Metrolux
Filter
Showing all 8 results
| Brand | Metrolux |
|---|---|
| Origin | Germany |
| Model | ML 2100 VariLux |
| Dimensions (ML2100/ML2150) | ~40×40×60 mm³ |
| Max. Avg. Power | 5 W |
| Available Wavelengths | 157–1064 nm |
| Max. Transmission | >70% (157 nm) to >90% (248–1064 nm) |
| Min. Transmission | <2% (157 nm) to <1% (≥248 nm) |
| Damage Threshold (1 Hz) | 0.2–15.0 J/cm² (wavelength-dependent) |
| Mounting | C-mount |
| Spectral Range (ML2300 PolarLux) | 185–2000 nm |
| Max. Input Power (ML2300) | <1000 W |
| Max. Avg. Power Density (ML2300) | <10,000 W/cm² |
| Max. Pulse Power Density (ML2300) | 2 GW/cm² |
| Beam Deviation | 90° (non-polarizing), 0° (polarizing) |
| Free Aperture (ML2300) | ~15×15 mm² |
| Wedge Material | Fused Silica |
| Neutral Density Filters | OD 0.9–4.0, absorbing & metallic types, 200–700 nm range |
| Brand | Metrolux |
|---|---|
| Origin | Germany |
| Model | ML 6020 |
| Wavelength Range | 400–1800 nm |
| Absolute Accuracy | typ. 5 × 10⁻⁷ |
| Relative Accuracy | 1 × 10⁻⁶ – 1 × 10⁻⁷ |
| Laser Linewidth | < 8 GHz |
| Measurement Rate | 8.3 Hz |
| Minimum Input Power | 100 µW |
| Maximum Input Power | 1.5 mW |
| Integrated He–Ne Reference Wavelength | 632.8 nm |
| Interface | IEC 625 (IEEE-488) GPIB |
| Brand | Metrolux |
|---|---|
| Origin | Germany |
| Model | ML 7400 |
| Spectral Range | 8–30 µm |
| Clear Aperture | 21 mm² |
| Sensor Dynamic Range | 50:1 |
| Sensor Resolution | 100 µm |
| Intensity Range | 20–1000 W/cm² |
| Damage Threshold | 2000 W/cm² |
| CW Input Power Limit | 200 W (unattenuated), 250 W (60 s with optional attenuation) |
| Response Time (50%) | 67 ms |
| Camera Resolution | 752 × 582 pixels |
| Frame Rate | up to 25 fps |
| Interface | IEEE 1394 (FireWire) |
| Dimensions | 267 × 125 × 71 mm³ |
| Weight | 1.7 kg |
| Power Supply | 230 V, 50 Hz, 300 W |
| Max Housing Temperature | 50 °C |
| Brand | Metrolux |
|---|---|
| Origin | Germany |
| Model | ML4515 |
| Wavelength Range | 400–700 nm / 700–1100 nm (custom options available) |
| Max. Beam Diameter | <6 mm (custom options available) |
| Max. Energy Density | <5 J/cm² (with optional attenuator) |
| Max. Power Density | <1000 W/cm² (with optional attenuator) |
| Single-Pulse Detection Rate | up to 1000 Hz |
| M² Measurement Range | 1.0–20.0 |
| M² Accuracy | ±3% |
| Measurement Frequency | 5 Hz |
| Dimensions | 210 × 310 × 155 mm³ |
| Weight | 5.7 kg |
| Software | BeamLux II & SquareLux |
| Camera Interface | IEEE 1394 (FireWire) |
| Optical Attenuation Range | 1:1 to 1:1,000,000 (motorized, automatic) |
| Brand | Metrolux |
|---|---|
| Origin | Germany |
| Model | ML4560 Wavefront Sensor |
| Sensor Head Compatibility | ML4010 |
| Detector | 2/3" CCD, 12-bit dynamic range |
| Pixel Array | 1392 × 1040 |
| Wavelength Range | 350–1100 nm (standard), 190–350 nm (with optional converter) |
