µm (sample-dependent) |
| Temperature Range | RT, RT–200 °C, or RT–500 °C |
| Atmosphere | Inert, oxidative, reductive, or vacuum down to 10⁻⁴ mbar |
| Thermal Diffusivity Range | 0.01 – 1200 mm²/s (sample-dependent) |
| Pump Laser | 405 nm, 300 mW, modulation frequency up to 200 MHz |
| Probe Laser | CW 532 nm, 25 mW |
| Detector | Si-based photodetector, active diameter 0.2 mm, bandwidth DC–400 MHz |
| Software | Integrated multilayer thermal modeling suite for extraction of κ, α, Cᵥ, η, and TBC |
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | TFA L59 |
| Thermal Conductivity Range | 0.05–200 W/(m·K) (3ω method, in-plane configuration) |
| Temperature Range | –160 °C to 280 °C |
| Vacuum Level | 1×10⁻⁴ mbar |
| Sample Thickness Compatibility | 5 nm – 25 µm |
| Electrical Conductivity Range | 0.05–1×10⁶ S/cm (Van der Pauw four-point probe) |
| Seebeck Coefficient Range | 5–2500 µV/K |
| Optional Hall Module | Magnetic Field up to 1 T (electromagnet) or 0.5 T (permanent magnet) |
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | TGA HP L85 |
| Temperature Range | RT to 1200 °C |
| Pressure Range | up to 150 bar |
| Balance Sensitivity | 0.1 µg |
| Maximum Sample Mass | 5 g |
| Vacuum Level | 10⁻⁴ mbar |
| Heating Rate | up to 300 K/min |
| Cooling Rate | up to 150 K/min |
| TG Sensor Types | E, K, S, B, C |
| TG-DSC Sensor Types | E, K, S, B, C |
| Interface | USB or Ethernet |
| Gas Configuration | 1–3 configurable gas channels (customizable) |
| Optional Accessories | Steam Generator, H₂/HC Auto-Vent & Gas Safety System |
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | TGA L81 |
| Temperature Range | –150 to 2400 °C |
| Balance Sensitivity | 0.1 µg |
| Maximum Sample Mass | 25 g |
| Vacuum Tightness | 10⁻² mbar |
| Optional DTA Calculation | Yes |
| Interface | USB |
| Compatibility | MS and/or FTIR for Evolved Gas Analysis (EGA) |
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | TGA L83 |
| Temperature Range | RT to 1100 °C |
| Heating/Cooling Rate | 0.001–250 °C/min |
| Maximum Sample Mass | 5 g |
| Cooling Time | <12 min (1100 °C → 100 °C) |
| Vacuum Capability | up to 10⁻³ mbar |
| Atmosphere Control | Inert, oxidative, reductive, vacuum |
| Gas Dosing | Integrated MFC module with 3 gas channels (1 purge + 2 reactive) |
| Sample Autosampler | Up to 90 positions |
| Crucible Materials | Pt, Al₂O₃, Au, Ag, Al, graphite, W, stainless steel (HP) |
| EGA Compatibility | FTIR, MS, GC-MS |
| Interface | USB |
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | TGA L87 MSB |
| Temperature Range | –196 to 2400 °C |
| Balance Sensitivity | 1 µg |
| Maximum Sample Mass | 10 g (standard balance) |
| Measurement Environment | Ultra-High Vacuum (UHV) to 150 bar (metal version) |
| Gas Analysis Compatibility | Mass Spectrometry (MS) and FTIR coupling supported |
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | THB L56 |
| Thermal Conductivity Range | 0.005–1800 W/(m·K) |
| Sample Types | Solids, Powders, Gels, Liquids |
| Standards Compliance | ASTM D5930-01, ISO 22007-2, ASTM D5334 |
| Measurement Principle | Transient Hot Bridge (THB) |
| Temperature Range (Sensor) | −150 to 700 °C |
| Typical Measurement Time | 1–10 min (solids), 1–120 s (liquids) |
| Specific Heat Capacity Range | 0.1–5 J/(g·K) |
| Thermal Diffusivity Range | 0.05–1200 mm²/s |
| Minimum Sample Size | 1.5 × 1.5 × 2 mm |
| Sensor Materials | Polyimide, Ceramic |
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | TIM-Tester (TIM L58) |
| Measurement Principle | Laser Flash Method (ASTM D5470–17 compliant) |
| Sample Capacity | Single sample per test |
| Test Environment | Ambient temperature operation |
| Accuracy | ±0.1% at 50% stroke, ±0.25% at 100% stroke |
| Thermal Conductivity Range | 0.1–50 W/(m·K) (extendable upon configuration) |
| Sample Forms | Solid, powder, paste, liquid, adhesive, foil |
| Sample Dimensions | Circular Ø20/25/40 mm |
| Thermal Resistance Range | 0.01–8 K/W |
| Temperature Range | −30 °C to 300 °C (configurable) |
| Contact Pressure | 0–16 MPa (dependent on sample area) |
| Cooling System | External water-cooling unit |
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | TMA L71 (TMA PT1000) |
| Temperature Range | –260 to 1000 °C |
| Force Range | up to 1 / 5.7 / 20 N |
| Frequency Range | 1 Hz |
| Resolution | 0.125 nm |
| Atmosphere Options | Oxidizing, Reducing, Inert, Static or Dynamic |
| Sample Dimensions | up to 30 mm × 30 mm |
| Interface | USB |
| Optional Modules | DTA Analysis Software, Rate-Controlled Sintering (RCS) Software |
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | TMA L72 (TMA PT1600) |
| Temperature Range | RT to 1600 °C |
| Force Range | up to 1 N or 5.7 N |
| Frequency Range | 1 Hz or 5 Hz |
| Resolution | 0.125 nm |
| Atmosphere Options | Oxidizing, Reducing, Inert, Static/Dynamic |
| Sample Max Height | 30 mm |
| Interface | USB |
| Optional Modules | DTA Analysis Software, Rate-Controlled Sintering (RCS) Software |