| Pupil Size | 8.97 × 6.71 mm |
| Max Frame Rate | 15 fps |
| Spatial Resolution | 200 µm |
| Sub-aperture Count | 45 × 34 |
| Tilt Dynamic Range | ±1.6° (730 λ) |
| Focus Dynamic Range | 72 mm (370 λ) |
| Wavefront Accuracy | <50 nm RMS |
| System Accuracy | 10 nm RMS |
| Repeatability | 100 nm RMS |
| Wavefront Reconstruction Accuracy | <16 µrad |
| Curvature Accuracy | 5 × 10⁻⁴ /m |
| Brand | Metrolux |
|---|---|
| Origin | Germany |
| Model | ML4560 |
| Software Suite | raylux ML1240 (wavefront analysis) + beamlux ML1200 (ISO-compliant beam quality analysis) |
| Camera | ML3743 CCD, 2/3" format, 12-bit dynamic range, 1392 × 1040 pixels |
| Wavelength Range | 350–1100 nm (standard), extendable to 190–350 nm with optional converter |
| Pupil Size | 8.97 × 6.71 mm |
| Max Frame Rate | 15 fps |
| Spatial Resolution | 200 µm |
| Sub-Aperture Array | 45 × 34 |
| Dynamic Range (Tilt) | ±1.6° (730 λ) |
| Wavefront Accuracy | <16 µrad (intrinsic sensor), system-level wavefront accuracy: 10 nm RMS |
| Repeatability | 100 nm RMS |
| Dynamic Range (Focus) | 72 mm (370 λ) |
| Curvature Accuracy | 5 × 10⁻⁴ m⁻¹ |
| System Accuracy (absolute wavefront) | 10 nm RMS |
| M² Measurement Capability | 1–20, accuracy ±3%, single-pulse compatible up to 1 kHz |
| Beam Diameter Range | <6 mm (standard), customizable |
| Spectral Options | 400–700 nm & 700–1100 nm, others on request |
| Energy Density Limit | <5 J/cm² (with optional attenuator) |
| Power Density Limit | <1000 W/cm² (with optional attenuator) |
| Attenuation Range | 1:1 to 1:10⁶, motorized and software-controlled |
| Brand | Metrolux |
|---|---|
| Origin | Germany |
| Distribution Type | Authorized Distributor |
| Import Status | Imported |
| Pricing | Available Upon Request |
| Wavelength Range | 153–355 nm |
| Damage Threshold | Up to 15 J/cm² |
| Pulse Detection Rate | Up to 1 kHz (single-shot) |
| Active Area Homogeneity | >98% |
| Frame Latency | Low (sub-100 ms) |
| Supported Cameras | ML3720 (1/2" CCD, 782 × 582), ML3743 (2/3" CCD, 1392 × 1040) |
| Software | beamlux II Advanced (ML1201) |
| Optical Magnifications | 1×, 10×, 20×, 40× (model-dependent) |
| Max. Measurable Beam Size | Up to 200 mm (custom configurations available) |
| Brand | Metrolux |
|---|---|
| Origin | Germany |
| Model | ML6500 |
| Wavelength Range | 115–230 nm (single lamp), 115–320 nm (dual lamp: D₂ + Xe) |
| Spectral Resolution | < 1 nm FWHM at 160 nm |
| Wavelength Reproducibility | < 0.1 nm (validated at 121.5 nm and 160 nm) |
| Operating Pressure | < 1×10⁻⁵ mbar |
| Transmittance Accuracy | < ±0.3% |
| Reflectance Accuracy | < ±0.5% |
| Out-of-Band Transmittance | < 0.1% |
| Scattered Reflectance (157 nm) | > 0.001% |
| Diffuse Reflectance (157 nm, 1 mm aperture) | < 5% |
| Scattered Reflectance (157 nm, 1 mm aperture) | < 5% |